Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 42 - 42
1 Dec 2022
Fransen B Howard L MacDonell T Bengoa F Garbuz D Sheridan G Neufeld M
Full Access

Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the long-term survival and revision rates of HXLPE liners in primary THA, as well as the effect of liner thickness on these outcomes. We hypothesized that there would be no significant differences between the different liner thicknesses. We performed a retrospective database analysis from a single center of all primary total hip replacements using HXLPE liners from 2010 and earlier, including all femoral head sizes. All procedures were performed by fellowship trained arthroplasty surgeons. Patient characteristics, implant details including liner thickness, death, and revisions (all causes) were recorded. Patients were grouped for analysis for each millimeter of PE thickness (e.g. 4.0-4.9mm, 5.0-5.9mm). Kaplan-Meier survival estimates were estimated with all-cause and aseptic revisions as the endpoints. A total of 2354 patients (2584 hips) were included (mean age 64.3 years, min-max 19-96). Mean BMI was 29.0 and 47.6% was female. Mean follow-up was 13.2 years (range 11.0-18.8). Liner thickness varied from 4.9 to 12.7 mm. Seven patients had a liner thickness <5.0mm and 859 had a liner thickness of <6.0mm. Head sizes were 28mm (n=85, 3.3%), 32mm (n=1214, 47.0%), 36mm (n=1176, 45.5%), and 40mm (n=109, 4.2%), and 98.4% were metal heads. There were 101 revisions, and in 78 of these cases the liner was revised. Reason for revision was instability/dislocation (n=34), pseudotumor/aseptic lymphocyte-dominant vasculitis associated lesion (n=18), fracture (n=17), early loosening (n=11), infection (n=7), aseptic loosening (n=4), and other (n=10). When grouped by liner thickness, there were no significant differences between the groups when looking at all-cause revision (p=0.112) or aseptic revision (p=0.116). In our cohort, there were no significant differences in all-cause or aseptic revisions between any of the liner thickness groups at long-term follow-up. Our results indicate that using thinner HXPE liners to maximize femoral head size in THA does not lead to increased complications or liner failures at medium to long term follow-up. As such, orthopedic surgeons can consider the use of larger heads at the cost of liner thickness a safe practice to reduce the risk of dislocation after THA when using HXLPE liners


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 15 - 15
1 Feb 2020
Song S Kang S Park C
Full Access

Purpose. Long-term clinical and radiographic results and survival rates were compared between closed-wedge high tibial osteotomy (HTOs) and fixed-bearing unicompartmental knee arthroplasty (UKA) in patients with similar demographics. Methods. Sixty HTOs and 50 UKAs completed between 1992 and 1998 were retrospectively reviewed. There were no significant differences in preoperative demographics. The mean follow-up period was 10.7 ±5.7 years for HTO and 12.0 ±7.1 years for UKA (n.s.). The Knee Society knee and function scores, WOMAC, and range of motion (ROM) were investigated. The mechanical axis and femorotibial angle were evaluated. Kaplan–Meier survival analysis was performed (failure: revision to TKA), and the failure modes were investigated. Results. Most of the clinical and radiographic results were not different at the last follow-up, except ROM; ROM was 135.3 ±12.3° in HTO and 126.8 ±13.3° in UKA (p=0.005). The 5-, 10-, 15-, and 20-year survival rates were 100%, 91.0%, 63.4%, and 48.3% for closed-wedge HTO, respectively, and 90.5%, 87.1%, 70.8%, and 66.4% for UKA (n.s.). The survival rate was higher than that for UKA until 12 years postoperatively but was higher in UKAs thereafter, following a remarkable decrease in HTO. The most common failure mode was degenerative osteoarthritic progression of medial compartment in HTO and femoral component loosening in UKA. Conclusions. Long-term survival did not differ significantly between closed-wedge HTO and fixed-bearing UKA in patients with similar preoperative demographics and knee conditions. The difference in postoperative ROM and failure mode should be considered when selecting a procedure


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 143 - 143
1 Sep 2012
Kreshak JL Fabbri N Manfrini M Gebhardt M Mercuri M
Full Access

