Advertisement for orthosearch.org.uk
Results 1 - 20 of 24
Results per page:
The Bone & Joint Journal
Vol. 97-B, Issue 10 | Pages 1328 - 1337
1 Oct 2015
Briant-Evans TW Lyle N Barbur S Hauptfleisch J Amess R Pearce AR Conn KS Stranks GJ Britton JM

We investigated the changes seen on serial metal artefact reduction magnetic resonance imaging scans (MARS-MRI) of metal-on-metal total hip arthroplasties (MoM THAs). In total 155 THAs, in 35 male and 100 female patients (mean age 70.4 years, 42 to 91), underwent at least two MRI scans at a mean interval of 14.6 months (2.6 to 57.1), at a mean of 48.2 months (3.5 to 93.3) after primary hip surgery. Scans were graded using a modification of the Oxford classification. Progression of disease was defined as an increase in grade or a minimum 10% increase in fluid lesion volume at second scan. A total of 16 hips (30%) initially classified as ‘normal’ developed an abnormality on the second scan. Of those with ‘isolated trochanteric fluid’ 9 (47%) underwent disease progression, as did 7 (58%) of ‘effusions’. A total of 54 (77%) of hips initially classified as showing adverse reactions to metal debris (ARMD) progressed, with higher rates of progression in higher grades. Disease progression was associated with high blood cobalt levels or an irregular pseudocapsule lining at the initial scan. There was no association with changes in functional scores. Adverse reactions to metal debris in MoM THAs may not be as benign as previous reports have suggested. Close radiological follow-up is recommended, particularly in high-risk groups.

Cite this article: Bone Joint J 2015;97-B:1328–37.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 46 - 46
1 Oct 2020
McConnell Z Stambough J Wilson B Barnes CL Mears S
Full Access

Introduction. Modular neck (MN) components in total hip arthroplasty (THA) offer intraoperative flexibility, but adverse local tissue reactions (ALTR) due to tribocorrosion at modular junctions are a potential complication of such designs. Serum ion levels and metal artifact reduction sequence (MARS) MRI are used to assess ALTR following modular THA. This study investigates serum ion levels and MARS MRI findings in a series of hips with MN components and differing articulating surfaces. Methods. We retrospectively evaluated a cohort of 184 primary THAs in 159 patients implanted with a dual modular femoral stem by one surgeon from 2005–2013. 121 THAs had a cobalt-chromium neck component and non-metal-on-metal articulation, while 63 THAs had a titanium neck component and metal-on-metal (MoM) articulation. Serum ion levels were recorded for all patients. MARS MRI scans were read by musculoskeletal-trained radiologists. Pseudotumor grade and location were measured. Results. Serum cobalt levels as a function of time post-operatively demonstrated no correlation. In THAs with non-MoM articulation, pseudotumors were visualized in 13 of 54 (24.1%) initial MARS MRIs performed 1–40 months post-operatively compared to 5 of 67 (7.5%) performed 41–120 months post-operatively (p=0.02), and findings typically remained consistent across multiple MARS MRI scans. Pseudotumors were generally located lateral to the hip joint in hips with non-MoM articulation compared to anteromedial following MoM arthroplasty. In the cobalt-chrome MN group, cobalt levels were elevated in 11 of 20 (55%) of patients with pseudotumor compared to 15 of 19 (79%) in the MoM group. Conclusion. Generation of ALTR leading to pseudotumor formation is a concern with cobalt-chrome MN designs. Psuedotumor characteristics differ between patients with cobalt-chrome designs versus MoM articulation. Normal serum ion levels did not exclude the presence of a pseudotumor and routine MARS MRI should be included in follow-up of patients with cobalt-chromium MN prostheses


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 38 - 38
1 Jul 2020
Govaers K Philips T Vandekelft A
Full Access

We report on a cadaveric study and early experience using patient specific drill guides to prevent cortex perforations and reduce the need for a trochanteric osteotomy in revision THA. Mimic software (Materialise) was used for 3D analysis of the cement mantle and cement plug. Based on the CT findings a Cannulated drill guide with the shape of the femoral stem was printed in medical graded nylon intraoperative findings and complications were recorded on videotape using a standard 5mm laparoscope for medullary inspection. Surgical Technique was to attain a pre-operative CT scan with MARS protocol of the proximal femur to evaluate the femoral stem positioning, the 3D anatomy of the cement mantle, the length of the cement plug and the quality of the surrounding bone. Subsequent a 3D printing of patient specific cannulated drill guide with the shape of the removed femoral component but an eccentric cannulation was made. Endoscopic inspection was performed of the inside of the cement mantle, then insertion of the autoclaved cannulated drill guide in the existing cement mantle. After perforation of the distal plug through the PSI drill guide using either a long drill or an ultrasound plug perforation tool (Zimmer Biomet, Warsaw) the excessive cement was removed with standard available flexible femoral shaft reamers (Zimmer Biomet). Further laproscopic examination of the femoral canal performed to verify completeness of the cement removal. Results. CT scans with 3D reconstruction of the existing cement mantle is possible using Modern CT with MARS protocols. After the training on sawbones and cadaveric bones a predictable plug perforation was obtained in all clinical cases. There were no intraoperative cortex perforations and no intraoperative femoral fractures. Conclusion. CT scan analysis of femoral cement mantles together with patient specific drill guides are promising tools to reduce the risk of femoral perforation in revision total hip arthroplasty


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 10 - 10
1 Oct 2019
Kwon Y An S Limmahakhun S Arauz P Klemt C
Full Access

