Aim: The aim of this prospective study was to analyse the rate of sinking and the clinical results of the new cementless
Purpose. The purpose of this study was to evaluate the results of
We evaluated a large database with mechanical failure of a single uncemented modular femoral component, used in revision hip arthroplasty, as the end point and compared them to a control group treated with the same implant. Patient- and implant-specific risk factors for implant failure were analyzed. All cases of a fractured uncemented modular revision femoral component from one manufacturer until April 2017 were identified and the total number of implants sold until April 2017 was used to calculate the fracture rate. The manufacturer provided data on patient demographics, time to failure, and implant details for all notified fractured devices. Patient- and implant-specific risk factors were evaluated using a logistic regression model with multiple imputations and compared to data from a previously published reference group, where no fractures had been observed. The results of a retrieval analysis of the fractured implants, performed by the manufacturer, were available for evaluation.Aims
Methods
Although good clinical outcomes have been reported for monolithic tapered, fluted, titanium stems (TFTS), early results showed high rates of subsidence. Advances in stem design may mitigate these concerns. This study reports on the use of a current monolithic TFTS for a variety of indications. A multi-institutional retrospective study of all consecutive total hip arthroplasty (THA) and revision total hip arthroplasty (rTHA) patients who received the monolithic TFTS was conducted. Surgery was performed by eight fellowship-trained arthroplasty surgeons at four institutions. A total of 157 hips in 153 patients at a mean follow-up of 11.6 months (SD7.8) were included. Mean patient age at the time of surgery was 67.4 years (SD 13.3) and mean body mass index (BMI) was 28.9 kg/m2 (SD 6.5). Outcomes included intraoperative complications, one-year all-cause re-revisions, and subsidence at postoperative time intervals (two weeks, six weeks, six months, nine months, and one year).Aims
Methods
We report our experience of revision total hip
replacement (THR) using the Revitan curved modular titanium fluted revision
stem in patients with a full spectrum of proximal femoral defects.
A total of 112 patients (116 revisions) with a mean age of 73.4
years (39 to 90) were included in the study. The mean follow-up
was 7.5 years (5.3 to 9.1). A total of 12 patients (12 hips) died
but their data were included in the survival analysis, and four
patients (4 hips) were lost to follow-up. The clinical outcome,
proximal bone regeneration and subsidence were assessed for 101
hips. The mean Harris Hip Score was 88.2 (45.8 to 100) after five years
and there was an increase of the mean Barnett and Nordin-Score,
a measure of the proximal bone regeneration, of 20.8 (-3.1 to 52.7).
Five stems had to be revised (4.3%), three (2.9%) showed subsidence,
five (4.3%) a dislocation and two of 85 aseptic revisions (2.3%)
a periprosthetic infection. At the latest follow-up, the survival with revision of the stem
as the endpoint was 95.7% (95% confidence interval 91.9% to 99.4%)
and with aseptic loosening as the endpoint, was 100%. Peri-prosthetic
fractures were not observed. We report excellent results with respect to subsidence, the risk
of fracture, and loosening after femoral revision using a modular
curved revision stem with distal cone-in-cone fixation. A successful
outcome depends on careful pre-operative planning and the use of
a transfemoral approach when the anatomy is distorted or a fracture
is imminent, or residual cement or a partially-secured existing
stem cannot be removed. The shortest appropriate stem should, in
our opinion, be used and secured with >
3 cm fixation at the femoral
isthmus, and distal interlocking screws should be used for additional
stability when this goal cannot be realised. Cite this article:
We report the results of a cementless modular revision component which has been used in our hospital since 1993. There were 103 patients, in which the aforementioned cementless femoral revision component was used. Patients were evaluated, using both a modiþed HHS and serial radiographs performed preoperatively, at 2 weeks, 3 months and annually postoperatively. The patients were followed for a minimum of 4 years. Pre-operatively, bony defects were classiþed on radiographs according to the classiþcation of Mallory. Three hips were excluded from the evaluation: 1 was lost to follow-up and 2 were deceased. 100 hips with an average follow-up of 75 months were retrospectively reviewed. Indication for revision was aseptic loosening in 96 cases and infection in 4. Average number of previous hip surgeries in this patient group was 2.3. Average pre-operative hip score was 48,8 compared to an average postoperative hip score of 74,4. Postoperative complications included 2 infections and 2 cases of DVT with occurrence of PE in 1 case, 4 postoperative dislocations, 2 cases with radiographic subsidence of the femoral component and 1 case with sciatic nerve lesion. Intraoperative complications included femoral fractures upon dislocation of the hip or impaction of the new stem in 37 cases. At time of latest review there were no clinical or radiographic signs of component loosening. The incidence of postoperative and intraoperative complications are comparable to the literature. Clinical and radiographic results of the cementless, modular titanium revision component are promising and support its continued use.
