Advertisement for orthosearch.org.uk
Results 1 - 20 of over 10000
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11 | Pages 1546 - 1550
1 Nov 2012
Longo UG Loppini M Romeo G Maffulli N Denaro V

Wrong-level surgery is a unique pitfall in spinal surgery and is part of the wider field of wrong-site surgery. Wrong-site surgery affects both patients and surgeons and has received much media attention. We performed this systematic review to determine the incidence and prevalence of wrong-level procedures in spinal surgery and to identify effective prevention strategies. We retrieved 12 studies reporting the incidence or prevalence of wrong-site surgery and that provided information about prevention strategies. Of these, ten studies were performed on patients undergoing lumbar spine surgery and two on patients undergoing lumbar, thoracic or cervical spine procedures. A higher frequency of wrong-level surgery in lumbar procedures than in cervical procedures was found. Only one study assessed preventative strategies for wrong-site surgery, demonstrating that current site-verification protocols did not prevent about one-third of the cases. The current literature does not provide a definitive estimate of the occurrence of wrong-site spinal surgery, and there is no published evidence to support the effectiveness of site-verification protocols. Further prevention strategies need to be developed to reduce the risk of wrong-site surgery.


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 44 - 50
1 Mar 2024
Engh, Jr CA Bhal V Hopper, Jr RH

Aims. The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods. As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results. Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion. Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years. Cite this article: Bone Joint J 2024;106-B(3 Supple A):44–50


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 100 - 100
1 Sep 2012
Lakkol S Aranganathan S Reddy G Taranu R Friesem T
Full Access

Introduction. In the last decade, single level cervical arthroplasty has proven its efficacy as one of the surgical treatment option for for patients suffering from cervical degenerative disc disease. Recent published reports on multilevel cervical arthroplasty using single implants have shown statistically significant results when compared to single level surgery. The aim of this study is to compare the clinical outcomes of multilevel cervical arthroplasty to single level cervical arthroplasty, when more than one type of implants were used. Methods. This is a prospective study of consecutive patients who presented to our unit in between June 2006 and November 2009. The maximum follow-up period was 51 months (mean=18 months). Several types of cervical arthroplasty devices have been used in this study. The clinical outcome measures such as Visual Analogue Score for neck pain (VAS-NP) and arm pain (VAS-AP); Neck disability Index (NDI) and the Bodily pain component of Short Form 36 questionnaires were recorded pre and post operatively. After confirming the normality of the data appropriate parametric (paired t-test) were used to assess the statistical significance (p< 0.05) between pre and post-operative values. Two sample T-test was used to assess the significance between the differences in mean scores between each group. Results. A total of 105 patients (37 single level, 68 multi-level) were included in the study. Mean age of patients was 51 years (Range 32–80) with Male: Female ratio of 9:10. All clinical outcome measures showed statistically significant improvement in the post-operative period in single as well as multilevel group. However, there was no statistically significant difference in the improvement in between single and multilevel surgeries. Conclusions. Our study results clearly demonstrate that multilevel cervical arthroplasty offers the similar clinical outcome when compared to single level surgery, despite using different type of implant in multilevel surgeries


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 184 - 184
1 Mar 2006
Muminagic S Kapidzic T
Full Access

Introduction: Within the period from 1992. to 1996. (War in Bosnia) we performed 528 amputations. At the Chopart level in 45 (8.5%) patients and at the Syme level by 7 (1.3%) patients. Etiology: In more than 90 % patients the injury was caused by mine. Method: Open method, primary suture or primary delayed suture. We had 6 reamput actions and 15 corrections. Result: The Chopart stump inclines to deformation (we can often use only a part of calcaneus and talus). Achille’s tendon pulls the heel in increased supination and this is disturbing when leaning onto it and when placing the prosthesis. We achieved good results with the Baumgartner procedure: lengthening of Achille’s tendon, transfer of tendon m. tibialis anterior and tibio=tal=calcaneal arthrodesis. In cases with infection or if there remains only half of the calcaneus and talus, we prefer Syme level. Conclusion: The patient with CH stump was properly followed and kept under control. We prefer Baumgartner procedure as prevention of deformation. In some cases the better result are achieved with the Syme level (it remains only part of calcaneus and talus)


