Introduction. Patellar tendinopathy is a highly prevalent clinical diagnosis supported by ultrasound changes. Numerous interventions are targeted at improving both symptoms and structure of dysfunctional tendons, however little is known of the diagnostic value in a changing ultrasound profile whilst patient reported outcome measures determine recovery. The aim of this study was to assess if change in ultrasound measure is congruent with change in Victorian Institute of Sport Assessment – Patella (VISA-P) score and therefore indicates the use of using ultrasound to assess patellar tendinopathy during symptom change. Method. Four databases (PubMed, Web of Science, Embase, Cinahl) were search in January 2014. Studies selected contained ultrasound and VISA-P scores from ≥ 2 type points. All included studies were quality assessed depending on type and available data underwent meta-analysis. Result. 10 papers of varying study type, of limited to high quality, were synthesised. Meta-analysis indicated that change in ultrasound measure was not congruent with change in VISA-P score. Conclusion. The variation in study quality, along with significant heterogeneity of ultrasound measure outcomes and reporting may influence the congruency of the data, but the association between gradual structure change and varying vascularity with pain or function is questionable throughout tendinopathy literature


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 132 - 132
11 Apr 2023
van Hoogstraten S Arts J
Full Access

Malalignment is often postulated as the main reason for the high failure rate of total ankle replacements (TARs). Only a few studies have been performed to correlate radiographic TAR malalignment to the clinical outcome, but no consistent trends between TAR alignment parameters and the clinical outcome were found. No standard TAR alignment measurement method is present, so reliable comparison between studies is difficult. Standardizing TAR alignment measurements and increasing measurable parameters on radiographs in the clinic might lead to a better insight into the correlation between malalignment and the clinical outcome. This study aims to develop and validate a tool to semi-automatic measure TAR alignment, and to improve alignment measurement on radiographs in the clinic. A tool to semi-automatically measure TAR alignment on anteroposterior and lateral radiographs was developed and used by two observers to measure TAR alignment parameters of ten patients. The Intraclass Coefficient (ICC) was calculated and accuracy was compared to the manual measurement method commonly used in the clinic. The tool showed an accuracy of 76% compared to 71% for the method used during follow-up in the clinic. ICC values were 0.94 (p<0.01) and higher for both inter-and intra-observer reliability. The tool presents an accurate, consistent, and reliable method to measure TAR alignment parameters. Three-dimensional alignment parameters are obtained from two-dimensional radiographs, and as the tool can be applied to any TAR design, it offers a valuable addition in the clinic and for research purposes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 45 - 45
2 Jan 2024
Gilsing R Hoogeveen M Boers H van der Weegen W
Full Access

Knee swelling is common after injury or surgery, resulting in pain, restricted range of movement and limited mobility. Accurately measuring knee swelling is critical to assess recovery. However, current measurement methods are either unreliable or expensive [1,2]. Therefore, a new measurement method is developed. This wearable (the ‘smart brace’) has shown the ability to distinguish a swollen knee from a not swollen knee using multi-frequency-bio impedance analysis (MF-BIA) [3]. This study aimed to determine the accuracy of this smart brace. The study involved 25 usable measurements on patients treated for unilateral knee osteoartritis with a 5mL injection of Lidocaïne + DepoMedrol (1:4). MF-BIA measurements were taken before and after the injection, both on the treated and untreated knee. The smart brace accurately measured the effect of the injection by a decrease in resistance of up to 2.6% at 100kHz (p<0.01), where commonly used gel electrodes were unable to measure the relative difference. Remarkably, both the smart brace and gel electrodes showed a time component in the MF-BIA measurements. To further investigate this time component, 10 participants were asked to lie down for 30 minutes, with measurements taken every 3 minutes using both gel electrodes and the smart brace on both legs. The relative change between each time step was calculated to determine changes over time. The results showed presence of a physiological aspect (settling of knee fluids), and for the brace also a mechanical aspect (skin-electrode interface) [4]. The mechanical aspect mainly interfered with reactance values. Overall, the smart brace is a feasible method for quantitatively measuring knee swelling as a relative change over time. However, the skin-electrode interface should be improved for reliable measurements at different moments in time. The findings suggest that the smart brace could be a promising tool for monitoring knee swelling during rehabilitation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 59 - 59
17 Apr 2023
Pounds G Liu A Jones A Jennings L
Full Access

