Background. In recent years, ‘Get It Right First Time (GIRFT)’ have advocated cemented replacements in femoral part of Total hip arthroplasty (THA) especially in older patients. However, many studies were unable to show any difference in outcomes and although cemented prostheses may be associated with better short-term pain outcomes there is no clear advantage in the longer term. It is not clear when and why to do cemented instead of cementless. Aim. To assess differences in patient reported outcomes in uncemented THAs based on patient demographics in order to decide when cementless THA can be done safely. Method. Prospective data collection of consecutive 1079 uncemented THAs performed for 954 patients in single trust between 2010 and 2020. Oxford Hip Score (OHS) and complications were analysed against demographic variables (age, sex, BMI, ASA) and prosthesis features (femoral and acetabular size, offset and acetabular screws). Results. The mean pre-operative
Increased collection of patient-reported outcome measures (PROM) in registries enables international comparison of patient-centered outcomes after knee and hip replacement. We aimed to investigate 1) variations in PROM improvement, 2) the possible confounding factor of BMI, and 3) differences in comorbidity distributions between registries. Registries affiliated with the International Society of Arthroplasty Registries (ISAR) or OECD membership countries were invited to report aggregate EQ-5D, OKS,
Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the
Management of acetabular fractures in the elderly population remains somewhat controversial in regards to when to consider is open reduction internal fixation (ORIF) versus acute primary total hip. study aims to (1) describe outcome of this complex problem and investigate predictors of successful outcome. This retrospective study analyzes all acetabular fractures in patients over the age of 60, managed by ORIF at a tertiary trauma care centre between 2007 and 2018 with a minimum follow up of one year. Of the 117 patients reviewed, 85 patients undergoing ORIF for treatment of their acetabular fracture were included in the analysis. The remainder were excluded based management option including acute ORIF with THA (n=10), two-stage ORIF (n=2), external fixator only (n=1), acute THA (n=1), and conservative management (n=1). The remainder were excluded based on inaccessible medical records (n=6), mislabelled diagnosis (n=6), associated femoral injuries (n=4), acetabular fracture following hemiarthroplasty (n=1). The mean age of the cohort is 70±7 years old with 74% (n=62) of patients being male. Data collected included: demographics, mechanism of injury, Charlson Comorbidity Index (CCI), ASA Grade, smoking status and reoperations. Pre-Operative Radiographs were analyzed to determine the Judet and Letournel fracture pattern, presence of comminution and posterior wall marginal impaction. Postoperative radiographs were used to determine Matta Grade of Reduction. Outcome measures included morbidity-, mortality- rates, joint survival, radiographic evidence of osteoarthritis and patient reported outcome measures (PROMs) using the Oxford Hip Score (OHS) at follow-up. A poor outcome in ORIF was defined as one of the following: 1) conversion to THA or 2) the presence of radiographic OA, combined with an
Introduction. Management of Vancouver type B1 and C periprosthetic fractures in elderly patients requires fixation and an aim for early mobilisation but many techniques restrict weightbearing due to re-fracture risk. We present the clinical and radiographic outcomes of our technique of total femoral plating (TFP) to allow early weightbearing whilst reducing risk of re-fracture. Methods. A single-centre retrospective cohort study was performed including twenty-two patients treated with TFP for fracture around either hip or knee replacements between May 2014 and December 2017. Follow-up data was compared at 6, 12 and 24 months. Primary outcomes were functional scores (Oxford Hip or Knee score (OHS/OKS)), Quality of Life (EQ-5D) and satisfaction at final follow-up (Visual Analogue Score (VAS)). Secondary outcomes were radiographic fracture union and complications. Results. Mean
Hip resurfacing arthroplasty (HRA) is a bone conserving alternative to total hip arthroplasty. We present the early 1 and 2-year clinical and radiographical follow-up of a novel ceramic-on-ceramic (CoC) HRA in a multi-centric Australian cohort. Patient undergoing HRA between September 2018 and April 2021 were prospectively included. Patient-reported outcome measures (PROMS) in the form of the Forgotten Joint Score (FJS), HOOS Jr, WOMAC, Oxford Hip Score (OHS) and UCLA Activity Score were collected preoperatively and at 1- and 2-years post-operation. Serial radiographs were assessed for migration, component alignment, evidence of osteolysis/loosening and heterotopic ossification formation. 209 patients were identified of which 106 reached 2-year follow-up. Of these, 187 completed PROMS at 1 year and 90 at 2 years. There was significant improvement in HOOS (p< 0.001) and