Purpose. Rotationplasty was first described in 1930 by Borggreve for treatment of limb shortening with knee ankylosis after tuberculosis. In 1948, Van Nes described its use for management of congenital defects of the femur and in the 1980s, Kotz and Salzer reported on patients with malignant bone tumors around the knee treated by rotationplasty as an alternative to above-knee amputation. Currently, rotationplasty is one of the options for surgical management of lower extremity bone sarcomas in skeletally immature patients but alternative limb salvage techniques, such as the use of expandable endoprosthesis, are also available. Despite rather satisfactory functional results have been uniformly associated with rotationplasty, concern still exists about the potential psychological impact of the new body imagerelated to the strange appearance of the rotated limb. Results of rotationplasty for sarcomas of the distal femur over a 20-year period were analyzed, focusing on long-term survival, function, quality of life and mental health. Method. Retrospective study of 73 children who had a rotationplasty performed at two institutions between 1984 and 2007 for a bone sarcoma of the distal femur; 42 males and 31 females, mean age at surgery 8.7 yrs (range 3–17). Four patients were converted to transfemoral amputation due to early vascular complication; 25 eventually died of their disease (mean survival 34 months, range 4–127). The 46 remaining survivors were evaluated for updated clinical outcome, MSTS score, gait analysis, SF-36 score, quality of life interview and psychological assessment at mean follow-up of 15 yrs (range 3–23). Results. Overall survival was 64%. All the survivors were disease-free at last follow-up. Four patients required hardware revision for nonunion and subsequently healed. Three patients refused participation in the long-term follow-up study. Mean MSTS score was 79 (range 64–88). SF-36 score was obtained in 35 patients (age > 16); male patients showed a trend toward greater activity and vitality. Compared to age-group norms, rotationplasty scores were lower for physical activity level (p <0.05) and higher for general health perception (p = 0.05) and mental health (p < 0.05). Conclusion. Rotationplasty remains a durable reconstructive option with good long-term function and acceptable psychological impact for children with bone sarcomas of the distal femur


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 58 - 58
1 Dec 2014
Olivier A Briggs T Khan S Faimali M Johnston L Gikas P Skinner J Pollock R Aston W
Full Access

Introduction:

Distal femoral replacement is recognised as the optimum treatment for malignant distal femoral tumours. Aseptic loosening is known to be a major cause for failure in these implants. Studies have indicated that the HA coated collar promotes osteointegration and bony in growth. This study compares long term aseptic loosening in implants with HA coated collars to those without in the immature skeleton.

Objectives:

To assess the effect of HA coated collars on aseptic loosening in extendable distal femoral replacement prosthesis in the immature skeleton.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 20 - 20
10 Feb 2023
McDonald A Byrnes C Boyle M Crawford H
Full Access

Survival of sepsis has been documented worldwide, but little is documented about the long-term health outcomes of multifocal sepsis from acute musculoskeletal infection - the first study of its kind in New Zealand. Children admitted to the Paediatric Intensive Care Unit (PICU) from 1. st. January 2002 to 31. st. December 2017 with a musculoskeletal focus of infection were identified from hospital coding data. Notes review from discharge to present day determined survival and morbidity. Present-day clinical assessment of the musculoskeletal and respiratory systems along with questionnaires on health-related quality of life, mental health and sleep were performed. Seventy patients were studied. Seven children died acutely (five Pasifika and two Māori children) indicating 10% mortality. Long-term survival was favourable with no recorded deaths after discharge. Recurrence/chronic infection occurred in 23%, a mean of 1.1 year after discharge. Growth disturbance occurred in 18%, a mean of 3 years after discharge. The hip joint and proximal femur have the worst complications. Children under 2 years are most at risk of long-term disability. No patients had chronic respiratory illness beyond 90 days. Fifteen children had symptoms of acute neurological impairment, three of whom had permanent brain injury. Twenty-six survivors (41%) were assessed a mean of 8.2 years after discharge. Health-related quality of life scores were on par with normative data. Six patients and eight parents screened positive for moderate to severe post-traumatic stress disorder. Paediatric multifocal musculoskeletal sepsis can result in complex illness with long hospital stay and multi-organ complications. Māori and Pasifika children, those under two and those involving the proximal femur/or hip are most at risk. Other outcomes are favourable with no evidence of chronic lung disease or poor quality of life. A period of rehabilitation for children with identified acquired brain injury should be part of discharge planning


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 8 - 8
1 Nov 2022
Bharmal A Gokhale N Curtis S Prasad G Bidwai A Kurian J
Full Access

Abstract. Background. To determine the long-term survival outcomes of Copeland Resurfacing Hemiarthroplasty (CRHA) performed by a single surgeon series. Methods. A retrospective cohort study which looked at patients who underwent CRHA over 6 years. Re-operations including revisions with component exchange taking place in our hospital and at local centres were reviewed. Oxford Shoulder Score (OSS) was used to assess their functional outcomes pre- and post-CRHA. Results. 80 CRHAs were performed in 72 patients between 2007 and 2013 with a mean follow-up of 6.5 years. The mean follow-up was 79 months (50–122). The primary indication for CRHA was osteoarthritis (76.3%), cuff tear arthropathy (16.3%), rheumatoid arthritis (5%) and post-trauma (1.3%). The mean pre-operative OSS was 16, which doubled following CRHA surgery. Fifteen patients underwent revision surgery due to ongoing glenoid pain with a mean revision time following primary CRHA being 49 months. Projected survival at the endpoints 5,7 and 10 years were 83, 81 and 79% respectively. Conclusion. This study provides us with a much longer average follow-up period in comparison to many other studies published. Previous studies, support resurfacing as a useful implant in reducing pain and improving function in the short-term; but this series demonstrates over the medium-term a relatively high revision rate of about 20% in comparison with other arthroplasty options, despite the revision rate seeming to plateau from the 5-year mark onwards