Background. Adverse local tissue reactions (ALTR) in metal-on-polyethylene (MoP) total hip arthroplasty (THA) with head-neck taper corrosion is likely to be multifactorial involving implant and patient factors. However, there is a paucity of clinical data on implant parameters as predisposing factors in MoP head-neck taper corrosion. The aim of this study was to identify any potential implant factors associated with failed MoP THA due to head-neck taper corrosion. Methods. A total of 67 MoP THA patients in two groups was investigated: 1) ALTR (n=38) on MARS MRI and 2) non-ALTR (n=29) on MARS MRI. All patients had highly cross-linked polyethylene liners with cobalt-chromium femoral heads with a single head-neck modularity. Parameters compared between groups included: acetabular component orientation, femoral neck shaft angle, radiographic measurement of medial and vertical femoral offsets, limb length discrepancy, component size, femoral head offset, implant type, femoral stem alloy and taper design. Results. The occurrence of ALTR was associated with increased femoral head offset (non-ALTR vs. ALTR, 0.5 ± 3.7 vs. 4.1 ± 3.6, p = 0.008), increased radiographic femoral stem offset (35.9 ± 7.4 mm vs 40.7 ± 7.1mm, p = 0.018), and the use of TMZF alloy stems (p = 0.051). The presence of ALTR was significantly associated with higher cobalt (9.1 µg/L vs. 0.4µg/L, p=0.001) and chromium (2.6µg/L vs. 0.4µg/L). A significant correlation was identified between the serum cobalt level and the femoral stem offset (R=0.375, p=0.009). Conclusions. Although the occurrence of head-neck taper corrosion in MoP THA is likely to be an interplay between implant and patient factors, the results of this study identified increased femoral head and stem offset and the use of TMZF alloy stems as risk factors associated with clinically relevant ALTR due to head-neck taper corrosion in MoP THA patients. The study provides evidenced-based information in risk stratification of symptomatic MoP THA patients for head-neck taper corrosion. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 23 - 23
1 Nov 2015
Jonas S Middleton R
Full Access

Introduction. Incidence of adverse soft tissue reaction following metal on metal hip has a reported incidence of up to 48%. The current imaging modality of choice is metal artefact reduction sequence (MARS) MRI. Consensus is that large, symptomatic pseudotumours should be treated surgically, changing the bearing surfaces to other materials. There is debate as to how asymptomatic pseudotumours should be monitored and managed. Patients/Materials & Methods. From our unit's database, 22 patients (7 female, 15 male) were identified with metal on metal hip replacements that had a ‘pseudotumour’ detected on MARS MRI but remained assymptomatic (mean 68 months post op). All underwent serial imaging and clinical follow up (mean interval 14.5 months). Results. At initial imaging 16 pseudotumours were Norwich classification C1 (mild), 5 were C2 (moderate) and 1 was C3 (severe). At follow up no pseudotumours had increased in size or increased in severity with regards to Norwich classification. Four initially classified as C1 had changed to ‘A’. Oxford Hip score did not change significantly in this interval. Discussion. Previously published studies have been either small or ‘snap shot’ and have not provided conclusive guidance as to how these patients should be managed. Our study shows that this patient group can be treated expectantly and avoid revision surgery. Conclusion. Pseudotumour Norwich grade, size and characteristics remain unchanged on MARS MRI at a period of over one year in our cohort. Our study suggests serial imaging is not necessary unless patients develop symptoms


Bone & Joint Open
Vol. 4, Issue 3 | Pages 182 - 187
14 Mar 2023
Sheridan GA Hanlon M Welch-Phillips A Spratt K Hagan R O'Byrne JM Kenny PJ Kurmis AP Masri BA Garbuz DS Hurson CJ

Aims

Hip resurfacing remains a potentially valuable surgical procedure for appropriately-selected patients with optimised implant choices. However, concern regarding high early failure rates continues to undermine confidence in use. A large contributor to failure is adverse local tissue reactions around metal-on-metal (MoM) bearing surfaces. Such phenomena have been well-explored around MoM total hip arthroplasties, but comparable data in equivalent hip resurfacing procedures is lacking. In order to define genetic predisposition, we performed a case-control study investigating the role of human leucocyte antigen (HLA) genotype in the development of pseudotumours around MoM hip resurfacings.

Methods

A matched case-control study was performed using the prospectively-collected database at the host institution. In all, 16 MoM hip resurfacing 'cases' were identified as having symptomatic periprosthetic pseudotumours on preoperative metal artefact reduction sequence (MARS) MRI, and were subsequently histologically confirmed as high-grade aseptic lymphocyte-dominated vasculitis-associated lesions (ALVALs) at revision surgery. ‘Controls’ were matched by implant type in the absence of evidence of pseudotumour. Blood samples from all cases and controls were collected prospectively for high resolution genetic a nalysis targeting 11 separate HLA loci. Statistical significance was set at 0.10 a priori to determine the association between HLA genotype and pseudotumour formation, given the small sample size.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 60 - 60
1 Jan 2018
Lachiewicz P O'Dell J
Full Access

