Advertisement for orthosearch.org.uk
Results 1 - 20 of 693
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 24 - 24
1 Dec 2022
Trisolino G Frizziero L Santi GM Alessandri G Liverani A Menozzi GC Depaoli A Martinelli D Di Gennaro GL Vivarelli L Dallari D
Full Access

Paediatric musculoskeletal (MSK) disorders often produce severe limb deformities, that may require surgical correction. This may be challenging, especially in case of multiplanar, multifocal and/or multilevel deformities. The increasing implementation of novel technologies, such as virtual surgical planning (VSP), computer aided surgical simulation (CASS) and 3D-printing is rapidly gaining traction for a range of surgical applications in paediatric orthopaedics, allowing for extreme personalization and accuracy of the correction, by also reducing operative times and complications. However, prompt availability and accessible costs of this technology remain a concern. Here, we report our experience using an in-hospital low-cost desk workstation for VSP and rapid prototyping in the field of paediatric orthopaedic surgery. From April 2018 to September 2022 20 children presenting with congenital or post-traumatic deformities of the limbs requiring corrective osteotomies were included in the study. A conversion procedure was applied to transform the CT scan into a 3D model. The surgery was planned using the 3D generated model. The simulation consisted of a virtual process of correction of the alignment, rotation, lengthening of the bones and choosing the level, shape and direction of the osteotomies. We also simulated and calculated the size and position of hardware and customized massive allografts that were shaped in clean room at the hospital bone bank. Sterilizable 3D models and PSI were printed in high-temperature poly-lactic acid (HTPLA), using a low-cost 3D-printer. Twenty-three operations in twenty patients were performed by using VSP and CASS. The sites of correction were: leg (9 cases) hip (5 cases) elbow/forearm (5 cases) foot (5 cases) The 3D printed sterilizable models were used in 21 cases while HTPLA-PSI were used in five cases. customized massive bone allografts were implanted in 4 cases. No complications related to the use of 3D printed models or cutting guides within the surgical field were observed. Post-operative good or excellent radiographic correction was achieved in 21 cases. In conclusion, the application of VSP, CASS and 3D-printing technology can improve the surgical correction of complex limb deformities in children, helping the surgeon to identify the correct landmarks for the osteotomy, to achieve the desired degree of correction, accurately modelling and positioning hardware and bone grafts when required. The implementation of in-hospital low-cost desk workstations for VSP, CASS and 3D-Printing is an effective and cost-advantageous solution for facilitating the use of these technologies in daily clinical and surgical practice


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 37 - 37
2 Jan 2024
Mineiro J
Full Access

In March 2020, COVID-19 was declared a pandemic by the World Health Organization. The pandemic imposed drastic changes in our social and professional routine. Professionally at all levels our hospital tasks were changed and prioritized. Surgeons and residents were deployed on rotations to fields other than their expertise in orthopaedics. Health-care education received major changes in these challenging times, and students did face difficulties in receiving education, as well as training due to limited clinical and surgical exposure. In response to the WHO regulations, most of the teaching centres and hospitals worldwide have adopted the web-based teaching and learning model to continue the education and training of orthopaedic residents. These results brought significant changes to the training experience in orthopaedic surgery in combination with the fact that clinical duty hours and case volume were substantially reduced. In what concerns orthopaedic journal publications, the Covid-19 pandemic resulted in a decline in the annual publication rate for the first time in over 20 years. Although not uniform, the reduction was most likely due to multifactorial causes. Regarding the appraisal at the end of training, at the Orthopaedic European Board Examination we were able to verify that the outcome at the written part 1 exam was good, equivalent to the outcome prior to the pandemic. However the oral viva was much worse, probably due to the fact that residents skipped much of the clinical and surgical teaching and exposure during 2020 and 2021. At the end of training, theoretical/factual knowledge was good but poor from the clinical practical experience


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 61 - 61
2 Jan 2024
Winkler T
Full Access

Years ago, we identified the need of a dedicated group and conference for advanced therapies with musculoskeletal indications. We saw a disconnect between high-level science and the criticality of actual medical need, thus creating a gap between research and industry – a gap that needed to be bridged. To achieve this goal, a vehicle to connect and amplify the expertise of key opinion leaders in advanced therapies in orthopaedics was needed. With that purpose in mind and after years of preparation, the “Advanced Therapies in Orthopaedics Foundation” (ATiO) was established with the aim to create a network consisting of all important stake holders in the field, ranging from clinics & research, to corporates, finance and regulators – an Alliance for Advanced Therapies in Orthopaedics to form the future


