Advertisement for orthosearch.org.uk
Results 1 - 20 of 319
Results per page:
Bone & Joint Open
Vol. 5, Issue 10 | Pages 904 - 910
18 Oct 2024
Bergman EM Mulligan EP Patel RM Wells J

Aims. The Single Assessment Numerical Evalution (SANE) score is a pragmatic alternative to longer patient-reported outcome measures (PROMs). The purpose of this study was to investigate the concurrent validity of the SANE and hip-specific PROMs in a generalized population of patients with hip pain at a single timepoint upon initial visit with an orthopaedic surgeon who is a hip preservation specialist. We hypothesized that SANE would have a strong correlation with the 12-question International Hip Outcome Tool (iHOT)-12, the Hip Outcome Score (HOS), and the Hip disability and Osteoarthritis Outcome Score (HOOS), providing evidence for concurrent validity of the SANE and hip-specific outcome measures in patients with hip pain. Methods. This study was a cross-sectional retrospective database analysis at a single timepoint. Data were collected from 2,782 patients at initial evaluation with a hip preservation specialist using the iHOT-12, HOS, HOOS, and SANE. Outcome scores were retrospectively analyzed using Pearson correlation coefficients. Results. Mean raw scores were iHOT-12 67.01 (SD 29.52), HOS 58.42 (SD 26.26), HOOS 86.85 (SD 32.94), and SANE 49.60 (SD 27.92). SANE was moderately correlated with the iHOT-12 (r = -0.4; 95% CI -0.35 to -0.44; p < 0.001), HOS (r = 0.57; 95% CI 0.53 to 0.60; p < 0.001), and HOOS (r = -0.55; 95% CI -0.51 to -0.58; p < 0.001). The iHOT-12 and HOOS were recorded as a lower score, indicating better function, which accounts for the negative r values. Conclusion. This study was the first to investigate the relationship between the SANE and the iHOT-12, HOS, and HOOS in a population of patients with hip pain at the initial evaluation with an orthopaedic surgeon, and found moderate correlation between SANE and the iHOT-12, HOS, and HOOS. The SANE may be a pragmatic alternative for clinical benchmarking in a general population of patients with hip pain. The construct validity of the SANE should be questioned compared to legacy measures whose content validity has been more rigorously investigated. Cite this article: Bone Jt Open 2024;5(10):904–910


Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims. The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales. Methods. We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID). Results. The CAT algorithms accurately estimated 12-item questionnaire scores from between four and nine items. Scores followed a very similar distribution between CAT and full-length assessments, with the mean score difference ranging from 0.03 to 0.26 out of 48 points. Pearson’s correlation coefficient and ICC were 0.98 for each 12-item scale and 0.95 or higher for the OES subscales. In over 95% of cases, a patient’s CAT score was within five points of the full-length questionnaire score for each 12-item questionnaire. Conclusion. Oxford Hip Score, Oxford Knee Score, Oxford Shoulder Score, and Oxford Elbow Score (including separate subscale scores) CATs all markedly reduce the burden of items to be completed without sacrificing score accuracy. Cite this article: Bone Jt Open 2022;3(10):786–794


Bone & Joint Research
Vol. 10, Issue 12 | Pages 830 - 839
15 Dec 2021
Robertson G Wallace R Simpson AHRW Dawson SP

Aims. Assessment of bone mineral density (BMD) with dual-energy X-ray absorptiometry (DXA) is a well-established clinical technique, but it is not available in the acute trauma setting. Thus, it cannot provide a preoperative estimation of BMD to help guide the technique of fracture fixation. Alternative methods that have been suggested for assessing BMD include: 1) cortical measures, such as cortical ratios and combined cortical scores; and 2) aluminium grading systems from preoperative digital radiographs. However, limited research has been performed in this area to validate the different methods. The aim of this study was to investigate the evaluation of BMD from digital radiographs by comparing various methods against DXA scanning. Methods. A total of 54 patients with distal radial fractures were included in the study. Each underwent posteroanterior (PA) and lateral radiographs of the injured wrist with an aluminium step wedge. Overall 27 patients underwent routine DXA scanning of the hip and lumbar spine, with 13 undergoing additional DXA scanning of the uninjured forearm. Analysis of radiographs was performed on ImageJ and Matlab with calculations of cortical measures, cortical indices, combined cortical scores, and aluminium equivalent grading. Results. Cortical measures showed varying correlations with the forearm DXA results (range: Pearson correlation coefficient (r) = 0.343 (p = 0.251) to r = 0.521 (p = 0.068)), with none showing statistically significant correlations. Aluminium equivalent grading showed statistically significant correlations with the forearm DXA of the corresponding region of interest (p < 0.017). Conclusion. Cortical measures, cortical indices, and combined cortical scores did not show a statistically significant correlation to forearm DXA measures. Aluminium-equivalent is an easily applicable method for estimation of BMD from digital radiographs in the preoperative setting. Cite this article: Bone Joint Res 2021;10(12):830–839