Trunnion corrosion in metal-on-polyethylene THA is poorly understood, with multifactorial etiology, and the patients present with “hip pain”. We analysed the presenting symptoms and signs, intraoperative findings and the early results and complications of operative treatment. One surgeon treated 9 patients (6 male, 3 female), mean age 74 years, with the onset of symptoms at a mean of 7 years (range 3–18) after index surgery. The taper size was 12/14 in seven, 14/16 in one, and 6 degree in one hip. The preoperative mean cobalt level was 7.1 ppb (range, 2.2–12.8) and mean chromium level was 2.2 ppb (range, 0.5–5.2). MARS MRI showed fluid collection and pseudotumor in 5, fluid collection only in two, and synovitis/debris in one hip. In one patient, there was no preoperative MRI. There were a myriad of clinical presentations: thigh rash alone in one; diffuse leg pain and hip rash in one; acute pseudo-sepsis in one; iliopsoas tendinitis and diffuse rash in one; trochanteric bursitis in one; groin pain only in one; thigh-buttock pain in two; and diffuse hip pain and limp in one patient. Intraoperatively, 6 patients had liner and ceramic (or oxidized zirconium) head exchange only. Three patients had concurrent acetabular revision: one for broken locking mechanism; one because liner was unavailable, and one had acetabular loosening. The postoperative metal levels decreased in all patients: mean cobalt 0.5 ppb (range, 0–1.8) and mean chromium 0.9 ppb (range, 0–2.6). Seven patients had good pain relief and no complications. There were two major complications requiring reoperation: acute infection at 6 weeks and patient required 2-stage reimplantation; and second patient had recurrent dislocation and was revised to a dual mobility component. Trunnion corrosion in metal-on-polyethylene THA has several clinical presentations, including local skin rash, iliopsoas tendinitis, and other limb dysfunction. There should be a high index of suspicion and serum cobalt/chromium levels are recommended for diagnosis. The patients should be counseled about possible postoperative complications


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 43 - 43
1 Jun 2017
Kiran M Shivarathre D Peter V
Full Access

There has been a significant decline in the use of metal-on-metal (MoM) bearings due to concerns regarding adverse reaction to metal debris (ARMD). The Medicines and Healthcare products Regulatory Agency (MHRA) recommends annual follow-up for life with blood Cobalt (Co) and Chromium (Cr) ion level measurement in all MoM THRs with femoral head size greater than or equal to 36mm. We present the serial ten year serum Co and Cr levels in a cohort of large head MoM THRs and analyse the utility of measuring serum ions levels annually. All patients who underwent unilateral large head MoM THR between January 2004 and December 2006 were included in this prospective study. Annual serum Co and Cr measurements were measured. Clinical case notes and radiographs were reviewed for failure, revision surgery and the occurrence of ARMD. Mann Whitney test was used to analyse changes in serum Co and Cr levels. Receiver Operating Characteristic (ROC) curve was plotted based on their sensitivity and specificity to detect ARMD. 256 patients were included. There was a significant increase in serum ion values in the first two years. After 7 years, there was no significant change in Co values(p=0.78) and there was a decline in Cr value after 9 years(p<0.001). With 7 µg/l as the cut-off value, the sensitivity and specificity of Co was 82.1% and 65.5% and of Cr was 53.5% and 91.3%. Annual follow-up of patients with MoM THR based on the MHRA guideline to obtain serum metal ion levels can cost about £9 million/year. Our study noted poor discriminatory ability for both Co and Cr values in the ROC curve. There is poor correlation between serum metal ion levels and the occurrence of ARMD on MARS MRI. Based on our results we find limited utility in doing ion levels after 7 years in asymptomatic patients


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 852 - 858
1 Jul 2022
Grothe T Günther K Hartmann A Blum S Haselhoff R Goronzy J

Aims

Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors.

Methods

Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti12Mo6Zr2Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 22 - 22
1 Nov 2015
Eyre-Brook A Pearce A Lyle N Stranks G Briant-Evans T
Full Access

Introduction. The prevalence of adverse reactions to metal debris around metal-on-metal (MOM) hip replacements has been reported to range from 7 to 69%. Little has been published on MRI scans with conventional total hip bearing surfaces. This study aimed to establish the prevalence of soft tissue lesions associated with metal-on-polyethylene (MOP) and ceramic-on-ceramic (COC) bearings, compared to MOM prostheses. Patients/Materials & Methods. All Metal Artefact Reduction Sequence (MARS) MRI scans for MOM THRs performed at our unit from January 2009 to present were reviewed, identifying those with contralateral primary MOP or COC THRs included on the scan. These were compared to a previously analysed cohort of 281 MOM THRs. Scans were classified using the Modified Oxford Classification as ‘Normal’, ‘Trochanteric Fluid’, ‘Effusions’ or Adverse Reactions to Debris. Results. 72 MOP and 17 COC prostheses were identified. More abnormalities were seen with scans performed within 12 months of surgery; 7 of 11 having findings consistent with post-operative seromas. These 11 were therefore excluded from further analysis. A higher proportion of normal MRIs were seen in the conventional prostheses group (78% v 34%, p<0.001). Adverse reactions to debris were significantly more common in MOM prostheses (39% v 4%, p<0.001). Effusions were more common with MOM bearings (13% v 4%, p=0.028). There was no difference in the rates of trochanteric fluid (both groups 14%). Discussion. A much higher rate of clinically significant fluid collections were seen with MOM prostheses as a result of increased toxicity of metal debris versus polyethylene or ceramic. There was little difference between MOP and COC scans. Trochanteric fluid collections are more likely to represent bursitis than any problem with the bearing surface. Conclusion. These results provide a useful baseline for comparison of MOM MARS MRI scans, adding to our understanding of the unique failure patterns of MOM prostheses


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 555 - 564
1 Jun 2024
Leal J Holland CT Cochrane NH Seyler TM Jiranek WA Wellman SS Bolognesi MP Ryan SP

Aims

This study aims to assess the relationship between history of pseudotumour formation secondary to metal-on-metal (MoM) implants and periprosthetic joint infection (PJI) rate, as well as establish ESR and CRP thresholds that are suggestive of infection in these patients. We hypothesized that patients with a pseudotumour were at increased risk of infection.

