Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 200 - 200
1 Sep 2012
Williams S Isaac G Fisher J
Full Access

INTRODUCTION. Ceramic-on-metal hip replacements (COM, where the head is a Biolox Delta ceramic and liner is Co Cr alloy), have demonstrated reduced wear under standard conditions in vitro compared to metal-on-metal (MOM) [1]. Early clinical results are also encouraging [2]. Recently concerns have been raised regarding the poor clinical performance of MOM hip resurfacings [3], particularly when cups are steeply inclined. Laboratory hip simulator testing has been used to replicate edge loading, also demonstrating elevated wear [4]. Therefore, a range of conditions to replicate sub-optimal use clinically to better predict in vivo performance should be used. The aim of this study was to compare the wear rates of MOM and COM under adverse edge loading conditions in an in vitro hip simulator test. METHODS. Ceramic-on-metal (n=3) and metal-on-metal (n=3) 36mm hip prostheses (supplied by DePuy International Ltd, UK) were tested in the Leeds Physiological Anatomical Hip Joint Simulator. Liners were mounted to provide a clinical angle of 45o, and stems positioned anatomically. A simplified gait cycle and microseparation was applied as previously described [5] for two million cycles in 25% new born calf serum. Gravimetric analysis was completed every million cycles and wear volumes calculated. RESULTS. The overall mean volumetric wear rate of COM bearings was 0.36 ± 0.55mm3 per million cycles, this was significantly less than the MOM bearing wear (1.32 ± 0.91mm3 per million cycles). For both COM and MOM bearings wear under these edge loading conditions was significantly greater if compared to previously reported wear under standard conditions [1]. DISCUSSION. The reduced wear of COM has been attributed to the differential hardness decreasing adhesive wear and reduced corrosive wear [6]. Wear under the harsh edge-loading conditions in this study is also reported to be significantly less in COM bearings compared to MOM. In MOM bearings in edge contact conditions, the wear zone becomes starved of lubrication, this elevates wear and increases damage at the edge of the cup. In COM bearings the harder head does not become damaged when there is lubricant starvation and hence wear does not accelerate in the same way. In conclusion, COM bearings show reduced wear compared to MOM bearings under standard and adverse conditions and there is some early evidence to support this finding clinically. ACKNOWLEDGEMENTS. Supported by DePuy International Ltd. SW is supported by a Royal Academy of Engineering/EPSRC (UK) fellowship


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 229 - 229
1 Sep 2012
Masson B Pandorf T
Full Access

Introduction. In total hip arthroplasty ceramic on ceramic bearing couples are used more and more frequently and on a wordwide basis. The main reason of this choice is reduction of wear debris and osteolysis. The tribological properties and the mechanical behaviour of the implanted ceramic must remain the same throughout the patient's life. The aim of this study was to evaluate the resistance of Alumina Matrix Composite to environmental degradation. Material and method. The alumina matrix composite or BIOLOX ® delta is manufactured in Germany by CeramTec. It is made up of 80 vol.% Al2O3, 17 vol.% Yttria Stabilized ZrO2 and 3vol.% strontium aluminate platelets. The zirconia grains account for 1.3 mol.% of the Yttria content. Accelerated aging tests in water steam at 142°C, 134°C, 121°C, and 105°C were performed to evaluate the aging kinetics of the composite. X-ray diffraction was used to determine the monoclinic phase content on the material surface. Phase transformation is associated with weakness and increase in roughness of zirconia ceramic implants. Results. The data below shows average monoclinic contents before and after aging in water vapour according to the ISO standard test (134°C, 2 bars water steam, 10 h) on the surface and inside the 28 mm taper(12/14 taper) femoral ball heads manufactured in alumina ceramic composite. There are precisions concerning the roughness and the load to failure before and after aging concerning 28mm diameter heads. Before Aging 13%+/-3% of Monoclinic content. After 10 H at 134°C23%+/-3% of Monoclinic content the roughness of the polished surface remain the same (5nm+/− 2). The load to failure of 28 mm heads before aging is 76 kN +/− 5kN, and 72 kN +/− 5kN after aging. The results show that although a rise in monoclinic content is predictable after long aging duration in vivo, the impact of the transformation is quite different to monolithic zirconia. A zirconia femoral head exhibits an important increase of roughness from 2 nm to more than 50 nm when submitted to the same duration of ageing. Other tests with hip simulators under severe micro separation have been done to analyse the impact of aging on wear performance. The main wear zone on femoral heads underwent a phase transformation from tetragonal to monoclinic (23% monoclinic) at 5 milion cycles duration without any change in roughness after 5Mc duration. Conclusion. This experimental testing program has enabled a prediction for the long-term in vivo environmental resistance of prostheses made out of Alumina Matrix Composite. The substantial improvement in mechanical properties and the excellent wear behaviour, even under severe microseparation conditions has been clinically confirmed. Today more than 960,000 ceramic ball heads and more than 450 000 ceramic inserts made of the alumina matrix composite have been implanted. Additionally, due to enhanced mechanical behaviour, new applications in orthopaedics are possible