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 52 - 52
2 Jan 2024
den Borre I
Full Access

Geometric deep learning is a relatively new field that combines the principles of deep learning with techniques from geometry and topology to analyze data with complex structures, such as graphs and manifolds. In orthopedic research, geometric deep learning has been applied to a variety of tasks, including the analysis of imaging data to detect and classify abnormalities, the prediction of patient outcomes following surgical interventions, and the identification of risk factors for degenerative joint disease. This review aims to summarize the current state of the field and highlight the key findings and applications of geometric deep learning in orthopedic research. The review also discusses the potential benefits and limitations of these approaches and identifies areas for future research. Overall, the use of geometric deep learning in orthopedic research has the potential to greatly advance our understanding of the musculoskeletal system and improve patient care


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 43 - 43
17 Nov 2023
Wilkinson H Cool P
Full Access

Abstract. Objectives. The objective of this study is to investigate if genomic sequencing is a useful method to diagnose orthopaedic infections. Current methods used to identify the species of bacteria causing orthopaedic infections take considerable time and the results are frequently insufficient for guiding antibiotic treatment. The aim here is to investigate if genomic sequencing is a faster and more reliable method to identify the species of bacteria causing infections. Current methods include a combination of biochemical markers and microbiological cultures which frequently produce false positive results and false negative results. Methods. Samples of prosthetic fluid were obtained from surgical interventions to treat orthopaedic infections. DNA is extracted from these samples lab and nanopore genomic sequencing is performed. Initial investigations informed that a sequencing time of 15 minutes was sufficient. The resulting genomic sequence data was classified using Basic Local Alignment Tool (BLAST) against the NCBI bacterial database and filtered by only including reads with an identity score of 90 and E-value of 1e-50. An E-value of 1e-50 suggests a high-quality result and is commonly used when analysing genomic data. This data was then filtered in R Studio to identify if any species were associated with orthopaedic infections. The results from genomic sequencing were compared to microbiology results from the hospital to see if the same species had been identified. The whole process from DNA extraction to output took approximately 2 hours, which was faster than parallel microbiological cultures. Results. In these preliminary analyses, 15 samples have been collected from patients with confirmed/suspected orthopaedic infections. To date, 11 samples from confirmed infected patients have been sequenced and a summary of the findings are presented in the table attached. As well as finding bacteria species to match microbiological cultures, genomic sequencing has also identified bacteria when culture results have been negative, but the patient is known to have an infection due to clinical indication and previous culture results. This example suggests genomic sequencing may have higher sensitivity than microbiological cultures at detecting bacteria causing orthopaedic infections. Results in table indicate the identification of bacteria from genomic sequencing that match microbiological cultures are high quality. Conclusions. Preliminary data presented using genomic sequencing suggests that the technique may be useful to identify bacterial species causing orthopaedic infections and can do so in a shorter time frame than current microbial methods. The results from genomic sequencing all produced a number of false positive results which hopefully can be reduced by improving the bioinformatic techniques used and increasing the sample number to include individuals without an infection. Further analysis will also look at identifying antibiotic resistance genes in the sequencing data and seeing if this ca be used to predict which patients will and will not respond to antibiotic treatment. The aim at the end of this project is to demonstrate if genomic sequencing is a more sensitive method to identify bacteria causing orthopaedic infections that current methods and if it can be used to guide antibiotic treatment. Include limitations, next steps and bigger picture. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 48 - 48
2 Jan 2024
Emmanuel A
Full Access

Non-linear methods in statistical shape analysis have become increasingly important in orthopedic research as they allow for more accurate and robust analysis of complex shape data such as articulated joints, bony defects and cartilage loss. These methods involve the use of non-linear transformations to describe shapes, rather than the traditional linear approaches, and have been shown to improve the precision and sensitivity of shape analysis in a variety of applications. In orthopedic research, non-linear methods have been used to study a range of topics, including the analysis of bone shape and structure in relation to osteoarthritis, the assessment of joint deformities and their impact on joint function, and the prediction of patient outcomes following surgical interventions. Overall, the use of non-linear methods in statistical shape analysis has the potential to advance our understanding of the relationship between shape and function in the musculoskeletal system and improve the diagnosis and treatment of orthopedic conditions


