The peri-prosthetic tissue response to wear debris
is complex and influenced by various factors including the size, area
and number of
It is reported that more than 10 million Japanese suffer from arthrosis. To cure these cartilage defects, total joint replacements, which are the most popular treatment methods for severe disease situation, have been operated as about two hundred thousand cases a year in Japan. Although the implants made of either ceramics, metals or plastics have high wear resistance quality, it becomes apparent that the endurance life of the artificial joints in considerable cases is limited by aseptic loosening to between 10–15 years. Here we focused on a poly(vinyl alcohol) (PVA) hydrogel as an artificial cartilage tissue to make an improvement of friction surface of the artificial joints. In this paper, we observed morphology of wear
Aims. Vitamin E-infused highly cross-linked polyethylene (E1) has recently been introduced in total knee arthroplasty (TKA). An in vitro wear simulator study showed that E1 reduced polyethylene wear. However there is no published information regarding in vivo wear. Previous reports suggest that newly introduced materials which reduce in vitro polyethylene wear do not necessarily reduce in vivo polyethylene wear. To assist in the evaluation of the newly introduced material before widespread use, we established an in vivo polyethylene wear
We revised seven alumina-blasted cementless hip prostheses (Ti-alloy stems, cp Ti threaded sockets) with low- or high-carbon Co-alloy bearings at a mean of 20.1 months after implantation because of pain and loosening. Histological examination of the retrieved periprosthetic tissues from two cases in which the implant was stable and three in which the socket was loose showed macrophages with basophilic granules containing metal and alumina wear
Objectives. This study aimed to characterise and qualitatively grade the severity of the corrosion
In an attempt to increase the life of cementless prostheses, an hydroxyapatite-coated implant which releases a bisphosphonate has been suggested as a drug-delivery system. Our in vitro study was designed to determine the maximum dose to which osteoblasts could be safely exposed. Our findings demonstrated that zoledronate did not impair the proliferation of human osteoblasts when used at concentrations below 1 μ. m. Murine cells can be exposed to concentrations as high as 10 μ. m. . A concentration of 0.01% of titanium
Background. Polyethylene (PE) as a bearing material for total joint replacements (TJR) represents the golden standard for the past forty years. However, over the past decade it becomes apparent that PE wear and the biological response to wear products are the limiting factor for the longevity of TJRs. For this reason research has focused onto PE wear
Nanometre-sized
Summary Statement. Antioxidant containing UHMWPE
Introduction. The complex process of inflammation and osteolysis due to wear
Demineralized bone matrix (DBM) is a natural, collagen-based, well-established osteoinductive biomaterial. Nevertheless, there are conflicting reports on the efficacy of this product. The purpose of this study was to evaluate whether DBM collagen structure is affected by
Abundant implant-derived biomaterial wear
Despite many claims of good wear properties following
total knee replacement (TKR) with an oxidised zirconium (OxZr) femoral
component, there are conflicting clinical results. We hypothesised
that there would be no difference in either the mid-term clinical
and radiological outcomes or the characteristics of the polyethylene
wear
The biological significance of cobalt-chromium wear
The generation of
INTRODUCTION. Loosening is concerned to be the major cause of revision in the artificial prosthesis. Wear debris of UHMWPE dispersed into the implant-bone interface are phagocytosed by macrophages releasing inflammatory cytokines such as TNF-α which leads to osteolysis and loosening eventually. It is known that the size and structure [1] as well as attached substances on
We investigated in vitro a mechanism by which particulate debris may induce bone resorption and cause implant loosening. We first studied two standard
Today's aging society is seeing an increase of patients with rheumatoid arthritis and osteoarthritis, as well as an increase in joint replacement surgery. The artificial joints used in this surgery frequently uses ultra-high molecular weight polyethylene (UHMWPE) as a bearing material. However, UHMWPE wear
Tissue reaction to wear
We implanted bone harvest chambers (BHCs) bilaterally in ten mature male New Zealand white rabbits. Polyethylene