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 51 - 58
1 Mar 2024
Jenkinson MRJ Meek DRM Tate R Brady A MacMillan S Grant H Currie S

Aims. Elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties are a suggested risk factor for developing cardiovascular complications including cardiomyopathy. Clinical studies assessing patients with MoM hips using left ventricular ejection fraction (LVEF) have found conflicting evidence of cobalt-induced cardiomyopathy. Global longitudinal strain (GLS) is an echocardiography measurement known to be more sensitive than LVEF when diagnosing early cardiomyopathies. The extent of cardiovascular injury, as measured by GLS, in patients with elevated blood cobalt levels has not previously been examined. Methods. A total of 16 patients with documented blood cobalt ion levels above 13 µg/l (13 ppb, 221 nmol/l) were identified from a regional arthroplasty database. They were matched with eight patients awaiting hip arthroplasty. All patients underwent echocardiography, including GLS, investigating potential signs of cardiomyopathy. Results. Patients with MoM hip arthroplasties had a mean blood cobalt level of 29 µg/l (495 nmol/l) compared to 0.01 µg/l (0.2 nmol/l) in the control group. GLS readings were available for seven of the MoM cohort, and were significantly lower when compared with controls (-15.5% vs -18% (MoM vs control); p = 0.025)). Pearson correlation demonstrated that GLS significantly correlated with blood cobalt level (r = 0.8521; p < 0.001). However, there were no differences or correlations for other echocardiography measurements, including LVEF (64.3% vs 63.7% (MoM vs control); p = 0.845). Conclusion. This study supports the hypothesis that patients with elevated blood cobalt levels above 13 µg/l in the presence of a MoM hip implant may have impaired cardiac function compared to a control group of patients awaiting hip arthroplasty. It is the first study to use the more sensitive parameter of GLS to assess for any cardiac contractile dysfunction in patients with a MoM hip implant and a normal LVEF. Larger studies should be performed to determine the potential of GLS as a predictor of cardiac complications in patients with MoM arthroplasties. Cite this article: Bone Joint J 2024;106-B(3 Supple A):51–58


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 455 - 456
1 Oct 2006
Pimenta L Scott-Young M Cappuccino A McAfee P
Full Access

Introduction This is a prospective, consecutive series of 178 prosthetic implantations to analyse single level versus multiple level cervical arthroplasty with two years minimum follow-up. Methods Fifty-five patients underwent a total of fifty-five Porous Coated Motion (PCM) cervical arthroplasties from C3–4 to C7–T1 (Group S for single level). Fifty-four patients underwent one hundred and nine multilevel PCM cervical arthroplasties (Group M for multilevel) during the same time interval, for the same indications, performed by the same surgeons under the same clinical protocol— double level, 43 cases; three levels, 7 cases: and four levels, 4 cases. Sixteen PCM cases had been performed as complex revision procedures with prior fusions—9 in Group S and 7 in Group M. They included 1 previous Bryan Disc, 1 cage-plate, 1 patient with Klippel-Feil disease, 3 patients had failed lordotic cervical cages. One additional patient in Group M had a fracture-dislocation at C4–5 with a pseudarthrosis at C3–4 and C5–6. The demographics between Group S and Group M were very similar—mean age of patients, gender, severity of neurologic symptoms and distribution of radicular and myeloradicular symptoms. Results There were no deaths, no infections, and no instances of iatrogenic neurologic progression in either the single level or the multiple level arthroplasty group. The mean EBL, length of surgery, and length of hospital stay were greater for the Multilevel Group. In contrast to these three operative demographic statistics, the self assessment outcomes instruments consistently showed more improvement for the multilevel cases. The mean improvement in the NDI for the single cases was 54.8 % (+/− 20.9) versus the multilevel cases mean improvement in NDI was 64.8 % (+/− 33.7). The mean improvement in the VAS showed the same relationship—single level mean improvement 62.0 % (26.9) versus the multilevel cases mean VAS improvement was 68.1% (+/− 31.4). The SF-36, Odoms, and TIGT were also more improved for the multilevel versus the single level group. The reoperation rates, adverse events, and incidence of complications were the same between the single level to the multilevel arthroplasty groups. Discussion This prospective report of cervical arthroplasty demonstrates that each cervical vertebral level is biomechanically independent of the adjacent level, whether it contains an arthoplasty or an unoperated intervertebral disc. With the Porous Coated Motion cervical arthroplasty the incidence of reoperation did not increase proportionately higher as the number of cervical levels requiring instrumentation increased. Even in three and four level arthroplasty the true benefits of cervical disk replacement outcomes were demonstrated on functional clinical outcomes at minimum two-year follow-up