Methods

A total of 1,171 total hip arthroplasty (THA) patients with MoM articulations from August 2000 to March 2014 were retrospectively identified. Of those, 328 patients underwent metal artefact reduction sequence MRI and had minimum two years’ clinical follow-up, and met our inclusion criteria. Data collected included demographic details, surgical indication, laterality, implants used, history of pseudotumour, and their corresponding preoperative ESR (mm/hr) and CRP (mg/dl) levels. Multivariate logistic regression modelling was used to evaluate PJI and history of pseudotumour, and receiver operating characteristic curves were created to assess the diagnostic capabilities of ESR and CRP to determine the presence of infection in patients undergoing revision surgery.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 1 - 1
1 Oct 2020
Clohisy J Haddad FS
Full Access

The unparalleled events of the year 2020 continue to evolve and challenge the worldwide community on a daily basis. The COVID-19 pandemic has had a major impact on all aspects of our lives, and has caused major morbidity and mortality around the globe. The impact of COVID-19 on the practice of orthopedic surgery has been substantial with practice shutdowns, elective surgery restrictions, heightened utilization of telemedicine platforms and implementation of precautionary measures for in-person clinic visits. During this transition period the scholarly and educational pursuits of academic surgeons have been de-emphasized as the more immediate demands of clinical practice survivorship have been the priority. This unavoidable focus on clinical practice has heightened the importance of orthopedic subspecialty societies in maintaining an appropriate level of attention on research and educational activities. Under the outstanding presidential leadership of Robert Barrack, MD, The Hip Society adapted to the profound challenges of 2020, and maintained strong leadership in the realms of education and research. The recent 2020 summer meeting of the Hip Society was a testimonial to the resilience and dedication of the Society members to ongoing innovation in research and education. Due to travel and social distancing restrictions the 2020 summer meeting was transitioned from an in-person to a virtual meeting format. Dr Barrack and Program Chair Dr John Clohisy assisted with oversight of the meeting, while Olga Foley and Cynthia Garcia ensured the success of the meeting with remarkable planning and organization. These collaborative efforts resulted in an organized, well-attended, high level scientific meeting with engaging discussion and a remarkable virtual conference environment. The Bone & Joint Journal is very pleased to partner with The Hip Society to publish the proceedings of this very unique virtual meeting. The Hip Society is based in the United States and membership is granted to select individuals for leadership accomplishments in education and research related to hip disease. The Society is focused on the mission of advancing the knowledge and treatment of hip disorders to improve the lives of patients. The vision of the Hip Society is to lead in the discovery and dissemination of knowledge related to disorders of the hip. The annual closed meeting is one of the most important events of the society as this gathering highlights timely, controversial and novel research contributions from the membership. The top research papers from The Hip Society meeting will be published and made available to the wider orthopedic community in The Bone & Joint Journal. This partnership with The Bone & Joint Journal enhances the mission and vision of The Hip Society by international dissemination of the meeting proceedings. Given the far-reaching circulation of The Bone & Joint Journal the highest quality work is available to an expanding body of surgeons, associated healthcare providers and patients. Ultimately, this facilitates the overarching Hip Society goal of improving the lives of our patients. The 2020 virtual Hip Society meeting was characterized by outstanding member attendance, high quality paper presentations and robust discussion sessions. The meeting was held over two days and encompassed 58 open paper presentations divided into ten sessions with moderated discussions after each session. All papers will be presented in this issue in abstract form, while selected full papers passing our rigorous peer review process will be available online and in The Bone & Joint Journal in a dedicated supplement in 2021. The first session of the meeting focused on issues related to complex primary THA and osteonecrosis of the femoral head. Dr Gross presented on the conversion of hip fusion to THA in 28 patents at a mean 7 years. He reported a high clinical success rate, yet complications of heterotopic ossification and neurologic injury were relatively common. Consideration of heterotopic ossification prophylaxis and the selective use of a constrained liner were recommended. Dr Pagnano summarized the use of various contemporary porous acetabular components in 38 hips in the setting of prior pelvic radiation. The mean follow-up was 5 years and 10 year survivorship was 100% with all implants radiographically fixed. Dr Bolognesi's study demonstrated that THA in solid organ transplant patients is associated with higher risk for facility placement, transfusions and readmissions. This patient population also has increased mortality risk (4.3% risk at 1 year) especially lung transplant patients. The second group of papers focused on femoral head osteonecrosis. Dr Iorio presented single center data demonstrating that CT scan was a useful adjunct for diagnosis in the staging work-up for cancer, yet was not useful for ARCO staging and treatment decision-making. On the basic science side, Dr Goodman utilized a rabbit model of steroid-induced femoral head osteonecrosis to determine that immunomodulation with IL-4 has the potential to improve bone healing after core decompression. The session was concluded by Dr Nelson's study of ceramic-on-ceramic THA in 108 osteonecrosis patients. The median 12 year results were outstanding with marked increases in PROs, maintenance of high activity levels, and a 3.7% revision rate. In the second session attention was directed to THA instability and spinopelvic mobility. Dr Sierra presented a machine learning algorithm for THA dislocation risk. Two modifiable variables (anterior/lateral approach, elevated liner) were most influential in minimizing dislocation risk. Dr Taunton's study demonstrated a deep learning artificial intelligence model derived from postoperative radiographs to predict THA dislocation risk. High sensitivity and negative predictive value suggest that this model may be helpful in assessing postoperative dislocation risk. In reviewing a large single-center, multiple surgeon cohort of 2,831 DAA procedures, Dr Moskal noted a very low dislocation rate (0.45%) at minimum 2 years. Importantly, spinopelvic pathology or prior spinal instrumentation was not associated with an increased dislocation risk (0.30%). Dr Huo and colleagues analyzed pelvic tilt during functional gait in patients with acetabular dysplasia. They detected variable pelvic tilt on different surfaces with the data suggesting that patients with more anterior pelvic tilt while standing tend to have greater compensatory posterior pelvic tilt during gait. Dr Lamontagne reported on the sagittal and axial spinomobility in patients with hip OA, and highlighted reductions in pelvic tilt, pelvic-femoral-angle, lumbar lordosis and seated maximal trunk rotation when compared to controls. Dr Dennis showed that differences in spinopelvic mobility may explain the variable accuracy of