The aim of this work was to develop a novel, accessible and low-cost method, which is sufficient to measure changes in meniscal position in a whole-knee joint model performing dynamic motion in a knee simulator. An optical tracking method using motion markers, MATLAB (MATLAB, The MathWorks Inc.) and a miniature camera system (Raspberry Pi, UK) was developed. Method feasibility was assessed on porcine whole joint knee samples (n = 4) dissected and cemented to be used in the simulator (1). Markers were placed on three regions (medial, posterior, anterior) of the medial meniscus with corresponding reference markers on the tibial plateau, so the relative meniscal position could be calculated. The Leeds high kinematics gait profile scaled to the parameters of a pig (1, 2) was driven in displacement control at 0.5 Hz. Videos were recorded at cycle-3 and cycle-50. Conditions tested were the capsule retained (intact), capsule removed and a medial posterior root tear. Mean relative displacement values were taken at time-points relating to the peaks of the axial force and flexion-extension gait inputs, as well as the range between the maximum and minimum values. A one-way ANOVA followed by Tukey post hoc analysis were used to assess differences (p = 0.05). The method was able to measure relative meniscal displacement for all three meniscal regions. The medial region showed the greatest difference between the conditions. A significant increase (p < 0.05) for the root tear condition was found at 0.28s and 0.90s (axial load peaks) during cycle-3. Mean relative displacement for the root tear condition decreased by 0.29 mm between cycle-3 and cycle-50 at the 0.28s time-point. No statistically significant differences were found when ranges were compared at cycle-3 and cycle-50. The method was sensitive to measure a substantial difference in medial-lateral relative displacement between an intact and a torn state. Meniscus extrusion was detected for the root tear condition throughout test duration. Further work will progress onto human specimens and apply an intervention condition


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 27 - 27
1 Mar 2021
van Duren B Lamb J Al-Ashqar M Pandit H Brew C
Full Access

The angle of acetabular inclination is an important measurement in total hip replacement (THR) procedures. Determining the acetabular component orientation intra-operatively remains a challenge. An increasing number of innovators have described techniques and devices to achieve it. This paper describes a mechanical inclinometer design to measure intra-operative acetabular cup inclination. Then, the mechanical device is tested to determine its accuracy. The aim was to design an inclinometer to measure inclination without existing instrumentation modification. The device was designed to meet the following criteria: 1. measure inclination with acceptable accuracy (+/− 5o); 2. easy to use intra-operatively (handling & visualization); 3. adaptable and useable with majority of instrumentation kits without modification; 4. sterilizable by all methods; 5. robust/reusable. The prototype device was drafted by computer aided design (CAD) software. Then a prototype was constructed using a 3D printer to establish the final format. The final device was CNC machined from SAE 304 stainless steel. The design uses an eccentrically weighted flywheel mounted on two W16002-2RS ball bearings pressed into symmetrical housing components. The weighted wheel is engraved with calibrated markings relative to its mass centre. Device functioning is dependent on gravity maintaining the weighted wheel in a fixed orientation while the housing can adapt to the calibration allowing for determining the corresponding measurement. The prototype device accuracy was compared to a digital device. A digital protractor was used to create an angle. The mechanical inclinometer (user blinded to digital reading) was used to determine the angle and compared to the digital reading. The accuracy of the device compared to the standard freehand technique was assessed using a saw bone pelvis fixed in a lateral decubitus position. 18 surgeons (6 expert, 6 intermediate, 6 novice) were asked to place an uncemented acetabular cup in a saw bone pelvis to a target of 40 degrees. First freehand then using the inclinometer. The inclination was determined using a custom-built inertial measurement unit with the user blinded to the result. Comparison between the mechanical and digital devices showed that the mechanical device had an average error of −0.2, a standard deviation of 1.5, and range −3.3 to 2.6. The average root mean square error was 1.1 with a standard deviation of 0.9. Comparison of the inclinometer to the freehand technique showed that with the freehand component placement 50% of the surgeons were outside the acceptable range of 35–45 degrees. The use of the inclinometer resulted all participants to achieve placement within the acceptable range. It was noted that expert surgeons were more accurate at achieving the target inclination when compared to less experienced surgeons. This work demonstrates that the design and initial testing of a mechanical inclinometer is suitable for use in determining the acetabular cup inclination in THR. Experimental testing showed that the device is accurate to within acceptable limits and reliably improved the accuracy of uncemented cup implantation in all surgeons


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 50 - 50
17 Nov 2023
Williams D Ward M Kelly E Shillabeer D Williams J Javadi A Holsgrove T Meakin J Holt C
Full Access