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 365 - 372
15 Mar 2023
Yapp LZ Scott CEH MacDonald DJ Howie CR Simpson AHRW Clement ND

Aims. This study investigates whether primary knee arthroplasty (KA) restores health-related quality of life (HRQoL) to levels expected in the general population. Methods. This retrospective case-control study compared HRQoL data from two sources: patients undergoing primary KA in a university-teaching hospital (2013 to 2019), and the Health Survey for England (HSE; 2010 to 2012). Patient-level data from the HSE were used to represent the general population. Propensity score matching was used to balance covariates and facilitate group comparisons. A propensity score was estimated using logistic regression based upon the covariates sex, age, and BMI. Two matched cohorts with 3,029 patients each were obtained for the adjusted analyses (median age 70.3 (interquartile range (IQR) 64 to 77); number of female patients 3,233 (53.4%); median BMI 29.7 kg/m. 2. (IQR 26.5 to 33.7)). HRQoL was measured using the three-level version of the EuroQol five-dimension questionnaire (EQ-5D-3L), and summarized using the Index and EuroQol visual analogue scale (EQ-VAS) scores. Results. Patients awaiting KA had significantly lower EQ-5D-3L Index scores than the general population (median 0.620 (IQR 0.16 to 0.69) vs median 0.796 (IQR 0.69 to 1.00); p < 0.001). By one year postoperatively, the median EQ-5D-3L Index score improved significantly in the KA cohort (mean change 0.32 (SD 0.33); p < 0.001), and demonstrated no clinically relevant differences when compared to the general population (median 0.796 (IQR 0.69 to 1.00) vs median 0.796 (IQR 0.69 to 1.00)). Compared to the general population cohort, the postoperative EQ-VAS was significantly higher in the KA cohort (p < 0.001). Subgroup comparisons demonstrated that older age groups had statistically better EQ-VAS scores than matched peers in the general population. Conclusion. Patients awaiting KA for osteoarthritis had significantly poorer HRQoL than the general population. However, within one year of surgery, primary KA restored HRQoL to levels expected for the patient’s age-, BMI-, and sex-matched peers. Cite this article: Bone Joint J 2023;105-B(4):365–372


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 54 - 54
1 Jul 2022
Jenner L Penfold C
Full Access

Abstract. Aims. Whilst short and mid-term activity levels after a Total Knee Replacement (TKR) have been reported in the literature; there is an over simplification of the reporting and longer-term activity levels are unknown. The aim of this study was to map the long-term trajectories of patients’ physical activity levels postoperatively to identify meaningful subgroups and explore associations with preoperative variables. Methods. This was a secondary analysis of a single centre longitudinal cohortstudy using group-based trajectory modelling (GBTM) of the University of California, Los Angeles (UCLA) physical activity score over ten years. Multinomial logistic regression models (both adjusted and unadjusted) were used to test associations between preoperative variables and trajectory group membership. Results. 266 of the 904 eligible patients were recruited (29%). Data from 260 patients was available for analysis. Four trajectory groups were identified with good fit of the model (average posterior probability 0.79 to 0.93). Of the four groups, the two more active groups had a peak activity level between two-three years postoperatively; the less active groups had a peak activity level at between three months and one year. Preoperative UCLA, participation in sports in the three years prior to surgery and male gender showed trends towards association with a higher activity group. Conclusions. Four trajectory groups were identified giving a more detailed understanding of temporal trends in physical activity levels post TKR. There was weak evidence to show an association between patient expectation, preoperative UCLA score and participation in sports in the prior three years and group membership


