Advertisement for orthosearch.org.uk
Results 1 - 20 of 538
Results per page:

Aims. The aim of this study was to investigate the distribution of phenotypes in Asian patients with end-stage osteoarthritis (OA) and assess whether the phenotype affected the clinical outcome and survival of mechanically aligned total knee arthroplasty (TKA). We also compared the survival of the group in which the phenotype unintentionally remained unchanged with those in which it was corrected to neutral. Methods. The study involved 945 TKAs, which were performed in 641 patients with primary OA, between January 2000 and January 2009. These were classified into 12 phenotypes based on the combined assessment of four categories of the arithmetic hip-knee-ankle angle and three categories of actual joint line obliquity. The rates of survival were analyzed using Kaplan-Meier methods and the log-rank test. The Hospital for Special Surgery score and survival of each phenotype were compared with those of the reference phenotype with neutral alignment and a parallel joint line. We also compared long-term survival between the unchanged phenotype group and the corrected to neutral alignment-parallel joint line group in patients with Type IV-b (mild to moderate varus alignment-parallel joint line) phenotype. Results. The most common phenotype was Type I-b (mild to moderate varus alignment-medial joint line; 27.1% (n = 256)), followed by Type IV-b (23.2%; n = 219). There was no significant difference in the clinical outcomes and long-term survival between the groups. In Type IV-b phenotypes, the neutrally corrected group showed higher 15-year survival compared with the unchanged-phenotype group (94.9% (95% confidence interval (CI) 92.0 to 97.8) vs 74.2% (95% CI 98.0 to 100); p = 0.020). Conclusion. Constitutional varus was confirmed in more than half of these patients. Mechanically aligned TKA can achieve consistent clinical outcomes and long-term survival, regardless of the patient’s phenotype. The neutrally corrected group had better long-term survival compared with the unchanged phenotype group. Cite this article: Bone Joint J 2024;106-B(5):460–467


The Bone & Joint Journal
Vol. 103-B, Issue 7 Supple B | Pages 129 - 134
1 Jul 2021
Ayekoloye CI Abu Qa'oud M Radi M Leon SA Kuzyk P Safir O Gross AE

Aims. Improvements in functional results and long-term survival are variable following conversion of hip fusion to total hip arthroplasty (THA) and complications are high. The aim of the study was to analyze the clinical and functional results in patients who underwent conversion of hip fusion to THA using a consistent technique and uncemented implants. Methods. A total of 39 hip fusion conversions to THA were undertaken in 38 patients by a single surgeon employing a consistent surgical technique and uncemented implants. Parameters assessed included Harris Hip Score (HHS) for function, range of motion (ROM), leg length discrepancy (LLD), satisfaction, and use of walking aid. Radiographs were reviewed for loosening, subsidence, and heterotopic ossification (HO). Postoperative complications and implant survival were assessed. Results. At mean 12.2 years (2 to 24) follow-up, HHS improved from mean 34.2 (20.8 to 60.5) to 75 (53.6 to 94.0; p < 0.001). Mean postoperative ROM was flexion 77° (50° to 95°), abduction 30° (10° to 40°), adduction 20° (5° to 25°), internal rotation 18° (2° to 30°), and external rotation 17° (5° to 30°). LLD improved from mean -3.36 cm (0 to 8) to postoperative mean -1.14 cm (0 to 4; p < 0.001). Postoperatively, 26 patients (68.4%) required the use of a walking aid. Complications included one (2.5%) dislocation, two (5.1%) partial sciatic nerve injuries, one (2.5%) deep periprosthetic joint infection, two instances of (5.1%) acetabular component aseptic loosening, two (5.1%) periprosthetic fractures, and ten instances of HO (40%), of which three (7.7%) were functionally limiting and required excision. Kaplan-Meier Survival was 97.1% (95% confidence interval (CI) 91.4% to 100%) at ten years and 88.2% (95% CI 70.96 to 100) at 15 years with implant revision for aseptic loosening as endpoint and 81.7% (95% CI 70.9% to 98.0%) at ten years and 74.2% (95% CI 55.6 to 92.8) at 15 years follow-up with implant revision for all cause failure as endpoint. Conclusion. The use of an optimal and consistent surgical technique and cementless implants can result in significant functional improvement, low complication rates, long-term implant survival, and high patient satisfaction following conversion of hip fusion to THA. The possibility of requiring a walking aid should be discussed with the patient before surgery. Cite this article: Bone Joint J 2021;103-B(7 Supple B):129–134


