Advertisement for orthosearch.org.uk
Results 1 - 20 of 459
Results per page:
Bone & Joint Open
Vol. 5, Issue 7 | Pages 592 - 600
18 Jul 2024
Faschingbauer M Hambrecht J Schwer J Martin JR Reichel H Seitz A

Aims. Patient dissatisfaction is not uncommon following primary total knee arthroplasty. One proposed method to alleviate this is by improving knee kinematics. Therefore, we aimed to answer the following research question: are there significant differences in knee kinematics based on the design of the tibial insert (cruciate-retaining (CR), ultra-congruent (UC), or medial congruent (MC))?. Methods. Overall, 15 cadaveric knee joints were examined with a CR implant with three different tibial inserts (CR, UC, and MC) using an established knee joint simulator. The effects on coronal alignment, medial and lateral femoral roll back, femorotibial rotation, bony rotations (femur, tibia, and patella), and patellofemoral length ratios were determined. Results. No statistically significant differences were found regarding coronal alignment (p = 0.087 to p = 0.832). The medial congruent insert demonstrated restricted femoral roll back (mean medial 37.57 mm; lateral 36.34 mm), while the CR insert demonstrated the greatest roll back (medial 42.21 mm; lateral 37.88 mm; p < 0.001, respectively). Femorotibial rotation was greatest with the CR insert with 2.45° (SD 4.75°), then the UC insert with 1.31° (SD 4.15°; p < 0.001), and lowest with the medial congruent insert with 0.8° (SD 4.24°; p < 0.001). The most pronounced patella shift, but lowest patellar rotation, was noted with the CR insert. Conclusion. The MC insert demonstrated the highest level of constraint of these inserts. Femoral roll back, femorotibial rotation, and single bony rotations were lowest with the MC insert. The patella showed less shifting with the MC insert, but there was significantly increased rotation. While the medial congruent insert was found to have highest constraint, it remains uncertain if this implant recreates native knee kinematics or if this will result in improved patient satisfaction. Cite this article: Bone Jt Open 2024;5(7):592–600


The Bone & Joint Journal
Vol. 103-B, Issue 10 | Pages 1555 - 1560
4 Oct 2021
Phillips JRA Tucker K

Aims. Knee arthroplasty surgery is a highly effective treatment for arthritis and disorders of the knee. There are a wide variety of implant brands and types of knee arthroplasty available to surgeons. As a result of a number of highly publicized failures, arthroplasty surgery is highly regulated in the UK and many other countries through national registries, introduced to monitor implant performance, surgeons, and hospitals. With time, the options available within many brand portfolios have grown, with alternative tibial or femoral components, tibial insert materials, or shapes and patella resurfacings. In this study we have investigated the effect of the expansion of implant brand portfolios and where there may be a lack of transparency around a brand name. We also aimed to establish the potential numbers of compatible implant construct combinations. Methods. Hypothetical implant brand portfolios were proposed, and the number of compatible implant construct combinations was calculated. Results. A simple knee portfolio with cemented cruciate-retaining (CR) and posterior-stabilized (PS) components, with and without a patella, has four combinations. If there are two options available for each component, the numbers double for each option, resulting in 32 combinations. The effect of adding a third option multiplies the number by 1.3. Introducing compatible uncemented options, with the effect of hybrids, multiplies the number by 4. An implant portfolio with two femoral components (both in CR and PS), with two insert options and a patella, all in cemented and uncemented versions leads to 192 possible compatible implant construct combinations. There are implant brands available to surgeons with many more than two options. Conclusion. This study demonstrates that the addition of multiple variants within a knee brand portfolio leads to a large number (many hundreds) of compatible implant construct combinations. Revision rates of implant combinations are not currently reviewed at this level of granularity, leading to the risk of camouflage of true outcomes. Cite this article: Bone Joint J 2021;103-B(10):1555–1560


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 29 - 29
7 Aug 2023
Mayne A Rajgor H Munasinghe C Agrawal Y Pagkalos I Davis E Sharma A
Full Access

