Increased femoral head size reduces the rate of dislocation after total hip arthroplasty (THA). With the introduction of highly crosslinked polyethylene (HXLPE) liners in THA there has been a trend towards using larger size femoral heads in relatively smaller cup sizes, theoretically increasing the risk of liner fracture, wear, or aseptic loosening. Short to medium follow-up studies have not demonstrated a negative effect of using thinner HXLPE liners. However, there is concern that these thinner liners may prematurely fail in the long-term, especially in those with thinner liners. The aim of this study was to evaluate the
Purpose. Long-term clinical and radiographic results and survival rates were compared between closed-wedge high tibial osteotomy (HTOs) and fixed-bearing unicompartmental knee arthroplasty (UKA) in patients with similar demographics. Methods. Sixty HTOs and 50 UKAs completed between 1992 and 1998 were retrospectively reviewed. There were no significant differences in preoperative demographics. The mean follow-up period was 10.7 ±5.7 years for HTO and 12.0 ±7.1 years for UKA (n.s.). The Knee Society knee and function scores, WOMAC, and range of motion (ROM) were investigated. The mechanical axis and femorotibial angle were evaluated. Kaplan–Meier survival analysis was performed (failure: revision to TKA), and the failure modes were investigated. Results. Most of the clinical and radiographic results were not different at the last follow-up, except ROM; ROM was 135.3 ±12.3° in HTO and 126.8 ±13.3° in UKA (p=0.005). The 5-, 10-, 15-, and 20-year survival rates were 100%, 91.0%, 63.4%, and 48.3% for closed-wedge HTO, respectively, and 90.5%, 87.1%, 70.8%, and 66.4% for UKA (n.s.). The survival rate was higher than that for UKA until 12 years postoperatively but was higher in UKAs thereafter, following a remarkable decrease in HTO. The most common failure mode was degenerative osteoarthritic progression of medial compartment in HTO and femoral component loosening in UKA. Conclusions.
Purpose. Rotationplasty was first described in 1930 by Borggreve for treatment of limb shortening with knee ankylosis after tuberculosis. In 1948, Van Nes described its use for management of congenital defects of the femur and in the 1980s, Kotz and Salzer reported on patients with malignant bone tumors around the knee treated by rotationplasty as an alternative to above-knee amputation. Currently, rotationplasty is one of the options for surgical management of lower extremity bone sarcomas in skeletally immature patients but alternative limb salvage techniques, such as the use of expandable endoprosthesis, are also available. Despite rather satisfactory functional results have been uniformly associated with rotationplasty, concern still exists about the potential psychological impact of the new body imagerelated to the strange appearance of the rotated limb. Results of rotationplasty for sarcomas of the distal femur over a 20-year period were analyzed, focusing on
Distal femoral replacement is recognised as the optimum treatment for malignant distal femoral tumours. Aseptic loosening is known to be a major cause for failure in these implants. Studies have indicated that the HA coated collar promotes osteointegration and bony in growth. This study compares long term aseptic loosening in implants with HA coated collars to those without in the immature skeleton. To assess the effect of HA coated collars on aseptic loosening in extendable distal femoral replacement prosthesis in the immature skeleton.Introduction:
Objectives:
Survival of sepsis has been documented worldwide, but little is documented about the long-term health outcomes of multifocal sepsis from acute musculoskeletal infection - the first study of its kind in New Zealand. Children admitted to the Paediatric Intensive Care Unit (PICU) from 1. st. January 2002 to 31. st. December 2017 with a musculoskeletal focus of infection were identified from hospital coding data. Notes review from discharge to present day determined survival and morbidity. Present-day clinical assessment of the musculoskeletal and respiratory systems along with questionnaires on health-related quality of life, mental health and sleep were performed. Seventy patients were studied. Seven children died acutely (five Pasifika and two Māori children) indicating 10% mortality.
