Bone & Joint Research
Vol. 5, Issue 6 | Pages 253 - 262
1 Jun 2016
Liu H Li W Liu YS Zhou YS

Objectives. This study aims to evaluate if micro-CT can work as a method for the 3D assessment and analysis of cancellous bone by comparing micro-CT with undecalcified histological sections in OVX rats. Methods. The mandible and tibia of sham, ovariectomised (OVX) and zoledronate-injected ovariectomised (OVX-ZOL) rats were assessed morphometrically. Specimens were scanned by micro-CT. Undecalcified histological sections were manufactured from the specimen scanned by micro-CT and stained with haematoxylin and eosin. Bivariate linear regressions and one-way analysis of variance were undertaken for statistics using SPSS 16.0.1 software. Results. There were highly significant correlations between undecalcified histological sections and micro-CT for all parameters (bone volume density (BV/TV), bone surface density (BS/BV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular separation (Tb.Sp))in the mandible and tibia. Bone histomorphometric parameters analysed by both methods exhibited significant differences among sham, OVX, and OVX-ZOL groups. There were significant correlations between mandible and tibia in BV/TV, BS/BV, and Tb.Sp. Conclusions. Micro-CT is a complementary tool to histological sections in basic research that could improve our understanding of bone histomorphometry. The mandible can be used as an effective site to assess bone morphometry of OVX or metabolic bone disease rat models. Cite this article: H. Liu, W. Li, Y. S. Liu, Y. S. Zhou. Bone micro-architectural analysis of mandible and tibia in ovariectomised rats: A quantitative structural comparison between undecalcified histological sections and micro-CT. Bone Joint Res 2016;5:253–262


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 51 - 51
1 Jan 2017
Ramos A Mesnard M
Full Access

The Temporomandibular joint (TMJ) is a complex and important joint for daily activities, and the alloplastic implant is recommended as the best solution, after repeated surgeries, failed autogenous grafts, highly inflammatory metabolic arthritis, fibrous or bony ankyloses. Some complications in total TMJ replacement are associated with implant design, screw fixation failure, implant displacement, fibrous tissue formation, (Speculand, et al. 2000). Some numeric studies evaluate the number of screws needed to guarantee the good fixation and suggest a minimum of three (Ramos et al. 2015), but is a controversy conclusion. The Biomet Microfixation TMJ stock prosthesis, Jacksonville, FL, USA is one of the three or four in the market. Clinical studies published by this device between 2005 and 2015 indicate a success rate of around 84 to 91% with improvements in mouth opening, a decrease in pain score and improved quality of life. The present study analyses experimentally the load transfer of this device. The intact, clean cadaveric ramus was instrumented with four rosettes model (KFG-1-120-D17-11 L3M2S, by Kywoa Electronic Instruments Co™, Japan), one in lateral region, two in lateral region and one in lingual face. The condyle was loaded with the temporal reaction; the load was applied constant velocity of 1mm/min in three continuum phases and with three stops at 100N, 200N and 300N. Next, the Biomet microfixation implant was fixed to the same cadaveric mandibular ramus after resection. The implant was 50mm in length. It was fixed with five 6AL/4V Titanium self-tapping screws with 2.7mm diameter were long enough to establish a bi-cortical support. The screws were screwed into the bone with a torque-screwdriver a constant torque of 0.2Nm. The same rosettes were analyzed before and after implantation and the mandible displacement two. The experimental results for the mandibular ramus present a linear behavior up to 300N load in condyle, with the Biomet implant influencing strain distribution; the maximum influence was near the implant (rosette #4) is around 59%. The average vertical displacement of the mandibular ramus (300N) was measured by machine: 1.18 (±0.02) mm for the intact mandibular ramus and 1.21 (±0.02) mm for the implanted one, which represents a 2.8% differences between the experimental models and reduce of stiffness. The maximum principal strain deformation was observed in the rosette #3 with 1360µε more 20% than the intact mandible for 300N of reaction. The experimental results show that the Biomet TMJ mandibular ramus implant changes the load transfer in the ramus, compared to the intact, with its strain shielding effect. The results indicate the minimum number of screws is three to guarantee a good load transfer but the surface preparation of condyle presents an important factor


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 55 - 55
1 Apr 2017
Singh S Parviaine I Hyvärinen M Dekker H Bruggenkate CT Mikkonen J Schulten E Bravenboer N Koistinen A Kullaa A
Full Access

