Advertisement for orthosearch.org.uk
Results 1 - 20 of 732
Results per page:
Bone & Joint Research
Vol. 4, Issue 7 | Pages 120 - 127
1 Jul 2015
Ramkumar PN Harris JD Noble PC

Objectives. A lack of connection between surgeons and patients in evaluating the outcome of total knee arthroplasty (TKA) has led to the search for the ideal patient-reported outcome measure (PROM) to evaluate these procedures. We hypothesised that the desired psychometric properties of the ideal outcome tool have not been uniformly addressed in studies describing TKA PROMS. Methods. A systematic review was conducted investigating one or more facets of patient-reported scores for measuring primary TKA outcome. Studies were analysed by study design, subject demographics, surgical technique, and follow-up adequacy, with the ‘gold standard’ of psychometric properties being systematic development, validity, reliability, and responsiveness. Results. A total of 38 articles reported outcomes from 47 different PROMS to 85 541 subjects at 26.3 months (standard deviation 30.8) post-operatively. Of the 38, eight developed new scores, 20 evaluated existing scores, and ten were cross-cultural adaptation of existing scores. Only six of 38 surveyed studies acknowledged all ‘gold standard’ psychometric properties. The most commonly studied PROMS were the Oxford Knee Score, New Knee Society Score, Osteoarthritis Outcome Score, and Western Ontario and McMaster Universities Osteoarthritis Index. Conclusions. A single, validated, reliable, and responsive PROM addressing TKA patients’ priorities has not yet been identified. Moreover, a clear definition of a successful procedure remains elusive. Cite this article: Bone Joint Res 2015;4:120–127


Bone & Joint Open
Vol. 4, Issue 5 | Pages 338 - 356
10 May 2023
Belt M Robben B Smolders JMH Schreurs BW Hannink G Smulders K

Aims. To map literature on prognostic factors related to outcomes of revision total knee arthroplasty (rTKA), to identify extensively studied factors and to guide future research into what domains need further exploration. Methods. We performed a systematic literature search in MEDLINE, Embase, and Web of Science. The search string included multiple synonyms of the following keywords: "revision TKA", "outcome" and "prognostic factor". We searched for studies assessing the association between at least one prognostic factor and at least one outcome measure after rTKA surgery. Data on sample size, study design, prognostic factors, outcomes, and the direction of the association was extracted and included in an evidence map. Results. After screening of 5,660 articles, we included 166 studies reporting prognostic factors for outcomes after rTKA, with a median sample size of 319 patients (30 to 303,867). Overall, 50% of the studies reported prospectively collected data, and 61% of the studies were performed in a single centre. In some studies, multiple associations were reported; 180 different prognostic factors were reported in these studies. The three most frequently studied prognostic factors were reason for revision (213 times), sex (125 times), and BMI (117 times). Studies focusing on functional scores and patient-reported outcome measures as prognostic factor for the outcome after surgery were limited (n = 42). The studies reported 154 different outcomes. The most commonly reported outcomes after rTKA were: re-revision (155 times), readmission (88 times), and reinfection (85 times). Only five studies included costs as outcome. Conclusion. Outcomes and prognostic factors that are routinely registered as part of clinical practice (e.g. BMI, sex, complications) or in (inter)national registries are studied frequently. Studies on prognostic factors, such as functional and sociodemographic status, and outcomes as healthcare costs, cognitive and mental function, and psychosocial impact are scarce, while they have been shown to be important for patients with osteoarthritis. Cite this article: Bone Jt Open 2023;4(5):338–356


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 20 - 20
1 Oct 2019
Hu DA Harold RE Woeltjen BL Stulberg SD
Full Access