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 715 - 720
1 Jun 2022
Dunsmuir RA Nisar S Cruickshank JA Loughenbury PR

Aims. The aim of the study was to determine if there was a direct correlation between the pain and disability experienced by patients and size of their disc prolapse, measured by the disc’s cross-sectional area on T2 axial MRI scans. Methods. Patients were asked to prospectively complete visual analogue scale (VAS) and Oswestry Disability Index (ODI) scores on the day of their MRI scan. All patients with primary disc herniation were included. Exclusion criteria included recurrent disc herniation, cauda equina syndrome, or any other associated spinal pathology. T2 weighted MRI scans were reviewed on picture archiving and communications software. The T2 axial image showing the disc protrusion with the largest cross sectional area was used for measurements. The area of the disc and canal were measured at this level. The size of the disc was measured as a percentage of the cross-sectional area of the spinal canal on the chosen image. The VAS leg pain and ODI scores were each correlated with the size of the disc using the Pearson correlation coefficient (PCC). Intraobserver reliability for MRI measurement was assessed using the interclass correlation coefficient (ICC). We assessed if the position of the disc prolapse (central, lateral recess, or foraminal) altered the symptoms described by the patient. The VAS and ODI scores from central and lateral recess disc prolapses were compared. Results. A total of 56 patients (mean age 41.1 years (22.8 to 70.3)) were included. A high degree of intraobserver reliability was observed for MRI measurement: single measure ICC was 0.99 (95% confidence interval (CI) from 0.97 to 0.99 (p < 0.001)). The PCC comparing VAS leg scores with canal occupancy for herniated disc was 0.056. The PCC comparing ODI for herniated disc was 0.070. We found 13 disc prolapses centrally and 43 lateral recess prolapses. There were no foraminal prolapses in this group. The position of the prolapse was not found to be related to the mean VAS score or ODI experienced by the patients (VAS, p = 0.251; ODI, p = 0.093). Conclusion. The results of the statistical analysis show that there is no direct correlation between the size or position of the disc prolapse and a patient’s symptoms. The symptoms experienced by patients should be the primary concern in deciding to perform discectomy. Cite this article: Bone Joint J 2022;104-B(6):715–720


Bone & Joint Open
Vol. 4, Issue 5 | Pages 363 - 369
22 May 2023
Amen J Perkins O Cadwgan J Cooke SJ Kafchitsas K Kokkinakis M

Aims. Reimers migration percentage (MP) is a key measure to inform decision-making around the management of hip displacement in cerebral palsy (CP). The aim of this study is to assess validity and inter- and intra-rater reliability of a novel method of measuring MP using a smart phone app (HipScreen (HS) app). Methods. A total of 20 pelvis radiographs (40 hips) were used to measure MP by using the HS app. Measurements were performed by five different members of the multidisciplinary team, with varying levels of expertise in MP measurement. The same measurements were repeated two weeks later. A senior orthopaedic surgeon measured the MP on picture archiving and communication system (PACS) as the gold standard and repeated the measurements using HS app. Pearson’s correlation coefficient (r) was used to compare PACS measurements and all HS app measurements and assess validity. Intraclass correlation coefficient (ICC) was used to assess intra- and inter-rater reliability. Results. All HS app measurements (from 5 raters at week 0 and week 2 and PACS rater) showed highly significant correlation with the PACS measurements (p < 0.001). Pearson’s correlation coefficient (r) was constantly over 0.9, suggesting high validity. Correlation of all HS app measures from different raters to each other was significant with r > 0.874 and p < 0.001, which also confirms high validity. Both inter- and intra-rater reliability were excellent with ICC > 0.9. In a 95% confidence interval for repeated measurements, the deviation of each specific measurement was less than 4% MP for single measurer and 5% for different measurers. Conclusion. The HS app provides a valid method to measure hip MP in CP, with excellent inter- and intra-rater reliability across different medical and allied health specialties. This can be used in hip surveillance programmes by interdisciplinary measurers. Cite this article: Bone Jt Open 2023;4(5):363–369