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1292 - 1300
1 Jul 2021
Märtens N Heinze M Awiszus F Bertrand J Lohmann CH Berth A

Aims. The purpose of this study was to compare clinical results, long-term survival, and complication rates of stemless shoulder prosthesis with stemmed anatomical shoulder prostheses for treatment of osteoarthritis and to analyze radiological bone changes around the implants during follow-up. Methods. A total of 161 patients treated with either a stemmed or a stemless shoulder arthroplasty for primary osteoarthritis of the shoulder were evaluated with a mean follow-up of 118 months (102 to 158). The Constant score (CS), the Disabilities of the Arm, Shoulder and Hand (DASH) score, and active range of motion (ROM) were recorded. Radiological analysis for bone adaptations was performed by plain radiographs. A Kaplan-Meier survivorship analysis was calculated and complications were noted. Results. The ROM (p < 0.001), CS (p < 0.001), and DASH score (p < 0.001) showed significant improvements after shoulder arthroplasty for both implants. There were no differences between the groups treated with stemmed or stemless shoulder prosthesis with respect to the mean CS (79.2 (35 to 118) vs 74.4 (31 to 99); p = 0.519) and DASH scores (11.4 (8 to 29) vs 13.2 (7 to 23); p = 0.210). The ten-year unadjusted cumulative survival rate was 95.3% for the stemmed anatomical shoulder prosthesis and 91.5% for the stemless shoulder prosthesis and did not differ between the treatment groups (p = 0.251). The radiological evaluation of the humeral components in both groups did not show loosening of the humeral implant. The main reason for revision for each type of arthroplasties were complications related to the glenoid. Conclusion. The use of anatomical stemless shoulder prosthesis yielded good and reliable results and did not differ from anatomical stemmed shoulder prosthesis over a mean period of ten years. The differences in periprosthetic humeral bone adaptations between both implants have no clinical impact during the follow-up. Cite this article: Bone Joint J 2021;103-B(7):1292–1300


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 15 - 15
1 Feb 2020
Song S Kang S Park C
Full Access

Purpose. Long-term clinical and radiographic results and survival rates were compared between closed-wedge high tibial osteotomy (HTOs) and fixed-bearing unicompartmental knee arthroplasty (UKA) in patients with similar demographics. Methods. Sixty HTOs and 50 UKAs completed between 1992 and 1998 were retrospectively reviewed. There were no significant differences in preoperative demographics. The mean follow-up period was 10.7 ±5.7 years for HTO and 12.0 ±7.1 years for UKA (n.s.). The Knee Society knee and function scores, WOMAC, and range of motion (ROM) were investigated. The mechanical axis and femorotibial angle were evaluated. Kaplan–Meier survival analysis was performed (failure: revision to TKA), and the failure modes were investigated. Results. Most of the clinical and radiographic results were not different at the last follow-up, except ROM; ROM was 135.3 ±12.3° in HTO and 126.8 ±13.3° in UKA (p=0.005). The 5-, 10-, 15-, and 20-year survival rates were 100%, 91.0%, 63.4%, and 48.3% for closed-wedge HTO, respectively, and 90.5%, 87.1%, 70.8%, and 66.4% for UKA (n.s.). The survival rate was higher than that for UKA until 12 years postoperatively but was higher in UKAs thereafter, following a remarkable decrease in HTO. The most common failure mode was degenerative osteoarthritic progression of medial compartment in HTO and femoral component loosening in UKA. Conclusions. Long-term survival did not differ significantly between closed-wedge HTO and fixed-bearing UKA in patients with similar preoperative demographics and knee conditions. The difference in postoperative ROM and failure mode should be considered when selecting a procedure


The Bone & Joint Journal
Vol. 99-B, Issue 6 | Pages 834 - 840
1 Jun 2017
Clarke-Jenssen J Røise O Storeggen SAØ Madsen JE