Abstract. Introduction. There is growing interest in the use of robotic Total Knee Arthroplasty (TKA) to improve accuracy of component positioning. This is the first study to investigate the radiological accuracy of implant component position using the ROSA® knee system with specific reference to Joint Line Height, Tibial Slope, Patella Height and Posterior Condylar Offset. As secondary aims we compared accuracy between image-based and imageless navigation, and between implant designs (Persona versus Vanguard TKA). Methodology. This was a retrospective review of a prospectively-maintained database of the initial 100 consecutive TKAs performed by a high volume surgeon using the ROSA® knee system. To determine the accuracy of component positioning, the immediate post-operative radiograph was reviewed and compared with the immediate pre-operative radiograph with regards to Joint Line Height, Tibial Slope, Patella Height (using the Insall-Salvati ratio) and Posterior Condylar Offset. Results. Mean age of patients undergoing ROSA TKA was 70 years (range, 55 to 95 years). Mean difference in joint line height between pre and post-operative radiographs was 0.2mm (range −1.5 to +1.8mm, p<0.05), posterior condylar offset mean change 0.16mm (range −1.4 to +1.3mm, p<0.05), tibial slope mean change 0.1 degrees (p<0.05) and patella height mean change 0.02 (range −0.1 to +0.1 p<0.05). No significant differences were found between imageless and image-based groups, or between implant designs (Persona versus Vanguard). Conclusion. This study validates the use of the ROSA® knee system in accurately restoring Joint Line Height, Patella Height and Posterior Condylar Offset


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 69 - 69
7 Aug 2023
Kumar A Stevens S Jonas S White S Agarwal S
Full Access

Abstract. Introduction. Isolated patellofemoral joint(PFJ) osteoarthritis affects approximately 10% of patients aged over 40 years and treatment remains controversial. Our aim was to evaluate long term functional and radiological outcomes following PFJ arthorplasty with the Femoro Patella Vialli (FPV) prosthesis as this evidence is lacking in literature. Methodology. A retrospective review of prospectively collected PROMS in patients undergoing Patellofemoral arthroplasty. Single centre trial. Between 2004 and 2008, 101 FPV patellofemoral arthroplasties were performed in 80 patients with isolated patellofemoral joint osteoarthritis. Data was collected as a part of routine follow-up for up to 6 years and additional long term data was collected at 16 years. Results. At 6 year follow up the mean OKS was 29 and by 16 year follow up it was 26 which was not a statistically significant drop. 22 patients (29 knees) had died, 32 (32%) had been revised, 25 to total knee replacement using primary arthroplasty components. Mean OKS in the revised group was 27 which was not a statistically significant difference when compared to the unrevised group. Mean time to revision was 4 years. The cumulative survival analysis of the FPV implant was 76% at 5 years, 64% at 10 years. Conclusion. Our findings suggest the FPV patellofemoral prosthesis provides good pain relief and clinical outcomes however, the survivorship for this particular implant maybe lower as compared to the available literature. Patient reported outcomes are maintained over the implant life and are no worse once revised implying a staged approach to arthroplasty is reasonable


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 761 - 765
1 Jun 2007
Barnett AJ Gardner ROE Lankester BJA Wakeley CJ Eldridge JDJ

We retrospectively analysed the MR scans of 25 patients with patellofemoral dysplasia and ten control subjects, to assess whether there was any change in the morphology of the patella along its vertical length. Ratios were calculated comparing the size of the cartilaginous and subchondral osseous surfaces of the lateral and medial facets. We also classified the morphology using the scoring systems of Baumgartl and Wiberg. There were 18 females and seven males with a mean age of 20.2 years (10 to 29) with dysplasia and two females and eight males with a mean age of 20.4 years (10 to 29) in the control group. In the patient group there was a significant difference in morphology from proximal to distal for the cartilaginous (Analysis of variance (ANOVA) p = 0.004) and subchondral osseous surfaces (ANOVA, p = 0.002). In the control group there was no significant difference for either the cartilaginous (ANOVA, p = 0.391) or the subchondral osseous surface (ANOVA, p = 0.526). Our study has shown that in the dysplastic patellofemoral articulation the medial facet of the patella becomes smaller in relation to the lateral facet from proximal to distal. MRI is needed to define clearly the cartilaginous and osseous morphology of the patella before surgery is considered for patients with patellofemoral dysplasia