acetabular version measurements on the cross-table lateral radiographs. Dr Gwo-Chin presented on a comprehensive functional analysis of 1,592 patients undergoing THA and observed that spinopelvic abnormalities are not infrequent (14%) in THA patients. Consistent with these findings Dr Murphy and collaborators identified a low prevalence of previous spinal instrumentation (1.5%), yet a high prevalence of spine stiffness (27.6%) in 149 patients undergoing THA. Session three highlighted various aspects of treating hip disease in young patients. Dr Peters investigated the need for subsequent hip arthroscopy in 272 patients treated with an isolated PAO. Only 4.8% of these patients required subsequent arthroscopy calling into question the routine use of combined arthroscopy and PAO. Three papers addressed questions related to THA in young patients. Dr Berend's study of 2532 hips demonstrated that high activity level was not associated with an increased risk of midterm aseptic or all cause failure. Dr Nunley presented on 43 young patients with an average age of 52 years treated with a cementless stem and modular dual mobility articulation. Stress shielding was minimal and no concerning metal ion release detected. Dr Garvin summarized minimum 15 year data of THA with highly cross-linked polyethylene in patient less than 50 years. These hips performed exceptionally well with no mechanical loosening or radiographic osteolysis. Dr Engh examined 10 year results of the Birmingham Hip Resurfacing implant and reported a 92.9 % overall survivorship, with males less than 55 years achieving a 98.3% survivorship. The session was concluded by long-term data on the Conserve Plus hip resurfacing arthroplasty. Dr Amstutz presented an impressive dataset depicting an 83.1% 20 year survivorship for this early resurfacing cohort. Direct anterior approach total hip arthroplasty was the focus of session four. Dr Meneghini reported on the anesthesia and surgical times of direct anterior and posterior approaches from a large healthcare system database. These data suggested longer OR and surgical times for the DAA both in the inpatient and ASC environments. Dr Clohisy introduced the technique and early outcomes of lateral decubitus position DAA. In a learning curve experience of 257 hips. 96% of acetabular components were in the Lewinneck safe zone, the aseptic revision rate was 0.9% and there were no dislocations. Dr Beaule analyzed femoral stem cement mantle with the DAA and posterior approaches by comparing two matched cohorts. Stem alignment and cement mantle quality were equivalent with both approaches. Similarly, Dr Emerson demonstrated technical feasibility and fewer cemented femoral stem failures when compared to cementless stems in a series of 360 DAAs THAs. The final paper of the session presented by Dr Hamilton examined the impact of surgical approach on dislocation after isolated head and liner exchange. Neither the posterior nor the anterior approach was superior in reducing the dislocation rate for these high dislocation risk procedures. The fifth session explored contemporary topics related to anesthesia and pain management. Dr Byrd opened the session with a comparative study evaluating general versus spinal anesthesia for hip arthroscopy. This preliminary study was provoked by the desire to minimize aerosolized exposure early in the COVID-19 pandemic by transitioning to spinal anesthesia. Both anesthetic methods were effective. Dr Austin presented a randomized, double-blind controlled trial comparing spinal anesthetic with mepivacaine, hyperbaric bupivacaine and isobaric bupivacaine. Mepivacaine patients ambulated earlier and were more likely to be discharged the same day. Dr Mont provided a very timely study on the effects of “cannabis use disorder” and THA outcomes. This administrative database study of 44,154 patients revealed this disorder to be associated with longer hospital stays, increased complications rates and higher costs. Dr Bedair investigated whether a highly porous acetabular component submerged in an analgesic solution could enhance perioperative pain management. Interestingly, this novel strategy was associated with a reduction of postoperative pain scores and opioid consumption in 100 experimental patients compared to 100 controls. The concluding paper of the session by Dr Della Valle examined whether decreased discharge opioids led to increased postoperative opioid refills. A large single-center study of 19,428 patients detected a slight increase (5%) in opioid refills but a reduction in total refill morphine milligram equivalents. The final, sixth session of day one considered various challenging aspects of revision hip arthroplasty. Dr Nam started the session with review of preliminary results from a randomized control trial comparing closed incision negative-pressure therapy with a silver-impregnated dressing for wound management in 113 hips undergoing revision arthroplasty. Unlike previous reports, the negative pressure therapy was associated with a higher reoperation rate for wound-related complications. Dr Bostrom highlighted the potential clinical impact of basic biological interventions by establishing the presence of Neutrophil Extracellular Traps (NETS) in fibrotic tissue from human aseptic loosening specimens and in a murine model of unstable tibial implantation. NET inhibition in the murine model prevented the expected tibial implant osseointegration failure. Dr Lombardi presented early 3.3 year clinical results of a highly porous Ti6al4v acetabular component in complex primary and revision arthroplasty. Survivorship for aseptic loosening was 96.6 % and 95.3% for the primary and revision cases, respectively. Dr Schwarzkopf and colleagues explored the impact of time to revision arthroplasty on clinical outcomes. Analysis of 188 revision cases revealed early revisions (less than 2 years from primary) were associated with worse outcomes, longer hospitalizations and higher reoperation rates. Mid-term results for modular dual mobility implants in revision arthroplasty were reviewed by Dr Lachiewicz who reported on 126 hips at a mean 5.5 years. 11% of hips dislocated and the 6 year survival was 91%. An outer head diameter of 48mm or greater was associated with a lower risk of dislocation. Dr Berry concluded the session by discussing the outcomes of treating the challenging problem of interprosthetic femur fractures. A single-center study of 77 cases treated over 32 years demonstrated a 79% success rate free of reoperation at 2 years with 95% of patients being ambulatory. The second day commenced with the seventh session evaluating recent strategies to improve short-term THA outcomes. Dr Bozic and colleagues investigated the association of quality measure public reporting with hip/knee replacement outcomes. Annual trend data from 2010–2011 and 2016–2017 indicate that hospital-level complication and readmission rates decease after the start of public reporting, yet it is difficult to prove a direct effect. Dr Slover reviewed his institutions experience with the Comprehensive Care for Joint Replacement (CJR) model and emphasized that lower CJR target prices make it increasingly difficult for programs to meet target price thresholds. Cost saving strategies including same day discharge and reduction of home health services may result in smaller losses of positive margins. Dr Barsoum reported on the influence of patient and procedure-related risk factors of length of stay after THA. Patient-related risk factors provided substantial predictive value yet procedure-related risk factors (hospital site and surgical approach) remain the main drivers of predicting length of stay. Dr Hozack reviewed an impressive, single