Aims. Our aim in this study was to describe the long-term survival of the native hip joint after open reduction and internal fixation of a displaced fracture of the acetabulum. We also present long-term clinical outcomes and risk factors associated with a poor outcome. Patients and Methods. A total of 285 patients underwent surgery for a displaced acetabular fracture between 1993 and 2005. For the survival analysis 253 were included, there were 197 men and 56 women with a mean age of 42 years (12 to 78). The mean follow-up of 11 years (1 to 20) was identified from our pelvic fracture registry. There were 99 elementary and 154 associated fracture types. For the long-term clinical follow-up, 192 patients with complete data were included. Their mean age was 40 years (13 to 78) with a mean follow-up of 12 years (5 to 20). Injury to the femoral head and acetabular impaction were assessed with CT scans and patients with an ipsilateral fracture of the femoral head were excluded. Results. A total of 36 patients underwent total hip arthroplasty (THA). The overall ten-year survival of the hip joint was 86% (95% confidence interval (CI) 81% to 90%) and the 20-year survival was 82% (95% CI 76% to 87%). Injury to the femoral head and acetabular impaction were the strongest predictors of failure, with the long-term survival rate falling towards 50% in these patients. The survival fell to 0% at three years when both these risk factors were present in patients aged > 60 years. Conclusion. The long-term survival of the native hip joint after acetabular fractures was good, but the presence of injury to the femoral head and acetabular impaction proved to be strong predictors of failure, especially in patients aged > 60 years. These patients may be better treated with a combination of open reduction and internal fixation and primary arthroplasty. Cite this article: Bone Joint J 2017;99-B:834–40


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 410 - 410
1 Sep 2009
Longino D Hynes S Rout R Pandit H Beard D Gill H Dodd C Murray D Cooper C Javaid M Price A
Full Access

Purpose: The aim of this study is to compare the long-term survival results of TKA in patients under the age of 60, using. revision surgery and. poor functional outcome as the end-points. Method: From our knee database we identified a cohort of 60 total knee replacements that had been performed over 15 years previously. We identified those who had died, those who had been revised and established the Oxford Knee Score (OKS) for all those still surviving. Results Using the following endpoint criteria the cumulative 15-year survival was (A) revision surgery alone = 78% (CI 12), (B) revision surgery or an OKS less than or equal to 24 (50% of total OKS) = 63% (CI 13), and (C) revision surgery or moderate pain = 48% (CI 14). Conclusion The functional survival of TKA in patients under the age of 60 decreases in the second decade following implantation with a significant number of prostheses failing the patient due to knee pain


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 560 - 561
1 Oct 2010
Von Friesendorff M Akesson K Besjakov J
Full Access

Aim: Hip fracture is the most devastating outcome of osteoporosis with high early mortality. Less is known about men in terms of long-term survival and fracture risk, information of outmost importance in terms of strategies for fracture prevention. The aim of this study was to evaluate long-term survival, new fractures and residual life time risk of fracture in a cohort of men with hip fracture in different ages. This is the first study with a follow-up above 10 years. Methods: All men above 20 yrs of age suffering a hip fracture 1984–1985 in Malmö, Sweden were identified and followed up to 22 years or death. All new radiographic examinations related to musculoskeletal trauma with or without fracture were individually registered. Survival and fractures were evaluated in 5-year age bands and age-groups (< 75, 75–84 and ≥85 years). Kaplan Meier survival analyses were used to evaluate mortality and fracture risk. Results: 263 men (74.2 yrs, range 33–101) with an index hip fracture due to low energy trauma were identified. 56% had cervical fractures and 44% trochanteric with 6% having concomitant fractures. 10 % had suffered a previous hip fracture. After 22 years 94% were dead; 32 % within 1 yr, 62% within 5 yrs and 79% within 10yrs. Mean age at death was 80.1 yr (range 41–101), equal to a mean of 5.8 yrs above the mean age for fracture. The 50% survival in respectively age groups < 75, 75–84 and ≥ 85 years was 7 yrs, 2 yrs and 3 months. 74/263 (28%) suffered totally 131 fractures (1.8, range 1–7 fractures/patient) at 121 occasions. The majority suffered only a new fracture at one occasion (n=48, 65%). 14% of the fracture occasions occurred within 1 yr and half of the fractures occurred within 3.2 yrs. Mortality adjusted life time risk of fracture was 62% and 10-year risk of fracture was 47%. Conclusion: In this study we report fracture risk and mortality in a residual life time perspective in men after hip fracture. Men suffer hip fractures earlier in life and have, compared to women from the same cohort, higher early mortality (32% resp 21% (1 yr)) and lower residual lifetime risk of fracture (28% resp 45%). 1. The high early mortality probably mirrors a higher morbidity among male hip fracture patients. The consequence is that fracture preventing strategies need to consider both gender, age and mortality