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 79 - 79
7 Nov 2023
Laubscher K Kauta N Held M Nortje M Dey R
Full Access

Arthroplasty procedures in low-income countries are mostly performed at tertiary centers, with waiting lists exceeding 12 to 24 months. Providing arthroplasty services at other levels of healthcare aims to offset this burden, however there is a marked paucity of literature regarding surgical outcomes. This study aims to provide evidence on the safety of arthroplasty at district level. Retrospective review of consecutive arthroplasty cases performed at a District Hospital (DH), and a Tertiary Hospital (TH) in Cape Town, between January 2015 and December 2018. Patient demographics, hospital length of stay, surgery related readmissions, reoperations, post-operative complications, and mortality rates were compared between cohorts. Seven hundred and ninety-five primary arthroplasty surgeries were performed at TH level and 228 at DH level. The average hospital stay was 5.2±2.0 days at DH level and 7.6±7.1 days for TH (p<0.05). Readmissions within 3 months post-surgery of 1.75% (4 patients) for district and 4.40% (35) for TH (p<0.05). Reoperation rate of 1 in every 100 patients at the DH and 8.3 in every 100 patients at the TH (p<0.05). Death rate was 0.4% vs 0.6% at district and TH respectively (p>0.05). Periprosthetic joint infection rate was 0.43% at DH and 2.26% at TH. The percentage of hip dislocation requiring revision was 0% at district and 0.37% at TH. During the study period, 228 patients received arthroplasty surgery at the DH; these patients would otherwise have remained on the TH waiting list. Hip and Knee Arthroplasty at District health care level is safe and may help ease the burden on arthroplasty services at tertiary care facilities in a Southern African context. Adequately trained surgeons should be encouraged to perform these procedures in district hospitals provided there is appropriate patient selection and adherence to strict theatre operating procedures


Bone & Joint Open
Vol. 3, Issue 3 | Pages 261 - 267
22 Mar 2022
Abe S Kashii M Shimada T Suzuki K Nishimoto S Nakagawa R Horiki M Yasui Y Namba J Kuriyama K

Aims. Low-energy distal radius fractures (DRFs) are the most common upper arm fractures correlated with bone fragility. Vitamin D deficiency is an important risk factor associated with DRFs. However, the relationship between DRF severity and vitamin D deficiency is not elucidated. Therefore, this study aimed to identify the correlation between DRF severity and serum 25-hydroxyvitamin-D level, which is an indicator of vitamin D deficiency. Methods. This multicentre retrospective observational study enrolled 122 female patients aged over 45 years with DRFs with extension deformity. DRF severity was assessed by three independent examiners using 3D CT. Moreover, it was categorized based on the AO classification, and the degree of articular and volar cortex comminution was evaluated. Articular comminution was defined as an articular fragment involving three or more fragments, and volar cortex comminution as a fracture in the volar cortex of the distal fragment. Serum 25-hydroxyvitamin-D level, bone metabolic markers, and bone mineral density (BMD) at the lumbar spine, hip, and wrist were evaluated six months after injury. According to DRF severity, serum 25-hydroxyvitamin-D level, parameters correlated with bone metabolism, and BMD was compared. Results. The articular comminuted group (n = 28) had a significantly lower median serum 25-hydroxyvitamin-D level than the non-comminuted group (n = 94; 13.4 ng/ml (interquartile range (IQR) 9.8 to 17.3) vs 16.2 ng/ml (IQR 12.5 to 20.4); p = 0.005). The AO classification and volar cortex comminution were not correlated with the serum 25-hydroxyvitamin-D level. Bone metabolic markers and BMD did not significantly differ in terms of DRF severities. Conclusion. Articular comminuted DRF, referred to as AO C3 fracture, is significantly associated with low serum 25-hydroxyvitamin-D levels. Therefore, vitamin D. 3. supplementation for vitamin D deficiency might prevent articular comminuted DRFs. Nevertheless, further studies must be conducted to validate the results of the current study. Cite this article: Bone Jt Open 2022;3(3):261–267


