Advertisement for orthosearch.org.uk
Results 1 - 20 of 108
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 49 - 49
1 Dec 2021
Edwards T Prescott R Stebbins J Wright J Theologis T
Full Access

Abstract. Objectives. Single-event multilevel surgery (SEMLS) is the standard orthopaedic treatment for gait abnormalities in children with diplegic cerebral palsy (CP). The primary aim of this study was to report the long-term functional mobility of these patients after surgery. The secondary aim was to assess the relationship between functional mobility and quality of life (QoL). Methods. Patients were included if they met the following criteria: 1) diplegic CP; 2) Gross Motor Function Classification System (GMFCS) I to III; 3) SEMLS at age ≤ 18. A total of 61 patients, mean age at surgery 11 years eight months (SD 2y 5m), were included. A mean of eight years (SD 3y 10m) after SEMLS, patients were contacted and asked to complete the Functional Mobility Scale (FMS) questionnaire over the telephone and given a weblink to complete an online version of the CP QOL Teen. FMS was recorded for all patients and CP QOL Teen for 23 patients (38%). Results. Of patients graded GMFCS I and II preoperatively, at long-term follow-up the proportion walking independently at home, school/work and in the community was 71% (20/28), 57% (16/28) and 57% (16/28), respectively. Of patients graded GMFCS III preoperatively, at long-term follow-up 82% (27/33) and 76% (25/33) were walking either independently or with an assistive device at home and school/work, respectively, while over community distances 61% (20/33) required a wheelchair. The only significant association between QoL and functional mobility was better ‘feelings about function’ in patients with better home FMS scores (r=0.55; 95% confidence interval 0.15 to 0.79; p=0.01). Conclusion. The majority of children maintained their preoperative level of functional mobility at long-term follow-up after SEMLS. Despite the favourable functional mobility, there was little evidence to establish a link between functional status and quality of life


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 69 - 69
4 Apr 2023
Smeeton M Wilcox R Isaac G Anderson J Board T Van Citters D Williams S
Full Access

Dual mobility (DM) total hip replacements (THRs) were introduced to reduce dislocation risk, which is the most common cause of early revision. Although DM THRs have shown good overall survivorship and low dislocation rates, the mechanisms which describe how these bearings function in-vivo are not fully understood. Therefore, the study aim was to comprehensively assess retrieved DM polyethylene liners for signs of damage using visual inspection and semi-quantitative geometric assessment methods. Retrieved DM liners (n=18) were visually inspected for the presence of surface damage, whereby the internal and external surfaces were independently assigned a score of one (present) or zero (not present) for seven damage modes. The severity of damage was not assessed. The material composition of embedded debris was characterised using energy-dispersive x-ray analysis (EDX). Additionally, each liner was geometrically assessed for signs of wear/deformation [1]. Scratching and pitting were the most common damage modes on either surface. Additionally, burnishing was observed on 50% of the internal surfaces and embedded debris was identified on 67% of the external surfaces. EDX analysis of the debris identified several materials including titanium, cobalt-chrome, iron, and tantalum. Geometric analysis demonstrated highly variable damage patterns across the liners. The incidence of burnishing was three times greater for the internal surfaces, suggesting that this acts as the primary articulation site. The external surfaces sustained more observable damage as evidenced by a higher incidence of embedded debris, abrasion, delamination, and deformation. In conjunction with the highly variable damage patterns observed, these results suggest that DM kinematics are complex and may be influenced by several factors (e.g., soft tissue fibrosis, patient activities) and thus further investigation is warranted


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation. Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01). The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 58 - 58
1 Apr 2018
Hansen C Melgaard D
Full Access