Background. Radiotherapy has contributed with a significant and impressive stride to the survival rates of oral cancer patients. However, quality and alterations in the biochemical composition of bones used for dental implantation after radiotherapy in cancer patients is always a critical and debatable factor. The aim of this study was to determine compositional alterations in human mandible bone after irradiation using Raman microspectroscopy. Methods. A total of 36 bone biopsies (21-control, 4-cancer and 11-irradiated) obtained from 36 patients during implant surgery were used. Raman measurements were carried out using a Bruker Senterra LX200 dispersive Raman spectrometer. Data acquisition points were determined under pathological supervision. Three measurements from different locations were conducted with a spot size of 10 microns. Spectra were acquired for 60s and averaged over 5-accumulations. Both mineral and matrix constituents were analysed by computing area associated with of phosphate (958 cm-1), carbonate (1070 cm-1), collagen (amide III) and matrix (amide I) bands using in-house MATLAB-based software. Unpaired student ‘t’ test was employed to measure level of significance. Results. Absolute mineral contents (phosphate and carbonate) were higher in cancer specimens


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 10 - 10
14 Nov 2024
Zderic I Kraus M Rossenberg LV Puls L Pastor T Gueorguiev B Richards G Pape HC Pastor T
Full Access

Introduction. The main postoperative complications in fixation of ulna shaft fractures are non-union and implant irritation using currently recommended 3.5-mm locking compression plates. An alternative approach using a combination of two smaller plates in orthogonal configuration has been proposed. The aim of this study was to compare the biomechanical properties of a single 3.5-mm locking compression plate versus double plating using one 2.5-mm and one 2.0-mm mandible plate in a human ulna shaft fracture model. Method. Eight pairs human ulnar specimens with a standardized 10-mm fracture gap were pairwise assigned for instrumentation with either a single 3.5-mm plate placed posteriorly, or for double plating using a 2.5-mm and a 2.0-mm mandible plate placed posteriorly under the flexor muscles and laterally under the extensor muscles. All constructs were initially non-destructively biomechanically tested in axial compression, torsion, and bending, which was followed by cyclic torsional loading to failure. Interfragmentary movements were monitored by means of optical motion tracking. Result. There were no significant differences between the two plating techniques for axial stiffness (p=0.335), torsional stiffness in supination (p=0.462), torsional stiffness in pronation (p=0.307), medio-lateral bending stiffness (p=0.522), and antero-posterior bending stiffness (p=0.143). During cyclic torsional loading over the first 3000 cycles, there were no significant differences between the two plating techniques for shear displacement across the fracture gap, p=0.324. The numbers of cycles until clinically relevant failure of 5° angular deformation were 1366±685 for double plating and 2024±958 for single plating, which was statistically non-significantly different, p>0.05. The constructs treated with both plating techniques failed due to bone breakage at the most distal screw. Conclusion. From a biomechanical perspective double plating of ulna shaft fractures using a 2.5-mm and a 2.0-mm locking mandible plate demonstrated equivalent fixation strength as conventional plating using a single 3.5-mm locking compression plate


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 95 - 95
2 Jan 2024
Gjerde C
Full Access

The aim of the ongoing projects was to demonstrate the efficacy of autologous bone marrow derived stem cells (MSC) combined with biomaterial to induced new bone formation in a randomized multicenter controlled clinical trial. Patients with a need for bone reconstruction of residual edentulous ridges in both the mandible and maxilla due to bone defects with a vertical loss of alveolar bone volume and/or knife edge ridges (≤ than 4,5 mm) unable to provide adequate primary stabilization for dental implants were included in the clinical study. Autologous bone marrow MSC were expanded, loaded on BCP and used to augment the alveolar ridges. After five months bone biopsies were harvested at the implant position site and implants were installed in the regenerated bone. The implants were loaded after 8–12 weeks. Safety, efficacy, quality of life and success/survival were assessed. Five clinical centers, 4 different countries participated. Bone grafts harvested from the ramus of the mandibles were used as control in the projects


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 12 - 12
14 Nov 2024
Vautrin A Thierrin R Wili P Voumard B Rauber C Klingler S Chapuis V Varga P Zysset P
Full Access