Introduction. Total Knee Arthroplasty (TKA) has been demonstrated to drastically improve a patient's quality of life. The outcomes following TKA are often reported by subjective patient reported outcome measurements (PROMs). However, there are few objective outcome measures following TKA, limiting the amount of information physicians can use to effectively guide a patient's recovery, especially in the first 3 weeks. Newly developed knee sensors have been able to ameliorate this problem by providing the physician with previously unobtainable objective data. Our study aims to evaluate the use of a wearable knee sensor device to measure functional outcomes (range of motion and steps) in real time. Methods. 29 patients who underwent primary, unilateral TKA were recruited for this IRB approved study. Patients were instructed how to use the device and associated mobile phone application preoperatively (Figure 1) and provided knee sensors to wear postoperatively (Figure 2). Patients wore the device for 3 weeks postoperatively to allow for data collection. The device recorded range of motion, number of steps, and percentage of physical therapy exercises completed. Patients were grouped by gender, age (<69 or >=70 years old), and BMI (<30 and >=30 kg/m2) for analysis of functional outcome measurements (maximum flexion, minimum extension, and number of steps). Unpaired two-sample t-tests were used to analyze differences between the groups. Results. Patients were able to tolerate wearing the device without complication and the device collected functional outcome data appropriately as designed. After brief instruction, both patients and physicians were able to monitor patient data via the mobile phone application in real time. The mean maximum flexion and minimum extension did not significantly change from postoperative week 1 to postoperative week 2 and week 3. However, the mean number of steps taken increased from 4,923 steps in postoperative week 1 to 8,163 steps week 2 (p=0.01) and 11,615 steps week 3 (p<0.001) postoperatively. There were no statistically significant differences in maximum flexion, minimum extension, and number of steps between the different gender, age, and BMI groups. Discussion and Conclusion. The knee sensor device used in our study proved to be useful in providing objective functional outcomes following TKA. The device was well tolerated by patients and the mobile phone applications were easy to use for the physicians and the patients. Real time tracking of patients' own range of motion, number of steps, and percentage of exercises completed may motivate them to further their own recovery process. There were wide ranges in the number of steps taken during each postoperative time interval. These results may help identify individuals who are recovering at a faster rate or those who may need more focused physical therapy. Subsequent larger studies can utilize the device to elucidate previously unknown recovery trends among different groups of patients following TKA. In the future, the device's ability to collect real time functional outcome data will allow physicians and other healthcare providers to create individualized physical therapy plans, thereby optimizing the patient's recovery process. For figures, tables, or references, please contact authors directly


Aims

To identify the responsiveness, minimal clinically important difference (MCID), minimal clinical important change (MIC), and patient-acceptable symptom state (PASS) thresholds in the 36-item Short Form Health Survey questionnaire (SF-36) (v2) for each of the eight dimensions and the total score following total knee arthroplasty (TKA).

Methods

There were 3,321 patients undergoing primary TKA with preoperative and one-year postoperative SF-36 scores. At one-year patients were asked how satisfied they were and “How much did the knee arthroplasty surgery improve the quality of your life?”, which was graded as: great, moderate, little (n = 277), none (n = 98), or worse.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 74 - 74
1 Oct 2018
Balestracci KMB Zimmerman S George EJ Kurkurina E Susana-Castillo S Ngo C Mei H Bozic K Lin Z Suter LG
Full Access

Introduction. Patient-reported outcome (PRO) data are variably collected before and after total hip/knee arthroplasty (THA/TKA). We assessed the generalizability of incentivized, prospectively collected PRO data for THA/TKA patient-reported outcome performance measure (PRO-PM) development. Methods. The Centers for Medicare & Medicaid Services (CMS) received PRO data voluntarily submitted by hospitals in a bundled payment model for THA/TKA procedures. Participating hospitals who collected and successfully submitted these data received an increase in their overall quality score, possibly resulting in a positive impact on model reconciliation payments. PRO data were collected from Medicare Fee-For-Service beneficiaries >= 65 years undergoing elective primary THA/TKA procedures from July 1 to August 31, 2016 at hospitals participating in the model. Pre-operative PRO and risk variable data were collected 0 – 90 days prior to surgery, while post-operative PRO data were collected 270 – 365 days following elective THA/TKA. PRO pre-op and post-op data were matched to Medicare claims data for determination of clinically eligible procedures and clinical comorbidities. We compared the characteristics of patients submitting PRO data to other elective primary THA/TKA recipients in the US. Results. Four patient characteristics were associated with HOOS Jr. mean change scores (sex, narcotic use in past 90 days, other joint pain, and back pain) and four with KOOS Jr. mean change scores (sex, Hispanic ethnicity, other joint pain, and back pain). The frequency of simultaneous bilateral procedures, dementia, trauma, and dialysis were statistically significantly lower in patients submitting PRO data compared to other US Medicare beneficiaries undergoing elective primary THA/TKA, but no difference was greater than 1.5% absolute percentage points between groups. Conclusions. Offering financial incentives in alternative payment models to encourage PRO data collection and submission can produce generalizable data for PRO measure development. The possibility of non-respondent biases will need to be specifically considered in measure development