Background. Lack of ability in basic mobility skills is associated with increased mortality in patients with hip fractures. The aim of this study was to identify predictors for performing basic mobility skills at discharge. Methods. From June 2015 to May 2016, 235 consecutive patients (76% female, median age 85 (78–89 IQR)) with hip fractures admitted to the Department of Orthopedic Surgery at North Denmark Regional Hospital were included. Basic mobility was assessed at discharge using the Cumulated Ambulation Score (CAS), which consists of 1) getting in and out of bed, 2) rising from a chair and 3) walking. Possible scores for each task is: unable (CAS=0), supported (CAS=1) or independent (CAS=2). A total score of 6 indicates independence in basic mobility. Inclusion was restricted to first time hip fractures and age ≥65. Exclusion criteria were death during admission or unrecorded CAS at discharge. Results. Before surgery 90.6% were independent in basic mobility (CAS=6). Getting out of bed at discharge: independently 37.5%, supported 56.5% and unable 6.0%. Rising from a chair: independently 49.8%, supported 43% and unable 7.2%. Walking: independently 43.8%, supported 38.3% and unable 17.9%. A total of 79 (33.6%) patients achieved independence in all tasks (CAS=6) at discharge. Independence in: 1) getting in and out of bed, 2) rising from a chair, and 3) walking, respectively had significant association with advanced age, length of stay and Charlson Comorbidity Index >0. Medial fractures were associated with inability to rise from a chair. Advanced age was the only variable significantly associated with each task of CAS. Pre-fracture function was associated with the inability to rise from a chair and walking. Delay of surgery > 48 hours after admission was significantly associated with the inability to walk. Conclusion. Elderly patients with comorbidities and dependent pre-fracture function should receive extra attention in rehabilitation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 1 - 1
17 Nov 2023
Mehta S Goel A Mahajan U Reddy R Bhaskar D
Full Access

Abstract. Introduction. Dislocation post THA confers a higher risk of re-dislocation (Kotwal et al, 2009). The dual mobility (DM) cup design (1974) was aimed at improving the stability by increasing the femoral head to neck ratio (Cuthbert et al., 2019) combining the ideas of low friction arthroplasty with increased jump distance associated with a big head arthroplasty. Aims. Understand the dislocation rates, rates of aseptic loosening, infection rate and revision rates between the 2 types of constructs to provide current and up-to date evidence. Methods. Medline, pubmed, embase and Cochrane databases were used based on PRISMA guidelines. RevMan software was used for the meta-analysis. Studies (English literature) which used DM construct with atleast 6 months follow-up used as intervention and non DM construct as control were included. 2 independent reviewers conducted the review with a third reviewer in case of difference in opinion regarding eligibility. Primary outcome was dislocation rate and secondary outcome was rate of revision. Results. 564 articles identified out of which 44 articles were screened for full texts and eventually 4 systematic review articles found eligible for the study. Thus, study became a review of systematic reviews. From the 4 systematic reviews, another 35 studies were identified for data extraction and 13 papers were used for meta-analysis. Systematic reviews evaluated, projected an average follow up of 6–8 years with significantly lower dislocation rates for DM cups. The total number of patients undergoing DM cup primary THA were 30,559 with an average age 71 years while the control group consisted of 218,834 patients with an average age of 69 years. DM group had lower rate of dislocation (p < 0.00001), total lower rate of cup revision (p < 0.00001, higher incidence of fracture (p>0.05). Conclusion. DM THA is a viable alternative for conventional THA. The long-term results of DM cups in primary THA need to be further evaluated using high quality prospective studies and RCTs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 17 - 17
1 Dec 2021
Shuttleworth M Vickers O Isaac G Culmer P Williams S Kay R
Full Access

Abstract. Objectives. Dual mobility (DM) hip implants whereby the polyethylene liner is “free-floating” are being used increasingly clinically. The motion of the liner is not well understood and this may provide insight into failure mechanisms; however, there are no published methods on tracking liner motion while testing under clinically relevant conditions. The aim was to develop and evaluate a bespoke inertial tracking system for DM implants that could operate submerged in lubricant without line-of-sight and provide 3D orientation information. Methods. Trackers (n=5) adhered to DM liners were evaluated using a robotic arm and a six-degree of freedom anatomical hip simulator. Before each set of testing the onboard sensor suites were calibrated to account for steady-state and non-linearity errors. The trackers were subjected to ranges of motion from ±5° to ±25° and cycle frequencies from 0.35Hz to 1.25Hz and the outputs used to find the absolute error at the peak angle for each principle axis. In total each tracker was evaluated for ten unique motion profiles with each sequence lasting 60 cycles. Results. Across all test conditions the angular error was consistently less than 1.1 ± 1.8° (mean ± SD) per principle axis with no relationship found between range of motion or cycle frequency and measurement error. Rotations about the trackers X and Y axes produced more repeatable results with a maximum spread of 5.5°, where as rotations about Z spread by up to 10.1°. Conclusions. The results of this study show that a system for monitoring DM liner motion without line of sight is possible, going forward this will be used to determine the effects of different loading and kinematic conditions on liner motions in a hip simulator