Aims. There are limited long-term studies reporting on outcomes of the Zimmer
Implant fracture of
Aims. The risk of mechanical failure of
Modern
In recent years, the direct anterior approach (DAA) has become a standard approach for primary total hip arthroplasty (THA). With the increasing use of the DAA in primary cases also more and more revision surgeries are performed through the same interval. With ability to extend the DAA interval proximally and distally, loose cups, loose stems, and even periprosthetic femoral fractures (PPF) can be treated. Especially, PPF are devastating complications causing functional limitations and increased mortality. Therefore, we conducted a study to report the outcome of surgical treatment of PPF with the DAA interval. We report on the one year complications and mortality in 40 cases with a mean clinical follow-up of 1.5 years. Mean age of patients was 74.3 years. Fractures were classified as Vancouver B2 (36), and B3 (N=4). In 14 cases, a standard stem was used, and in 26 cases a
Bone Loss is the main problem in failed total hip arthroplasties. Revision surgery must be conformed to the degree of the bone loss. Since 1986, 330 cases of failed THA underwent to revision surgery. Different solutions were adopted according to Paprosky femoral defects classification. In type I, a primary cementless stem was implanted (23%). In type II and IIIa, were proximal fixation is still possible to achieve, Mid PCA-Howmedica (5%) and
The most important advantage of
Introduction. The success of cementless total hip arthroplasty (THA), primary as well as for revision, largely depends on the initial stability of the femoral implant. In this respect, several studies have estimated that the micromotion at the bone-implant interface should not exceed 150µm (Jasty 1997, Viceconti 2000) in order to ensure optimal bonding between bone and implant. Therefore, evaluating the initial stability through micromotion measurements serves as a valid method towards reviewing implant design and its potential for uncemented THAs. In general, the methods used to measure the micromotion assume that the implant behaves as a rigid body. While this could be valid for some primary stems (Østbyhaug 2010), studies that support the same assumption related to revision implants were not found. The aim of this study is to assess the initial stability of a femoral revision stem, taking into account possible non-rigid behaviour of the implant. A new in vitro measuring method to determine the micromotion of femoral revision implants is presented. Both implant and bone induced displacements under cyclic load are measured locally. Methods. A Profemur R
Aims. To evaluate the hypothesis that failed osteosynthesis of periprosthetic
Vancouver type B1 fractures can be treated successfully with stem
revision using a transfemoral approach and a cementless,
The use of monoblock tapered stems has shown very good results in hip revision surgery, particularly in case of severe proximal femur bone deficiency. However a too valgus neck, a short offset, may result in a high risk of dislocation. In addiction monoblock stems make the control of limb length difficult, and potentially increase the risk of subsidence or intraoperative fracture. Different types of modular tapered stems with distal fixation have been developed to allow a more user-friendly restoration of limb-lenght discrepancy and an indipendent proximal control of offset and anti-retroversion. We assessed 64 hip revisions performed on 63 patients (mean age 62 years). Indication for treatment was: aseptic loosening (42 cases) septic loosening (18 cases) and periprosthetic fracture (4 cases). According to Paprosky classification, femoral defects were staged as type I (2 cases), type II (20 cases), type IIIA (25 cases) and type IIIB (13 cases); periprosthetic fractures were all type B2 according to the Vancouver classification. In all cases we used a Restoration® Modular (Striker, Orthopaedics) cone-conical uncemented stem implanted by a lateral approach, with a trans-femoral osteotomy in 19 cases. A preventive cerclage cable was used in 10 patients in case of very thin cortex. We used the minimum size stem in most of the cases. Mean follow-up was 20 months (range 6–36). Short-term complications included hip dislocation (1 case), recurrent infection (1 case), stem subsidence >
