Vol. 107-B, Issue 2 | Pages 239 - 245
1 Feb 2025
Evenhuis RE Bus MPA van Nes J Walter SG Cabrolier J Fiocco M van der Wal RJP Broekhuis D Sellevold S van de Sande MAJ

Aims

Over time, the locking mechanism of Modular Universal Tumour and Revision System (MUTARS) knee arthroplasties changed from polyethylene (PE) to polyether-ether-ketone Optima (PEEK) and metal-on-metal (MoM) in an attempt to reduce the risk of mechanical failure. In this study, we aimed to assess the cumulative incidence of locking mechanism revision for symptomatic instability by type of material, and assess potential associated risk factors.

Methods

The MUTARS Orthopaedic Registry Europe was used for a retrospective review of 316 patients (54% male (n = 170), median age 44 years (IQR 23 to 61)) who underwent a MUTARS knee arthroplasty for oncological indications between December 1995 and January 2023. The minimum follow-up was 12 months, and the median follow-up was 7.9 years (IQR 3.3 to 13.0). A competing risk model was used to estimate the cumulative incidence of first locking mechanism revision with death and revision for any other reason as competing events. Possible risk factors were assessed employing a univariate cause-specific hazards regression model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XIV | Pages 34 - 34
1 Apr 2012
Lehner B Depeweg D Egermann M Raiss P
Full Access

Aim. The aim of this study was to analyze our results using a modular endoprosthetic replacement system (MUTARS) for bone tumours of the proximal humerus. Methods. Thirty-nine patients were treated with a MUTARS endoprosthesis of the proximal humerus. Mean follow-up was 38 months (3-138 months). Most operations were necessitated by metastasis (n=30); surgery for a primary tumour (n=9) was less frequent. The Enneking score and the active ranges of motion for shoulder flexion, abduction, and external rotation were recorded. Complete refixation of the rotator cuff was possible in 23 cases. Radiographs also were obtained. Results. Patient survival was 77% at 2 years and 45% at 11.5 years after surgery. The survival rate of the limb was 90% at 11.5 years. The mean Enneking score was 19 points (range 7-27 points). The mean shoulder flexion was 34 degrees (range 0-90 degrees), abduction 33 degrees (range 0-90 degrees), and external rotation 12 degrees (range 10-50 degrees). Patients with a complete rotator cuff repair showed a significant better range of motion compared to patients with a partial or no repair (p<0.015). No signs of implant loosening were observed on postoperative radiographs. Seven complications occurred, five of them leading to implant revision. At 11.5 years after surgery, the survival rate for the whole cohort without complications was 72%, without revision of the implant 70%. Conclusion. Replacement of the proximal humerus with MUTARS endoprosthesis is a viable treatment option for bone tumours with satisfying results