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 40 - 47
1 Jul 2019
Sporer S MacLean L Burger A Moric M

Aims. Our intention was to investigate if the highly porous biological fixation surfaces of a new 3D-printed total knee arthroplasty (TKA) achieved adequate fixation of the tibial and patellar components to the underlying bone. Patients and Methods. A total of 29 patients undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate and metal-backed patella. Patient-reported outcomes measures were recorded and implant migration was assessed using radiostereometric analysis. Results. Patient function significantly improved by three months postoperatively (p < 0.001). Mean difference in maximum total point motion between 12 and 24 months was 0.021 mm (-0.265 to 0.572) for the tibial implant and 0.089 mm (-0.337 to 0.758) for the patellar implant. The rate of tibial and patellar migration was largest over the first six postoperative weeks, with no changes in mean tibia migration occurring after six months, and no changes in mean patellar migration occurring after six weeks. One patellar component showed a rapid rate of migration between 12 and 24 months. Conclusion. Biological fixation appears to occur reliably on the highly porous implant surface of the tibial baseplate and metal-backed patellar component. Rapid migration after 12 months was measured for one patellar component. Further investigation is required to assess the long-term stability of the 3D-printed components and to determine if the high-migrating components achieve fixation. Cite this article: Bone Joint J 2019;101-B(7 Supple C):40–47


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 3 | Pages 344 - 350
1 Mar 2009
Luyckx T Didden K Vandenneucker H Labey L Innocenti B Bellemans J

The purpose of this study was to test the hypothesis that patella alta leads to a less favourable situation in terms of patellofemoral contact force, contact area and contact pressure than the normal patellar position, and thereby gives rise to anterior knee pain. A dynamic knee simulator system based on the Oxford rig and allowing six degrees of freedom was adapted in order to simulate and record the dynamic loads during a knee squat from 30° to 120° flexion under physiological conditions. Five different configurations were studied, with variable predetermined patellar heights. The patellofemoral contact force increased with increasing knee flexion until contact occurred between the quadriceps tendon and the femoral trochlea, inducing load sharing. Patella alta caused a delay of this contact until deeper flexion. As a consequence, the maximal patellofemoral contact force and contact pressure increased significantly with increasing patellar height (p < 0.01). Patella alta was associated with the highest maximal patellofemoral contact force and contact pressure. When averaged across all flexion angles, a normal patellar position was associated with the lowest contact pressures. Our results indicate that there is a biomechanical reason for anterior knee pain in patients with patella alta


The Bone & Joint Journal
Vol. 98-B, Issue 4 | Pages 483 - 489
1 Apr 2016
Tigchelaar S Rooy JD Hannink G Koëter S van Kampen A Bongers E

Aim. Nail patella syndrome (NPS) is a skeletal dysplasia with patellofemoral dysfunction as a key symptom. We present the first in-depth radiological evaluation of the knee in a large series of NPS patients and describe the typical malformations. Patients and Methods. Conventional radiological examination of 95 skeletally mature patients with NPS was performed. Patellar morphology was classified according to the Wiberg classification as modified by Baumgartl and Ficat criteria, and trochlear shape was classified according to the Dejour classification. Results. Patellar aplasia was present in 4/90 (4%), and patellar hypoplasia in 77/90 (86%) of patients. The prevailing patellar shapes were type III, type IV and Hunter’s cap. No patellar shape genotype-phenotype association could be found. The malformations of the distal femur comprised shortening of the lateral femoral condyle in 46 out of 84 patients (55%), with a prominent anterior surface of the lateral femoral condyle in 47 out of 84 patients (56%) and a flat anterior surface of the medial femoral condyle in 78 out of 85 patients (92%). The trochlea was type A1 according to the Dejour classification in 79 out of 85 patients (93%). . Conclusion. An easily recognisable characteristic quartet of malformations consisting of patellar aplasiaor hypoplasia and the malformations of the distal femur was found in 22 out of 81 patients (27%), with the majority displaying at least three malformations. Take home message: The distinct malformations of the knee in nail patella syndrome are easily recognisable on conventional radiographs and lead to the correct interpretation of the aberrant morphology which is essential in the treatment of these patellofemoral disorders. Cite this article: Bone Joint J 2016;98-B:483–9