5 mm (1 case). Mean Harris Hip Score improved from 43 to 81.9 (t test p<
0.0005), while limb lenght discrepancy improved in 97% of cases with symmetry in 76%. The use of
One-stage exchange for periprosthetic joint infection (PJI) in total hip arthroplasty (THA) is gaining popularity. The outcome for a repeat one-stage revision THA after a failed one-stage exchange for infection remains unknown. The aim of this study was to report the infection-free and all-cause revision-free survival of repeat one-stage exchange, and to investigate the association between the Musculoskeletal Infection Society (MSIS) staging system and further infection-related failure. We retrospectively reviewed all repeat one-stage revision THAs performed after failed one-stage exchange THA for infection between January 2008 and December 2016. The final cohort included 32 patients. The mean follow-up after repeat one-stage exchange was 5.3 years (1.2 to 13.0). The patients with a further infection-related failure and/or all-cause revision were reported, and Kaplan-Meier survival for these endpoints determined. Patients were categorized according to the MSIS system, and its association with further infection was analyzed.Aims
Methods
Tapered fluted titanium stems are increasingly
used for femoral revision arthroplasty. They are available in modular and
non-modular forms. Modularity has advantages when the bone loss
is severe, the proximal femur is mis shapen or the surgeon is unfamiliar
with the implant, but it introduces the risk of fracture of the
stem at the junction between it and the proximal body segment. For
that reason, and while awaiting intermediate-term results of more recently
introduced designs of this junction, non-modularity has attracted
attention, at least for straightforward revision cases. We review the risks and causes of fracture of tapered titanium
modular revision stems and present an argument in favour of the
more selective use of modular designs. Cite this article:
The use of plate-and-cable constructs to treat periprosthetic fractures around a well-fixed femoral component in total hip replacements has been reported to have high rates of failure. Our aim was to evaluate the results of a surgical treatment algorithm to use these lateral constructs reliably in Vancouver type-B1 and type-C fractures. The joint was dislocated and the stability of the femoral component was meticulously evaluated in 45 type-B1 fractures. This led to the identification of nine (20%) unstable components. The fracture was considered to be suitable for single plate-and-cable fixation by a direct reduction technique if the integrity of the medial cortex could be restored. Union was achieved in 29 of 30 fractures (97%) at a mean of 6.4 months (3 to 30) in 29 type-B1 and five type-C fractures. Three patients developed an infection and one construct failed. Using this algorithm plate-and-cable constructs can be used safely, but indirect reduction with minimal soft-tissue damage could lead to shorter times to union and lower rates of complications.
Iontophoresis is a novel technique which may be used to facilitate the movement of antibiotics into the substance of bone using an electrical potential applied externally. We have examined the rate of early infection in allografts following application of this technique in clinical practice. A total of 31 patients undergoing revision arthroplasty or surgery for limb salvage received 34 iontophoresed sequential allografts, of which 26 survived for a minimum of two years. The mean serum antibiotic levels after operation were low (gentamicin 0.37 mg/l (0.2 to 0.5); flucloxacillin 1 mg/l (0 to 1) and the levels in the drains were high (gentamicin 40 mg/l (2.5 to 131); flucloxacillin 17 mg/l (1 to 43). There were no early deep infections. Two late infections were presumed to be haemotogenous; 28 of the 34 allografts were retained. In 12 patients with pre-existing proven infection further infection has not occurred at a mean follow-up of 51 months (24 to 82).