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 15 - 15
2 Jan 2024
Costa B Alves P Fonseca D Campos F Monteiro AC Pereira R Costa F Gomes P Martínez-de-Tejada G Monteiro C Martins M
Full Access

Orthopedic Device-Related Infections (ODRIs) are a major medical challenge, particularly due to the involvement of biofilm-encased and multidrug-resistant bacteria. Current treatments, based on antibiotic administration, have proven to be ineffective. Consequently, there is a need for antibiotic-free alternatives. Antimicrobial peptides (AMPs) are a promising solution due to their broad-spectrum of activity, high efficacy at very low concentrations, and low propensity to induce resistance. We aim to develop a new AMP-based chitosan nanogel to be injected during orthopedic device implantation to prevent ODRIs. Chitosan was functionalized with norbornenes (NorChit) through the reaction with carbic anhydride and then, a cysteine-modified AMP, Dhvar5, a peptide with potent antibacterial activity, even against methicillin-resistant Staphylococcus aureus (MRSA), was covalently conjugated to NorChit (NorChit- Dhvar5), through a thiol-norbornene photoclick chemistry (UV= 365 nm). For NorChit-Dhvar5 nanogels production, the NorChit-Dhvar5 solution (0.15% w/v) and Milli-Q water were injected separately into microfluidic system. The nanogels were characterized regarding size, concentration, and shape, using Transmission Electron Microscopy (TEM), Nanoparticle Tracking Analysis (NTA) and Dynamic light scattering (DLS). The nanogels antibacterial properties were assessed in Phosphate Buffer (PBS) for 6 h, against four relevant microorganisms (Pseudomonas aeruginosa, S. aureus and MRSA, and in Muller- Hinton Broth (MHB), 50% (v/v) in PBS, supplemented with human plasma (1% (v/v)), for 6 and 24 h against MRSA. The obtained NorChit-Dhvar5 nanogels, presented a round-shaped and ∼100 nm. NorChit- Dhvar5 nanogels in a concentration of 10. 10. nanogels/mL in PBS were capable of reducing the initial inoculum of P. aeruginosa by 99%, S. aureus by 99%, and MRSA by 90%. These results were corroborated by a 99% MRSA reduction, after 24 h in medium. Furthermore, NorChit-Dhvar5 nanogels do not demonstrate signs of cytotoxicity against MC3T3-E1 cells (a pre-osteoblast cell line) after 14 days, having high potential to prevent antibiotic-resistant infection in the context of ODRIs


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 58 - 58
2 Jan 2024
Richter B
Full Access

An overview about 3D printing technology in orthopaedic applications will be given based on examples. The process from early prototypes to certified implants coming from serial production will be demonstrated also considering relevant surrounding conditions. Today's focus is mostly on orthopaedic implants, but there is a high potential for new implant-related surgical instrument solutions taking into account up-coming clinical demands and user needs accessible by actual 3D printing technologies


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 88 - 88
4 Apr 2023
Anjum S Kirby J Deehan D Tyson-Capper A
Full Access

The most common reason for revision surgery of total hip replacements is aseptic loosening of implants secondary to osteolysis, which is caused by immune-mediated reactions to implant debris. These debris can cause pseudotumour formation. As revision surgery is associated with higher mortality and infection, it is important to understand the pro-inflammatory process to improve implant survival. Toll-like receptor 4 (TLR4) has been shown to mediate immune responses to cobalt ions. Statin use in epidemiological studies has been associated with reduced risk of revision surgery. In-vitro studies have demonstrated the potential for statins to reduce orthopaedic debris-induced immune responses and there is evidence that statins can modulate TLR4 activity. This study investigates simvastatin's effect on orthopaedic biomaterial-mediated changes in protein expression of key inflammatory markers and soluble-ICAM-1 (sICAM-1), an angiogenic factor implicated in pseudotumour formation. Human macrophage THP-1 cells were pre-incubated with 50µM simvastatin for 2-hours or a vehicle control (VC), before being exposed to 0.75mM cobalt chloride, 50μm3 per cell zirconium oxide or LPS as a positive control, in addition to a further 24-hour co-incubation with 50µM simvastatin or VC. Interleukin −8 (IL-8), sICAM-1, chemokine ligand 2 (CCL2), CCL3 and CCL4 protein secretion was measured by enzyme-linked immunosorbent assay (ELISA). GraphPad Prism 10 was used for statistical analysis including a one-way ANOVA. Pre-treatment with simvastatin significantly reduced LPS and cobalt-mediated IL-8 secretion (n=3) and sICAM-1 protein secretion (n=2) in THP-1 cells. Pre-treatment with simvastatin significantly reduced LPS-mediated but not cobalt ion-mediated CCL2 (n=3) and CCL3 protein (n=3) secretion in THP-1 cells. Simvastatin significantly reduced zirconium oxide-mediated CCL4 secretion (n=3). Simvastatin significantly reduced cobalt-ion mediated IL-8 and sICAM-1 protein secretion in THP-1 cells. This in-vitro finding demonstrates the potential for simvastatin to reduce recruitment of leukocytes which mediate the deleterious inflammatory processes driving implant failure