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 57 - 57
1 Dec 2022
Gazendam A Ekhtiari S Wood T Petruccelli D Tushinski D Winemaker MJ de Beer J
Full Access

The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the long-term survival of this stem and analyze patients who underwent aseptic revision to understand the causes and risk factors for failure. A retrospective review was undertaken of all patients who received a primary total hip arthroplasty with an Accolade® TMZF stem at a high-volume arthroplasty center. The causes and timing of revision surgery were documented and cross referenced with the Canadian Institute of Health Information Discharge Abstract Database to minimize loss to follow-up. Survivorship analysis was performed with use of the Kaplan-Meier curves to determine the overall and aseptic survival rates at final follow-up. Patient and implant factors commonly associated with aseptic failure were extracted and Cox proportional hazards model was used. A consecutive series of 2609 unilateral primary THA patients implanted with an Accolade®TMZF femoral hip stem were included. Mean time from primary surgery was 12.4 years (range 22 days to 19.5 years). Cumulative survival was 96.1% ± 0.2 at final follow-up. One hundred and seven patients underwent revision surgery with aseptic loosening of the femoral component was the most common cause of aseptic failure in this cohort (33/2609, 1.3%). Younger age and larger femoral head offset were independent risk factors for aseptic failure. To our knowledge, this is the largest series representing the longest follow-up of this taper-wedge cementless femoral implant. Despite early concerns, the Accolade® TMZF stem has excellent survivorship in this cohort. Trunnionosis as a recognized cause for revision surgery was rare. Younger age and larger femoral head offset were independent risk factors for aseptic failure


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 79 - 79
1 Apr 2018
Lee W Han C Yang I Park K
Full Access

Introduction. Reinforcement ring with allograft bone is commonly used for acetabular reconstruction of bone defects because it can achieve stable initial fixation of the prosthesis. It is not clear whether the allograft bone can function as a viable host bone and provide long-standing structural support. The purpose of this study was to assess to long-term survival of the reinforcement rings and allograft bone incorporation after acetabular revisions. Methods. We retrospectively reviewed 39 hips (37 patients) who underwent reconstruction of the acetabulum with a Ganz reinforcement ring and allograft bone in revision total hip arthroplasty. There were 18 females and 19 males with a mean age of 55.9 years (35–74 years). The minimum postoperative follow-up period was 10 years (10∼17 years). We assessed the acetabular bone defect using the Paprosky's classification. We determined the rates of loosening of the acetabular reconstructions, time to aseptic loosening, integration of the allograft bone, resorption of the allograft bone, and survival rate. Aseptic loosening of the acetabular component was defined as a change in the cup migration of more than 5 mm or a change in the inclination angle of more than 5° or breakage of the acetabular component at the time of the follow-up. Graft integration was defined as trabecular remodelling crossing the graft-host interface. Resorption of the allograft bone was classified as minor (<1/3), moderate (1/3–1/2) or severe (>1/2). Kaplan-Meier survivorship analysis was performed for aseptic loosening of the acetabular component. The results. The acetabular bone defects were classified as follows: 8 type II hips (4 type IIB, 4 type IIC), and 31 type III hips (17 type IIIA, 14 type IIIB). Fourteen (35.9%) of 39 hips was defined as aseptic loosening of an acetabular component. Loosening was more frequent in type IIIB (57.1%) than in type IIIA hips (29.4%). Mean time to aseptic loosening of the acetabular reconstructions was 6.3 years in type IIIA and from 5 years in type IIIB defects, respectively. Allograft bone incorporation was satisfactory in 66.7% of hips. There was minor bone resorption in 14.3% and moderate bone resorption in 10.2%. In 9 hips (23.1%), severe resorption of the allograft bone was observed and early component loosening was observed in these cases. The survival rate of acetabular component at 10 years of follow-up was 63.6% (95% confidence interval, 49–77%) with aseptic loosening as endpoints. Conclusions. The long-term survival rate of acetabular revision using the reinforcement ring and allograft bone in the reconstruction of severe acetabular bone defects was unsatisfactorily low due to loosening of acetabular components. Because of unfavorable graft incorporation into a host bone, an alternative component and structural support may be employed in the reconstruction of severe acetabular bone defects


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 2 - 2
1 Aug 2020
Matache B King GJ Watts AC Robinson P Mandaleson A
Full Access