surgeon cohort of 3,977 DAA THAs and analyzed adverse events and 90 day perioperative outcomes. Simultaneous bilateral DAA THA was comparable with unilateral or staged bilateral procedures in regards to complications, readmission rate and home discharge rate but with an increased risk of transfusion. To examine the risk of complications with outpatient joint arthroplasty, Dr Della Valle performed a single-surgeon matched cohort analysis comparing outpatient and inpatient hip and knee arthroplasties. Outpatient procedures were not associated with an increased risk of any postoperative complications and actually experienced fewer emergency department visits. The eighth session covered various contemporary challenges in hip arthroplasty care. Dr Griffin began the session with an analysis of the timing of complications associated with two-stage exchange procedures for periprosthetic joint infection (PJI). Of the 189 hips included, 41.6% had a complication and the mortality was 14.1% at 2.5 years, highlighting the morbidity of this treatment method. Dr Fehring provided data assessing the fate of two-stage reimplantation after failed debridement, antibiotics and implant retention (DAIR) for a prosthetic hip infection. This analysis of 114 hips yielded concerning results demonstrating a 42.9% treatment failure of patients treated with a previous DAIR compared to a 12.3% failure rate in patients treated with an initial 2-stage procedure. Dr Jacobs reviewed the analysis of 106 femoral heads with severe corrosion and identified a chemically dominated etching process termed “column damage” to be a detrimental damage mode within CoCr femoral heads that is directly linked to banding within its microstructure. These data indicate that implant alloy microstructure must be optimized to minimize the release of fretting-corrosion products. Simon Mears presented retrospective data from 184 THAs with a dual modular femoral stem. A subgroup of hips with a modular, cobalt chromium femoral neck had a pseudotumor visualized in 15% with only 55% of these having elevated CoCr levels. These findings may support the use of routine follow-up MARS MRI for modular CoCr femoral neck prostheses. The final two studies explored timely issues related to viral illness and hip surgery. Dr Browne analyzed three large administrative databases to elucidate whether patients are at increased risk for viral illnesses following total joint replacement. The incidence of postoperative influenza after total joint replacement was not increased compared to patients not undergoing total joint replacement surgery suggesting that arthroplasty procedures may not heighten the risk of viral illness. In the final paper of the session Dr Haddad presented important data regarding perioperative complications in coronavirus positive patients undergoing surgical treatment of femoral neck fractures. In this multicenter cohort study from the United Kingdom 82 coronavirus positive patients were shown to have longer hospital stays, more critical care unit admissions, higher risk of perioperative complications and an increased mortality compared to 340 coronavirus negative patients. The eighth session had two papers on alternative femoral stem designs and three presentations more focused on femoral fracture treatments. Dr Mihalko focused on the European and US experiences with the Metha femoral neck retaining stem. The US experience mirrored the encouraging results from Europe with a 94% all cause femoral survivorship and a 99.1% femoral aseptic loosening survivorship at 5 years. Dr Kraay summarized dual energy x-ray absorptiometry (DEXA) evaluation of 16 low modulus composite femoral components at long-term follow-up of a mean 22 years. The bone mineral density associated with the implant increased in Gruen zones 2–6 and showed limited decreases in zones 1 and 7. These data support the concept that a low modulus femoral stem may more effectively load the proximal femur. Dr Springer provided data from the American Joint Replacement Registry (AJRR) and by evaluating outcomes of exact matched cohorts of 17,138 patients treated with cementless or cemented femoral implants for femoral neck fractures. Cemented implants were associated with marked reduction in early revision and periprosthetic fractures. However, cemented fixation was associated with an increased mortality at 90 days and 1 year. Additional data from the AJRR was presented by Dr Huddleston who investigated the risk factors for revision surgery after arthroplasty in a cohort of 75,333 femoral neck fractures. THA when compared to hemiarthroplasty was associated with higher early and overall revision rates. Cementless femoral fixation and increased age were also associated with higher rates of any revision. Both of these studies from the AJRR suggest that further consideration should be given to femoral fixation preferences in the femoral neck fracture population. Dr Vail summarized his institution's experience with an interdisciplinary hip fracture protocol for patients undergoing arthroplasty for acute femoral neck fractures. His study compared 157 cases prior to protocol implementation with 114 patients treated after the protocol was established. The impact of the interdisciplinary protocol was impressive as evidenced by a reduced time to operative treatment, length of stay, complication rate and one-year mortality. All being achieved without an increase in readmissions or facility discharges. The final session of the meeting addressed innovations in perioperative care of THA patients. Dr Barrack started the session with an interesting study examining the feasibility and patient preferences regarding telemedicine. A cross-sectional telephone survey of 163 arthroplasty patients indicated that 88% of patients use the internet and 94% own a device capable of videoconferencing. Nevertheless, only 18% of patients preferred a video visit over an in-person clinic visit due to concerns of inferior care. Dr Barnes quantified preoperative optimization work in 100 arthroplasty patients by using EMR activity logs and determined the surgical team spends an average 75 minutes per case on preoperative work activities. Dr Duwelius reported the early outcomes of primary THA with a smartphone-based exercise and educational platform compared to standard of care controls. A randomized control trial design with 365 patients demonstrated similar outcomes and non-inferiority of the smartphone platform relative to complications, readmissions, emergency room/urgent care visits. The association of controlled substance use with THA outcomes was assessed by Dr Higuera Rueda. A quantitative assessment using the NarxCare score identified 300 and above as a score associated with adverse outcomes after THA. Dr Macaulay reviewed data from a large retrospective study of 1,825 THAs indicating that discontinuation of intermittent pneumatic compression devices does not increase the risk of venous thromboembolism in standard risk patients being treated with 81mg ASA BID as prophylaxis. Dr Antoniou presented the final paper of the meeting investigating potential changes in patient health status as an indication for surgery over time. Data from this large systematic review of the literature found patients undergoing THA at similar health status to the past with no influence form patient age, gender, year of enrollment or geographic region. As summarized above, the 2020 virtual Hip Society Summer Meeting was rich in scientific content, productive discussion and a collaborative spirit. This collective body of work will result in impactful scientific contributions and will serve as a foundation for future innovation and advancements in the treatment of hip disease