Introduction. Achieving an appropriate primary stability after implantation is a prerequisite for the long-term viability of a dental implant. Virtual testing of the bone-implant construct can be performed with finite element (FE) simulation to predict primary stability prior to implantation. In order to be translated to clinical practice, such FE modeling must be based on clinically available imaging methods. The aim of this study was to validate an FE model of dental implant primary stability using cone beam computed tomography (CBCT) with ex vivo mechanical testing. Method. Three cadaveric mandibles (male donors, 87-97 years old) were scanned by CBCT. Twenty-three bone samples were extracted from the bones and conventional dental implants (Ø4.0mm, 9.5mm length) were inserted in each. The implanted specimens were tested under quasi-static bending-compression load (cf. ISO 14801). Sample-specific homogenized FE (hFE) models were created from the CBCT images and meshed with hexahedral elements. A non-linear constitutive model with element-wise density-based material properties was used to simulate bone and the implant was considered rigid. The experimental loading conditions were replicated in the FE model and the ultimate force was evaluated. Result. The experimental ultimate force ranged between 67 N and 789 N. The simulated ultimate force correlated better with the experimental ultimate force (R. 2. =0.71) than the peri-implant bone density (R. 2. =0.30). Conclusion. The developed hFE model was demonstrated to provide stronger prediction of primary stability than peri-implant bone density. Therefore, hFE Simulations based on this clinically available low-radiation imaging modality, is a promising technology that could be used in future as a surgery planning tool to assist the clinician in evaluating the load-bearing capacity of an implantation site. Acknowledgements. Funding: EU's Horizon 2020 grant No: 953128 (I-SMarD). Dental implants: THOMMEN Medical AG


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 107 - 107
2 Jan 2024
Pastor T Zderic I Berk T Souleiman F Vögelin E Beeres F Gueorguiev B Pastor T
Full Access

Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and optimized plate-to-bone fit design. On the other hand, mini-fragment plates used in dual plating mode have demonstrated promising clinical results. However, these two bone-implant constructs have not been investigated biomechanically in a human cadaveric model. Therefore, the aim of the current study was to compare the biomechanical competence of single superior plating using the new generation plate versus dual plating with low-profile mini-fragment plates. Sixteen paired human cadaveric clavicles were assigned pairwise to two groups for instrumentation with either a 2.7 mm Variable Angle Locking Compression Plate placed superiorly (Group 1), or with one 2.5 mm anterior plate combined with one 2.0 mm superior matrix mandible plate (Group 2). An unstable clavicle shaft fracture AO/OTA15.2C was simulated by means of a 5 mm osteotomy gap. All specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis and monitored via motion tracking. Initial stiffness was significantly higher in Group 2 (9.28±4.40 N/mm) compared to Group 1 (3.68±1.08 N/mm), p=0.003. The amplitudes of interfragmentary motions in terms of craniocaudal and shear displacement, fracture gap opening and torsion were significantly bigger over the course of 12500 cycles in Group 1 compared to Group 2; p≤0.038. Cycles to 2 mm shear displacement were significantly lower in Group 1 (22792±4346) compared to Group 2 (27437±1877), p=0.047. From a biomechanical perspective, low-profile 2.5/2.0 dual plates demonstrated significantly higher initial stiffness, less interfragmentary movements, and higher resistance to failure compared to 2.7 single superior variable-angle locking plates and can therefore be considered as a useful alternative for diaphyseal clavicle fracture fixation especially in unstable fracture configurations


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 35 - 35
11 Apr 2023
Pastor T Knobe M Ciric D Zderic I van de Wall B Rompen I Visscher L Link B Babst R Richards G Gueorguiev B Beeres F
Full Access

Implant removal after clavicle plating is common. Low-profile dual mini-fragment plate constructs are considered safe for fixation of diaphyseal clavicle fractures. The aim of this study was to investigate: (1) the biomechanical competence of different dual plate designs from stiffness and cycles to failure, and (2) to compare them against 3.5mm single superoanterior plating. Twelve artificial clavicles were assigned to 2 groups and instrumented with titanium matrix mandible plates as follows: group 1 (G1) (2.5mm anterior+2.0mm superior) and group 2 (G2) (2.0mm anterior+2.0mm superior). An unstable clavicle shaft fracture (AO/OTA15.2C) was simulated. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with torsion around the shaft axis and compared to previous published data of 6 locked superoanterior plates tested under the same conditions (G3). Displacement (mm) after 5000 cycles was highest in G3 (10.7±0.8) followed by G2 (8.5±1.0) and G1 (7.5±1.0), respectively. Both outcomes were significantly higher in G3 as compared to both G1 and G2 (p≤0.027). Cycles to failure were highest in G3 (19536±3586) followed by G1 (15834±3492) and G2 (11104±3177), being significantly higher in G3 compared to G2 (p=0.004). Failure was breakage of one or two plates at the level of the osteotomy in all specimens. One G1 specimen demonstrated failure of the anterior plate. Both plates in other G1 specimens. Majority of G2 had fractures in both plates. No screw pullout or additional clavicle fractures were observed among specimens. Low-profile 2.0/2.0 dual plates demonstrated similar initial stiffness compared to 3.5mm single plates, however, had significantly lower failure endurance. Low-profile 2.5/2.0 dual plates showed significant higher initial stiffness and similar resistance to failure compared to 3.5mm single locked plates and can be considered as a useful alternative for diaphyseal clavicle fracture fixation. These results complement the promising results of several clinical studies


