Introduction. Being challenging, multifragmentary proximal tibial fractures in patients with severe soft tissue injuries and/or short stature can be treated using externalized locked plating. A recent finite element study, investigating the fixation stability of plated unstable tibial fractures with 2-mm, 22-mm and 32-mm plate elevation under partial and full weight-bearing, reported that from a virtual biomechanical point of view, externalized plating seems to provide appropriate relative stability for secondary bone healing under partial weight-bearing during the early postoperative phase. The aim of the current study was to evaluate the clinical outcomes of using a
Abstract. Objective. To compare the clinical and radiological outcome between less invasive stabilization system (LISS, Synthes, Paoli, PA.) and open reduction with internal fixation (ORIF) for the treatment of extraarticular proximal tibia fractures through the lateral approach. Background. Proximal tibial fractures present a difficult treatment challenge with historically high complication rates. ORIF has been in vogue for long time with good outcome. But these are associated with problems especially overlying skin conditions, delayed recovery and rehabilitation with limited functional outcome.
Introduction. The incidence of distal femoral fractures in the geriatric population is growing and represents the second most common insufficiency fracture of the femur following fractures around the hip joint. Fixation of fractures in patients with poor bone stock and early mobilisation in feeble and polymorbide patients is challenging. Development of a fixation approach for augmentation of conventional
Introduction. The treatment of distal femoral fractures has undergone several changes during the past century, from non-operative techniques to more recently minimally-invasive internal fixation. The Less Invasive Stabilisation System (LISS) is an internal fixation plate that combines closed fixation of the distal femur using an anatomically pre-contoured plate with locked unicortical screws. Study aim. The purpose of this multicentre study was to review the use of the
The treatment of fractures of the proximal tibia is complex and makes great demands on the implants used. Our study aimed to identify what levels of primary stability could be achieved with various forms of osteosynthesis in the treatment of diaphyseal fractures of the proximal tibia. Pairs of human tibiae were investigated. An unstable fracture was simulated by creating a defect at the metaphyseal-diaphyseal junction. Six implants were tested in a uniaxial testing device (Instron) using the quasi-static and displacement-controlled modes and the force-displacement curve was recorded. The movements of each fragment and of the implant were recorded video-optically (MacReflex, Qualysis). Axial deviations were evaluated at 300 N. The results show that the nailing systems tolerated the highest forces. The lowest axial deviations in varus and valgus were also found for the nailing systems; the highest axial deviations were recorded for the buttress plate and the less invasive stabilising system (LISS). In terms of rotational displacement the