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 752 - 760
1 Jun 2007
Yamada Y Toritsuka Y Horibe S Sugamoto K Yoshikawa H Shino K

We used three-dimensional movement analysis by computer modelling of knee flexion from 0° to 50° in 14 knees in 12 patients with recurrent patellar dislocation and in 15 knees in ten normal control subjects to compare the in vivo three-dimensional movement of the patella. Flexion, tilt and spin of the patella were described in terms of rotation angles from 0°. The location of the patella and the tibial tubercle were evaluated using parameters expressed as percentage patellar shift and percentage tubercle shift. Patellar inclination to the femur was also measured and patellofemoral contact was qualitatively and quantitatively analysed. The patients had greater values of spin from 20° to 50°, while there were no statistically significant differences in flexion and tilt. The patients also had greater percentage patellar shift from 0° to 50°, percentage tubercle shift at 0° and 10° and patellar inclination from 0° to 50° with a smaller oval-shaped contact area from 20° to 50° moving downwards on the lateral facet. Patellar movement analysis using a three-dimensional computer model is useful to clearly demonstrate differences between patients with recurrent dislocation of the patella and normal control subjects


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 73 - 73
1 Mar 2012
Iranpour F Merican AM Hirschmann MT Cobb JP Amis AA
Full Access

Introduction. Differing descriptions of patellar motion relative to the femur have resulted from many in-vitro and in-vivo studies. The aim of this study was to examine the tracking behaviour of the patella. We hypothesized that patellar kinematics would correlate to the trochlear geometry. Method. Seven normal fresh-frozen knees were CT scanned and their kinematics with quadriceps loading was measured by an optical tracker system and calculated in relation to the previously-established femoral axes. CT scans were used to reliably define frames of reference for the femur, tibia and the patella. A novel trochlear axis was defined, between the centres of best-fit medial and lateral trochlear articular surfaces spheres. Results. The path of the centre of the patella was circular and uniplanar (RMS error 0.3mm) above 16°±3° knee flexion. The distal end of the median ridge of the patella entered the groove at 6° knee flexion, and the midpoint at 22°. This circle was aligned 6°±2° (mean± SD) from the femoral anatomical axis, 91°±3° from the epicondylar axis, and 88°±3° from the trochlear axis, in the coronal plane. In the transverse plane it was 91°±3° and 88°±3° from the epicondylar and trochlear axes. Manipulation of the data using a transformation matrix to the previously reported anatomic axis of the femur showed an initial medial and then lateral translation. Discussion. The motion path of the patella is dominantly circular in normal knees, when observed using a trochlea specific frame of reference. There is lateral translation in the last 16 degrees of extension, but in the rest of the range of motion, the patella motion path is on a single circular path with an RMS of less than 0.5mm. The two plane motion paths previously described can be replicated by a geometric transformation. Patella kinematics and patho-kinematics are more easily understood using this method


The Bone & Joint Journal
Vol. 106-B, Issue 3 | Pages 232 - 239
1 Mar 2024
Osmani HT Nicolaou N Anand S Gower J Metcalfe A McDonnell S

Aims

To identify unanswered questions about the prevention, diagnosis, treatment, and rehabilitation and delivery of care of first-time soft-tissue knee injuries (ligament injuries, patella dislocations, meniscal injuries, and articular cartilage) in children (aged 12 years and older) and adults.

Methods

The James Lind Alliance (JLA) methodology for Priority Setting Partnerships was followed. An initial survey invited patients and healthcare professionals from the UK to submit any uncertainties regarding soft-tissue knee injury prevention, diagnosis, treatment, and rehabilitation and delivery of care. Over 1,000 questions were received. From these, 74 questions (identifying common concerns) were formulated and checked against the best available evidence. An interim survey was then conducted and 27 questions were taken forward to the final workshop, held in January 2023, where they were discussed, ranked, and scored in multiple rounds of prioritization. This was conducted by healthcare professionals, patients, and carers.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1172 - 1177
1 Sep 2007
Benoit B Laflamme GY Laflamme GH Rouleau D Delisle J Morin B