Abstract. Background. To determine the
The Accolade®TMZF is a taper-wedge cementless metaphyseal coated femoral stem widely utilized from 2002-2012. In recent years, there have been reports of early catastrophic failure of this implant. Establishing a deeper understanding of the rate and causes of revision in patients who developed aseptic failure in stems with documented concerns about high failure rates is critical. Understanding any potential patient or implant factors which are risk factors for failure is important to inform both clinicians and patients. We propose a study to establish the
Introduction. Reinforcement ring with allograft bone is commonly used for acetabular reconstruction of bone defects because it can achieve stable initial fixation of the prosthesis. It is not clear whether the allograft bone can function as a viable host bone and provide long-standing structural support. The purpose of this study was to assess to
Total elbow arthroplasty (TEA) usage is increasing owing to expanded surgical indications, better implant designs, and improved
Introduction. Despite the positive outcomes in shoulder joint replacements in the last two decades, polyethylene wear debris in metal-on-polyethylene artificial shoulder joints is well-known as a limitation in the
Total hip arthroplasty has become one of the most successful orthopaedic procedures with
Introduction. The management of degenerative arthritis of the knee in the younger, active patient presents a challenge to the orthopaedic surgeon. Surgical treatment options include: high tibial osteotomy (HTO), unicompartmental knee arthroplasty (UKA) and total knee arthroplasty (TKA). The aim of this study was to examine the
INTRODUCTION. Shoulder joint prostheses have become the most commonly replaced after knee and hip artificial implants. Reverse shoulder arthroplasty (RSA) is the treatment option for patients with severe osteoarthritis, rotator cuff arthropathy or a massive rotator cuff tear with pseudoparalysis. Though successful, the
Although there are several reports of excellent
Purpose. Various alignment philosophies for total knee arthroplasty (TKA) have been described, all striving to achieve excellent
The purposes of this study were to review retrospectively the 25-year survival of cemented and cementless THA for hip dysplasia and to compare the effect of fixation methods on the
In revision total hip arthroplasty (THA), acetabular reconstruction while dealing with severe bone loss is a challenge. The porous tantalum revision acetabular shells have been in use for the past decade. Several reports have documented successful use at early to mid-term follow up. There is, however, very little literature around the
Wear of the tibial polyethylene liner of total knee arthroplasty (TKA) is complex and multifactorial. The issues involved include those of implant design and locking mechanism, surgical-technical variability, and patient weight and activity level. However, tibial polyethylene fabrication, including bar stock, amount of irradiation, quenching of free radicals, and sterilization may also be factors in the
Three-dimensional (3D) weight-bearing alignment of the lower extremity is crucial for understanding biomechanics of the normal and pathological functions at the hip, knee, and ankle joints. In addition, implant position with reference to bone is a critical factor affecting the
Background. Need for hip or knee arthroplasty is rapidly increasing in aging society nowadays. Accordingly, orthopedic surgeries for patients with various diseases of high mortality rates are becoming indispensable. Patients with liver cirrhosis undergoing major orthopedic surgery like joint arthroplasty are at risk of many complications including infection and excessive bleeding. In this study, we want to present helpful measures to prevent expected complications that can occur with hip or knee arthroplasty performed on patients with liver cirrhosis through comparative analysis on the prognosis of relevant patients studied at our hospitals. Patients and method. The study involves a retrospective comparison on 210 patients who underwent hip (71 patients) or knee (138 patients) arthroplasty in Chonnam National University Hospital, Hwasun Chonnam National University Hospital or Chonnam National University Bitgoeul Hospital. Prognoses of patients with underlying disease of liver cirrhosis and those without are compared with measures of amount of bleeding, transfer to an intensive care unit or medical department, duration of hospital stay, readmission within 30 days, 90 days and post-operative complication. To find out the rationale behind the differences in prognosis between these two groups, comparisons on total surgical time and blood loss during surgery were made. Also, the objectivity of the surgical treatment at our hospitals was ensured through comparing the postoperative short- and long-term mortality rates of the patients with liver cirrhosis who underwent hip or knee arthroplasty at our hospitals. Results. Among patients who underwent hip or knee arthroplasty, those with underlying condition of the liver cirrhosis show an increase in amount of bleeding, duration of hospital stay, number of blood transfusion, infection rate and a decrease in