Bone & Joint Research
Vol. 1, Issue 10 | Pages 263 - 271
1 Oct 2012
Sharma GB Saevarsson SK Amiri S Montgomery S Ramm H Lichti DD Lieck R Zachow S Anglin C

Objectives. Numerous complications following total knee replacement (TKR) relate to the patellofemoral (PF) joint, including pain and patellar maltracking, yet the options for in vivo imaging of the PF joint are limited, especially after TKR. We propose a novel sequential biplane radiological method that permits accurate tracking of the PF and tibiofemoral (TF) joints throughout the range of movement under weightbearing, and test it in knees pre- and post-arthroplasty. Methods. A total of three knees with end-stage osteoarthritis and three knees that had undergone TKR at more than one year’s follow-up were investigated. In each knee, sequential biplane radiological images were acquired from the sagittal direction (i.e. horizontal X-ray source and 10° below horizontal) for a sequence of eight flexion angles. Three-dimensional implant or bone models were matched to the biplane images to compute the six degrees of freedom of PF tracking and TF kinematics, and other clinical measures. Results. The mean and standard deviation for the six degrees of freedom of PF tracking and TF kinematics were computed. TF and PF kinematics were highly accurate (< 0.9 mm, < 0.6°) and repeatable. Conclusions. The developed method permitted measuring of in vivo PF tracking and TF kinematics before and after TKR throughout the range of movement. This method could be a useful tool for investigating differences between cohorts of patients (e.g., with and without pain) impacting clinical decision-making regarding surgical technique, revision surgery or implant design


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 38 - 44
1 Jan 2013
Williams DP Price AJ Beard DJ Hadfield SG Arden NK Murray DW Field RE

We present a comparison of patient-reported outcomes (PROMs) in relation to patient age, in patients who had received a total (TKR) or unicompartmental knee replacement (UKR). The outcome was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D) and satisfaction scores. Patients aged 65 to 84 years demonstrated better pre-operative function scores than those aged < 65 years (OKS, p = 0.03; EQ-5D, p = 0.048) and those aged ≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable across age groups, but a linear trend for greater post-operative improvement in OKS and EQ-5D was seen with decreasing age (p < 0.033). The overall mean satisfaction score at six months was 84.9, but those aged <  55 years exhibited a lower mean level of satisfaction (78.3) compared with all other age groups (all p < 0.031). The cumulative overall two-year revision rate was 1.3%. This study demonstrates that good early outcomes, as measured by the OKS and EQ-5D, can be anticipated following knee replacement regardless of the patient’s age, although younger patients gain greater improvement. However, the lower satisfaction in those aged < 55 years is a concern, and suggests that outcome is not fully encapsulated by the OKS and EQ-5D evaluation, and raises the question whether the OKS alone is an appropriate measure of pain and function in younger, more active individuals. Cite this article: Bone Joint J 2013;95-B:38–44


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 919 - 927
1 Jul 2012
Baker PN Petheram T Jameson SS Avery PJ Reed MR Gregg PJ Deehan DJ