Abstract. Objectives. Spinal disorders such as back pain incur a substantial societal and economic burden. Unfortunately, there is lack of understanding and treatment of these disorders are further impeded by the inability to assess spinal forces in vivo. The aim of this project is to address this challenge by developing and testing a novel image-driven approach that will assess the forces in an individual's spine in vivo by incorporating information acquired from multimodal imaging (magnetic resonance imaging (MRI) and biplane X-rays) in a subject-specific model. Methods. Magnetic resonance and biplane X-ray imaging are used to capture information about the anatomy, tissues, and motion of an individual's spine as they perform a range of everyday activities. This information is then utilised in a subject-specific computational model based on the finite element method to predict the forces in their spine. The project is also utilising novel machine learning algorithms and in vitro, six-axis mechanical testing on human, porcine and bovine samples to develop and test the modelling methods rigorously. Results & Discussion. MRI sequences have been identified that provide high-quality image data and information on different tissue types which will be used to predict subject-specific disc properties. In-vivo protocols to capture motion analysis, EMG muscle activity, and video X-rays of the spine have been designed with planned data collection of 15 healthy volunteers. Preliminary modelling work has evaluated potential machine learning approaches and quantified the sensitivity of the models developed to material properties. Conclusion. The development and testing of these image-driven subject-specific spine models will provide a new tool for determining forces in the spine. It will also provide new tools for measuring and modelling spine movement and quantifying the properties of the spinal tissues. Acknowledgments. Funding from the EPSRC: EP/V036602/1 (Meakin, Holsgrove & Javadi) and EP/V032275/1 (Holt & Williams). Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 84 - 84
11 Apr 2023
Amirouche F Leonardo Diaz R Koh J Lin C Motisi M Mayo B Tafur J Hutchinson M
Full Access

Postoperative knee stability is critical in determining the success after reconstruction; however, only posterior and anterior stability is assessed. Therefore, this study investigates medial and lateral rotational knee laxity changes after partial and complete PCL tear and after PCL allograft reconstruction.

The extending Lachman test assessed knee instability in six fresh-frozen human cadaveric knees. Tibia rotation was measured for the native knee, after partial PCLT (pPCLT), after full PCLT (fPCLT), and then after PCLR tensioned at 30° and 90°. In addition, tests were performed for the medial and lateral sides. The tibia was pulled with 130N using a digital force gauge. A compression load of 50N was applied to the joint on the universal testing machine (MTS Systems) to induce contact. Three-dimensional tibial rotation was measured using a motion capture system (Optotrak).

On average, the tibia rotation increased by 33%-42% after partial PCL tear, and by 62%-75% after full PCL tear when compared to the intact case. After PCL reconstruction, the medial tibia rotation decreased by 33% and 37% compared to the fPCL tear in the case that the allograft was tensioned at 30° and 90° of flexion, respectively. Similarly, lateral tibial rotation decreased by 15% and 2% for allograft tensioned at 30° and 90° of flexion respectively, compared to the full tear. Rotational decreases were statistically significant (p<0.005) at the lateral pulling after tensioning the allograft at 90°.

PCLR with the graft tensioned at 30° and 90° both reduced medial knee laxity after PCLT. These results suggest that while both tensioning angles restored medial knee stability, tensioning the Achilles graft at 30° of knee flexion was more effective in restoring lateral knee stability throughout the range of motion from full extension to 90° flexion, offering a closer biomechanical resemblance to native knee function.


Bone & Joint Research
Vol. 6, Issue 9 | Pages 542 - 549
1 Sep 2017
Arnold M Zhao S Ma S Giuliani F Hansen U Cobb JP Abel RL Boughton O

Objectives. Microindentation has the potential to measure the stiffness of an individual patient’s bone. Bone stiffness plays a crucial role in the press-fit stability of orthopaedic implants. Arming surgeons with accurate bone stiffness information may reduce surgical complications including periprosthetic fractures. The question addressed with this systematic review is whether microindentation can accurately measure cortical bone stiffness. Methods. A systematic review of all English language articles using a keyword search was undertaken using Medline, Embase, PubMed, Scopus and Cochrane databases. Studies that only used nanoindentation, cancellous bone or animal tissue were excluded. Results. A total of 1094 abstracts were retrieved and 32 papers were included in the analysis, 20 of which used reference point indentation, and 12 of which used traditional depth-sensing indentation. There are several factors that must be considered when using microindentation, such as tip size, depth and method of analysis. Only two studies validated microindentation against traditional mechanical testing techniques. Both studies used reference point indentation (RPI), with one showing that RPI parameters correlate well with mechanical testing, but the other suggested that they do not. Conclusion. Microindentation has been used in various studies to assess bone stiffness, but only two studies with conflicting results compared microindentation with traditional mechanical testing techniques. Further research, including more studies comparing microindentation with other mechanical testing methods, is needed before microindentation can be used reliably to calculate cortical bone stiffness. Cite this article: M. Arnold, S. Zhao, S. Ma, F. Giuliani, U. Hansen, J. P. Cobb, R. L. Abel, O. Boughton. Microindentation – a tool for measuring cortical bone stiffness? A systematic review. Bone Joint Res 2017;6:542–549. DOI: 10.1302/2046-3758.69.BJR-2016-0317.R2