Total elbow arthroplasty (TEA) usage is increasing owing to expanded surgical indications, better implant designs, and improved long-term survival. Correct humeral implant positioning has been shown to diminish stem loading in vitro, and radiographic loosening in in the long-term. Replication of the native elbow centre of rotation is thought to restore normal muscle moment arms and has been suggested to improve elbow strength and function. While much of the focus has been on humeral component positioning, little is known about the effect of positioning of the ulnar stem on post-operative range of motion and clinical outcomes. The purpose of this study is to determine the effect of the sagittal alignment and positioning of the humeral and ulnar components on the functional outcomes after TEA. Between 2003 and 2016, 173 semi-constrained TEAs (Wright-Tornier Latitude/Latitude EV, Memphis, TN, USA) were performed at our institution, and our preliminary analysis includes 46 elbows in 41 patients (39 female, 7 male). Patients were excluded if they had severe elbow deformity precluding reliable measurement, experienced a major complication related to an ipsilateral upper limb procedure, or underwent revision TEA. For each elbow, saggital alignment was compared pre- and post-operatively. A best fit circle of the trochlea and capitellum was drawn, with its centre representing the rotation axis. Ninety degree tangent lines from the intramedullary axes of the ulna and humerus, and from the olecranon tip to the centre of rotation were drawn and measured relative to the rotation axis, representing the ulna posterior offset, humerus offset, and ulna proximal offset, respectively. In addition, we measured the ulna stem angle (angle subtended by the implant and the intramedullary axis of the ulna), as well as radial neck offset (the length of a 90o tangent line from the intramedullary axis of the radial neck and the centre of rotation) in patients with retained or replaced radial heads. Our primary outcome measure was the quickDASH score recorded at the latest follow-up for each patient. Our secondary outcome measures were postoperative flexion, extension, pronation and supination measured at the same timepoints. Each variable was tested for linear correlation with the primary and secondary outcome measures using the Pearson two-tailed test. At an average follow-up of 6.8 years (range 2–14 years), there was a strong positive correlation between anterior radial neck offset and the quickDASH (r=0.60, p=0.001). There was also a weak negative correlation between the posterior offset of the ulnar component and the qDASH (r=0.39, p=0.031), and a moderate positive correlation between the change in humeral offset and elbow supination (r=0.41, p=0.044). The ulna proximal offset and ulna stem angle were not correlated with either the primary, or secondary outcome measures. When performing primary TEA with radial head retention, or replacement, care should be taken to ensure that the ulnar component is correctly positioned such that intramedullary axis of the radial neck lines up with the centre of elbow rotation, as this strongly correlates with better function and less pain after surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 77 - 77
1 Feb 2020
Ramirez-Martinez I Smith S Trail I Joyce T
Full Access

Introduction. Despite the positive outcomes in shoulder joint replacements in the last two decades, polyethylene wear debris in metal-on-polyethylene artificial shoulder joints is well-known as a limitation in the long-term survival of shoulder arthroplasties systems. Consequently, there is an interest in the use of novel materials as an alternative to hard bearing surfaces such as pyrolytic carbon layer (PyroCarbon). Materials and Methods. In the present study, the unique Newcastle Shoulder Wear Simulator was used (Smith et al., 2015; Smith et al., 2016) to evaluate the wear behavior of four commercially available PyroCarbon humeral heads 43 mm diameter, articulating against conventional ultra-high molecular weight polyethylene (UHMWPE) glenoid inserts with a radius of curvature of 17.5 mm to form an anatomic total shoulder arthroplasty. A physiological combined cycled “Repeat-motion-load” (RML) (Ramirez-Martinez et al., 2019) obtained from the typical activities of daily life of patients with shoulder implants was applied as a simulator input. A fifth sample of the same size and design was used as a soak control and subjected to dynamic loading without motion during the wear test. The mean volumetric wear rate of PyroCarbon-on-polyethylene was evaluated over 5 million cycles gravimetrically and calculated on the basis of linear regression, as well as the change in surface roughness (S. a. ) of the components using a non-contacting white light profilometer throughout the test. Results. The gravimetric analysis showed a mean volumetric wear rate and standard deviation of 19.3±9.5 mm. 3. /million cycles for the UHMWPE glenoid inserts, whereas PyroCarbon humeral head counterparts did not exhibit a loss in mass throughout the test. The roughness values of the UHMWPE glenoid inserts decreased (P < .001), changing from 296±28 nm to 32±8 nm at the end of the test. In contrast, the PyroCarbon humeral heads did not show a significant change (P = .855) over the 5 million cycles; remained in the same range (21±2 nm to 20±10 nm) with no evidence of wear damage on the surface. Conclusions. This is the first in-vitro shoulder simulator study of a PyroCarbon on UHMWPE articulation. Wear rates were similar to that found to well-proven metal on UHMWPE shoulder arthroplasties. While it was interesting to see that the PyroCarbon did not roughen over the test duration, the lack of an appreciable reduction in wear of the UHMWPE component when articulated with an expensive and complex to manufacture PyroCarbon component likely means there is little clinical cost-benefit in the use of a PyroCarbon on UHMWPE shoulder implant. Declaration of competing interest. Prof. Ian A. Trail received some royalties and research support from Wright Medical Group N.V. None of the other authors, their immediate families, and any research foundation with which they are affiliated did not receive any financial payments or other benefits from any commercial entity related to the subject of this article. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 75 - 75
1 May 2019
Gehrke T
Full Access