We retrospectively reviewed the operative treatment carried out between 1988 and 1994 of eight patients with habitual patellar dislocation. In four the condition was bilateral. All patients had recurrent dislocation with severe functional disability. The surgical technique involved distal advancement of the patella by complete mobilisation of the patellar tendon, lateral release and advancement of vastus medialis obliquus. The long-term results were assessed radiologically, clinically and functionally using the Lysholm knee score, by an independent observer. The mean age at operation was 10.3 years (7 to 14) with a mean follow-up of 13.5 years (11 to 16). One patient required revision. At the latest follow-up, all patellae were stable and knees functional with a mean Lysholm knee score of 98 points (95 to 100). In those aged younger than ten years at operation there was a statistically significant improvement in the sulcus angle at the latest follow-up (Student’s t-test, p = 0.001). Two patients developed asymptomatic patella infera as a late complication. This technique offers a satisfactory treatment for the immature patient presenting with habitual patellar dislocation associated with patella alta. If performed early, we believe that remodelling of the shallow trochlea may occur, adding intrinsic patellofemoral stability


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 27 - 27
1 Oct 2018
Sporer S MacLean L Burger A
Full Access

Introduction. Uncemented highly porous titanium implants have been shown to promote osseointegration, and may result in a durable construct for total knee arthroplasty (TKA). Given the mixed results of uncemented TKA, it is important to evaluate the early stability for this product. The objective of the following study was to use radiostereometric analysis (RSA) to assess early fixation of a highly porous tibial baseplate and metal backed patella. Methods. Twenty-seven patients (mean age 64 years, 30% female) undergoing primary TKA consented to participate in this prospective cohort study. All patients received a highly porous tibial baseplate, a metal backed patella and tantalum RSA bone markers. Implant migration was assessed using model-based RSA at 1.5, 3, 6, 12 and 24 months post-operative. Patient reported outcome measures were captured using the same follow-up schedule, and compared to pre-operative measures. Results. There were no adverse events affecting implant fixation, and no revisions. Patient function significantly improved by 3 months post-operation (p < 0.001). The highest rate of tibia and patellar component migration occurred over the first six post-operative weeks, with minimal migration thereafter. Mean maximum total point motion (MTPM) at 24 months was 0.72 (SD 0.34) mm for the tibia, and 0.44 (SD 0.25) mm for the patella. Three tibia baseplates migrated more than 1 standard deviation greater than the mean at 24 months, and also had continuous migration (> 0.2mm of MTPM) in the second post-operative year. One patellar component showed a rapid rate of migration between 6 and 24 months, whereas all other patellar components appeared to stabilize. Conclusions. Osseointegration appears to occur on the highly porous implant surface of the tibia baseplate and metal backed patella, as evidenced by implant stability. Further follow-up is required to determine if clinical loosening will manifest in the continuously migrating implants


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 103 - 103
1 Jul 2012
Zourelidis C Mukhopadhyay S Kotwal R Williams R
Full Access

In recent years tribological development of knee replacement impants has beeen introduced with several benefits. However, concomitant problems were noticed following widespread use. High-flexion total knee replacement (PFC RPF DePuy) has been developed with a view to improve flexion and the design is expected to have a better patello-femoral biomechanics. However, high secondary patella resurfacing rate has been noticed in the current series. We have retrospectively reviewed 119 knees in 96 patients who underwent RPF knee replacement with selective patellar resurfacing from 2006 to 2010 by the senior author. 71 were performed without primary resurfacing while 48 in knees patella was resurfaced primarily due to significant symptomatic arthritic changes. Majority were females (57 versus 39 males). Average follow-up period was 37 (12-62) months. Twelve (16.9%) knees were subjected to secondary resurfacing due to continuing anterior knee pain. Average time from primary total knee replacement to secondary resurfacing was 18 months (8-35). Most of the patients were satisfied following the secondary resurfacing. Mean Oxford Knee Score in the group where the patella was resurfaced primarily was 33.1 (9-48), in the group where the patella was not resurfaced 32.8 (11-47), in the secondary resurfacing group 31.8 (14-43) and in the revision group 20.5 (16-25). RPF knee replacements in our series have a considerably higher rate of secondary patellar resurfacing as compared with published literature. We recommend primary patellar resurfacing of all RPF knee replacements to avoid this problem. Further analysis of the prosthetic design would be beneficial in relation to clinical outcome. No of patients-96. Total no of knee-118. Av age-66.5. Females-57. Males-39. Patella not resurfaced- 73. Resurfaced-45. Revised-10(13.7%). Revision to TKR (TC3) for different reason-3(2.54%). Average time from primary to secondary resurfacing-