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 42 - 42
1 Mar 2021
Quarshie R Marway S Logishetty K Keane B Cobb JP
Full Access

Patients undergoing hip resurfacing arthroplasty (HRA) is typically reserved for highly active patients. Patient Reported Outcome Measures (PROMs) such as the Oxford Hip Score (OHS) are reported to have ceiling effects, which may limit physicians' ability to measure health gain in these patients. The Metabolic Equivalent of Task (MET) index is a validated compendium assigning energy expenditure to a wide range of activities; for example, a slow walk expends 2.9 kcal/kg/hour, golf expends 4.0 kcal/kg/hour, while moderate lacrosse typically expends 8.1 kcal/kg/hour. We hypothesized that for patients with high OHS (47–48) after HRA, the MET index could better discriminate between high-performing individuals. We evaluated 97 consecutive HRA patients performed by a single surgeon. They prospectively completed an online Oxford Hip Score. They also listed three activities which they had performed independently in the preceding 2 weeks with a Likert-scale slider denoting intensity of effort. Matched data-sets were obtained from 51 patients, from which 23 had OHS of 47–48 at 6-months. Their activity with the highest MET index was selected for analysis. The 23 patients' OHS improved from 29.3 ± 7.0 preoperatively to 47.6 ± 0.5 after 6-months, while their MET indices improved from 8.5 ± 3.7 to 12.9 ± 3.5 kcal/kg/hr. The activities performed by these high-performance individuals ranged from the lowest, pilates (8.05 kcal/kg/hour), to highest, running at 22km/hr (23 kcal/kg/hour). 45% of patients undergoing HRA in this cohort had OHS of 47 and 48 at 6-months after surgery. Unlike the OHS, the MET index described variation in physical activity in these high-performance individuals, and did so on an objective measurable scale


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 100 - 100
1 May 2012
Bills P Underwood RJ Cann PM Hart A
Full Access

INTRODUCTION. There is increasing worldwide interest in the assessment of wear in explanted hip components. This is due is part to high profile failures of orthopaedic components in the US, whilst in the UK hip resurfacings have been experiencing a higher than expected failure rate. The reasons for these failures are not well understood, with data from the NJR suggesting the 43% of MoM resurfacing failures are unexplained. Wear analysis is a vital tool in determining failure mechanisms and ultimately improving the longevity of joint replacements through improved design and manufacturing control. There are currently no relevant measurement standards for the evaluation of retrieved orthopaedic components. This paper will assess two of the most commonly used techniques namely roundness measurement and co-ordinate measurement. The advantages and disadvantages of both techniques are considered in this paper. ROUNDNESS MACHINE. The Talyrond 365 is a stylus based roundness machine. The component is located on a rotating table and the stylus measures the deviation from a perfect circle as the component is slowly rotated. The Talyrond measures a single profile to an accuracy of 30 nm and up to 72,000 data points per revolution. The air spindle has a radial accuracy of <0.02 μm and the Talymin gauge a minimum resolution of 12 nm. Individual roundness profiles can be stitched together to build up 3D cylinder maps, allowing 3D pictures of sections of explanted hip components to be generated. COORDINATE MEASURING MACHINE. Co-ordinate measuring machines (CMMs) have been widely used in manufacturing quality and research departments for a number of years and the CMM is recognised as a powerful and important tool capable of ascertaining geometric data from a component. The CMM used in this study was a Zeiss Prismo CMM (Carl Zeiss Ltd., Rugby, UK) with a probing error of 0.7 μm. Components are securely held in a chuck fixture arrangement and the dimensions of the component in the portion of the bearing that is unworn is ascertained through measurement. The initial measurements are used to produce a reverse engineered 3D CAD surface which represents the component ‘pre-wear’ surface. The surface of the component is then scanned and the deviation from this pre-wear surface is mapped. The maximum linear wear and wear volume are then calculated directly. DISCUSSION. The main advantage of CMM and Talyrond is that they are available in most metrology and measurement rooms. The CMM is a particularly versatile machine and can be used to measure any orthopaedic components. There is a need to develop a suitable Standard for both machines detailing a protocol to measure explanted hip and quantify the wear. A study is underway to measure a set of explanted hip components to allow a detailed comparison between of measurements between the Talyrond and CMM. The result of this study will be included in the paper. CONCLUSIONS. The CMM and Talyrond are both instruments suited to measuring wear of explanted hips. A full evaluation of the systems and the development of robust measurement protocol and standard would be advantageous to the orthopaedic industry


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 137 - 137
1 Jul 2014
Shareghi B Kärrholm J
Full Access