Total hip arthroplasty has become one of the most successful orthopaedic procedures with long-term survival rate. An ever-increasing acceptance of the potential longevity of THA systems has contributed to an increasing incidence of THA in younger and more active patients. Nowadays, especially in younger patients, cementless THA is the favored method worldwide. Since the first cementless THA in late 1970s, many implant designs and modifications have been made. Despite excellent long-term results for traditional straight cementless stems, periprosthetic fractures or gluteal insufficiency are still a concern. For instance, as reported in a meta-analysis by Masonis and Bourne, the incidence of gluteal insufficiency after THA varies between 4% and 22%. In contrast, the flattened lateral profile of the SP-CL. ®. anatomical cementless stem can protect the greater trochanter during the use of cancellous bone compressors and can avoid gluteal insufficiency after THA. Another benefit of this stem design is the rotational stability and the natural load transfer due to the anatomical concept. In this context, we report our experiences using the SP-CL. ®. anatomical cementless stem. The study group consists of 1452 THA cases (850 male, 602 female) with an average age of 62 years (range 25–76 years). After a mean follow-up of 20 months, in seven cases (0.5%) a stem exchange was necessitated. The reason for stem revision was periprosthetic fracture in 4 cases (0.3%) and periprosthetic joint infection in three cases (0.2%). In five patients, hip dislocation and in four patients migration of the stem occurred. However, stem exchange was not required in those cases. In conclusion, the SP-CL. ®. anatomical cementless stem has excellent short-term results


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 11 - 11
1 May 2012
L. P C. H L. S A. K H. W N. H W. VDT R. C
Full Access

Introduction. The management of degenerative arthritis of the knee in the younger, active patient presents a challenge to the orthopaedic surgeon. Surgical treatment options include: high tibial osteotomy (HTO), unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The aim of this study was to examine the long-term survival of closing wedge HTO in a large series of patients up to 19 years after surgery. Methods. Four hundred and fifty-five consecutive patients underwent lateral closing wedge HTO for medial compartment osteoarthritis (MCOA) between 1990 and 2001. Between 2008-2009, patients were contacted via telephone. Assessment included: incidence of further surgery, current body mass index (BMI), Oxford Knee Score, and British Orthopaedic Association (BOA) Patient Satisfaction Scale. Failure was defined as the need for revision HTO or conversion to UKA or TKA. Survival analysis was completed using the Kaplan-Meier method. Results. High tibial osteotomy survival was determined on 413 patients (91%) and, of the 397 patients who were alive at the time of final review, 394 (99%) were contacted for follow-up via telephone interview. The probability of survival for HTO at 5, 10 and 15 years was: 95%, 79% and 56% respectively. Multivariate regression analysis showed that age < 50 years (p=0.001), BMI < 25 kg/m. 2. (p=0.006) and ACL deficiency (p=0.03) were associated with better odds of survival. Mean Oxford Knee Score was 40/48 (range 17-48). Overall, 85% of patients were enthusiastic or satisfied and 84% would undergo HTO again at mean 12 years follow-up. Conclusion. High tibial osteotomy can be effective for periods longer than 15 years. However, results do deteriorate over time. Age < 50 years, normal BMI and ACL deficiency were independent factors associated with improved long-term survival of HTO


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 15 - 15
1 Apr 2019
Ramirez-Martinez I Smith S Joyce T
Full Access

INTRODUCTION. Shoulder joint prostheses have become the most commonly replaced after knee and hip artificial implants. Reverse shoulder arthroplasty (RSA) is the treatment option for patients with severe osteoarthritis, rotator cuff arthropathy or a massive rotator cuff tear with pseudoparalysis. Though successful, the long-term survival of such implants are limited by wear of the materials in contact [1, 2]. The aim of this study was to investigate RSA wear in vitro using a clinically relevant activities of daily living (ADLs). MATERIALS AND METHODS. Four new JRI Orthopaedics Reverse Shoulder 42 mm diameter VAIOS with cobalt-chromium (CoCr) glenospheres and ultra-high molecular weight polyethylene (UHMWPE) humeral components were tested. A five million cycles wear test was undertaken using the unique Newcastle Shoulder Wear Simulator with dilute bovine serum as a lubricant. “Mug to mouth” was performed as the ADL to the test prostheses in intervals of 100 cycles, following by 5 seconds of high load (450N) with no motion simulating an ADL such as “lifting an object”. This combined load cycle was then repeated. A fifth reverse shoulder prosthesis was subject to dynamic loading only in a soak control station. Wear was assessed gravimetrically and roughness (Sa) of the articulating surfaces was measured with a non-contacting profilometer. RESULTS AND DISCUSSION. The mean wear rate and standard deviation of the UHMWPE components was 11.4±3.7 mm. 3. /million cycles, while the CoCr components showed minimal wear over the test duration of 0.01± 0.02 mm. 3. /million cycles (Fig.1). Wear rates are comparable with Kohut et al. (14.1 mm. 3. /million cycles) [3] and Smith et al. (14.3±1.6 mm. 3. /million cycles) [4]. The CoCr glenospheres roughness was unchanged, from 32±8 nm Sa to 28±8 nm Sa over the 5 million cycles of the test (p=0.017), while the UHMWPE humeral components became smoother, from 692±123 nm Sa to 42±29 nm Sa (Fig.2), showing a statically significant change (p<0.001). CONCLUSION. The present study is the first wear test of artificial shoulder joints using a Motion-Load-Motion configuration as a clinically relevant physiological pattern of motion and load. Results are comparable with those found in the literature for in vitro testing of reverse shoulder replacements. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 343 - 343
1 Mar 2013
Sugano N Takao M Sakai T Nishii T Nakahara I Miki H
Full Access