Following arthroplasty of the knee, the patient’s perception of improvement in symptoms is fundamental to the assessment of outcome. Better clinical outcome may offset the inferior survival observed for some types of implant. By examining linked National Joint Registry (NJR) and patient-reported outcome measures (PROMs) data, we aimed to compare PROMs collected at a minimum of six months post-operatively for total (TKR: n = 23 393) and unicondylar knee replacements (UKR: n = 505). Improvements in knee-specific (Oxford knee score, OKS) and generic (EuroQol, EQ-5D) scores were compared and adjusted for case-mix differences using multiple regression. Whereas the improvements in the OKS and EQ-5D were significantly greater for TKR than for UKR, once adjustments were made for case-mix differences and pre-operative score, the improvements in the two scores were not significantly different. The adjusted mean differences in the improvement of OKS and EQ-5D were 0.0 (95% confidence interval (CI) -0.9 to 0.9; p = 0.96) and 0.009 (95% CI -0.034 to 0.015; p = 0.37), respectively. We found no difference in the improvement of either knee-specific or general health outcomes between TKR and UKR in a large cohort of registry patients. With concerns about significantly higher revision rates for UKR observed in worldwide registries, we question the widespread use of an arthroplasty that does not confer a significant benefit in clinical outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 24 - 24
1 Jul 2012
van der Linden M Kumaran BR Wade F Nutton R
Full Access

This study aimed to answer the following two questions. Firstly, which activities do people waiting for a total knee arthroplasty rate as important? Secondly, does their self-rated performance of these activities improve after surgery?. Methods. The Canadian Occupational Performance Measure (COPM) was originally designed for use by occupational therapists in order to assess the level of occupational performance and the change in self-perception of their performance over time. COPM is now widely being used as a tool for outcome measurement in a variety of studies such as before and after total hip replacement. However, no reports have been published regarding the outcome of TKA. Fifty five participants underwent a semi-structured interview in which they were asked to list the activities which they felt were most problematic because of their knee osteoarthritis. For the five most important activities they were asked to rate their performance on a scale of 1-10 (1 =unable, 10 = perfectly able). Other outcome measures included the WOMAC, the Knee Society Score (KSS) and the SF36. Result. All outcome measures showed a significant improvement after surgery (all p<0.001). Average COPM score improved from 3.8 before to 6.4 one year after surgery. The change in the COPM demonstrated a moderate correlation with SF-36 physical component, a fair correlation with all three WOMAC scores and a fair correlation with the KSS function scores. The five most reported activities were ascending and descending stairs (93%), walking, (89%) gardening (35%), playing golf (24%) and kneeling.(18%). The subjective performance of the first four activities improved significantly. However, participants reported a decrease in kneeling ability. Conclusion. This study showed that the COPM is responsive and associated with other common outcome measures. On average most activities were rated with higher performance scores but others such as kneeling was not. This information should assist the guidance of patient expectations


The Bone & Joint Journal
Vol. 99-B, Issue 10 | Pages 1329 - 1334
1 Oct 2017
Lim JBT Chong HC Pang HN Tay KJD Chia SL Lo NN Yeo SJ

Aims. Little is known about the relative outcomes of revision of unicompartmental knee arthroplasty (UKA) and high tibial osteotomy (HTO) to total knee arthroplasty (TKA). The aim of this study is to compare the outcomes of revision surgery for the two procedures in terms of complications, re-revision and patient-reported outcome measures (PROMs) at a minimum of two years follow-up. Patients and Methods. This study was a retrospective review of data from an institutional arthroplasty registry for cases performed between 2001 and 2014. A total of 292 patients were identified, of which 217 had a revision of HTO to TKA, and 75 had revision of UKA to TKA. While mean follow-up was longer for the HTO group compared with the UKA group, patient demographics (age, body mass index and Charlson co-morbidity index) and PROMs (Short Form-36, Oxford Knee Score, Knee Society Score, both objective and functional) were similar in the two groups prior to revision surgery. Outcomes included the rate of complications and re-operation, PROMS and patient-reported satisfaction at six months and two years post-operatively. We also compared the duration of surgery and the need for revision implants in the two groups. . Results . At two-year follow-up, both groups of patients had made significant improvement in terms of PROMs compared with pre-operative scores. PROMs and satisfaction rates were similar in the two groups. Complications requiring re-operation were significantly more frequent in the HTO group whilst more revision implants were used in the UKA group, resulting in a longer operative duration. . Conclusion. Revision of HTO and UKA achieve similar post-operative PROMs and satisfaction. Revision of UKA more frequently requires revision components with increased operation duration but fewer complications requiring re-operation compared with revision of HTO. . Cite this article: Bone Joint J 2017;99-B:1329–34


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1058 - 1066
1 Aug 2012
Baker PN Deehan DJ Lees D Jameson S Avery PJ Gregg PJ Reed MR