Summary. Comparison of accuracy and precision in measuring wear using 4 commonly used uncemented cup designs shows small differences in mean and data scatter for marker and model-based RSA. Introduction. The disadvantage with conventional RSA is that implant has to be supplied with tantalum markers, which may be difficult to visualise. This problem can be resolved with model-based RSA, but it is uncertain if this method has the same precision as marker-based RSA to measure wear. We compared these methods and studied different prosthesis geometries represented by four different uncemented cup designs (Trilogy, TMT-Trabecular Metal, Zimmer, Warsaw, USA, Ringloc, Biomet, Inc., Warsaw, Indiana, and ABG, Howmedica International, Staines, UK). Patients and Methods. Stereoradiographs of 75 patients (19 Trilogy, 17 TMT, 20 Ringloc, 19 ABG) were exposed postoperatively (2 examinations) and after 2 years. The patients were selected from prospective clinical studies. During operation tantalum markers had been inserted into the liner in all cases. The measurements and analysis of all radiographs were performed with UmRSA Digital Measure and UmRSA Analysis 6.0. We used the differences between the postoperative double-examinations to compute the precision for the two methods and for the different implant designs. The proximal and the total (vectorial sum of medial/lateral, proximal/distal and anterior posterior) femoral head penetration up to 2 years were compared. Results. The mean differences and the standard deviation of mean obtained from calculations between the double examinations in the total material did not differ between the 2 methods for any of the designs studied. The mean values and SD for marker and model-based RSA were −0, 00 mm ± 0.09 mm and 0.02 mm ± 0.08 mm, respectively (p>0.05). The comparison between Classical marker-based RSA and Model-based RSA in measuring wear up to 2 years did not showed any statistically significant differences for the Trilogy, TMT and ABG cups (p>0.05). However the mean difference of the postoperative double examinations were slightly higher for the Ringloc design (p=0, 02) and the data scatter (SD) at 2 years was higher (p=0,004) with use of model-based RSA. Conclusions. We found small differences between marker and model-based RSA for measurements of proximal and total wear (penetration). In 3 of the 4 cup designs studied the data scatter was about equal for the 2 methods. In the 4. th. design (Ringloc) the data scatter was higher when model-based RSA was used


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 9 - 9
1 Jan 2017
Boey H Natsakis T Van Dijck C Coudyzer W Dereymaeker G Jonkers I Vander Sloten J
Full Access

Four-dimensional computed tomography (4DCT: three dimensional + time) allows to measure individual bone position over a period of time usually during motion. This method has been found useful in studying the joints around the wrist as dynamic instabilities are difficult to detect during static CT scans while they can be diagnosed using a 4DCT scan [1]–[3]. For the foot, the PedCAT system (Curvebeam, Warrington, USA) has been developed to study the foot bones under full weight bearing, however its use is limited to static images. On the contrary, dynamic measurements of the foot kinematics using skin markers can only describe motion of foot segments and not of individual bones. However, the ability to measure individual bone kinematics during gait is of paramount importance as such detailed information could be used to detect instabilities, to evaluate the effect of joint degeneration, to help in pre-operative planning as well as in post-operative evaluation. The overall gait kinematics of two healthy volunteers were measured in a gait analysis lab (Movement Analysis Lab Leuven, Belgium) using a detailed foot-model (Oxford foot model, [4]). The measured plantar-dorsiflexion and in-eversion were used to manipulate their foot during a 4D CT acquisition. The manipulation was performed through a custom made foot manipulator that controls the position and orientation of the foot bed according to input kinematics. The manipulator was compatible with the 4D CT Scanner (Aquilion One, Toshiba, JP), and a sequence of CT scans (37 CT scans over 10 seconds with 320 slices for each scan and a slice thickness of 0.5 mm) was generated over the duration of the simulation. The position of the individual bones was determined using an automatic segmentation routine after which the kinematics of individual foot bones were calculated. To do so, three landmarks were tracked on each bone over time allowing to construct bone-specific coordinate frames. The motion of the foot bed was compared against the calculated kinematics of the tibia-calcaneus as the angles between these two bones are captured with skin markers. There is high repeatability between the imposed plantar/dorsiflexion and inversion/eversion and the calculated. Although the internal/external rotation was not imposed, the calculated kinematics follow the same pattern as the measured in the gait-analysis lab. Based on the validation of the tibia-calcaneus, the kinematics were also calculated between four other joints: tibia-talar, talar-calcaneus, calcaneus-cuboid and talar-navicular. Repeatable measurements of individual foot bone motion were obtained for both volunteers. The use of 4D CT-scanning in combination with a foot manipulator can provide more detailed information than skin marker-based gait-analysis e.g. for the study of the the tibia-talar joint. In the future, the foot manipulator will be tested for its sensitivity for specific pathologies (e.g. metatarsal coalition) and will be further developed to better resemble a real-life stance phase of gait (i.e. to include isolated heel contact and toe off)