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 29 - 29
1 Nov 2015
Pollalis A Grammatopoulos G Wainwright A Theologis T McLardy-Smith P Murray D
Full Access

Introduction. Joint preserving procedures have gained popularity in an attempt to delay arthroplasty in young, dysplastic hips. Excellent results can be achieved with peri-acetabular osteotomy (PAO) in congruent non-arthritic hips. The role of salvage procedures such as the Shelf acetabuloplasty remains undefined. This study aims to determine the long-term survival and functional outcome following Shelf acetabuloplasty and to identify factors that influence outcome. Patients/Materials & Methods. This is a retrospective, consecutive, multi-surgeon, case series from a UK referral centre. 125 Shelf procedures were performed between 1987–2013 on 117 patients for symptomatic hip dysplasia. Mean age was 33 years (15–53). Mean follow-up was 10 years (1–27). Radiographic parameters measured included pre-operative arthritis, acetabular-index, centre-edge-angle, joint congruency, subluxation and femoral sphericity. Oxford Hip and UCLA scores were collected at follow-up. Failure was defined as conversion to arthroplasty or OHS<20. Results. The acetabular index and centre-edge angles have been improved from 23° (SD:9) and 12° (SD:8) pre-operatively to 10° (SD:9) and 45° (SD:11) post-operatively. By follow-up, 63 hips (50%) had converted to arthroplasty. The mean OHS and UCLA scores were 33 (SD:12) and 6 (SD:3), respectively. Survival rates were 82% at 5 years, 60% at 10 years and 43% at 15 years. The only factor influencing 10-yr survival was minimal pre-op arthritis (65% Vs 40%, p=0.02). Optimal functional outcome was seen when post-operative centre-edge angle was between 20–40° (p=0.01). Discussion. This largest long-term series of Shelf acetabuloplasties reported to-date emphasises the value of this procedure in patients that pose treatment dilemmas as they are symptomatic, too young for arthroplasty but have features that make them unsuitable for PAO. Never-the-less, in 60% of cases a Shelf acetabuloplasty will delay arthroplasty for 10 years. If performed in patients with minimal arthritis and congruent joint 10-year survival is 85%. Conclusion. Shelf acetabuloplasty is a simple, reliable procedure with good mid- to long-term results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 143 - 143
1 Sep 2012
Kreshak JL Fabbri N Manfrini M Gebhardt M Mercuri M
Full Access

Purpose. Rotationplasty was first described in 1930 by Borggreve for treatment of limb shortening with knee ankylosis after tuberculosis. In 1948, Van Nes described its use for management of congenital defects of the femur and in the 1980s, Kotz and Salzer reported on patients with malignant bone tumors around the knee treated by rotationplasty as an alternative to above-knee amputation. Currently, rotationplasty is one of the options for surgical management of lower extremity bone sarcomas in skeletally immature patients but alternative limb salvage techniques, such as the use of expandable endoprosthesis, are also available. Despite rather satisfactory functional results have been uniformly associated with rotationplasty, concern still exists about the potential psychological impact of the new body imagerelated to the strange appearance of the rotated limb. Results of rotationplasty for sarcomas of the distal femur over a 20-year period were analyzed, focusing on long-term survival, function, quality of life and mental health. Method. Retrospective study of 73 children who had a rotationplasty performed at two institutions between 1984 and 2007 for a bone sarcoma of the distal femur; 42 males and 31 females, mean age at surgery 8.7 yrs (range 3–17). Four patients were converted to transfemoral amputation due to early vascular complication; 25 eventually died of their disease (mean survival 34 months, range 4–127). The 46 remaining survivors were evaluated for updated clinical outcome, MSTS score, gait analysis, SF-36 score, quality of life interview and psychological assessment at mean follow-up of 15 yrs (range 3–23). Results. Overall survival was 64%. All the survivors were disease-free at last follow-up. Four patients required hardware revision for nonunion and subsequently healed. Three patients refused participation in the long-term follow-up study. Mean MSTS score was 79 (range 64–88). SF-36 score was obtained in 35 patients (age > 16); male patients showed a trend toward greater activity and vitality. Compared to age-group norms, rotationplasty scores were lower for physical activity level (p <0.05) and higher for general health perception (p = 0.05) and mental health (p < 0.05). Conclusion. Rotationplasty remains a durable reconstructive option with good long-term function and acceptable psychological impact for children with bone sarcomas of the distal femur