Patient-reported outcome measures (PROMs) are increasingly being used to assess functional outcome and patient satisfaction. They provide a framework for comparisons between surgical units, and individual surgeons for benchmarking and financial remuneration. Better performance may bring the reward of more customers as patients and commissioners seek out high performers for their elective procedures. Using National Joint Registry (NJR) data linked to PROMs we identified 22 691 primary total knee replacements (TKRs) undertaken for osteoarthritis in England and Wales between August 2008 and February 2011, and identified the surgical factors that influenced the improvements in the Oxford knee score (OKS) and EuroQol-5D (EQ-5D) assessment using multiple regression analysis. After correction for patient factors the only surgical factors that influenced PROMs were implant brand and hospital type (both p < 0.001). However, the effects of surgical factors upon the PROMs were modest compared with patient factors. For both the OKS and the EQ-5D the most important factors influencing the improvement in PROMs were the corresponding pre-operative score and the patient’s general health status. Despite having only a small effect on PROMs, this study has shown that both implant brand and hospital type do influence reported subjective functional scores following TKR. In the current climate of financial austerity, proposed performance-based remuneration and wider patient choice, it would seem unwise to ignore these effects and the influence of a range of additional patient factors


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 19 - 19
1 Oct 2019
Berend KR Lombardi AV Crawford DA Hurst JM Morris MJ
Full Access

Introduction

A smartphone-based care platform allows a customizable educational and exercise interface with patients, allowing many to recover after surgery without the need for formal physical therapy (PT). Furthermore, advances in wearable technology to monitor physical activity (PA) provides patients and physicians quantifiable metrics of the patient's recovery. The purpose of this study is to determine the feasibility of a smartphone-based exercise educational platform after primary knee arthroplasty as well as identifying factors that may predict the need for formal physical therapy.

Methods

This study is part of a multi-institution, prospective study of patients after primary total knee arthroplasty (TKA) and partial knee arthroplasty (PKA) enrolled in a smartphone with smartwatch-based episode of care platform that recorded multimodal PA (steps, kcal, stairs). Postoperatively, all patients initially followed the smartphone-based exercise program. At the surgeon's discretion, patients were prescribed therapy if needed. The outcome of this study was the need for PT outside the app-based exercise program as well as time to return to preoperative step count. Variables assessed were preoperative weekly step counts (steps/day), weekly postoperative activity level (weekly step count compared to preoperative level), compliance with the exercise program (>75% completion) and patient demographic data including gender, age, BMI and narcotic use. One hundred eighty-eight patients were included in analysis: 45 PKA (24%) and 143 TKA (76%). Step count data was available on 135 patients and physical therapy data on 174.


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1081 - 1086
1 Sep 2019
Murphy WS Harris S Pahalyants V Zaki MM Lin B Cheng T Talmo C Murphy SB

Aims

The practice of alternating operating theatres has long been used to reduce surgeon idle time between cases. However, concerns have been raised as to the safety of this practice. We assessed the payments and outcomes of total knee arthroplasty (TKA) performed during overlapping and nonoverlapping days, also comparing the total number of the surgeon’s cases and the total time spent in the operating theatre per day.

Materials and Methods

A retrospective analysis was performed on the Centers for Medicare & Medicaid Services (CMS) Limited Data Set (LDS) on all primary elective TKAs performed at the New England Baptist Hospital between January 2013 and June 2016. Using theatre records, episodes were categorized into days where a surgeon performed overlapping and nonoverlapping lists. Clinical outcomes, economic outcomes, and demographic factors were calculated. A regression model controlling for the patient-specific factors was used to compare groups. Total orthopaedic cases and aggregate time spent operating (time between skin incision and closure) were also compared.