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 113 - 113
1 Aug 2012
Negus J Mani B Scholes C Parker D
Full Access

Medical and allied health staff are beginning to incorporate the Nintendo Wii-Fit into musculoskeletal rehabilitation protocols. One potential application is the assessment of standing balance following Orthopaedic lower limb surgery. The Wii Balance Board (WBB) has been shown to be a valid equivalent to a laboratory grade force platform for the assessment of standing balance. Our objective was to investigate the validity and reliability of the balance tests included with the Wii-Fit software. Initially, a single subject performed multiple repeats of a standing balance test. The data was collected simultaneously from a commercial force platform using its integrated software that measured centre of pressure and from the WBB using the Wii-Fit software that generated a percentage score. The data from each was compared and analyzed, applying the equations of known, validated standing balance measurements. Then, thirty subjects free of lower limb pathology performed a series of standing balance tests combining single leg and double leg stance with their eyes open and then closed. Data was collected from one set of trials on the WBB using the Wii-Fit software and another using bespoke centre of pressure software on a laptop computer. The tests were then repeated on a second occasion within 2 weeks. The algorithm used by the Wii-Fit software to generate the ‘Stillness’ standing balance score was calculated with a predictive value (R squared) of 0.94. This correlated well to a known, valid measure of standing balance. Test-retest reliability was examined for the data from both pieces of software. Both demonstrated good-to-excellent test-retest reliability within ‘software’. The laptop data was transformed using the algorithm and the between ‘software’ reliability was calculated as good-to-excellent. The Wii-Fit software collects standing balance data from the WBB at a fraction of the cost of laboratory grade systems. The score generated by the Wii-Fit software is reliable and valid as an overall assessment of standing balance. Although its application would be limited for detailed assessment of balance disorders, it could still provide surgeons with an affordable, clinic based balance-screening tool. This could form part of an assessment protocol following lower limb surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 70 - 70
1 Aug 2012
Monda M McCarthy I Thornton M Smitham P Goldberg A
Full Access

Introduction. Knowledge of knee kinetics and kinematics contributes to our understanding of the patho-mechanics of knee pathology and rehabilitation and a mobile system for use in the clinic is desirable. We set out to assess validity and reliability of ambulatory Inertial Motion Unit (IMU) Sensors (Pegasus¯) against an established optoelectronic system (CODA¯). Pegasus¯ uses inertial sensors placed on subjects' thighs and lower leg segments to directly measure orientation of these segments with respect to gravity. CODA¯) models the position of joint centres based on tracked positions of optical markers placed on a subject, providing 3D kinematics of the subject's hips, knees and ankles in all three planes. Methods. Intra observer reliability of the Pegasus¯ system was tested on 6 volunteers (4 male; 2 female) with no previous lower limb or knee pathology. IMU's were placed on the long axis of the lateral aspects of both thighs and lower leg segments. A test re-test protocol was used with sagittal data angle collected around a standard circuit. Inter-observer reliability was tested by placement of IMU's by 5 different testers on a single volunteer. To test validity, we collected simultaneous sagittal knee angle data from Pegasus¯ and CODA¯ in two subjects. The presence of IMU's did not compromise positioning of optical markers. Results. Analysis of triplicate measurements showed that intra-observer error is +/− 5°. Inter-observer difference in measurements varied from 3° to 20° absolute values. Positional error of the Pegasus¯ IMU's was significant in comparison to CODA¯, with absolute offsets in knee angles typically of 10° to 25°. Range of motion differences between the two systems calculated as root mean square (rms) difference of the zero meaned signals were 3.8°-4.8°. Conclusion. The Pegasus¯ system is useful in ambulatory measurement of the range of knee motion in the sagittal plane. In the current configuration there was poor intra and inter-observer reliability possibly related to positional error using the Pegasus¯ system and may be due to fixation method, operator factors, body shape and variability of clothing. Recommendations have been made to the manufacturer


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 103 - 103
14 Nov 2024
Dhaliwal J Harris S Logishetty K Brkljač M Cobb J
Full Access

