Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_9 | Pages 29 - 29
1 Feb 2013
Hill D Kinsella D Toms A
Full Access

We report the largest multicentre series analysing the use of bone scans investigating painful post-operative Total Knee Replacements (TKR). We questioned the usefulness of reported scintigraphic abnormalities, and how often this changed subsequent management. 127 three-phase bone-scans were performed during a two-year period. Early and late flow phases were objectively classified. Reported incidences of infection and loosening were determined. Reports were subjectively summarised and objectively analysed to establish the usefulness of this investigation. Eight cases were excluded.

Scans were classified as: 33% (39) normal, 53% (63) as possibly abnormal, 6% (7) probably abnormal, and 8% (10) as definitely abnormal. Thirteen patients (11%) underwent revision TKR surgery. Intra-operative analysis revealed loosening of one femoral component, and massive metallosis of the patella in another. Cultures were negative in all cases. The sensitivity and specificity of a definitely abnormal investigation in predicting need for revision surgery was 23% and 82% (respectively). High instances of ambiguously reported abnormalities were observed.

This investigation has no role to play in the routine investigation of a painful TKR. It is unnecessary in investigation of periprosthetic infection and should not be used in a routine assessment of a painful TKR. If used it should be limited until an experienced revision surgeon has made a full assessment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 8 - 8
1 Jul 2012
Sarraf K Abdul-Jabar H Wharton R Shah G Singer G
Full Access

Femoral component fracture is a rarely reported but devastating complication of total knee arthroplasty. It has occurred most frequently with Whiteside Ortholoc II replacements uncemented knee replacements. Presentation may be with acute pain, progressive pain or returning deformity. It occurs more commonly in the medial condyle of the femoral component. It is rarely seen in cemented replacements. All currently available literature describing fractures of condylar replacements, both cemented and uncemented. Predisposing factors include varus deformity either pre or post operatively. The mechanism of failure is thought to be failure of the infiltration of bone into the replacement. This is often due to polyethylene wear or metallosis causing abnormal tissue reaction with or without osteolysis. We present the case of a fractured Press Fit Condylar (PFC) cemented implant (DePuy, Johnson&Johnson, Raynham, Massachusettes, USA) affecting the medial condyle. To our knowledge this is only the third reported case of fracture in a PFC implant, and the first in a cemented PFC implant. Our patient was a 64 year old male who presented with unresolving knee pain post total knee arthroplasty, caused by fatigue fracture of the medial condyle of the femoral component. This was identified as loosening on plain radiographs and replaced with a revision prosthesis with a good post operative result. Given our aging population and with the increase of joint arthroplasty, this case sheds light on a potentially under recognised and increasingly important cause of knee pain following arthroplasty