The prevalence of gluteal tendinopathy (GT) associated with osteoarthritis of the hip is difficult to determine as it is frequently undiagnosed or misdiagnosed as trochanteric bursitis. Its relationship to total hip arthroplasty (THA) outcomes is currently unknown. The aim of this study was to determine the incidence of GT at the time of hip arthroplasty and examine the relationship between GT and patient reported outcomes (PROMS) before and after THA. Patients undergoing THA for primary osteoarthritis between August 2017 and August 2020 were recruited. Tendinopathy was assessed and graded at time of surgery. PROMS included the Oxford Hip Score (OHS), HOOS JR, EQ-5D, and were collected preoperatively and at one year after THA. Satisfaction with surgery was also assessed at 1 year. 797 patients met eligibility criteria and were graded as Grade 1: normal tendons (n =496, 62%), Grade 2: gluteal tendinopathy but no tear (n=222, 28%), Grade 3: partial/full thickness tears or bare trochanter (n=79, 10%). Patients with abnormal gluteal tendons were older (p=0.001), had a higher mean BMI (p=0.01), and were predominately female (p=0.001). Patients with higher grade tendinopathy had statistically significant inferior PROMS at one year,
Objectives. Acetabular fractures with quadrilateral plate involvement have been shown to have a high rate of complications. Anatomic suprapectineal plating systems have been developed to manage these injuries with good short-term outcomes, however long-term maintenance of anatomical reduction and functional outcomes is yet to be established. Efficacy of maintenance of reduction and functional outcomes at a minimum of 5-years follow-up is the aim of this study. Design and Methods. A retrospective cohort study examining patients aged over 16 years following fixation of acetabular fractures with quadrilateral plate involvement at a trauma centre in the United Kingdom. All patients had acetabular fracture fixation with an anatomically designed suprapectineal plate. Patients were admitted from March 2014 to January 2017. Primary outcomes included objective radiological outcomes such as reduction quality, maintenance of reduction, metalwork failure, complications (such as reoperation, neurological deficit and mortality) and subjective patient-related outcome measures (PROMs) using the Oxford Hip Score and EuroQol EQ5D Score at a minimum of 5-years post-operatively. Results. 16 patients met our eligibility criteria in this cohort. Post-operative mean Oxford Hip Score (OHS) at a minimum of 5-years was 40.5 (SD 11.9) with a median score of 45. Post-operative mean EuroQol EQ-5D scores at a minimum of 5-years were 0.83 (SD 0.25). Comparison of
A large proportion of wait times for primary total knee (TKA) and hip (THA) arthroplasty is the time from primary care referral to surgical consultation. To our knowledge, no study has investigated whether a referral Oxford Knee or Hip Score (OKHS) could be used to triage non-surgical referrals appropriately. The primary purpose of the current study was to determine if a referral OKHS has the predictive ability to discriminate when a knee or hip referral will be deemed conservative as compared to surgical by the surgeon during their first consultation, and to identify an OKHS cut-off point that accurately predicts when a primary TKA or THA referral will be deemed conservative. We retrospectively reviewed all consecutive primary TKA and THA consultations from a single surgeon's tertiary, high volume practice over a three-year period. Patients with a pre-consultation OKHS, BMI < 4 1, and no absolute contraindication to TJR were included. Consultation knees/hips were categorized into two groups based on surgeon's decision, those that were offered TJR during their first consolation (surgical) versus those that were not (conservative). Baseline demographic data and OKHS were abstracted. Variables of interest were compared between cohorts using the exact chi-square test and Wilcoxon rank-sum test. Spearman's rank correlation coefficients were used to measure association between pre-consult OKHS and the surgeon's decision. A receiver operator characteristic (ROC) curve analysis was used to calculate the area under the curve (AUC) and to identify a cut-off point for the pre-operative OKHS that identified whether or not a referral was deemed conservative. TKA and THA referrals were analyzed separately. The study included 1,436 knees (1,016 patients) with a median OKS of 25 (IQR 19–32) and 478 hips (388 patients) with a median
Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration. Prospective follow-up of the Duplex. TM. implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website. 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in
Adverse spinopelvic characteristics (ASC) have been associated with increased dislocation risk following primary total hip arthroplasty (THA). A stiff lumbar spine, a large posterior standing tilt when standing and severe sagittal spinal deformity have been identified as key risk factors for instability. It has been reported that the rate of dislocation in patients with such ASC may be increased and some authors have recommended the use of dual mobility bearings or robotics to reduce instability to within acceptable rates (<2%). The aims of the prospective study were to 1: Describe the true incidence of ASC in patients presenting for a THA 2. Assess whether such characteristics are associated with greater symptoms pre-THA due to the concomitant dual pathology of hip and spine and 3. Describe the early term dislocation rate with the use of ≤36mm bearings. This is an IRB-approved, two-center, multi-surgeon, prospective, consecutive, cohort study of 220 patients undergoing THA through anterolateral- (n=103; 46.8%), direct anterior- (n=104; 27.3%) or posterior- approaches (n=13; 5.9%). The mean age was 63.8±12.0 years (range: 27.7-89.0 years) and the mean BMI 28.0±5.0 kg/m. 2. (range: 19.4-44.4 kg/m. 2. ). There were 44 males (47.8%) and 48 females (52.2%). The mean follow-up was 1.6±0.5 years. Overall, 54% of femoral heads was 32 mm, and 46% was 36mm. All participants underwent lateral spinopelvic radiographs in the standing and deep-flexed seated positions were taken to determine lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic-femoral angle (PFA) and pelvic incidence (PI) in both positions. Spinal stiffness was defined as lumbar flexion <20° when transitioning between the standing and deep-seated position; adverse standing PT was defined as >19° and adverse sagittal lumbar balance was defined as mismatch between standing PI and LL >10°. Pre-operative patient reported outcomes was measured using the Oxford Hip Score (OHS) and EuroQol Five-Dimension questionnaire (EQ-5D). Dislocation rates were prospectively recorded. Non-parametric tests were used, significance was set at p<0.05. The prevalence of PI-LL mismatch was 22.1% (43/195) and 30.4% had increased standing PT (59/194). The prevalence of lumbar stiffness was 3.5% (5/142) and these patients had all three adverse spinopelvic characteristics (5/142; 3.5%). There was no significant difference in the pre-operative
Aim. The aim of this study is to evaluate if obesity negatively affects: (1) complication rate, (2) reoperation and revision rate and (3) functional outcome (based on patient reported outcome measures, PROMs) in revision total hip arthroplasty (rTHA). To our knowledge this is the only recent study to prospectively review these three aspects in what might be considered challenging rTHA. Methods. 444 rTHAs (cup, stem, both, n= 265, 57, 122 respectively), performed in a specialized high-volume orthopaedic center from 2013 to 2015, were prospectively followed. Complications and Oxford Hip Score (OHS) were evaluated at 4 months, 1 year and 2 years. Thirtyfour patients had a BMI >35 kg/m2 (obese), of which thirteen patients with a BMI >40 kg/m2 (morbidly obese). Results. Infection following rTHA was more common in obese patients (8/34: 24%) and in morbidly obese patients (5/13: 38%) than in non-obese patients (15/410: 4%; p's < 0.001). No differences between obese and non-obese groups for other complications were observed (aseptic loosening, dislocation, periprosthetic fractures, thromboembolic events). Reoperation and revision rates were similar overall (p = 0.067 / 0.303 respectively) and due to infection (p = 0.469 / 0.879 respectively) for obese and non-obese groups. Scores on the
Aims. Metal-on-metal total hip replacements (MoM THRs) are frequently revised. However, there is a paucity of data on clinical outcomes following revision surgery in this cohort. We report on outcomes from the largest consecutive series of revisions from MoM THRs and consider pre-revision factors which were prognostic for functional outcome. Materials and Methods. A single-centre consecutive series of revisions from MoM THRs performed during 2006–2015 was identified through a prospectively maintained, purpose-built joint registry. The cohort was subsequently divided by the presence or absence of symptoms prior to revision. The primary outcome was functional outcome (Oxford Hip Score (OHS)). Secondary outcomes were complication data, pre- and post-revision serum metal ions and modified Oxford classification of pre-revision magnetic resonance imaging (MRI). In addition, the study data along with demographic data was interrogated for prognostic factors informing on post-revision functional outcome. Results. 180 revisions in 163 patients were identified at a median follow-up of 5.48 (2–11.7) years. There were 152 (84.4%) in the symptomatic subgroup and 28 (15.6%) in the asymptomatic group. Overall median