Bone & Joint 360
Vol. 1, Issue 1 | Pages 28 - 29
1 Feb 2012
Mohtadi N


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 74 - 74
7 Aug 2023
Alabdullah M Liu A Xie S
Full Access

Abstract. Rehabilitation exercise is critical for patients’ recovery after knee injury or post-surgery. Unfortunately, adherence to exercise is low due to a lack of positive feedback and poor self-motivation. Therefore, it is crucial to monitor their progress and provide supervision. Inertial measurement unit (IMUs) based sensing technology can provide remote patient monitoring functions. However, most current solutions only measure the range of knee motion in one degree of freedom. The current IMUs estimate the orientation-angle based on the integrated raw data, which might lack accuracy in measuring knee motion. This study aims to develop an IMU-based sensing system using the absolute measured orientation-angle to provide more accurate comprehensive monitoring by measuring the knee rotational angles. An IMU sensing system monitoring the knee joint angles, flexion/extension (FE), adduction/abduction (AA), and internal/external (IE) was developed. The accuracy and reliability of FE measurements were validated in human participants during squat exercise using measures including root mean square error (RMSE) and correlation coefficient. The RMSE of the three knee angles (FE, AA, and IE) were 0.82°, 0.26°, and 0.11°, which are acceptable for assessing knee motion. The FE measurement was validated in human participants and showed excellent accuracy (correlation coefficient of 0.99°). Further validation of AA and IE in human participants is underway. The sensing system showed the capability to estimate three knee rotation angles (FE, AA, and IE). It showed the potential to provide comprehensive continuous monitoring for knee rehabilitation exercises, which can also be used as a clinical assessment tool


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 60 - 60
7 Aug 2023
Mikova E Kunutsor S Butler M Murray J
Full Access

Abstract. Introduction. Active, middle-aged patients with symptomatic cartilage or osteochondral defects can find themselves in a treatment gap when they have failed conservative measures but are not yet eligible for conventional arthroplasty. Data from various cohort studies suggests that focal knee resurfacing implants such as HemiCAP, UniCAP, Episealer or BioBoly are cost-effective solutions to alleviate pain, improve function and delay or eliminate the need for conventional replacement. A systematic review and meta-analysis were conducted in order to(i) evaluate revision rates and implant survival of focal resurfacing; (ii) explore surgical complications; and (iii) evaluate various patient reported clinical outcome measures. Methodology. PubMED, Cochrane Library and Medline databases were searched in February 2022 for prospective and retrospective cohort studies evaluating any of the available implant types. Data on incidence of revision, complications and various patient reported outcome measures was sourced. Results. A total of 24 unique studies were identified with a total of 1465 enrolled patients. A revision rate of 12.97% over a 5.9 year weighted mean follow-up period was observed across all implant types. However, in one series a Kaplan-Meir survival as high as 92.6% at a 10-year follow-up period was noted. A statistically significant improvement was documented across multiple subjective clinical outcomes scores. There was a low reported incidence of post-operative complications such as aseptic loosening or deep wound infection. Conclusions. Focal femoral resurfacing appears to be a viable treatment option for focal symptomatic chondral lesions in patients beyond biological reconstruction, with low revision rates and high patient satisfaction


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 53 - 53
7 Aug 2023
Arthur J Makovicka J Bingham J Spangehl M Clarke H Dossett HG
Full Access

Abstract. Introduction. The optimal alignment technique for total knee replacement (TKR) remains controversial. We previously reported six-month and two-year results of a randomized controlled trial comparing kinematically (KA) versus mechanically (MA) aligned TKR. In the present study, we report 12-year results from this trial. Methods. The original cohort included 88 TKRs (44 KA using Shape Match patient-specific guides and 44 MA using conventional instrumentation), performed from 2008 to 2009. After IRB approval, the health record of the original 88 patients were queried. Revisions, re-operations, and complications were recorded. The non-deceased patients were contacted via phone. Reoperation and complications were documented via the patient's history. Further, a battery of patient-reported outcome measures (including patient satisfaction, WOMAC, Oxford, KOOS Jr, Forgotten Joint Score, and M-SANE) were obtained. Results. Of the original 88 patients in the study, 15 patients had a least one reoperation (17%). Patella problems were the most common cause of reoperation accounting for 5/8 reoperations in the KA group versus 3/7 in the MA group. There was no statistically significant difference between the two alignment methods in terms of major and minor complications or reoperations. At the 12-year follow-up, 26 patients died leaving 62 patients for follow-up. Of these, 48 patients (77%) were successfully contacted. The kinematically aligned total knees self-reported better satisfaction (96% versus 82%), but no difference in other patient-reported outcome measures compared to mechanically aligned TKRs. Conclusion. KA TKR demonstrates excellent mid to long-term results compared to MA TKR with similar reoperations, complications, and patient-reported outcome measures