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 6 - 6
1 Nov 2018
Nuritdinow T Holzschuh J Keppler A Lederer C Boecker W Kammerlander C Daumer M Fuermetz J
Full Access

Capturing objective data of the postoperative changes in the mobility of patients is expected to generate a better understanding of the effect of postoperative treatment. Until recently, the collection of gait-related data was limited to controlled clinical environments. The emergence of accurate wearable accelerometers with sufficient runtime, however, enables the long-term measurement and extraction of mobility parameters, such as “real-world walking speed”. An interim analysis of 1967 hours of actibelt data (3D accelerometer, 100 Hz) from 5 patients (planned total 20) with a femur fracture and 5 patients (planned total 20) with a humerus fracture from a geriatric population at two different sites of the university hospital of the Ludwigs-Maximilian-University in Munich was performed. Mobility data was captured during several days of stationary treatment starting directly after surgery and during a short follow-up visit six weeks after the surgery. Preliminary results show an increase of the mean walking speed between the two visits independent of the type of fracture. Patients with a humerus fracture tended to walk faster than patients with a femur fracture during both visits. The data also reveals an unexpected low level of mobility during the stationary stay. Mobile accelerometry can be used to evaluate different postoperative mobilisation strategies and even provide near-time feedback in geriatric trauma patients


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 70 - 70
1 Nov 2018
Grimm B
Full Access

The relevance of physical activity (PA) for general health and the value of assessing PA in the free-living environment especially for assessing orthopaedic conditions and outcome are discussed. Available methods for assessing PA such as self-reports, trackers, phone apps and clinical grade monitors are introduced. An overview of devices such as accelerometers for research quality assessments is given and aspects for choosing them such as wear location, usability or study population are reviewed. Basic principles to derive mobility parameters from the PA related sensor signals are presented. The symposium explains mobility parameters, their types, definitions, validity, analysis and those with particular relevance to assess orthopaedic conditions. The application of activity monitors is orthopaedic patient studies is demonstrated in various examples such as knee and hop osteoarthritis and total joint arthroplasty, in frail elderly subjects at fall risk or patients with shoulder pathologies


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 4 - 4
1 Jan 2017
Lamontagne M Kowalski E Catelli D Beaulé P
Full Access

Dual mobility (DM) bearing implants reduce the incidence of dislocation following total hip arthroplasty (THA) and as such they are used for the treatment of hip instability in both primary and revision cases. The aim of this study was to compare lower limb muscle activity of patients who underwent a total hip arthroplasty (THA) with a dual mobility (DM) or a common cup (CC) bearing compared to healthy controls (CON) during a sit to stand task. A total of 21 patients (12 DM, 9 CC) and 12 CON were recruited from the local Hospital. The patients who volunteered for the study were randomly assigned to either a DM or a CC cementless THA after receiving informed consent. All surgeries were performed by the same surgeon using the direct anterior approach. Participants underwent electromyography (EMG) and motion analysis while completing a sit-to-stand task. Portable wireless surface EMG probes were placed on the vastus lateralis, rectus femoris, biceps femoris, semitendinosus (ST), gluteus medius and tensor fasciae latae muscles of the affected limb in the surgical groups and the dominant limb in the CON group. Motion capture was used to record lower limb kinematics and kinetics. Muscle strength was recorded using a hand-held dynamometer during maximal voluntary isometric contraction (MVIC) testing. Peak linear envelope (peakLE) and total muscle activity (iEMG) were extrapolated and normalized to the MVIC and time cycle for the sit to stand task. Using iEMG, quadriceps-hamstrings muscle co-activation index was calculated for the task. Nonparametric Kruskal Wallace ANOVA tests and Wilcoxon rank sum tests were used to identify where significant (p < 0.05) differences occurred. The DM group had greater iEMG of the ST muscle compared to the CC (p=0.045) and the CON (p=0.015) groups. The CC group had lower iEMG for hamstring muscles compared to the DM (p=0.041) group. The DM group showed lower quadriceps-hamstrings co-activation index compared to the CON group and it approached significance (p=0.054). The CC group had greater anterior pelvis tilt compared to both DM (p=0.043) and the CON (p=0.047) groups. The DM also had larger knee varus angles and less knee internal rotation compared to both groups, however this never reached significance. No significant differences in muscle strength existed between the groups. Higher ST muscle activity in the DM group is explained by the reduction in internal rotation at the knee joint as the ST muscle was more active to resist the varus forces during the sit-to-stand task. Reduced quadriceps activity in the CC group is explained by increased pelvic anterior tilt as this would shorten the moment arm and muscle length in the quadriceps, ultimately reducing quadriceps muscle activity. The reduced co-activation between quadriceps and hamstrings activity in the DM group compared to the CC and CON groups is related to better hip function and stability. Combining lower co-activation and larger range of motion for the DM group without impingement, this implant seems to offer better prevention against THA subluxation and less wear of the implant