INTRODUCTION. Wedge femoral stems used in total hip arthroplasty (THA) have evolved with modifications including shorter lengths, reduced distal geometries, and modular necks. Unlike fit and fill stems which contact most of the metaphysis, tapered wedge femoral stems are designed to achieve proximal medial/lateral fixation. These single taper, wedge stems have demonstrated positive clinical outcomes. The tapered wedge stem evaluated in this study has further reduced distal geometry to provide a wedge-fit within the metaphysis of the proximal femoral canal for all femur types (Dorr A, B, C). The objective of this study was to evaluate the early clinical outcomes, including femoral stem subsidence, of a tapered wedge femoral stem. METHODS. Fifty subjects (28 males, 22 females; mean age: 64.7±9.7 years; mean BMI: 29.6±4.6) underwent primary THA with a tapered wedge femoral stem. IRB approval was received prior to conducting the study and all participants signed the informed consent. Clinical data outcomes for this study included the Harris Hip Score (HHS), the Oxford Hip Score (OHS), revisions, and subsidence at the 6-week, 3-month, 1-year, and 2-year post-operative time points. Femoral stem subsidence was measured by an independent third party. Student t-tests were used to identify significant mean differences between genders (p<0.05). RESULTS. For patients returning for their 2-year post- operative visit (n=42), the HHS improved by 40.7 points to 91.9 from 51.2 and the
‘Getting It Right First Time’ guidance recommends the universal use of cemented prostheses in patients aged over 65 within the UK. This cut off has since been raised to 70. The report claims that the increased cost of uncemented technology is not justifiable in terms of patient outcomes. Our aim was to evaluate any disparity between patients across these age thresholds, in terms of functional outcomes, complication and costs following elective uncemented THR. We utilised a single surgeon prospectively updated database, to compare functional outcome of patients aged over and under 65 and again at 70 following elective uncemented THR. We measured functional outcome using Oxford Hip Score (OHS). Patients were followed routinely for up to 2 years and subsequently up to 6 years. Patient ages ranged from 23–89. Over 97% of patients reported an improvement in hip function, with an average increase of 24.1 in
INTRODUCTION. Additive manufacturing (3D printing) is used to create porous surfaces that promote bone ingrowth in an effort to improve initial stability and optimize long-term biological fixation. The acetabular cup that was studied is manufactured with titanium alloy powder via electron beam melting. Electron beam melting integrates the porous and solid substrate rather than sintering a porous coating to a solid surface. The 3D-printed acetabular cup's high surface coefficient of friction (up to 1.2), combined with its geometry, creates a predictable press-fit in the acetabulum, improving initial mechanical stability and ultimately leading to reproducible biologic fixation. The objective of this study was to evaluate the early clinical outcomes and implant fixation of this 3D-printed acetabular cup in total hip arthroplasty (THA). METHODS. Four hundred twenty-eight subjects from 8 US and international research sites underwent primary THA with the 3D-printed acetabular cup. All sites received IRB approval prior to conducting the study, and all participants signed the informed consent. Screw usage and number used during surgery were used as a surrogate measurement for initial implant fixation. Clinical performance outcomes included pre- and post-operative Harris Hip Scores (HHS) and Oxford Hip Scores (OHS), patient satisfaction, and revision assessment. 215 patients had a minimum 1-year post-operative follow-up visit. Student t-tests were used to identify significant mean differences (p<0.05). RESULTS. Acetabular screws were used in 206 of 428 cases (48.1%); 85.9% used 1 screw, 12.6% used 2 screws, and 1.5% used 3 screws. For patients with a 1-year post-operative visit, the HHS improved by 49.8 points to 91.9 from 42.1, and the