Introduction. The current methods for measuring femoral torsion have limitations, including variability and inaccuracies. Existing 3D methods are not reliable for abnormal femoral anteversion measurement. A new 3D method is needed for accurate measurement and planning of proximal femoral osteotomies. Currently available software for viewing and modelling CT data lacks measurement capabilities. The MSK Hip planner aims to address these limitations by combining measurement, planning, and analysis functionalities into one tool. We aim to answer 5 key questions: Is there a difference between 2D measurement methods? Is there a difference between 3D measurement methods? Is there a difference between 2D and 3D measurement methods? Are any of the measurement methods affected by the presence of osteoarthritis or a CAM deformity?. Method. After segmentation was carried out on 42 femoral CT scans using Osirix, 3D bone models were landmarked in the MSK lab hip planning software. Murphy's, Reikeras’, McBryde, and the novel MSK lab method were used to measure femoral anteversion. Result. Murphy's method had the lowest mean femoral neck anteversion (FNA) at 24.98°, while the MSK method had the highest at 28.55°. Bland-Altman plots showed systematic errors between 2D (1.201°) and 3D (1.074°) methods. All methods demonstrated good intra- and inter-user reliability. Significant differences were found between measurement methods and between patient groups. Conclusion. The MSK Hip Planner software proved useful and convenient to measure FNA. Statistically significant differences in FNA were observed between the measurement methods, as well as between patient groups when split by presence of osteoarthritis and cam deformity. Complex joint pathology and altered femoral morphology should be considered by clinicians when deciding which method to use when measuring FNA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 31 - 31
2 Jan 2024
Ernst M Windolf M Varjas V Gehweiler D Gueorguiev-Rüegg B Richards R
Full Access

In absence of available quantitative measures, the assessment of fracture healing based on clinical examination and X-rays remains a subjective matter. Lacking reliable information on the state of healing, rehabilitation is hardly individualized and mostly follows non evidence-based protocols building on common guidelines and personal experience. Measurement of fracture stiffness has been demonstrated as a valid outcome measure for the maturity of the repair tissue but so far has not found its way to clinical application outside the research space. However, with the recent technological advancements and trends towards digital health care, this seems about to change with new generations of instrumented implants – often unfortunately termed “smart implants” – being developed as medical devices. The AO Fracture Monitor is a novel, active, implantable sensor system designed to provide an objective measure for the assessment of fracture healing progression (1). It consists of an implantable sensor that is attached to conventional locking plates and continuously measures implant load during physiological weight bearing. Data is recorded and processed in real-time on the implant, from where it is wirelessly transmitted to a cloud application via the patient's smartphone. Thus, the system allows for timely, remote and X-ray free provision of feedback upon the mechanical competence of the repair tissue to support therapeutic decision making and individualized aftercare. The device has been developed according to medical device standards and underwent extensive verification and validation, including an in-vivo study in an ovine tibial osteotomy model, that confirmed the device's capability to depict the course of fracture healing as well as its long-term technical performance. Currently a multi-center clinical investigation is underway to demonstrate clinical safety of the novel implant system. Rendering the progression of bone fracture healing assessable, the AO Fracture Monitor carries potential to enhance today's postoperative care of fracture patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 135 - 135
11 Apr 2023
du Moulin W Bourne M Diamond L Konrath J Vertullo C Lloyd D Saxby D
Full Access

Following anterior cruciate ligament reconstruction (ACLR) using a semitendinosus (ST) autograft measures such as length, cross-sectional area, and volume may not fully describe the effects of tendon harvest on muscle morphology as these discrete measures cannot characterize three-dimensional muscle shape. This study aimed to determine between-limb ST shape similarity and regional morphology in individuals with a unilateral history of ACLR using a ST graft, and healthy controls. A secondary analysis of magnetic resonance imaging was undertaken from 18 individuals with unilateral history of ST ACLR and 18 healthy controls. ST muscles were manually segmented, and shape similarity were assessed between limbs and groups using Jaccard index (0-1) and Hausdorff distance (mm). ST length (cm), peak cross-sectional area (CSA) (cm. 2. ), and volume (cm. 3. ) was compared between surgically reconstructed and uninjured contralateral limbs, and between the left and right limbs of control participants with no history of injury. Cohen's d was reported as a measure of effect size. Compared to healthy controls, the ACLR group had significantly (p<0.001, d= −2.33) lower bilateral ST shape similarity. Furthermore, the deviation in muscle shape was significantly (p<0.001, d= 2.12) greater in the ACLR group. Within the ACLR group, maximum Hausdorff distance indicated ST from the ACLR limb deviated (23.1±8.68 mm) from the shape of the healthy contralateral ST, this was observed particularly within the distal region of the muscle. Compared to the uninjured contralateral limb and healthy controls, deficits in peak cross-sectional area and volume in ACLR group were largest in proximal (p<0.001, d= −2.52 to −1.28) and middle (p<0.001, d= −1.81 to −1.04) regions. Findings highlight morphological features in distal ST not identified by traditional discrete morphology measures. ST shape was most different in the distal region of the muscle, despite deficits in CSA and volume being most pronounced in proximal and middle regions. ST shape following ACLR may affect force transmission and distribution within the hamstrings and contribute to persistent deficits in knee flexor and internal rotator strength


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 149 - 149
11 Apr 2023
Gagnier J O'Connor J
Full Access