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 18 - 18
1 Mar 2021
Ng G Bankes M Grammatopoulos G Jeffers J Cobb J
Full Access

Abstract

OBJECTIVES

Cam femoroacetabular impingement (FAI – femoral head-neck deformity) and developmental dysplasia of the hip (DDH – insufficient acetabular coverage) constitute a large portion of adverse hip loading and early degeneration. Spinopelvic anatomy may play a role in hip stability thus we examined which anatomical relationships can best predict range of motion (ROM).

METHODS

Twenty-four cadaveric hips with cam FAI or DDH (12:12) were CT imaged and measured for multiple femoral (alpha angles, head-neck offset, neck angles, version), acetabular (centre-edge angle, inclination, version), and spinopelvic features (pelvic incidence). The hips were denuded to the capsule and mounted onto a robotic tester. The robot positioned each hip in multiple flexion angles (Extension, Neutral 0°, Flexion 30°, Flexion 60°, Flexion 90°); and performed internal-external rotations to 5 Nm in each position. Independent t-tests compared the anatomical parameters and ROM between FAI and DDH (CI = 95%). Multiple linear regressions determined which anatomical parameters could predict ROM.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 165 - 165
1 Jul 2014
Acker A Fischer J Aminian K Martin E Jolles B
Full Access

Summary Statment. The dual-mobility cup seems to bring more stability without changing the gait pattern. Introduction. Dislocations and instability are among the worst complications after THA in elderly patient. Dual mobility cups seem to lower these risks. To our knowledge no study performed a gait analysis of dual cup in this group. Methods. Our team implanted 52 dual mobility cups (Gyros, de Puy J&J Corporation) before 2007. 7 hip revisions and 15 primary hips were reviewed in 20 patients. The mean age at the review was 79.8 years old. 15 died or were mentally too disabled to perform a gait analysis. 5 didn't give consent for a clinical study and 8 were not localizable. We performed a gait analysis using a non-invasive miniature sensors device (PhysilogTM) when patients walked freely on a flat ground. We compared our results to a control group of frail eldery patients of the same age who didn't sufferd of orthopedic condition and to a group of patient with a conventional THA from our institution and to the literature. The WOMAC and Harris Hip scores were also computed. Results. None of the 22 hips faced dislocation. The gait analysis showed good results that were superior to those of the control group of frail elderly and comparable to those of conventional THA. The cadence was of 100,3 steps/min, the double stance of 23,3%, the stance of 61,6%, the stride of 1,13 meters and the walking speed of 0,96 m/s. The mean HHS and WOMAC were 87,6 (51–100) and 11,3 (0–34). Conclusion. Our results at 5 years compared favorably with the current litterature. The increase of stability didn't impared the walking performances


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 115 - 115
1 Aug 2012
Papadosifos N Boampong D Weiler R Smitham P Tyler N Holloway C Grange S
Full Access

Introduction

In the US over half a million people are prescribed crutches each year. More than 750,000 wheelchair users exist in the UK and wheelchair and crutch users commonly develop shoulder pathology. The purpose of this study was to determine the influence of complex topographies on heart rate (HR) and thus energy expenditure, using a wheelchair and differing crutch designs on the exertional body stress.