Introduction. Instability accounts for one third of revision total hip arthroplasty(rTHA) performed in the United Kingdom. Removal of well-fixed femoral stems in rTHA is challenging with a risk of blood loss and iatrogenic damage to the femur. The Bioball Universal Adaptor (BUA) (Merete, Germany), a modular head neck extension adaptor, provides a mechanism for optimisation of femoral offset, leg length and femoral anteversion. This can avoid the need for femoral stem revision in selected cases. There is a relative paucity of clinical data available with the use of this device. Aim. The aim of this study is to present the clinical results and rate of instability following revision with this head neck adaptor at a minimum of two years' follow up. Patients and Methods. A review of our prospectively collected database was performed. All patients treated with the Bioball device were included. Clinical and radiologic review were performed pre- and post-surgery. Specific enquiry for instability was made. The Oxford Hip Score (OHS), Euro-Quol (EQ-5D) score and WOMAC scores were calculated pre-and post-operatively. Complications were recorded. Statistical analysis using a Students t-test with a significance level of p<0.05 was considered to be statistically significant. Results. Thirty-two rTHA procedures were performed using the Bioball device between 2013 and 2016. Four patients did not wish to complete post-operative questionnaires. These had no complaints regarding their revised hips and were functioning well. Two patients (2/28, 7%) complained of recurrent dislocations following their rTHA procedure. One patient complained of instability but no dislocation. The median pre-operative EQ-5D was 0.195 (range −0.07 to 0.85),
Aim. To assess the influence of route of antibiotic administration on patient-reported outcome measures (PROMS) of individuals treated for hip and knee infections in the OVIVA multi-centre randomised controlled trial. Method. This study was designed to determine whether oral antibiotic therapy is non-inferior to intravenous (IV) therapy when given for the first six weeks of treatment for bone and joint infections. Of the 1054 participants recruited from 26 centres, 462 were treated for periprosthetic or native joint infections of the hip or knee. There were 243 participants in the IV antibiotic cohort and 219 in the oral cohort. Functional outcome was determined at baseline through to one year using the Oxford Hip/Knee Score (OHS/OKS) as joint-specific measures (0 the worse and 48 the best). An adjusted quantile regression model was used to compare functional outcome scores. Results. Of the 214 participants in the hip sub-group, 110 were randomized to IV antibiotics and 104 to oral. Of the 248 participants in the knee cohort, 133 were treated with IV antibiotics and 115 with oral. The
INTRODUCTION. Short femoral stem use in total hip arthroplasty (THA) has increased due to positive short-term clinical and biomechanical success. A neck preserving femoral stem not only preserves proximal bone volume, but preserves the high quality bone of the medial neck. The short stem design allows for less invasive surgical exposure and less invasive violation of the femoral canal (Figure 1). Additionally, it facilitates future revision THA, if needed, with a conventional primary stem. The objective of this study was to evaluate the early clinical outcomes of the Alteon® Neck Preserving Femoral Stem (Exactech, Inc.). METHODS. Forty-nine subjects (25 males, 24 females; mean age: 58.3±7.6 years; mean BMI: 29.8±5.6) from 2 sites underwent primary THA with the Alteon Neck Preserving Femoral Stem. All participants signed the informed consent, and both sites received IRB approval prior to conducting the study. Clinical data outcomes for this study included the Harris Hip Score (HHS), the Oxford Hip Score (OHS), revisions, and subsidence at 3-month, 1-year, and 2-year post-operative time points. Subsidence was measured by an independent third party. Student t-tests were used to identify significant mean differences between genders (p<0.05). RESULTS. The means and standard deviations for the HHS and
Objectives. Total hip arthroplasty (THA) is one of the most successful surgical procedures; several bearing technologies have been used, however none of these is optimal. Metal on polycarbonate-urethane (PCU) is a new bearing technology with several potential advantages: PCU is a hydrophilic soft pliable implant quite similar in elasticity to human cartilage, offers biostability, high resistance to hydrolysis, oxidation, and calcification, no biodegradation, low wear rate and high corrosion resistance and can be coupled with large metal heads (Tribofit Hip System, THS). The aim of this prospective study was to report the survivorship and the clinical and radiographic outcomes and the metal ions dosage of a group of patients operated with metal on PCU arthroplasty featuring large metal diameter heads, at 5 years from surgery. Study Design & Methods. 68 consecutive patients treated with the THS were included. The patients have been contacted by phone call and invited to return to our centre for clinical (Oxford Hip Score,