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 40 - 40
1 Jan 2017
Benassarou M Schouman T Pazart L Gindraux F Bertolus C Meyer C
Full Access

In the area of 3D printing, more and more maxillofacial surgery departments are equipped with 3D printers to build their own anatomical models or surgical guides. Prior to be printable, the patients' DICOM imaging data has to be converted to a 3D virtual model, a 3D mesh. The file format most commonly used is the STL (Standard Tesselation Language) file format. Many programs exist that are able to convert DICOM data to STL files. Commercial software, such as Surgicase CMF© are FDA- and CE-approved whereas free programs, available online do not have the approval. However, the latter are often used anyway because of financial reasons. In this article, we investigate whether 6 of these software solutions are equivalent or not. Thin slice CT imaging data of a patient's mandible (in DICOM file format) was converted to STL meshes with 6 different software solutions. One commercial program, Surgicase CMF©, was used to build the reference model. Then 5 free programs were used to create 5 models of the same mandible, specifying the same thresholding parameters: InVesalius 3.0, 3DimViewer 2.2.4, 3D Slicer, itk-Snap and Seg3D. All of these models were loaded in Netfabb Basic 6.4 to retrieve dimensional data, geometric information and the number of holes in each mesh. Finally, the models were then compared to the reference model using CloudCompare 2.6.2. All models created with free software differed from the reference model in the 3 dimensions. Mean length difference was −0.74 mm [−2.06; −0.32] (SD: 0.74), mean width difference −0.45 mm [−0.76; −0.25] (SD: 0.19) and mean height difference was 0.41 mm [0.14; 0.62] (SD: 0.18). Although the height was increased in all models, both the length and width were systematically decreased, resulting in an average decrease of volume of −7.1 cm. 3. [−7.45; −6.77] (SD: 0.32). The number of triangles used to create each mesh ranged from 20944 to 368244, resulting in a variation of the file size from 1023 Ko to 80462 Ko (0.16 to 12.70 times the file size of the reference model). Two of the free programs created meshes with errors, such as the presence of holes (non-watertight meshes) that could be repaired with Netfabb. Free programs able to convert volume imaging data to a printable virtual mesh do not provide equivalent results. Variations were noted in the three plane of space with a systematic difference between free programs and the commercial FDA-approved one. While the length and width were less than a millimeter different to the reference, the dimension that most varied was the length with a difference reaching −2.06 mm with itk-Snap. Geometric data also varied significantly, the number of triangles composing the meshes being much different than the reference, resulting in variable file sizes. This traduces the fact that algorithms used by the programs are not the same. In the era of 3D printing made directly accessible in surgical departments, great attention should be paid to the accuracy of the models created with free software


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 984 - 988
1 Jul 2007
Omi H Kusumi T Kijima H Toh S

We investigated the effect of locally administered bisphosphonate on distraction osteogenesis in a rabbit model and evaluated its systemic effect. An osteotomy on the right tibia followed by distraction for four weeks was performed on 47 immature rabbits. They were divided into seven equal groups, with each group receiving a different treatment regime. Saline and three types of dosage of alendronate (low, 0.75 μg/kg; mid, 7.5 μg/kg and high 75 μg/kg) were given by systemic injection in four groups, and saline and two dosages (low and mild) were delivered by local injection to the distraction gap in the remaining three groups. The injections were performed five times weekly during the period of distraction.

After nine weeks the animals were killed and image analysis and mechanical testing were performed on the distracted right tibiae and the left tibiae which served as a control group. The local low-dose alendronate group showed a mean increase in bone mineral density of 124.3 mg/cm3 over the local saline group (analysis of variance, p < 0.05) without any adverse effect on the left control tibiae.

The findings indicate that the administration of local low-dose alendronate could be an effective pharmacological means of improving bone formation in distraction osteogenesis.