Method

Two Paralympics Athletes from the GB amputee football squad were assessed in a Lomax Active wheelchair and 5 different types of crutches in a randomly allocated order over a course representing everyday complex terrains at the Pedestrian Accessibility and Movement Environment Laboratory (PAMELA), University College London. In addition results were compared over the same course with the athletes using their own personal pair of crutches. The PAMELA course consisted of a mixture of 4% and 2.5% cross falls (transverse) and a simulated road crossing, sprint, slalom and a slow straight.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 98 - 98
4 Apr 2023
Lu V Tennyson M Zhang J Zhou A Thahir A Krkovic M
Full Access

Fragility ankles fractures in the geriatric population are challenging to manage, due to fracture instability, soft tissue compromise, patient co-morbidities. Traditional management options include open reduction internal fixation, or conservative treatment, both of which are fraught with high complication rates. We aimed to present functional outcomes of elderly patients with fragility ankle fractures treated with tibiotalocalcaneal nails. 171 patients received a tibiotalocalcaneal nail over a six-year period, but only twenty met the inclusion criteria of being over sixty and having poor bone stock, verified by radiological evidence of osteopenia or history of fragility fractures. Primary outcome was mortality risk from co-morbidities, according to the Charlson co-morbidity index (CCI), and patients’ post-operative mobility status compared to pre-operative mobility. Secondary outcomes include intra-operative and post-operative complications, six-month mortality rate, time to mobilisation and union. The mean age was 77.82 years old, five of whom are type 2 diabetics. The average CCI was 5.05. Thirteen patients returned to their pre-operative mobility state. Patients with low CCI are more likely to return to pre-operative mobility status (p=0.16; OR=4.00). Average time to bone union and mobilisation were 92.5 days and 7.63 days, respectively. Mean post-operative AOFAS ankle-hindfoot and Olerud-Molander scores were 53.0 (range 17-88) and 50.9 (range 20-85), respectively. There were four cases of broken distal locking screws, and four cases of superficial infection. Patients with high CCI were more likely to acquire superficial infections (p=0.264, OR=3.857). There were no deep infections, periprosthetic fractures, nail breakages, non-unions. TTC nailing is an effective treatment methodology for low-demand geriatric patients with fragility ankle fractures. This technique leads to low complication rates and early mobilisation. It is not a life-changing procedure, with many able to return to their pre-operative mobility status, which is important for preventing the loss of socioeconomic independence


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 13 - 13
1 Dec 2022
Barone A Cofano E Zappia A Natale M Gasparini G Mercurio M Familiari F
Full Access