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 127 - 127
4 Apr 2023
Sankar S Antonik M Hassan S
Full Access

The e-scooter trial was part of a wider initiative from the Department for Transport in response to COVID pandemic. New emergency legislation was introduced in 2020 to make e-scooters legal in the UK for the first time. This scheme was launched in our county from September 2020. The aim of this case series was to identify the types of Orthopedic injuries resultant from electric scooter transport that presented to our District General Hospital over a 16-month period between September 2020 and December 2021. This study involved retrospective collection of data from electronic hospital records. Data on demographics, laterality, date of injury, type of injury, treatment, HDU/ITU admissions, mortality, and operating time were collected to characterize the types of e-scooter-related injuries and to investigate the frequency of such injuries over the duration of our search. A total of 79 orthopedic patients identified with electric scooter injuries between September 2020 and December 2021. 78.5% were males and the mean age was 30.1 years. Summer months accounted for most of the injuries. 17 patients required inpatient care. 23 patients required surgical intervention and a total of 29 surgeries were performed in our hospital. This accounted for a total surgical time of 2088 minutes. One patient admitted with shaft of femur fracture developed pulmonary embolism after the definitive operation and died in HDU. Electric scooters provide a space efficient, affordable, environmentally friendly mode of transportation which reduce the urban congestion and parking issues. This study demonstrates an increasing frequency of significant orthopedic injury associated with e-scooter use treated at our centre over the course of 16 months. This small series underlines an important problem given that this increase has occurred after the start of the electric scooter trial. Legalization might result in further increase in the incidence of injury


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 86 - 86
4 Apr 2023
Joumah A Al-Ashqar M Richardson G Bakhshayesh P Kanakaris N
Full Access

The aim of this study was to assess the impact of Covid-19 measures on the rate of surgical site infections (SSI) and subsequent readmissions in orthopaedic patients. Retrospective, observational study in a level 1 major trauma center comparing rates of SSI in orthopaedic patients who underwent surgery prior to the Covid-19 lockdown versus that of patients who underwent surgery during the lockdown period. A total of 1151 patients were identified using electronic clinical records over two different time periods; 3 months pre Covid-19 lockdown (n=680) and 3 months during the Covid-19 lockdown (n=470). Patients were followed up for 1 year following their initial procedure. Primary outcome was readmission for SSI. Secondary outcomes were treatment received and requirement for further surgeries. The most commonly performed procedures were arthroplasty and manipulation under anaesthesia with 119 in lockdown vs 101 non-lockdown (p=0.001). The readmission rate was higher in the lockdown group with 61 (13%) vs 44 (6.5%) in the non-lockdown group (p <0.001). However, the majority were due to other surgical complications such as dislocations. Interestingly, the SSI rates were very similar with 24 (5%) in lockdown vs 28 (4%) in non-lockdown (p=0.472). Twenty patients (4.2%) required a secondary procedure for their SSI in the lockdown group vs 24 (3.5%) in non-lockdown (p=0.381). Mortality rate was similar at 44 (9.3%) in lockdown vs 61 (9.0%; p=0.836). Whilst Covid-19 precautions were associated with higher readmission rates, there was no significant difference in rate of SSI between the two groups


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 23 - 23
11 Apr 2023
Keen R Liu J Williams A Wood S
Full Access