Although there are several reports of excellent long-term survival after cemented total hip arthroplasty (THA), cemented acetabular components are prone to become loose when compared with femoral components. On the other hand, the survival of cementless acetabular components has been reported to be equal or better than cemented ones and the use of cementless acetabular components is increasing. However, most of the reports on survival after THA are for patients with primary hip osteoarthritis (OA) and there is no report of 20-year survival of cementless THA for patients with hip dysplasia. It is supposed to be more difficult to fix cementless acetabular components for OA secondary to hip dysplasia than primary OA. The purposes of this study were to review retrospectively the 20-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the long-term survival for patients with hip dysplasia. We retrospectively reviewed all patients with OA secondary to hip dysplasia treated with a cemented Bioceram hip system between 1981 and 1987, and a cementless cancellous metal Lübeck hip system between 1987 and 1991. We excluded patients aged more than 60 years, males, and Crowe 4 hips. The studied subjects were 70 hips of cemented THA (Group-C) and 57 hips of cementless THA (Group-UC). Both hip implants had a 28-mm alumina head on polyethylene articulation. The mean age at operation was 50.5 years (range, 36–60 years) in Group-C and 50.0 years (range, 29–60 years) in Group-UC. The mean BMI was 23.2 kg/m. 2. in Group-C (range, 17.3–29.3 kg/m. 2. ) and 22.9 kg/m. 2. in Group-UC (range, 18.8–28.0 kg/m. 2. ). There were no significant differences in age and BMI between the two groups. The average follow-up period was 18.0 years in Group-C and 18.4 years in Group-UC. In Group-C, revision was performed in 33 hips due to aseptic cup loosening (30 hips), stem loosening (one hip), and loosening of both components (two hips). In Group-UC, revision was performed in 10 hips due to stem fracture secondary to distal fixation (4 hips), cup loosening (three hips), polyethylene breakage (two hips), and extensive osteolysis around the stem (one hip). The survival at 20 years regarding any revision as the endpoint was 51% in Group-C and 84% in Group-UC. This difference was significant using Log-rank test (P=0.006). The cup survival at 20 years was 54% in Group-C and 92% in Group-UC. This difference was also significant (P = 0.0003). The stem survival at 20 years was 95% in Group-C and 92% in Group-UC. This difference was not significant (P = 0.4826). Cementless THA showed a higher survival rate at 20 years for hip dysplasia than cemented THA because of the excellent survival of the acetabular component without cement. We conclude that cementless THA with the cancellous metal Lübeck hip system led to better longevity at 20 years than cemented THA with the Bioceram for patients with OA secondary to hip dysplasia


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 52 - 52
1 Feb 2021
De Grave PW Luyckx T Claeys K Gunst P
Full Access

Purpose. Various alignment philosophies for total knee arthroplasty (TKA) have been described, all striving to achieve excellent long-term implant survival and good functional outcomes. In recent years, in search of higher functionality and patient satisfaction, a shift towards more patient-specific alignment is seen. Robotics is the perfect technology to tailor alignment. The purpose of this study was to describe ‘inverse kinematic alignment’ (iKA) technique, and to compare clinical outcomes of patients that underwent robotic-assisted TKA performed by iKA versus adjusted mechanical alignment (aMA). Methods. The authors analysed the records of a consecutive series of patients that received robotic assisted TKA with iKA (n=40) and with aMA (n=40). Oxford Knee Score (OKS) and satisfaction on a visual analogue scale (VAS) were collected at a follow-up of 12 months. Clinical outcomes were assessed according to patient acceptable symptom state (PASS) thresholds, and uni- and multivariable linear regression analyses were performed to determine associations of OKS and satisfaction with 6 variables (age, sex, body mass index (BMI), preoperative hip knee ankle (HKA) angle, preoperative OKS, alignment technique). Results. The iKA and aMA techniques yielded comparable outcome scores (p=0.069), with OKS respectively 44.6±3.5 and 42.2±6.3. VAS Satisfaction was better (p=0.012) with iKA (9.2±0.8) compared to aMA (8.5±1.3). The number of patients that achieved OKS and satisfaction PASS thresholds was significantly higher (p=0.049 and p=0.003, respectively) using iKA (98% and 80%) compared to aMA (85% and 48%). Knees with preoperative varus deformity, achieved significantly (p=0.025) better OKS using iKA (45.4±2.0) compared to aMA (41.4±6.8). Multivariable analyses confirmed better OKS (β=3.1; p=0.007) and satisfaction (β=0.73; p=0.005) with iKA. Conclusions. The results of this study suggest that iKA and aMA grant comparable clinical outcomes at 12-months follow-up, though a greater proportion of knees operated by iKA achieved the PASS thresholds for OKS and satisfaction. Notably. in knees with preoperative varus deformity, iKA yielded significantly better OKS and satisfaction than aMA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 23 - 23
1 Mar 2017
Sugano N Nakahara I Hamada H Takao M Sakai T Ohzono K
Full Access