Bone & Joint Research
Vol. 12, Issue 10 | Pages 624 - 635
4 Oct 2023
Harrison CJ Plessen CY Liegl G Rodrigues JN Sabah SA Beard DJ Fischer F

Aims. To map the Oxford Knee Score (OKS) and High Activity Arthroplasty Score (HAAS) items to a common scale, and to investigate the psychometric properties of this new scale for the measurement of knee health. Methods. Patient-reported outcome measure (PROM) data measuring knee health were obtained from the NHS PROMs dataset and Total or Partial Knee Arthroplasty Trial (TOPKAT). Assumptions for common scale modelling were tested. A graded response model (fitted to OKS item responses in the NHS PROMs dataset) was used as an anchor to calibrate paired HAAS items from the TOPKAT dataset. Information curves for the combined OKS-HAAS model were plotted. Bland-Altman analysis was used to compare common scale scores derived from OKS and HAAS items. A conversion table was developed to map between HAAS, OKS, and the common scale. Results. We included 3,329 response sets from 528 patients undergoing knee arthroplasty. These generally met the assumptions of unidimensionality, monotonicity, local independence, and measurement invariance. The HAAS items provided more information than OKS items at high levels of knee health. Combining both instruments resulted in higher test-level information than either instrument alone. The mean error between common scale scores derived from the OKS and HAAS was 0.29 logits. Conclusion. The common scale allowed more precise measurement of knee health than use of either the OKS or HAAS individually. These techniques for mapping PROM instruments may be useful for the standardization of outcome reporting, and pooling results across studies that use either PROM in individual-patient meta-analysis. Cite this article: Bone Joint Res 2023;12(10):624–635


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 450 - 459
1 May 2024
Clement ND Galloway S Baron J Smith K Weir DJ Deehan DJ

Aims. The aim was to assess whether robotic-assisted total knee arthroplasty (rTKA) had greater knee-specific outcomes, improved fulfilment of expectations, health-related quality of life (HRQoL), and patient satisfaction when compared with manual TKA (mTKA). Methods. A randomized controlled trial was undertaken (May 2019 to December 2021), and patients were allocated to either mTKA or rTKA. A total of 100 patients were randomized, 50 to each group, of whom 43 rTKA and 38 mTKA patients were available for review at 12 months following surgery. There were no statistically significant preoperative differences between the groups. The minimal clinically important difference in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score was defined as 7.5 points. Results. There were no clinically or statistically significant differences between the knee-specific measures (WOMAC, Oxford Knee Score (OKS), Forgotten Joint Score (FJS)) or HRQoL measures (EuroQol five-dimension questionnaire (EQ-5D) and EuroQol visual analogue scale (EQ-VAS)) at 12 months between the groups. However, the rTKA group had significantly (p = 0.029) greater improvements in the WOMAC pain component (mean difference 9.7, 95% confidence interval (CI) 1.0 to 18.4) over the postoperative period (two, six, and 12 months), which was clinically meaningful. This was not observed for function (p = 0.248) or total (p = 0.147) WOMAC scores. The rTKA group was significantly (p = 0.039) more likely to have expectation of ‘Relief of daytime pain in the joint’ when compared with the mTKA group. There were no other significant differences in expectations met between the groups. There was no significant difference in patient satisfaction with their knee (p = 0.464), return to work (p = 0.464), activities (p = 0.293), or pain (p = 0.701). Conclusion. Patients undergoing rTKA had a clinically meaningful greater improvement in their knee pain over the first 12 months, and were more likely to have fulfilment of their expectation of daytime pain relief compared with patients undergoing mTKA. However, rTKA was not associated with a clinically significant greater knee-specific function or HRQoL, according to current definitions. Cite this article: Bone Joint J 2024;106-B(5):450–459


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims. Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results. The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion. We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients. Cite this article: Bone Jt Open 2024;5(2):101–108