X-Linked Hypophosphataemia (XLH) is a rare, progressive, hereditary phosphate-wasting disorder characterised by excessive activity of fibroblast growth factor 23. The International XLH Registry was established to provide information on the natural history of XLH and impact of treatment on patient outcomes. The cross-sectional orthopaedic data presented are from the first interim analysis. The XLH Registry (NCT03193476) was initiated in August 2017, aims to recruit 1,200 children and adults with XLH, and will run for 10 years. At the time of analysis (Last Patient In: 30/11/2020; Database Lock: 29/03/2021) 579 subjects diagnosed with XLH were enrolled from 81 hospital sites in 16 countries (360 (62.2%) children, 217 (37.5%) adults, and 2 subjects of unknown age). Of subjects with retrospective clinical data available, skeletal deficits were the most frequently self-reported clinical problems for children (223/239, 93.3%) and adults (79/110, 71.8%). Retrospective fracture data were available for 183 subjects (72 children, 111 adults); 50 had a fracture (9 children, 41 adults). In children, fractures tended to occur in tibia/fibula and/or wrist; only adults reported large bone fractures. Joint conditions were noted for 46 subjects (6 children, 40 adults). For adults reporting osteoarthritis, knees (60%), hips (42.5%), and shoulders (22.5%) were the most frequently affected joints. Retrospective orthopaedic surgery data were collected for 151 subjects (52 children, 99 adults). Osteotomy was the most frequent surgery reported (n=108); joint replacements were recorded for adults only. This is the largest set of orthopaedic data from XLH subjects collected to date. Longitudinal information collected during the 10-year Registry duration will generate real-world evidence which will help to inform clinical practice. Authors acknowledge the contribution of all International XLH Registry Steering Committee members


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 90 - 90
4 Apr 2023
Sharma M Khanal P Patel N Patel A
Full Access

To investigate the utility of virtual reality (VR) simulators in improving surgical proficiency in Orthopaedic trainees for complex procedures and techniques. Fifteen specialty surgeons attending a London Orthopaedic training course were randomised to either the VR (n = 7) or control group (n = 8). All participants were provided a study pack comprising an application manual and instructional video for the Trochanteric Femoral Nail Advanced (TFNA) procedure. The VR group underwent additional training for TFNA using the DePuy Synthes (Johnson and Johnson) VR simulator. All surgeons were then observed applying the TFNA in a Sawbones model and assessed by a blinded senior consultant using three metrics: time to completion, 22-item procedure checklist and 5-point global assessment scale. Participant demographics for the VR and control groups were similar in context of age (mean [SD]: VR group, 31.0 [2.38] years; control group, 30.6 [2.39] years), gender (VR group, 5 [71%] men; control group, 8 [100%] men) and prior experience with TFNA (had applied TFNA as primary surgeon: VR group, 6 [86%]; control group, 7 [88%]). Although statistical significance was not reached, the VR group, on average, outperformed the control group on all three metrics. They completed the TFNA procedure faster (mean [SD]: 18.2 [2.16] minutes versus 19.78 [1.32] minutes; p<0.189), performed a greater percentage of steps correctly (79% versus 66%; p<0.189) and scored a higher percentage on the global assessment scale (75% versus 65%; p<0.232). VR simulators offer a safe and accessible means for Orthopaedic trainees to prepare for and supplement their theatre-based experience. It is vital, therefore, to review and validate novel simulation-based systems and in turn facilitate their improvement. We intend to increase our sample size and expand this preliminary study through a second upcoming surgical course for Orthopaedic trainees in London


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 131 - 131
2 Jan 2024
Vadalà G
Full Access

Infections are among the most diffused complications of the implantation of medical devices. In orthopedics, they pose severe societal and economic burden and interfere with the capability of the implants to integrate in the host bone, significantly increasing failure risk. Infection is particularly severe in the case of comorbidities and especially bone tumors, since oncologic patients are fragile, have higher infection rate and impaired osteoregenerative capabilities. For this reason, prevention of infection is to be preferred over treatment. This is even more important in the case of spine surgery, since spine is among the main site for tumor metastases and because incidence of post operative surgical-site infections is significant (up to 15-20%) and surgical options are limited by the need of avoiding damaging the spinal cord. Functionalization of the implant surfaces, so as to address infection and, possibly, co- adjuvate anti-tumor treatments, appears as a breakthrough innovation. Unmet clinical needs in infection and tumors is presented, with a specific focus on the spine, then, new perspectives are highlighted for their treatment