We sought to determine the relationship between patient preoperative psychological factors and postoperative THA outcomes. We performed an electronic search up to December 2021 using the following terms: “(mental OR psychological OR psychiatric) AND (function OR trait OR state OR predictor OR health) AND (outcome OR success OR recovery OR response) AND total joint arthroplasty)”. Peer-reviewed, English language studies regarding THA outcomes were analyzed for preoperative patient mental health metrics and objective postoperative results regarding pain, functionality and surgical complications. We extracted study data, assessed the risk of bias of included studies, grouped them by outcome measure and performed a GRADE assessment. Seventeen of 702 studies fulfilled inclusion criteria and were included in the review. Overall, compared to cohorts with a normal psychological status, patients with higher objective measures of preoperative depression and anxiety reported increased postoperative pain, decreased functionality and greater complications following THA. Additionally, participants with lower self-efficacy or somatization were found to have worse functional outcomes. Following surgery, both early and late pain scores remained higher in patients with preoperative depression and anxiety. Preoperative depression and anxiety may negatively impact patient reported postoperative pain, physical function and complications following THA. A meta-analysis was not performed because of the heterogeneity of studies, specifically the use of differing pain scales and measures of physical and psychological function as well as varied follow-up times. Future research could test interventions to treat pre-operative depression or anxiety and explore longitudinal outcomes in THA patients. Surgeons should consider the preoperative psychological status when counseling patients regarding expected surgical outcomes and attempt to treat a patient's depression or anxiety prior to undergoing total hip arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 124 - 124
4 Apr 2023
van Knegsel K Hsu C Huang K Benca E Ganse B Pastor T Gueorguiev B Varga P Knobe M
Full Access

The lateral wall thickness (LWT) in trochanteric femoral fractures is a known predictive factor for postoperative fracture stability. Currently, the AO/OTA classification uses a patient non-specific measure to assess the absolute LWT (aLWT) and distinguish stable A1.3 from unstable A2.1 fractures based on a threshold of 20.5 mm. This approach potentially results in interpatient deviations due to different bone morphologies and consequently variations in fracture stability. Therefore, the aim of this study was to explore whether a patient-specific measure for assessment of the relative LWT (rLWT) results in a more precise threshold for prediction of unstable fractures. Part 1 of the study evaluated 146 pelvic radiographs to assess left-right symmetry with regard to caput-collum-angle (CCD) and total trochanteric thickness (TTT), and used the results to establish the rLWT measurement technique. Part 2 reevaluated 202 patients from a previous study cohort to analyze their rLWT versus aLWT for optimization purposes. Findings in Part 1 demonstrated a bilateral symmetry of the femur regarding both CCD and TTT (p ≥ 0.827) allowing to mirror bone's morphology and geometry from the contralateral intact to the fractured femur. Outcomes in Part 2 resulted in an increased accuracy for the new determined rLWT threshold (50.5%) versus the standard 20.5 mm aLWT threshold, with sensitivity of 83.7% versus 82.7% and specificity 81.3% versus 77.8%, respectively. The novel patient-specific rLWT measure can be based on the contralateral femur anatomy and is a more accurate predictor of a secondary lateral wall fracture in comparison to the conventional aLWT. This study established the threshold of 50.5% rLWT as a reference value for prediction of fracture stability and selection of an appropriate implant for fixation of trochanteric femoral fractures


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 20 - 20
11 Apr 2023
Hamilton R Holt C Hamilton D Garcia A Graham C Jones R Shilabeer D Kuiper J Sparkes V Khot S Mason D
Full Access

Mechanical loading of joints with osteoarthritis (OA) results in pain-related functional impairment, altered joint mechanics and physiological nociceptor interactions leading to an experience of pain. However, the current tools to measure this are largely patient reported subjective impressions of a nociceptive impact. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this study, we gathered preliminary data on healthy volunteers to analyse whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus. Following ethical approval, 15 healthy volunteers completed 5 movement and stationary activities in 2 conditions; a control setting and then repeated with an applied quantified thermal pain stimulus to their right knee. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes for skin temperature and conductivity and photoplethysmography (PPG) sensors were manually timestamped to the integrated system. Pilot data showed EMG, GRF and IMU fluctuations within 0.5 seconds of each other in response to a thermal trigger. Preliminary analysis on the 15 participants tested has shown skin conductance, PPG, EMG, GRFs, joint angles and kinematics with varying increases and fluctuations during the thermal condition in comparison to the control condition. Preliminary results suggest physiological and biomechanical data outputs can be linked and identified in response to a defined nociceptive stimulus. Study data is currently founded on healthy volunteers as a proof-of-concept. Further exploratory statistical and sensor readout pattern analysis, alongside early and late-stage OA patient data collection, can provide the information for potential development of wearable nociceptive sensors to measure disease progression and treatment effectiveness