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 124 - 124
2 Jan 2024
Pascuet-Fontanet A Segarra-Queralt M Noailly J
Full Access

Osteoarthritis (OA) leads to articular cartilage degradation, following complex dysregulation of chondrocyte's metabolism towards a catabolic state. Mechanical and biochemical signals are involved and need to be considered to understand the condition. Regulatory network-based models (RNM) successfully simulated the biological activity of the chondrocyte and the transduction of mechanical signals at the molecular and cell levels. However, the knowledge gap between single-cell regulation and intercellular communication in tissue volumes hinders the interpretability of such models at larger scales. Accordingly, a novel tissue-level biochemical model is proposed. We hypothesise that it is possible to simulate interacting network effects through the transport of diluted species in a finite-element model, to grasp relevant dynamics of cell and tissue regulation in OA. Chondrocyte RNM equations were translated into a reaction term of 18 multi-species diffusion model (e.g., 3 anti-inflammatory and 8 pro-inflammatory interleukins, 3 pro-anabolic and 1 pro-catabolic growth factors, 2 nociceptive factors and 2 pro-inflammatory cytokines). Elements with RNM reaction terms represented the chondrocytes and were distributed randomly through the model, according to known cellular density in the knee cartilage, and could both react to and produce diffusive entities through the pericellular matrix, associated with reduced diffusion coefficients. The model was constructed over a 2D square of 0.47 mm sides considered to be in the middle of the cartilage, so boundary conditions were settled as periodic. Different simulations were initialised with initial concentrations of either healthy or pro-OA mediators. Preliminary results showed that, independently of the initial conditions, the chondrocytes successfully evolved into anabolic states, in absence of sustained pro-catabolic external stimulations, in contrast to single-cell RNM [2]. Our intercellular model suggests that paracrine communication may increase robustness towards cartilage maintenance, and future tests shall reveal new OA dynamics. Acknowledgements: Funding was provided by the European Commission (ERC-2021-CoG-O-Health-101044828)


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 90 - 90
19 Aug 2024
Sakai T Kaneoka T Okazaki T Matsuki Y Kawakami T Yamazaki K Imagama T
Full Access

Recently, some smart media devices including portable accelerometers have been used to measure objective physical activity (OPA) after total hip arthroplasty (THA). The aim of this study was to longitudinally assess OPA changes in patients who underwent THA using a compact triaxial accelerometer and to investigate the impact of this recovery process on patient-reported outcomes. This prospective cohort study involved 163 consecutive patients who had unilateral osteoarthritis of the hip and were followed up for 12 months after THA. There were 132 women and 31 men with average age of 66 years. OPA was measured using a compact triaxial accelerometer preoperatively and at 1, 3, 6, and 12 months postoperatively. This study investigated the recovery process of OPA in four patient groups classified by the median of age and preoperative activity levels (younger and higher activity (YH), younger and lower activity (YL), older and higher activity (OH), and older and lower activity (OL)), and examined its impact on patient-reported outcomes, including forgotten joint score-12 (FJS-12). The target period for regaining preoperative activity levels was approximately 3 months for patients with lower preoperative activity, and about 6 months for those with higher preoperative activity. The OPA at 12 months postoperatively was higher in the patients with higher preoperative activity levels than in those with lower preoperative activity levels. In patients with higher preoperative activity levels, FJS-12 scores significantly increased between 6 and 12 months postoperatively (p=0.018). FJS-12 at 12 months postoperatively was best in YH (81.7±18.9), followed by YL (73.5±22.9), OH (73.2±17.4), and OL (66.3±21.8). Differences in the recovery process of postoperative activity levels impacted the duration required for improvement in FJS-12 scores. These results can serve as indicators for setting activity goals in patients undergoing THA


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 376 - 385
1 Mar 2022
Gramlich Y Hofmann L Kress S Ruckes C Kemmerer M Klug A Hoffmann R Kremer M