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 59 - 59
17 Nov 2023
Yang I Buchanan R Al-Namnam N Li X Lucas M Simpson AH
Full Access

Abstract. Background. Ultrasonic cutting of bone boasts many advantages over alternatively powered surgical instruments, including but not limited to: elimination of swarf, reduced reaction forces, increased precision in cutting and reduced adjacent soft tissue damage, reduced post-operative complications such as bleeding and bone fracture, reduced healing time, reduced intra-operative noise and ease of handling. Despite ultrasonic cutting devices being well established in oral and maxillofacial surgery, applications in orthopaedic surgery are more niche and are not as well understood. The aim of this study was to investigate the cutting speed (mm/s) and cutting forces (N) of orthopaedic surgeons using a custom-designed state of the art ultrasonic cutting tool to cut fresh human bone samples. Methods. A setup based on the Robot Operating System (ROS) and AprilTag was designed to track and to record the real time position of the ultrasonic cutting tool in space. Synchronised load cell axial force readings of three separate orthopaedic surgeons during ultrasonic cutting were recorded. Each surgeon was asked to find a comfortable position that reflects as close as possible their clinical handling of a cutting instrument used in surgery, and to perform two cuts in each of three samples of human cortical bone. Bone samples were obtained following ethical approval from an institutional review board (ethics approval number: SR1342) and prior informed consent was obtained from all patients. Bone samples were extracted from the femoral neck region of three hip osteoarthritis patients. During cutting, surgeons were allowed a total cutting time of one minute and cutting was conducted using an ultrasonic tool with frequency of a 35kHz (35.7 µm peak to peak displacement amplitude) under constant irrigation using a MINIPULS® 3 Peristaltic pump (38 revolutions per minute) using Phosphate-Buffered Saline (PBS) at 25°C. From the recorded data, the average instantaneous cutting velocity was calculated and the maximum cutting force was identified. Results. All surgeons assumed a back-and-forth cutting motion, variation in the applied cutting force was observed. The average vertical cutting speed, axial cutting force and cutting depth across all surgeons and all samples was 1.64 mm/s, 1.91 N and 0.73 mm, respectively. While increasing the axial cutting force resulted in a deeper cut, overloading of the ultrasound transducer occurred when the tool advanced too quickly into the bone tissue during cutting. The exact force threshold, or the optimal speed at which the surgeon can maintain a constant force during cutting, requires further investigation. Conclusions. In this study, all surgeons cut using a back-and-forth cutting motion, with variation in the applied cutting force which may ultimately inform which clinical applications in orthopaedic engineering are most suitable for this technology. Applying too much force caused overloading of the ultrasound transducer, which is a limitation with the current cutting tool. The results from this study may facilitate the eventual uptake of ultrasonic cutting tools for application in orthopaedic surgery. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 15 - 15
1 Dec 2022
Graziani G Ghezzi D Sartori M Fini M Perut F Montesissa M Boi M Cappelletti M Sassoni E Di Pompo G Giusto E Avnet S Monopoli D Baldini N
Full Access