The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder abduction brace (SAB) after shoulder surgery, revealing that the brace adversely affected gait kinematics with an increase in the risk of falls. The main purpose of the study was to investigate the influence of SAB on gait parameters in patients undergoing shoulder surgery. Patients undergoing elective shoulder surgery (arthroscopic rotator cuff repair, reverse total shoulder arthroplasty, and Latarjet procedure), who used a 15° SAB in the postoperative period, were included. Conversely, patients age > 65 years old, with impaired lower extremity function (e.g., fracture sequelae, dysmorphism, severe osteo-articular pathology), central and peripheral nervous system pathologies, and cardiac/respiratory/vascular insufficiency were excluded. Participants underwent kinematic analysis at four different assessment times: preoperative (T0), 24 hours after surgery (T1), 1 week after surgery (T2), and 1 week after SAB removal (T3). The tests used for kinematic assessment were the Timed Up and Go (TUG) and the 10-meter test (10MWT), both of which examine functional mobility. Agility and balance were assessed by a TUG test (transitions from sitting to standing and vice versa, walking phase, turn-around), while gait (test time, cadence, speed, and pelvic symmetry) was evaluated by the 10MWT. Gait and functional mobility parameters during 10MWT and TUG tests were assessed using the BTS G-Walk sensor (G-Sensor 2). One-way ANOVA for repeated measures was conducted to detect the effects of SAB on gait parameters and functional mobility over time. Statistical analysis was performed with IBM®SPSS statistics software version 23.0 (SPSS Inc., Chicago, IL, USA), with the significant level set at p<0.05. 83% of the participants had surgery on the right upper limb. A main effect of time for the time of execution (duration) (p=0.01, η2=0.148), speed (p<0.01, η2=0.136), cadence (p<0.01, η2=0.129) and propulsion-right (R) (p<0.05, η2=0.105) and left (L) (p<0.01, η2=0.155) in the 10MWT was found. In the 10MWT, the running time at T1 (9.6±1.6s) was found to be significantly longer than at T2 (9.1±1.3s, p<0.05) and at T3 (9.0±1.3s, p=0.02). Cadence at T1 (109.7±10.9steps/min) was significantly lower than at T2 (114.3 ±9.3steps/min, p<0.01) and T3 (114.3±9.3steps/min, p=0.02). Velocity at T1 (1.1±0.31m/s) was significantly lower than at T2 (1.2± 0.21m/s, p<0.05). No difference was found in the pelvis symmetry index. No significant differences were found during the TUG test except for the final rotation phase with T2 value significantly greater than T3 (1.6±0.4s vs 1.4±0.3s, p<0.05). No statistically significant differences were found between T0 and T2 and between T0 and T3 in any of the parameters analyzed. Propulsion-R was significantly higher at T3 than T1 (p<0.01), whereas propulsion-L was significantly lower at T1 than T0 (p<0.05) and significantly higher at T2 and T3 than T1 (p<0.01). Specifically, the final turning phase was significantly higher at T2 than T3 (p<0.01); no significant differences were found for the duration, sit to stand, mid-turning and stand to sit phases. The results demonstrated that the use of the abduction brace affects functional mobility 24 hours after shoulder surgery but no effects were reported at longer term observations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 50 - 50
2 Jan 2024
Teixeira G
Full Access

Back pain is a leading cause of disability worldwide and it is primarily considered to be triggered by intervertebral disc (IVD) degeneration (IVDD). Current treatments may improve pain and mobility, but carry high costs and fail to address IVD repair or regeneration. As no effective therapeutic approach has been proposed to restore inflamed and degenerated IVDs, there is the urgent need to clarify the key pathomechanism of IVDD, the involvement of inflammation, particularly complement activation in matrix catabolism, and how to target them towards tissue repair/regeneration. Mesenchymal stem cell (MSC)-based therapies have become the focus of several regenerative IVD studies. Although patients in clinical trials reported less pain after cell therapy, the long-term success of cell engraftment is unclear due to the hostile IVD environment. The mechanism-of-action of MSCs is mostly dependent on the secreted soluble factors. Moreover, priming of MSC with interleukin (IL)-1β modulates the secretome content, improving its anti-inflammatory and regenerative effect on IVDD organ culture models. MSC-derived extracellular vesicles (EVs) have also been shown to modulate human IVD cells towards a healthy IVD phenotype in vitro. However, the mechanisms involved in the effect of secretome and EVs, particularly with regard to immunomodulation and matrix metabolism, are not fully understood. Our work investigates the effects of secretome and EVs secreted by IL-1β-primed MSCs to impair IVD matrix degradation and/or improve matrix formation in IVDD


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 107 - 107
4 Apr 2023
Li C Ding Y Li S Lin S Wen Z Ouyang Z
Full Access