Aims. This study compared the cobalt and chromium serum ion concentration of patients treated with two different metal-on-metal (MoM) hinged total knee arthroplasty (TKA) systems, as well as a titanium nitride (TiN)-coated variant. Methods. A total of 63 patients (65 implants) were treated using either a MoM-coated (n = 29) or TiN-coated (n = 7) hinged TKA (GenuX mobile bearing, MUTARS; Implantcast, Germany) versus the BPKS (Brehm, Germany) hinged TKA (n = 27), in which the weight placed on the MoM hinge is diffused through a polyethylene (PE) inlay, reducing the direct load on the MoM hinge. Serum cobalt and chromium ion concentrations were assessed after minimum follow-up of 12 months, as well as functional outcome and quality of life. Results. No differences in mean age (69 years, 40 to 86), mean age adapted Charlson Comorbidity Index (3.1 (SD 1.4)), mean BMI (29.2 kg/m. 2. (SD 5.8)), or number of other implants were observed between groups. Significant improvements in outcome scores and pain levels were achieved for all groups, and there was no difference in quality of life (12-Item Short-Form Health Survey questionnaire (SF-12)). Mean cobalt and chromium ion levels were significantly higher for the GenuX versus the BPKS hinged TKA (GenuX vs BPKS: cobalt: 16.3 vs 9.4 µg/l; chromium: 9.5 vs 5.2 µg/l). The TiN-coated implants did not appear to confer improvement in the metal ion levels. Metal ion concentrations above 7 µg/l were detected in 81%(29/36) of GenuX patients versus 41% (11/27) in the BPKS group. No GenuX patients had normal levels under 2 µg/l, versus 22% of BPKS patients. No significant reduction in outcome scores was observed regardless of the metal ion levels, whereas higher work-related activity was correlated with higher chromium concentrations. Conclusion. Hinged TKA, using MoM hinges, resulted in critically high cobalt and chromium ion concentrations. The BPKS hinged TKA showed significantly lower metal ion concentrations compared with the GenuX TKA. No benefits were observed using TiN coating. The different weightbearing mechanics might influence the wear of the component materials. Higher workloads and physical activity could influence chromium levels. Cite this article: Bone Joint J 2022;104-B(3):376–385


The Bone & Joint Journal
Vol. 106-B, Issue 3 Supple A | Pages 31 - 37
1 Mar 2024
Bunyoz KI Tsikandylakis G Mortensen K Gromov K Mohaddes M Malchau H Troelsen A

Aims. In metal-on-polyethylene (MoP) total hip arthroplasty (THA), large metal femoral heads have been used to increase stability and reduce the risk of dislocation. The increased size of the femoral head can, however, lead to increased taper corrosion, with the release of metal ions and adverse reactions. The aim of this study was to investigate the relationship between the size of the femoral head and the levels of metal ions in the blood in these patients. Methods. A total of 96 patients were enrolled at two centres and randomized to undergo MoP THA using either a 32 mm metal head or a femoral head of between 36 mm and 44 mm in size, being the largest possible to fit the thinnest available polyethylene insert. The levels of metal ions and patient-reported outcome measures (Oxford Hip Score, University of California, Los Angeles Activity Scale) were recorded at two and five years postoperatively. Results. At five years, the median levels of chromium, cobalt, and titanium were 0.5 μg/l (interquartile range (IQR) 0.50 to 0.62), 0.24 μg/l (IQR 0.18 to 0.30), and 1.16 μg/l (IQR 1.0 to 1.68) for the 32 mm group, and 0.5 μg/l (IQR 0.5 to 0.54), 0.23 μg/l (IQR 0.17 to 0.39), and 1.30 μg/l (IQR 1 to 2.05) for the 36 mm to 44 mm group, with no significant difference between the groups (p = 0.825, p = 1.000, p = 0.558). There were increased levels of metal ions at two years postoperatively in seven patients in the 32 mm group, compared with four in the 36 mm to 44 mm group, and at five years postoperatively in six patients in the 32 mm group, compared with seven in the 36 mm to 44 mm group. There was no significant difference in either the OHS (p = 0.665) or UCLA (p = 0.831) scores between patients with or without an increased level of metal ions. Conclusion. In patients who underwent MoP THA, we found no differences in the levels of metal ions five years postoperatively between those with a femoral head of 32 mm and those with a femoral head of between 36 mm and 44 mm, and no corrosion-related revisions. As taper corrosion can start after five years, there remains a need for longer-term studies investigating the relationship between the size of the femoral head size and corrosion in patients undergoing MoP THA. Cite this article: Bone Joint J 2024;106-B(3 Supple A):31–37