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 81 - 81
1 Jul 2012
Haughton D Fountain J Barton-Hanson N
Full Access

Purpose. Investigate the functional outcome of medial patellofemoral ligament (MPFL) surgery for patella instability. Compare functional outcome of direct MPFL repair and reconstruction using hamstring graft. Methods. All patients that underwent MPFL surgery for patella instability between 2007-2010 were retrospectively identified from operative records. Patients were divided based on whether they underwent direct repair of MPFL, or reconstruction using hamstring graft. The Kujala scoring questionnaire for patellofemoral disorders (max score 100) was used to assess their functional outcome following surgery. Results. 33 patients were identified, 11 were not suitable for inclusion in the study. The remaining 22 patients had a total of 25 operations for patella stabilisation (3 bilateral). Average age of patient at time of surgery was 21 (15-33), 15 male and 7 female. 17 had direct repair of MPFL, 8 had reconstruction using hamstring graft. Of the 8 reconstructions 6 were primary procedures and 2 were for failed direct repair due to further traumatic injury. Mean follow-up period was 17 months (6-43). Mean Kujala score overall 91.6, mean score for reconstruction group 93.2, direct repair score 90.7. Total number of further patella dislocations in the repair group was 1/17 (5.9%). No patients in the reconstruction group reported any further patella dislocations following their surgery. Conclusion. Both direct repair and reconstruction of MPFL for patella instability demonstrate high functional outcome at short/mid-term follow up. Our high success rate in direct MPFL repair, good functional outcome and low re-dislocation rate is better than that quoted in the current literature


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 6 | Pages 746 - 751
1 Jun 2007
Yamada Y Toritsuka Y Yoshikawa H Sugamoto K Horibe S Shino K

We investigated the three-dimensional morphological differences of the articular surface of the femoral trochlea in patients with recurrent dislocation of the patella and a normal control group using three-dimensional computer models. There were 12 patients (12 knees) and ten control subjects (ten knees). Three-dimensional computer models of the femur, including the articular cartilage, were created. Evaluation was performed on the shape of the articular surface, focused on its convexity, and the proximal and mediolateral distribution of the articular cartilage of the femoral trochlea. The extent of any convexity, and the proximal distribution of the articular cartilage, expressed as the height, were shown by the angles about the transepicondylar axis. The mediolateral distribution of the articular cartilage was assessed by the location of the medial and lateral borders of the articular cartilage. The mean extent of convexity was 24.9° . sd. 6.7° for patients and 11.9° . sd. 3.6° for the control group (p < 0.001). The mean height of the articular cartilage was 91.3° . sd. 8.3° for the patients and 83.3° . sd. 7.7° for the control group (p = 0.03), suggesting a wider convex trochlea in the patients with recurrent dislocation of the patella caused by the proximally-extended convex area. The lateral border of the articular cartilage of the trochlea in the patients was more laterally located than in the control group. Our findings therefore quantitatively demonstrated differences in the shape and distribution of the articular cartilage on the femoral trochlea between patients with dislocation of the patella and normal subjects


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 80 - 80
1 Jul 2012
Wong F Przedlacka A Tan HB Allen P
Full Access