Osteoarthritis, the most common degenerative joint disease, significantly impairs life quality and labor capability of patients. Synovial inflammation, initiated by HMGB1 (High mobility group box 1)-induced activation of macrophage, precedes other pathological changes. As an upstream regulator of NF-κB (nuclear factor-kappa B) and MAPK (mitogen-activated protein kinase) signaling pathway, TAK1 (TGF-β activated kinase 1) participates in macrophage activation, while its function in osteoarthritis remains unveiled. This study aims to investigate the role of TAK1 in the pathogenesis of osteoarthritis via both in vitro and in vivo approaches. We performed immunohistochemical staining for TAK1 in synovial tissue, both in osteoarthritis patients and healthy control. Besides, immunofluorescence staining for F4/80 as macrophage marker and TAK1 were conducted as well. TAK1 expression was examined in RAW264.7 macrophages stimulated by HMGB1 via qPCR (Quantitative polymerase chain reaction) and Western blotting, and the effect of TAK1 inhibitor (5z-7 oxozeaenol) on TNF-α production was evaluated by immunofluorescence staining. Further, we explored the influence of intra-articular shRNA (short hairpin RNA) targeting TAK1 on collagenase-induced osteoarthritis in mice. Immunohistochemical staining confirmed significant elevation of TAK1 in osteoarthritic synovium, and immunofluorescence staining suggested macrophages as predominant residence of TAK1. In HMGB1-stimulated RAW264.7 macrophages, TAK1 expression was up-regulated both in mRNA and protein level. Besides, TAK1 inhibitor significantly impairs the production of TNF-α by macrophages upon HMGB1 stimulation. Moreover, intra-articular injection of lentivirus loaded with shRNA targeting TAK1 (sh-TAK1) reduced peri-articular osteophyte formation in collagenase-induced osteoarthritis in mice. TAK1 exerts a potent role in the pathogenesis of osteoarthritis by mediating the activation of macrophages


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 69 - 69
11 Apr 2023
Domingues I Cunha R Domingues L Silva E Carvalho S Lavareda G Bispo C
Full Access

Radial head fractures are among the most common fractures around the elbow. Radial head arthroplasty is one of the surgical treatment options after complex radial head fractures. This surgery is usually done under general anaesthesia. However, there is a recent anaesthetic technique - wide awake local anaesthesia no tourniquet (WALANT) - that has proven useful in different surgical settings, such as in distal radius or olecranon fractures. It allows a good haemostatic control without the use of a tourniquet and allows the patient to actively collaborate during the surgical procedure. Furthermore, there are no side effects or complications caused by the general anaesthesia and there's an earlier patient discharge. The authors present the case of a seventy-six-year-old woman who presented to the emergency department after a fall from standing height with direct trauma to the left elbow. The radiological examination revealed a complete intra-articular comminuted fracture of the radial head (Mason III). Clinical management: The patient was submitted to surgery with radial head arthroplasty, using WALANT. The surgery was successfully completed without pain. There were no intra or immediate post-operative complications and the patient was discharged on the same day. Six weeks after surgery, the patient had almost full range of motion and was very pleased with the functional outcome, with no limitations on her activities of daily living. The use of WALANT has been expanded beyond the hand and wrist surgery. It is a safe and simple option for patients at high risk of general anaesthesia, allowing similar surgical outcomes without the intraoperative and postoperative complications of general anaesthesia and permitting an earlier hospital discharge. Furthermore, it allows the patient to actively collaborate during the surgery, providing the surgeons the opportunity to evaluate active mobility and stability, permitting final corrections before closing the incision


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 45 - 45
2 Jan 2024
Gilsing R Hoogeveen M Boers H van der Weegen W
Full Access

Knee swelling is common after injury or surgery, resulting in pain, restricted range of movement and limited mobility. Accurately measuring knee swelling is critical to assess recovery. However, current measurement methods are either unreliable or expensive [1,2]. Therefore, a new measurement method is developed. This wearable (the ‘smart brace’) has shown the ability to distinguish a swollen knee from a not swollen knee using multi-frequency-bio impedance analysis (MF-BIA) [3]. This study aimed to determine the accuracy of this smart brace. The study involved 25 usable measurements on patients treated for unilateral knee osteoartritis with a 5mL injection of Lidocaïne + DepoMedrol (1:4). MF-BIA measurements were taken before and after the injection, both on the treated and untreated knee. The smart brace accurately measured the effect of the injection by a decrease in resistance of up to 2.6% at 100kHz (p<0.01), where commonly used gel electrodes were unable to measure the relative difference. Remarkably, both the smart brace and gel electrodes showed a time component in the MF-BIA measurements. To further investigate this time component, 10 participants were asked to lie down for 30 minutes, with measurements taken every 3 minutes using both gel electrodes and the smart brace on both legs. The relative change between each time step was calculated to determine changes over time. The results showed presence of a physiological aspect (settling of knee fluids), and for the brace also a mechanical aspect (skin-electrode interface) [4]. The mechanical aspect mainly interfered with reactance values. Overall, the smart brace is a feasible method for quantitatively measuring knee swelling as a relative change over time. However, the skin-electrode interface should be improved for reliable measurements at different moments in time. The findings suggest that the smart brace could be a promising tool for monitoring knee swelling during rehabilitation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 18 - 18
2 Jan 2024
Ferreira S Tallia F Heyraud A Walker S Salzlechner C Jones J Rankin S
Full Access