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 90 - 90
1 Dec 2022
Abbas A Toor J Du JT Versteeg A Yee N Finkelstein J Abouali J Nousiainen M Kreder H Hall J Whyne C Larouche J
Full Access

Excessive resident duty hours (RDH) are a recognized issue with implications for physician well-being and patient safety. A major component of the RDH concern is on-call duty. While considerable work has been done to reduce resident call workload, there is a paucity of research in optimizing resident call scheduling. Call coverage is scheduled manually rather than demand-based, which generally leads to over-scheduling to prevent a service gap. Machine learning (ML) has been widely applied in other industries to prevent such issues of a supply-demand mismatch. However, the healthcare field has been slow to adopt these innovations. As such, the aim of this study was to use ML models to 1) predict demand on orthopaedic surgery residents at a level I trauma centre and 2) identify variables key to demand prediction. Daily surgical handover emails over an eight year (2012-2019) period at a level I trauma centre were collected. The following data was used to calculate demand: spine call coverage, date, and number of operating rooms (ORs), traumas, admissions and consults completed. Various ML models (linear, tree-based and neural networks) were trained to predict the workload, with their results compared to the current scheduling approach. Quality of models was determined by using the area under the receiver operator curve (AUC) and accuracy of the predictions. The top ten most important variables were extracted from the most successful model. During training, the model with the highest AUC and accuracy was the multivariate adaptive regression splines (MARS) model, with an AUC of 0.78±0.03 and accuracy of 71.7%±3.1%. During testing, the model with the highest AUC and accuracy was the neural network model, with an AUC of 0.81 and accuracy of 73.7%. All models were better than the current approach, which had an AUC of 0.50 and accuracy of 50.1%. Key variables used by the neural network model were (descending order): spine call duty, year, weekday/weekend, month, and day of the week. This was the first study attempting to use ML to predict the service demand on orthopaedic surgery residents at a major level I trauma centre. Multiple ML models were shown to be more appropriate and accurate at predicting the demand on surgical residents as compared to the current scheduling approach. Future work should look to incorporate predictive models with optimization strategies to match scheduling with demand in order to improve resident well being and patient care


Bone & Joint Research
Vol. 10, Issue 6 | Pages 340 - 347
1 Jun 2021
Jenkinson MRJ Meek RMD Tate R MacMillan S Grant MH Currie S

Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 8 - 8
7 Nov 2023
Crawford H Baroncini A Field A Segar A
Full Access

7% of adolescent idiopathic scoliosis (AIS) patients also present with a pars defect. To date, there are no available data on the results of fusion ending proximal to a spondylolysis in the setting of AIS. The aim of this study was to analyze the outcomes of posterior spinal fusion (PSF) in this patient cohort, to investigate if maintaining the lytic segment unfused represents a safe option. Retrospective review of all patients who received PSF for AIS, presented with a spondylolysis or spondylolisthesis and had a min. 2-years follow-up. Demographic data, instrumented levels and preoperative radiographic data were collected. Mechanical complications, coronal or sagittal parameters, amount of slippage and pain levels were evaluated. Data from 22 patients were available (age 14.4 ± 2.5 years), 18 Lenke 1–2 and four Lenke 3–6. Five patients (24%) had an isthmic spondylolisthesis, all Meyerding I. The mean preoperative Cobb angle of the instrumented curves was 58 ± 13°. For 18 patients the lowest instrumented vertebra (LIV) was the last touched vertebra (LTV); for two LIV was distal to the LTV; for two, LIV was one level proximal to the LTV. The number of segments between the LIV and the lytic vertebra ranged from 1 to 6. At the last follow-up, no complications were observed. The residual curve below the instrumentation measured 8.5 ± 6.4°, the lordosis below the instrumented levels was 51.4 ± 13°. The magnitude of the isthmic spondylolisthesis remained constant for all included patients. Three patients reported minimal occasional low back pain. The LTV can be safely used as LIV when performing PSF for the management of AIS in patients with L5 spondylolysis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 48 - 48
17 Nov 2023
Williams D Swain L Brockett C
Full Access