The purposes of this study were to review retrospectively the 25-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the long-term survival in patients with DDH. We retrospectively reviewed all patients with OA secondary to hip dysplasia treated with a cemented Bioceram hip system between 1981 and 1987, and a cementless cancellous metal Lübeck hip system between 1987 and 1991. The studied subjects were 76 hips of cemented THA (Group-C) and 57 hips of cementless THA (Group-UC). Both hip implants had a 28-mm alumina head on polyethylene articulation. The mean age at operation was 50.5 years (range, 36–60 years) in Group-C and 50.0 years (range, 29–60 years) in Group-UC. The survival at 25 years regarding any revision as the endpoint was 46% in Group-C and 76% in Group-UC. These difference was significant using Log-rank test (P=0.008). The cup survival at 25 years was 47% in Group-C and 83% in Group-UC (P= 0.0003). The stem survivals at 25 years were 95% in Group-C and 92% in Group-UC. (P= 0.416). Cementless THA in patients with DDH showed a higher survival rate at 25 years than cemented THA because of the excellent survival of the acetabular component without cement. We conclude that cementless THA with the cancellous metal Lübeck hip system led to better longevity at 25 years than cemented THA with the Bioceram in patients with OA secondary to DDH


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 88 - 88
1 Dec 2016
Greidanus N Konan S Duncan C Masri B Garbuz D
Full Access

In revision total hip arthroplasty (THA), acetabular reconstruction while dealing with severe bone loss is a challenge. The porous tantalum revision acetabular shells have been in use for the past decade. Several reports have documented successful use at early to mid-term follow up. There is, however, very little literature around the long-term survival and quality of life outcome with the use of these shells. We reviewed the results of 46 acetabular revisions with Paprosky 2 and 3 acetabular bone defects reconstructed with a hemispheric, tantalum acetabular shell and multiple supplementary screws. There were 31 females. Average age at revision was 64 years (range 23–85 years). The mean and median follow up was 11 years (range 10–12 years, SD 1). Morselised femoral allograft was used in 34 hips to fill contained cavitary defectes. Bulk femoral allografting was performed in 2 hips. At a minimum follow-up of 10 (range 10–12) years, the survivorship of the porous tantalum acetabular shell, with revision of the shell as end point was 96%. The minimum 10-year survivorship with hip revision for any reason as end point was 92%. We noted excellent pain relief (mean WOMAC pain 92.6) and good functional outcome (mean WOMAC function 90.3, mean UCLA 5); and generic quality of life measures (mean SF-12 physical component 48.3; mean SF-12 mental component 56.7). Patient satisfaction with pain relief, function and return to recreational activities were noted to be excellent. Cementless acetabular revision with the tantalum acetabular shell demonstrated excellent clinical and quality of life outcomes at minimum 10-year follow-up. As far as we are aware this is the first report of minimum 10-year follow up of use of this technique for revision hip arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 40 - 40
1 Nov 2016
Lachiewicz P
Full Access

Wear of the tibial polyethylene liner of total knee arthroplasty (TKA) is complex and multifactorial. The issues involved include those of implant design and locking mechanism, surgical-technical variability, and patient weight and activity level. However, tibial polyethylene fabrication, including bar stock, amount of irradiation, quenching of free radicals, and sterilization may also be factors in the long-term survival of TKA. Highly crosslinked polyethylene is now widely used in total hip arthroplasty, but its value and use in TKA is a subject of great controversy. In making a decision to use these products, the surgeon should consider multiple sources of evidence: in-vitro wear testing; clinical cohort studies; randomised controlled trials; registry survival data; and retrieval analyses. The two questions to be asked are: is there a value or benefit in the use of these new polyethylenes, and what are the risks involved with the use of these products?. Laboratory testing, generally to 5 million cycles, has shown a significant decrease in tibial polyethylene wear of several products, with both cruciate-retaining and substituting designs, and under adverse conditions. Retrospective cohort studies and RCTs comparing conventional and highly crosslinked polyethylene have shown little difference between the two products at mean follow-up times of 5 years. One registry study showed no difference in the rate of revision at short-term follow-up, but the Australian Joint Replacement Registry in 2014 did report a decreased rate of revision for loosening and osteolysis in “young patients” with one particular tibial polyethylene. The risks of the use of highly crosslinked polyethylene include fracture (the tibial liner, PS post, and patella pegs), and particle size-reactivity. However, these risks appear to be quite low. Retrieval data shows lower damage scores with certain polyethylenes, and variable changes in the oxidation score. At present, the data does not support the widespread or routine use of highly crosslinked or antioxidant polyethylene in TKA. However, consideration should be given for use of certain products in young and active patients. Longer-term follow-up will ultimately determine the role of highly crosslinked polyethylene in TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 77 - 77
1 Feb 2017
Kobayashi K Okaniwa D Sakamoto M Tanabe Y Sato T Omori G Koga Y
Full Access