PURPOSES. Previous studies on patella-femoral morphology have suggested patella maltracking plays an important part in the aetiology but there had been no studies correlating maltracking with articular cartilage change. METHODS. We studied 147 consecutive patients (294 knees) aged between 10 and 63 presenting with anterior knee pain. All underwent MRI tracking scan of their knees as part of the routine investigations. We analysed the prevalence of maltracking with respect to gender, laterality and age groups, as well as patello-femoral articular cartilage changes. RESULTS. 52% of patients were found to have maltracking, of which 75% were bilateral. Furthermore, 66% of patients with maltracking had radiological evidence of patellar articular cartilage changes, corresponding to 61% of 294 knees examined. While majority of these occur at lateral facet, a proportion of medial facet changes (16%) is also seen. More significantly, while 25% of knees from patients with maltracking under the age of 20 are found to have changes on the patella cartilage, this increases to 93% by the age of 50 or above, with step-wise increment per decade of age (p<0.01). CONCLUSION. Our results demonstrate a strong correlation between anterior knee pain symptoms, patella maltracking and changes in patello-femoral joint cartilages of varying severity. This has implications on the management of these patients and would suggest early correction of maltracking is indicated to prevent deterioration in the patello-femoral joint


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 965 - 970
1 Nov 1998
Meister K Cobb A Bentley G

Between 1989 and 1993 we implanted a matrix support prosthesis made of carbon fibre for the treatment of chronic painful articular defects of the patella in 27 patients. The mean period of follow-up was 33 months (11 to 54) with clinical and arthroscopic evaluation of the implant. Overall, there were four excellent, three good, seven fair and 13 poor results. Nine patients subsequently had a patellectomy for persistent pain at a mean of 27 months after surgery (14 to 47). The mean visual analogue pain scores in those who retained their patella were 7.6 before operation and 5.5 at the time of the latest follow-up. Patient satisfaction for the entire group was 41%. There appeared to be good incorporation of the prosthesis and a satisfactory ingrowth of fibrocartilage, but the poor results in 48% and low patient satisfaction discourage us from recommending the procedure for lesions of the articular cartilage of the patella. The consistent seeding of the joint with carbon-fibre debris and a histiocytic giant-cell reaction in the synovium are also a cause for concern


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 675 - 678
1 Jul 2003
Muoneke HE Khan AM Giannikas KA Hägglund E Dunningham TH

Out of a total of 623 patients who, over a ten-year period, underwent primary total knee replacement (TKR) without patellar resurfacing, 20 underwent secondary resurfacing for chronic anterior knee pain. They were evaluated pre- and postoperatively using the clinical and radiological American Knee Society score. The mean follow-up was 36.1 months (12 to 104). The mean knee score improved from 46.7 to 62.2 points and the mean functional score from 44.7 to 52.2 points. Only 44.4% of the patients, however, reported some improvement; the remainder reported no change or deterioration. The radiographic alignment of the TKR did not influence the outcome of secondary resurfacing of the patella. Complications were noted in six of the 20 patients including fracture and instability of the patella and loss of movement. Anterior knee pain after TKR remains difficult to manage. Secondary resurfacing of the patella is not advocated in all patients since it may increase patient dissatisfaction and hasten revision


The Bone & Joint Journal
Vol. 96-B, Issue 4 | Pages 473 - 478
1 Apr 2014
van Jonbergen HPW Scholtes VAB Poolman RW

In the absence of patellar resurfacing, we have previously shown that the use of electrocautery around the margin of the patella improved the one-year clinical outcome of total knee replacement (TKR). In this prospective randomised study we compared the mean 3.7 year (1.1 to 4.2) clinical outcomes of 300 TKRs performed with and without electrocautery of the patellar rim: this is an update of a previous report. The overall prevalence of anterior knee pain was 32% (95% confidence intervals [CI] 26 to 39), and 26% (95% CI 18 to 35) in the intervention group compared with 38% (95% CI 29 to 48) in the control group (chi-squared test; p = 0.06). The overall prevalence of anterior knee pain remained unchanged between the one-year and 3.7 year follow-up (chi-squared test; p = 0.12). The mean total Western Ontario McMasters Universities Osteoarthritis Indices and the American Knee Society knee and function scores at 3.7 years’ follow-up were similar in the intervention and control groups (repeated measures analysis of variance p = 0.43, p = 0.09 and p = 0.59, respectively). There were no complications. A total of ten patients (intervention group three, control group seven) required secondary patellar resurfacing after the first year. Our study suggests that the improved clinical outcome with electrocautery denervation compared with no electrocautery is not maintained at a mean of 3.7 years’ follow-up. Cite this article: Bone Joint J 2014;96-B:473–8