Abstract. Objectives. The syndesmosis joint, located between the tibia and fibula, is critical to maintaining the stability and function of the ankle joint. Damage to the ligaments that support this joint can lead to ankle instability, chronic pain, and a range of other debilitating conditions. Understanding the kinematics of a healthy joint is critical to better quantify the effects of instability and pathology. However, measuring this movement is challenging due to the anatomical structure of the syndesmosis joint. Biplane Video Xray (BVX) combined with Magnetic Resonance Imaging (MRI) allows direct measurement of the bones but the accuracy of this technique is unknown. The primary objective is to quantify this accuracy for measuring tibia and fibula bone poses by comparing with a gold standard implanted bead method. Methods. Written informed consent was given by one participant who had five tantalum beads implanted into their distal tibia and three into their distal fibula from a previous study. Three-dimensional (3D) models of the tibia and fibula were segmented (Simpleware Scan IP, Synopsis) from an MRI scan (Magnetom 3T Prisma, Siemens). The beads were segmented from a previous CT and co-registered with the MRI bone models to calculate their positions. BVX (125 FPS, 1.25ms pulse width) was recorded whilst the participant performed level gait across a raised platform. The beads were tracked, and the bone position of the tibia and fibula were calculated at each frame (DSX Suite, C-Motion Inc.). The beads were digitally removed from the X-rays (MATLAB, MathWorks) allowing for blinded image-registration of the MRI models to the radiographs. The mean difference and standard deviation (STD) between bead-generated and image-registered bone poses were calculated for all degrees of freedom (DOF) for both bones. Results. The absolute mean tibia and fibula bone position differences (Table 1) between the bead and BVX poses were found to be less than 0.5 mm for both bones. The bone rotation differences were found to be less than 1° for all axes except for the fibula Z axis rotation which was found to be 1.46°. One study. 1. has reported the kinematics of the syndesmosis joint and reported maximum ranges of motion of 9.3°and translations of 3.3mm for the fibula. The results show that the accuracy of the methodology is sufficient to quantify these small movements. Conclusions. BVX combined with MRI can be used to accurately measure the syndesmosis joint. Future work will look at quantifying the accuracy of the talus to provide further understanding of normal ankle kinematics and to quantify the kinematics across a healthy population to act as a comparator for future patient studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 48 - 48
1 Jan 2003
Chojnowski A Crawford R
Full Access

Temporary immobilisation of joints can lead to permanent ankylosis or fusion. The aim of this study is to demonstrate that treatment of vertebral fractures by single level fusion and 2 level fixation preserves movement in the unfused lower motion segment after removal of metalwork. 12 consecutive thoracolumbar fractures were treated by posterior fixation over two motion segments with fusion of the upper injured segment. Average age 39 years (27–50yrs.) and 6 were male. L2 was most frequently affected (6) then T12 (3), L1(2) and L3(1). Using the Denis classification 9 were Burst type B, 1 was Burst type A and 2 were Compression type B. No patients had abnormal neurology or any other vertebral injury. All operations were performed by one surgeon (RC) within 7 days of injury. Metalwork bridging the injured vertebra was removed at mean 11 months (8–13 * one patient 27 months) and average follow up in this study was 12 months (2–40) after removal of metalwork. A simple pain questionnaire and flexion-extension radiographs were obtained. The average movement in the motion segment previously bridged by metalwork was 5 degrees (0–12). For comparison, the level below moved an average of 7 degrees (2–17). Kyphus angle was 11 degrees (1–18) on presentation corrected to 0 degrees at operation (−6 - +12) returning 1 year after removal of metalwork to 5 degrees (1–16). Pain scores (0–10) were measured retrospectively, prior to the accident mean 0(0–1) and at review 2.6 (0–6). Only one patient failed to return to previous employment. She had the highest pain score at 6, showed no movement at the bridged motion segment where removal of metalwork was delayed to 27 months