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 580 - 580
1 Nov 2011
Hui C Salmon L Kok A Maeno S Pinczewski L
Full Access

Purpose: The management of degenerative arthritis of the knee in the younger, active patient often presents a challenge to the orthopaedic surgeon. Surgical treatment options include: high tibial osteotomy (HTO), uni-compartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The purpose of this study was to examine the long-term survival of closing wedge HTO in a large series of patients 8–19 years after surgery. Method: The results of 458 consecutive patients undergoing lateral closing wedge HTO for medial compartment osteoarthritis (MCOA) between 1990 and 2001 were reviewed. Between 2008–2009, patients were contacted via telephone and assessment included: incidence of further surgery, Oxford Knee Score, and British Orthopaedic Association (BOA) Patient Satisfaction Scale. Failure was defined as the need for revision HTO or conversion to UKA or TKA. Survival analysis was completed using the Kaplan-Meier method. Results: We were able to contact 400/458 (87%) patients for follow-up via telephone interview. Five patients (1%) who declined participation were excluded. Fifty-eight patients (13%) were lost to follow-up. Of the 395 patients, 12 (3%) had died of unrelated causes and 124 (31%) required further knee surgery. The remaining 259 (66%) completed the BOA patient satisfaction score and Oxford Knee Score. The probability of survival for HTO at 5, 10 and 15 years was 95%, 79% and 55% respectively. Multivariate regression analysis showed that only age < 50 years (p< 0.001) was associated with significantly longer survival. Mean Oxford Knee Score was 40/48 (range 17–60). Ninety-two percent (239/259 patients) were enthusiastic or satisfied and 90% (234/259 patients) would undergo HTO again at mean 11 years follow-up. Complications included: 5 pulmonary embolisms, 8 deep vein thromboses, 1 non-union, 1 post-operative subarachnoid hemorrhage and 1 transient peroneal nerve palsy. Conclusion: To our knowledge, we have reported the long-term follow-up of lateral closing wedge HTO in the largest group of patients in the literature. We found that the results of HTO do deteriorate over time but that HTO can be effective for as long as 19 years. In appropriately selected patients and circumstances, HTO gives high patient satisfaction and affords patients unrestricted activity for many years


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 656 - 660
1 May 2010
Ikävalko M Tiihonen R Skyttä ET Belt EA

Between 1982 and 1997, 403 consecutive patients (522 elbows) with rheumatoid arthritis underwent Souter-Strathclyde total elbow replacement. By the end of 2007, there had been 66 revisions for aseptic loosening in 60 patients. The mean time of follow-up was 10.6 years (0 to 25) The survival rates at five-, ten, 15 and 19 years were 96% (95%, confidence interval (CI) 95 to 98), 89% (95% CI 86 to 92), 83% (95% CI 78 to 87), and 77% (95% CI 69 to 85), respectively. The small and medium-sized short-stemmed primary humeral components had a 5.6-fold and 3.6-fold risk of revision for aseptic loosening respectively, compared to the medium-sized long-stemmed component. The small and medium-sized all-polyethylene ulnar components had respectively a 28.2-fold and 8.4-fold risk of revision for aseptic loosening, compared to the metal-backed ulnar components.

The use of retentive ulnar components was not associated with an increased risk of aseptic loosening compared to non-retentive implants.


Abstract

Introduction

The role of patellar resurfacing in total knee arthroplasty remains controversial. We questioned the effect of patellar resurfacing on the early and late revision rates after total knee arthroplasty.