Infection in orthopedics is a challenge, since it has high incidence (rates can be up to 15-20%, also depending on the surgical procedure and on comorbidities), interferes with osseointegration and brings severe complications to the patients and high societal burden. In particular, infection rates are high in oncologic surgery, when biomedical devices are used to fill bone gaps created to remove tumors. To increase osseointegration, calcium phosphates coatings are used. To prevent infection, metal- and mainly silver-based coatings are the most diffused option. However, traditional techniques present some drawbacks, including scarce adhesion to the substrate, detachments, and/or poor control over metal ions release, all leading to cytotoxicity and/or interfering with osteointegration. Since important cross-relations exist among infection, osseointegration and tumors, solutions capable of addressing all would be a breakthrough innovation in the field and could improve clinical practice. Here, for the first time, we propose the use antimicrobial silver-based nanostructured thin films to simultaneously discourage infection and bone metastases. Coatings are obtained by Ionized Jet Deposition, a plasma-assisted technique that permits to manufacture films of submicrometric thickness having a nanostructured surface texture. These characteristics, in turn, allow tuning silver release and avoid delamination, thus preventing toxicity. In addition, to mitigate interference with osseointegration, here silver composites with bone apatite are explored. Indeed, capability of bone apatite coatings to promote osseointegration had been previously demonstrated in vitro and in vivo. Here, antibacterial efficacy and biocompatibility of silver-based films are tested in vitro and in vivo. Finally, for the first time, a proof-of-concept of antitumor efficacy of the silver-based films is shown in vitro. Coatings are obtained by silver and silver-bone apatite composite targets. Both standard and custom-made (porous) vertebral titanium alloy prostheses are used as substrates. Films composition and morphology depending on the deposition parameters are investigated and optimized. Antibacterial efficacy of silver films is tested in vitro against gram+ and gram- species (E. coli, P. aeruginosa, S. aureus, E. faecalis), to determine the optimal coatings characteristics, by assessing reduction of bacterial viability, adhesion to substrate and biofilm formation. Biocompatibility is tested in vitro on fibroblasts and MSCs and, in vivo on rat models. Efficacy is also tested in an in vivo rabbit model, using a multidrug resistant strain of S. aureus (MRSA, S. aureus USA 300). Absence of nanotoxicity is assessed in vivo by measuring possible presence of Ag in the blood or in target organs (ICP-MS). Then, possible antitumor effect of the films is preliminary assessed in vitro using MDA-MB-231 cells, live/dead assay and scanning electron microscopy (FEG-SEM). Statistical analysis is performed and data are reported as Mean ± standard Deviation at a significance level of p <0.05. Silver and silver-bone apatite films show high efficacy in vitro against all the tested strains (complete inhibition of planktonic growth, reduction of biofilm formation > 50%), without causing cytotoxicity. Biocompatibility is also confirmed in vivo. In vivo, Ag and Ag-bone apatite films can inhibit the MRSA strain (>99% and >86% reduction against ctr, respectively). Residual antibacterial activity is retained after explant (at 1 month). These studies indicate that IJD films are highly tunable and can be a promising route to overcome the main challenges in orthopedic prostheses


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 95 - 95
4 Apr 2023
Troiano E Giacomo P Di Meglio M Nuvoli N Mondanelli N Giannotti S Orlandi N
Full Access

Infections represent a devastating complication in orthopedic and traumatological surgery, with high rates of morbidity and mortality. An early intervention is essential, and it includes a radical surgical approach supported by targeted intravenous antimicrobial therapy. The availability of parenteral antibiotics at the site of infection is usually poor, so it is crucial to maximize local antibiotic concentration using local carriers. Our work aims to describe the uses of one of these systems, Stimulan®, for the management and prevention of infections at our Institution. Analysing the reported uses of Stimulan®, we identified two major groups: bone substitute and carrier material for local antibiotic therapy. The first group includes its application as a filler of dead spaces within bone or soft tissues resulting from traumatic events or previous surgery. The second group comprehends the use of Stimulan® for the treatment of osteomyelitis, post-traumatic septic events, periprosthetic joint infections, arthroplasty revision surgery, prevention in open fractures, surgery of the diabetic foot, oncological surgery and for all those patients susceptible to a high risk of infection. We used Stimulan® in several complex clinical situations: in PJIs, in DAPRI procedure and both during the first and the second stage of a 2-stage revision surgery; furthermore, we started to exploit this antibiotic carrier also in prophylaxis of surgical site infections, as it happens in open fractures, and when a surgical site remediation is required, like in osteomyelitis following ORIF. Stimulan® is an extremely versatile and polyhedric material, available in the form of beads or paste, and can be mixed to a very broad range of antibiotics to better adapt to different bacteria and their antibiograms, and to surgeon's needs. These properties make it a very useful adjuvant for the management of complex cases of infection, and for their prevention, as well


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 96 - 96
11 Apr 2023
Crippa Orlandi N De Sensi A Cacioppo M Saviori M Giacchè T Cazzola A Mondanelli N Giannotti S
Full Access