Three-dimensional (3D) weight-bearing alignment of the lower extremity is crucial for understanding biomechanics of the normal and pathological functions at the hip, knee, and ankle joints. In addition, implant position with reference to bone is a critical factor affecting the long-term survival of artificial joints. The purpose of this study was to develop a biplanar system using a slot-scan radiography (SSR) for assessing weight-bearing alignment of the lower extremity and for assessing implant positioning with respect to bone. A SSR system (Sonial Vision Safire 17, Shimadzu, Kyoto, Japan) with a custom-made rotation table was used to capture x-ray images at 0 deg and 60 deg relative to the optical axis of an x-ray source [Fig.1]. The SSR system uses collimated fan beam x-rays synchronized with the movement of a flat-panel detector. This system allows to obtain a full length x-ray image of the body with reduced dose and small image distortion compared with conventional x-ray systems. Camera calibration was performed beforehand using an acrylic reference frame with 72 radiopaque markers to determine the 3D positions of the x-ray source and the image plane in the coordinate system embedded in the reference frame. Sawbone femur and tibia and femoral components of the Advance total knee system (Wright Medical Technology, Arlington, TN, USA) were used. Computed tomography of the sawbone femur and tibia was performed to allow the reconstruction of the 3D surface models. For the component, the computer aided design (CAD) model provided by the manufacturer was used. Local coordinate system of each surface model was defined based on central coordinates of 3 reference markers attached to each model. The sawbone femur and tibia were immobilized at extension, axial rotation, and varus deformity and were imaged using the biplanar SSR system. The 3D positions of the femur and tibia were recovered using an interactive 2D to 3D image registration method [Fig.2]. Then, the femoral component was installed to the sawbone femur. The 3D positions of the femur and femoral component were recovered using the above-mentioned image registration method. Overall, the largest estimation errors were 1.1 mm in translation and 0.9 deg in rotation for assessing the alignment, and within 1 mm in translation and 1 deg in rotation for assessing the implant position, demonstrating that this method has an adequate accuracy for the clinical usage


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 144 - 144
1 Mar 2017
Seol Y Park K Yoon T
Full Access

Background. Need for hip or knee arthroplasty is rapidly increasing in aging society nowadays. Accordingly, orthopedic surgeries for patients with various diseases of high mortality rates are becoming indispensable. Patients with liver cirrhosis undergoing major orthopedic surgery like joint arthroplasty are at risk of many complications including infection and excessive bleeding. In this study, we want to present helpful measures to prevent expected complications that can occur with hip or knee arthroplasty performed on patients with liver cirrhosis through comparative analysis on the prognosis of relevant patients studied at our hospitals. Patients and method. The study involves a retrospective comparison on 210 patients who underwent hip (71 patients) or knee (138 patients) arthroplasty in Chonnam National University Hospital, Hwasun Chonnam National University Hospital or Chonnam National University Bitgoeul Hospital. Prognoses of patients with underlying disease of liver cirrhosis and those without are compared with measures of amount of bleeding, transfer to an intensive care unit or medical department, duration of hospital stay, readmission within 30 days, 90 days and post-operative complication. To find out the rationale behind the differences in prognosis between these two groups, comparisons on total surgical time and blood loss during surgery were made. Also, the objectivity of the surgical treatment at our hospitals was ensured through comparing the postoperative short- and long-term mortality rates of the patients with liver cirrhosis who underwent hip or knee arthroplasty at our hospitals. Results. Among patients who underwent hip or knee arthroplasty, those with underlying condition of the liver cirrhosis show an increase in amount of bleeding, duration of hospital stay, number of blood transfusion, infection rate and a decrease in long-term survival rate compared to those who do not have liver cirrhosis. It was found that all of these factors were differed with severity of liver cirrhosis (measured according to Child-Pugh Score) and combined another disease (CRF) and became more profound when severity of liver cirrhosis increased. Conclusion. It was possible to show that the risk of arthroplasty on patients with liver cirrhosis is much higher than on cases of normal patients. Performing arthroplasty on patients with liver cirrhosis seems to put them under higher risk of increased blood loss and infection rates. Therefore, it is advised to prepare adequate preoperative and postoperative medical care, decrease surgical time and bleeding loss when performing hip or knee arthroplasty on patients with cirrotic liver disease