Materials and Methods

We analysed the data of cumulative revisions of primary knee replacement from the NJR 19th Annual Report. NJR included secondary patellar resurfacing as a revision. We compared differences in the 3-year and 15-year revision rates between the patellar resurfacing and non-resurfacing for the different combinations of total knee replacements using a paired t-test. We performed subgroup analysis for the five combinations with the highest volumes.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1567 - 1573
1 Dec 2006
Kovac S Trebse R Milosev I Pavlovcic V Pisot V

We present a retrospective series of 170 cemented titanium straight-stem femoral components combined with two types of femoral head: cobalt-chromium (CoCr) alloy (114 heads) and alumina ceramic (50 heads). Of the study group, 55 patients (55 stems) had died and six (six stems) were lost to follow-up. At a mean of 13.1 years (3 to 15.3) 26 stems had been revised for aseptic loosening. The mean follow-up time for stable stems was 15.1 years (12.1 to 16.6).

Survival of the stem at 15 years was 75.4% (95% confidence interval (CI) 67.3 to 83.5) with aseptic failure (including radiological failure) as the end-point, irrespective of the nature of the head and the quality of the cement mantle. Survival of the stem at 15 years was 79.1% (95% CI 69.8 to 88.4) and 67.1% (95% CI 51.3 to 82.9) with the CoCr alloy and ceramic heads, respectively. The quality of the cement mantle was graded as a function of stem coverage: stems with complete tip coverage (type 1) had an 84.9% (95% CI 77.6 to 92.2) survival at 15 years, compared with those with a poor tip coverage (type 2) which had a survival of only 22.4% (95% CI 2.4 to 42.4). The poor quality of the cement mantle and the implantation of an alumina head substantially lowered the survival of the stem.

In our opinion, further use of the cemented titanium alloy straight-stem femoral components used in our series is undesirable.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 7 | Pages 941 - 948
1 Jul 2010
Stone KR Adelson WS Pelsis JR Walgenbach AW Turek TJ

We describe 119 meniscal allograft transplantations performed concurrently with articular cartilage repair in 115 patients with severe articular cartilage damage. In all, 53 (46.1%) of the patients were over the age of 50 at the time of surgery. The mean follow-up was for 5.8 years (2 months to 12.3 years), with 25 procedures (20.1%) failing at a mean of 4.6 years (2 months to 10.4 years). Of these, 18 progressed to knee replacement at a mean of 5.1 years (1.3 to 10.4). The Kaplan-Meier estimated mean survival time for the whole series was 9.9 years (sd 0.4). Cox’s proportional hazards model was used to assess the effect of covariates on survival, with age at the time of surgery (p = 0.026) and number of previous operations (p = 0.006) found to be significant.

The survival of the transplant was not affected by gender, the severity of cartilage damage, axial alignment, the degree of narrowing of the joint space or medial versus lateral allograft transplantation. Patients experienced significant improvements at all periods of follow-up in subjective outcome measures of pain, activity and function (all p-values < 0.05), with the exception of the seven-year Tegner index score (p = 0.076).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 412 - 412
1 Sep 2012
Merle C Streit M Inmann M Gotterbarm T Aldinger P
Full Access

Introduction

Total Hip Arthroplasty (THA) in patients after proximal femoral osteotomy remains a major challenge. Inferior survival for both cementless and cemented THA has been reported in this subgroup of patients.

Methods

We retrospectively evaluated the clinical and radiographic results of a consecutive series of 48 THAs (45 Patients) who had undergone conversion THA for failed intertrochanteric osteotomy after a mean of 12 years (2–33 years) using a cementless, grit-blasted, double-tapered femoral stem. Mean follow-up was 20 years (range, 15–25 years), mean age at surgery was 47 years (range, 13–55 years). Clinical results were evaluated using the Harris Hip Score. Kaplan-Meier survivorship analysis was performed to determine long-term outcomes for different end points.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 240 - 240
1 Jul 2008
BIAU D ANRACT P FAURE F MASCARD E BABINET A DUMAINE V LAURENCE V
Full Access

Purpose of the study: The rate of failure can be high for massive reconstruction prostheses after tumor resection. We studied the causes and possible factors of failure.

Material and methods: The series included 91 patients who underwent surgery from 1972 to 1994 for resection of a bone tumor involving the knee joint. A GUEPAR prosthesis was implanted in all cases for reconstruction (megaprosthesis in 58 cases and composite prosthesis in 33). The extensor system had to be reconstructed in 37 patients. A GUEPAR II implant was used in 73 patients; 48 of these implants had an antirotation system. The analysis was retrospective. Outcome was studied in terms of survival and independent factors predictive of failure unrelated to the tumor.