The computational modelling and 3D technology are finding more and more applications in the medical field. Orthopedic surgery is one of the specialties that can benefit the most from this solution. Three case reports drawn from the experience of the authors’ Orthopedic Clinic are illustraded to highlight the benefits of applying this technology. Drawing on the extensive experience gained within the authors’ Operating Unit, three cases regarding different body segments have been selected to prove the importance of 3D technology in preoperative planning and during the surgery. A sternal transplant by allograft from a cryopreserved cadaver, the realization of a custom made implant of the glenoid component in a two-stage revision of a reverse shoulder arthroplasty, and a case of revision on a hip prosthesis with acetabular bone loss (Paprosky 3B) treated with custom system. In all cases the surgery was planned using 3D processing software and models of the affected bone segments, printed by 3D printer, and based on CT scans of the patients. The surgical implant was managed with dedicated instruments. The use of 3D technology can improve the results of orthopedic surgery in many ways: by optimizing the outcomes of the operation as it allows a preliminary study of the bone loss and an evalutation of feasibility of the surgery, it improves the precision of the positioning of the implant, especially in the context of severe deformity and bone loss, and it reduces the operating time; by improving surgeon training; by increasing patient involvement in decision making and informed consent. 3D technology, by offering targeted and customized solutions, is a valid tool to obtain the tailored care that every patient needs and deserves, also providing the surgeon with an important help in cases of great complexity


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 26 - 26
17 Apr 2023
Bhattacharya S
Full Access

Radioprotective gowns are an essential part of operating in orthopaedicse. As we are aware from the evidence, surgeons, and in particular orthopaedic surgeons, are at risk of developing chronic neck and back pain. This is likely a result of the combination of of long operations, heavy equipment, radioprotective gowns and poor ergonomic set up. Women are a minority in orthopaedics. Amongst trainees there has been an improvement with 20–25% of current trainees are women, however at consultant level this percentage is a lot lower at 5–7%. Radioprotective gowns worn by trainees are frequently not well fitted and few surgeons have access to bespoke fitted gowns. A questionnaire given to 32 trainees in the region found a significant burden of back pain in trainees and 57% of surgeons felt their gowns were not appropriately fitted. In this study every woman questioned reported back pain as a result of operating and 87% felt the gowns used exacerbated back pain, this figure was 56% in men. 80% of surgeons felt that surgeons would benefit from bespoke fitted gowns, even those that did not themselves have severe back pain. 45% of trainees felt their pain was moderate to severe. In surgery we have the responsibility to protect ourselves and our colleagues from work based injury and illness. Back pain should not be ignored as a symptom and radioprotective gowns is a good place to start. Overall the majority the gowns exacerbated their back pain during or after procedures, worse in women as described above. We can use this data and do what we can to provide trainees with a range of sizes whilst working in hospitals during their training. Anectodally women sizes were less available in the departments and we can work to improve this and reduce the burden of pain amongst surgeons


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 10 - 10
17 Apr 2023
Constant C Moriarty T Pugliese B Arens D Zeiter S
Full Access

Orthopedic device-related infection (ODRI) preclinical models are widely used in translational research. Most models require induction of general anesthesia, which frequently results in hypothermia in rodents. This study aimed to evaluate the impact of peri anesthetic hypothermia in rodents on outcomes in preclinical orthopedic device-related infection studies. A retrospective analysis of all rodents that underwent surgery under general anesthesia to induce an ODRI model with inoculation of Staphylococcus epidermidis between 2016 and 2020 was conducted. A one-way multivariate analysis of covariance was used to determine the fixed effect of peri anesthetic hypothermia (hypothermic defined as rectal temperature <35°C) on the combined harvested tissue and implant colonies forming unit counts, and having controlled for the study groups including treatments received duration of surgery and anesthesia and study period. All animal experiments were approved by relevant ethical committee. A total of 127 rodents (102 rats and 25 mice) were enrolled in an ODRI and met the inclusion criteria. The mean lowest peri-anesthetic temperature was 35.3 ± 1.5 °C. The overall incidence of peri-anesthetic hypothermia was 41% and was less frequently reported in rats (34% in rats versus 68% in mice). Statistical analysis showed a significant effect of peri anesthetic hypothermia on the post-mortem combined colonies forming unit counts from the harvested tissue and implant(s) (p=0.01) when comparing normo- versus hypothermic rodents. Using Wilks’ Λ as a criterion to determine the contribution of independent variables to the model, peri-anesthetic hypothermia was the most significant, though still a weak predictor, of increased harvested colonies forming unit counts. Altogether, the data corroborate the concept that bacterial colonization is affected by abnormal body temperature during general anesthesia at the time of bacterial inoculation in rodents, which needs to be taken into consideration to decrease infection data variability and improve experimental reproducibility