For chondral damage in younger patients, surgical best practice is microfracture, which involves drilling into the bone to liberate the bone marrow. This leads to a mechanically inferior fibrocartilage formed over the defect as opposed to the desired hyaline cartilage that properly withstands joint loading. While some devices have been developed to aid microfracture and enable its use in larger defects, fibrocartilage is still produced and there is no clear clinical improvement over microfracture alone in the long term. Our goal is to develop 3D printed devices, which surgeons can implant with a minimally invasive technique. The scaffolds should match the functional properties of cartilage and expose endogenous marrow cells to suitable mechanobiological stimuli in-situ, in order to promote healing of articular cartilage lesions before they progress to osteoarthritis, and rapidly restore joint health and mobility. Importantly, scaffolds should direct a physiological host reaction, instead of a foreign body reaction, associated with chronic inflammation and fibrous capsule formation, negatively influencing the regenerative outcome. Our novel silica/polytetrahydrofuran/polycaprolactone hybrids were prepared by sol-gel synthesis and scaffolds were 3D printed by direct ink writing. 3D printed hybrid scaffolds with pore channels of ~250 µm mimic the compressive behaviour of cartilage. Our results show that these scaffolds support human bone marrow stem/stromal cell (hMSC) differentiation towards chondrogenesis in vitro under hypoxic conditions to produce markers integral to articular cartilage-like matrix evaluated by immunostaining and gene expression analysis. Macroscopic and microscopic evaluation of subcutaneously implanted scaffolds in mice showed that scaffolds caused a minimal resolving inflammatory response. Our findings show that 3D printed hybrid scaffolds have the potential to support cartilage regeneration. Acknowledgements: Authors acknowledge funding provided by EPSRC grant EP/N025059/1


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 103 - 103
2 Jan 2024
Cardona-Timoner M Bessa-Gonçalves M Nogueira F Barbosa M Santos S
Full Access

Bone defects and fractures, caused by injury, trauma or tumour resection require hospital treatment and temporary loss of mobility, representing an important burden for societies and health systems worldwide. Autografts are the gold standard for promoting new bone formation, but these may provide insufficient material and lead to donor site morbidity and pain. We previously showed that Fibrinogen (Fg) scaffolds promote bone regeneration in vivo (1), and that modifying them with 10mM of Magnesium (Mg) ions modulates macrophage response in vitro and in vivo (2). Also, we showed that Extracellular Vesicles (EV) secreted by Dendritic Cells (DC) recruit Mesenchymal Stem/Stromal Cells (MSC)(3). Herein, we aim to functionalize FgMg scaffolds with DC-EV, to promote recruitment and osteogenic differentiation of MSC. Scaffolds were produced by freeze-drying (2). Ethical permission was sought for all studies. Primary human peripheral blood monocyte-derived DC were cultured, their secreted EV were isolated by differential (ultra)-centrifugation and characterised by transmission electron microscopy and nanoparticle tracking analysis (3). Bone marrow MSC were used to determine the impact of EV-functionalized scaffolds through migration assays and their osteogenic differentiation was assessed by Alizarin Red staining. Fg and FgMg scaffolds functionalized with EV were characterized. Fg and FgMg scaffolds functionalized with DC-secreted EV were more efficient at recruiting MSC than scaffolds alone. MSC cultured on FgMg scaffolds showed significantly increased calcium deposits, in comparison with those cultured on Fg scaffolds. Fg scaffold modification by Mg promotes MSC osteogenic differentiation, while their functionalization with DC-secreted EV acts to promote MSC recruitment. This renders the FgMg-EV functionalized scaffolds an attractive material to promote new bone formation. Acknowledgments: Work funded by Orthoregeneration Network (ON Pilot Grant Spine 2021, EVS4Fusion). MCT supported by ERASMUS+ program