Bone & Joint Open
Vol. 2, Issue 5 | Pages 278 - 292
3 May 2021
Miyamoto S Iida S Suzuki C Nakatani T Kawarai Y Nakamura J Orita S Ohtori S

Aims

The main aims were to identify risk factors predictive of a radiolucent line (RLL) around the acetabular component with an interface bioactive bone cement (IBBC) technique in the first year after THA, and evaluate whether these risk factors influence the development of RLLs at five and ten years after THA.

Methods

A retrospective review was undertaken of 980 primary cemented THAs in 876 patients using cemented acetabular components with the IBBC technique. The outcome variable was any RLLs that could be observed around the acetabular component at the first year after THA. Univariate analyses with univariate logistic regression and multivariate analyses with exact logistic regression were performed to identify risk factors for any RLLs based on radiological classification of hip osteoarthritis.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1018 - 1024
1 Aug 2018
Ando W Yasui H Yamamoto K Oinuma K Tokunaga H Inaba Y Kobayashi N Aihara M Nakanishi R Ohzono K

Aims

The purpose of this study was to compare two different types of metal-on-metal (MoM) bearing for total hip arthroplasty (THA): one with a large femoral head (38 mm to 52 mm) and the other with a conventional femoral head (28 mm or 32 mm). We compared clinical outcome, blood metal ion levels, and the incidence of pseudotumour in the two groups.

Patients and Methods

Between December 2009 and December 2011, 62 patients underwent MoM THA with a large femoral head (Magnum group) and 57 patients an MoM THA with a conventional femoral head (conventional group). Clinical outcome was assessed using the Harris Hip score, University of California, Los Angeles (UCLA) activity score and EuroQol-5D (EQ-5D). Blood metal ion levels were measured and MRI scans were analyzed at a minimum of five years postoperatively.


Bone & Joint Research
Vol. 5, Issue 9 | Pages 379 - 386
1 Sep 2016
Pahuta M Smolders JM van Susante JL Peck J Kim PR Beaule PE

Objectives

Alarm over the reported high failure rates for metal-on-metal (MoM) hip implants as well as their potential for locally aggressive Adverse Reactions to Metal Debris (ARMDs) has prompted government agencies, internationally, to recommend the monitoring of patients with MoM hip implants. Some have advised that a blood ion level >7 µg/L indicates potential for ARMDs. We report a systematic review and meta-analysis of the performance of metal ion testing for ARMDs.

Methods

We searched MEDLINE and EMBASE to identify articles from which it was possible to reconstruct a 2 × 2 table. Two readers independently reviewed all articles and extracted data using explicit criteria. We computed a summary receiver operating curve using a Bayesian random-effects hierarchical model.