Results: Mean follow-up was 72 months. At last follow-up, 68 patients were living disease free. There were nine cases of rupture of the extensor system. Preservation of a continuous extensor system at the time of bone resection reduced the risk of rupture (p=0.036). Seven allografts fractured, two loosened, and six became infected. Use of an allograft did not reduce the risk of loosening (p=0.17). Intraxial laxity was observed in 17 patients. Use of an antirotation system was a factor of risk of intraxial laxity (p=0.0023) but not of aseptic loosening. Aseptic loosening was observed in 18 patients: 10 femur reconstruction and 8 tibia reconstruction. The difference was not significant (p=0.6). In all, 104 revisions were required in 53 patients; 36 revisions of the prosthesis, 23 of them for mechanical causes. Overall median survival, excepting tumor-related causes, was 130 months. It was 130 months for femur reconstructions and 117 for tibia reconstructions (p=0.57). Age, length of resection, tumor location, use of an allograft, and use of an antirotation system were not found to be significant prognostic factors for implant survival.

Discussion: As reported by many others, we found that the rate of failure of massive prostheses for infectious and mechanical causes remained high in patients treated for bone tumors involving the knee joint. Survival of massive implants is much lower than that of gliding prostheses.

Conclusion: Technical progress is required to improve the survival of massive implants used for the treatment of bone tumors involving the knee joint.


The Journal of Bone & Joint Surgery British Volume
Vol. 79-B, Issue 4 | Pages 583 - 589
1 Jul 1997
Kobayashi A Donnelly WJ Scott G Freeman MAR

We reviewed a consecutive series of 527 uninfected hip replacements in patients resident in the UK which had been implanted from 1981 to 1993. All had the same basic design of femoral prosthesis, but four fixation techniques had been used: two press-fit, one HA-coated and one cemented. Review and radiography were planned prospectively. For assessment the components were retrospectively placed into two groups: those which had failed from two years onwards by aseptic femoral loosening and those in which the femoral component had survived without revision or recommendation for revision.

All available radiographs in both groups were measured to determine vertical migration and examined by two observers to agree the presence of radiolucent lines (RLLs), lytic lesions, resorption of the neck, proximal osteopenia and distal intramedullary and distal subperiosteal formation of new bone. We then related the presence or absence of these features and the rate of migration at two years to the outcome with regard to aseptic loosening and determined the predictive value of each of these variables.

Migration of ≥2 mm at two years, the presence of an RLL of 2 mm occupying one-third of any one zone, and subperiosteal formation of new bone at the tip of the stem were predictors of aseptic loosening after two years. There were too few lytic lesions to assess at two years, but at five years a lytic lesion ≥2 mm also predicted failure. We discuss the use of these variables as predictors of femoral aseptic loosening for groups of hips and for individual hips.

We conclude that if a group of about 50 total hip replacements, perhaps with a new design of femoral stem, were studied in this way at two years, a mean migration of < 0.4 mm and an incidence of < 10% of RLLs of 2 mm in any one zone would predict 95% survival at ten years.

For an individual prosthesis, migration of < 2 mm and the absence of an RLL of ≤2 mm at two years predict a 6% chance of revision over approximately ten years. If either 2 mm of migration or an RLL of 2 mm is present, the chances of revision rise to 27%, and if both radiological signs are present they are 50%. If at five years a lytic lesion has developed, whatever the situation at two years, there is approximately a 50% chance of failure in the following five years.

Our findings suggest that replacements using a limited number of any new design of femoral prosthesis should be screened radiologically at two years before they are generally introduced. We also suggest that radiographs of individual patients at two years and perhaps at five years should be studied to help to decide whether or not the patient should remain under close review or be discharged from specialist follow-up.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 58 - 58
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Distal femoral replacement is recognised as the optimum treatment for malignant distal femoral tumours. Aseptic loosening is known to be a major cause for failure in these implants. Studies have indicated that the HA coated collar promotes osteointegration and bony in growth. This study compares long term aseptic loosening in implants with HA coated collars to those without in the immature skeleton.

Objectives:

To assess the effect of HA coated collars on aseptic loosening in extendable distal femoral replacement prosthesis in the immature skeleton.


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.