Bone & Joint Research
Vol. 6, Issue 2 | Pages 113 - 122
1 Feb 2017
Scholes SC Hunt BJ Richardson VM Langton DJ Smith E Joyce TJ

Objectives

The high revision rates of the DePuy Articular Surface Replacement (ASR) and the DePuy ASR XL (the total hip arthroplasty (THA) version) have led to questions over the viability of metal-on-metal (MoM) hip joints. Some designs of MoM hip joint do, however, have reasonable mid-term performance when implanted in appropriate patients. Investigations into the reasons for implant failure are important to offer help with the choice of implants and direction for future implant designs. One way to assess the performance of explanted hip prostheses is to measure the wear (in terms of material loss) on the joint surfaces.

Methods

In this study, a coordinate measuring machine (CMM) was used to measure the wear on five failed cementless Biomet Magnum/ReCap/ Taperloc large head MoM THAs, along with one Biomet ReCap resurfacing joint. Surface roughness measurements were also taken. The reason for revision of these implants was pain and/or adverse reaction to metal debris (ARMD) and/or elevated blood metal ion levels.


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 901 - 909
1 Jul 2016
Amstutz HC Le Duff MJ

Aims

Hip resurfacing arthroplasty (HRA) is an alternative to conventional total hip arthroplasty for patients with osteonecrosis (ON) of the femoral head. Our aim was to report the long-term outcome of HRA, which is not currently known.

Patients and Methods

Long-term survivorship, clinical scores and radiographic results for 82 patients (99 hips) treated with HRA for ON over a period of 18 years were reviewed retrospectively. The mean age of the 67 men and 15 women at the time of surgery was 40.8 years (14 to 64). Patients were resurfaced regardless of the size of the osteonecrotic lesion.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 40 - 48
1 Jan 2016
Matharu GS Mansour R Dada O Ostlere S Pandit HG Murray DW

Aims

The aims of this study were to compare the diagnostic test characteristics of ultrasound alone, metal artefact reduction sequence MRI (MARS-MRI) alone, and ultrasound combined with MARS-MRI for identifying intra-operative pseudotumours in metal-on-metal hip resurfacing (MoMHR) patients undergoing revision surgery.

Methods

This retrospective diagnostic accuracy study involved 39 patients (40 MoMHRs). The time between imaging modalities was a mean of 14.6 days (0 to 90), with imaging performed at a mean of 5.3 months (0.06 to 12) before revision. The prevalence of intra-operative pseudotumours was 82.5% (n = 33).


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1175 - 1182
1 Sep 2015
Bisseling P de Wit BWK Hol AM van Gorp MJ van Kampen A van Susante JLC

Patients from a randomised trial on resurfacing hip arthroplasty (RHA) (n = 36, 19 males; median age 57 years, 24 to 65) comparing a conventional 28 mm metal-on-metal total hip arthroplasty (MoM THA) (n = 28, 17 males; median age 59 years, 37 to 65) and a matched control group of asymptomatic patients with a 32 mm ceramic-on-polyethylene (CoP) THA (n = 33, 18 males; median age 63 years, 38 to 71) were cross-sectionally screened with metal artefact reducing sequence-MRI (MARS-MRI) for pseudotumour formation at a median of 55 months (23 to 72) post-operatively. MRIs were scored by consensus according to three different classification systems for pseudotumour formation.

Clinical scores were available for all patients and metal ion levels for MoM bearing patients.

Periprosthetic lesions with a median volume of 16 mL (1.5 to 35.9) were diagnosed in six patients in the RHA group (17%), one in the MoM THA group (4%) and six in the CoP group (18%). The classification systems revealed no clear differences between the groups. Solid lesions (n = 3) were exclusively encountered in the RHA group. Two patients in the RHA group and one in the MoM THA group underwent a revision for pseudotumour formation. There was no statistically significant relationship between clinical scoring, metal ion levels and periprosthetic lesions in any of the groups.

Periprosthetic fluid collections are seen on MARS-MRI after conventional CoP THA and RHA and may reflect a soft-tissue collection or effusion.

Currently available MRI classification systems seem to score these collections as pseudotumours, causing an-overestimatation of the incidence of pseudotumours.

Cite this article: Bone Joint J 2015;97-B:1175–82.


The Bone & Joint Journal
Vol. 96-B, Issue 12 | Pages 1594 - 1599
1 Dec 2014
Hwang KT Kim YH Kim YS Ryu JA

We investigated the incidence of soft-tissue lesions after small head metal-on-metal total hip replacement (MoM THR). Between December 1993 and May 1999, 149 patients (195 hips) underwent primary cementless MoM THR.

During the follow-up period, three patients (five THRs) died and eight patients (14 THRs) were lost to follow-up. We requested that all patients undergo CT evaluation. After exclusion of five patients (six THRs) who had undergone a revision procedure, and 22 (28 THRs) who were unwilling to take part in this study, 111 patients (142 THRs) were evaluated. There were 63 men (88 THRs) and 48 women (54 THRs) with a mean age of 45.7 years (37 to 56) at the time of surgery. The mean follow-up was 15.4 years (13 to 19). A soft-tissue lesion was defined as an abnormal peri-prosthetic collection of fluid, solid lesion or asymmetrical soft-tissue mass.

At final follow-up, soft-tissue lesions were found in relation to 28 THRs (19.7%), including 25 solid and three cystic lesions. They were found in 20 men and eight women; 26 lesions were asymptomatic and two were symptomatic. The mean maximal diameter of the soft-tissue lesion was 42.3 mm (17 to 135). The relatively high rate of soft-tissue lesions observed with small head MoM THR remains a concern.

Cite this article: Bone Joint J 2014;96-B:1594–9.