Bone & Joint Research
Vol. 10, Issue 12 | Pages 820 - 829
15 Dec 2021
Schmidutz F Schopf C Yan SG Ahrend M Ihle C Sprecher C

Aims. The distal radius is a major site of osteoporotic bone loss resulting in a high risk of fragility fracture. This study evaluated the capability of a cortical index (CI) at the distal radius to predict the local bone mineral density (BMD). Methods. A total of 54 human cadaver forearms (ten singles, 22 pairs) (19 to 90 years) were systematically assessed by clinical radiograph (XR), dual-energy X-ray absorptiometry (DXA), CT, as well as high-resolution peripheral quantitative CT (HR-pQCT). Cortical bone thickness (CBT) of the distal radius was measured on XR and CT scans, and two cortical indices mean average (CBTavg) and gauge (CBTg) were determined. These cortical indices were compared to the BMD of the distal radius determined by DXA (areal BMD (aBMD)) and HR-pQCT (volumetric BMD (vBMD)). Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC) were used to compare the results and degree of reliability. Results. The CBT could accurately be determined on XRs and highly correlated to those determined on CT scans (r = 0.87 to 0.93). The CBTavg index of the XRs significantly correlated with the BMD measured by DXA (r = 0.78) and HR-pQCT (r = 0.63), as did the CBTg index with the DXA (r = 0.55) and HR-pQCT (r = 0.64) (all p < 0.001). A high correlation of the BMD and CBT was observed between paired specimens (r = 0.79 to 0.96). The intra- and inter-rater reliability was excellent (ICC 0.79 to 0.92). Conclusion. The cortical index (CBTavg) at the distal radius shows a close correlation to the local BMD. It thus can serve as an initial screening tool to estimate the local bone quality if quantitative BMD measurements are unavailable, and enhance decision-making in acute settings on fracture management or further osteoporosis screening. Cite this article: Bone Joint Res 2021;10(12):820–829


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 91 - 91
4 Apr 2023
ÇİL E Subaşı F Gökçek G Şerif T Şaylı U
Full Access

Recently, several smartphone applications (apps) have been developed and validated for ankle ROM measurement tools like the universal goniometer. This is the first innovative study introduces a new smartphone application to measure ankle joint ROM as a remote solution. This study aimed to assess the correlation between smartphone ROM and universal goniometer measurements, and also report the evaluation of the DijiA app by users. The study included 22 healthy university students (14F/8M; 20.68±1.72 years) admitted to Yeditepe University. Fourty four feet was measured by both the universal goniometer (UG) and DijiA app. The datas were analyzed through using the intraclass correlation coefficient (ICC). The DijiA app was evaluated by usability testing with representative users. Pearson correlation coefficient test showed moderate correlation between the DijiA and UG for dorsiflexion (DF) and plantar flexion (PF) measurements (Pearson correlation coefficient: r=0.323, for DF; r=0.435 for PF 95% confidence interval). The application usability was found as high with 76.5 average score and users liked it. The DijiA app may be a more convenient and easy way to measure ankle DF and PF-ROM than UG. It can be used to evaluate ROM in clinical practice or home using as a personal smartphone


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 246 - 246
1 Jul 2011
Kuzyk PRT Davies JE Schemitsch EH
Full Access

Purpose: The purpose of this study was to relate the extent of reaming to bone formation occurring around a critical sized defect in the tibia. Method: Eleven canines were allocated into 2 groups: empty (N=5) or iliac crest autograft (N=6). All tibiae were reamed to 7.0 mm and fixed with a 6.5 mm statically locked intramedullary nail after creation of an 8.0 mm diaphyseal defect. The extent of reaming of the canal was dependent on the cross-sectional area of the tibia as all tibiae were reamed to 7.0 mm. Fluorescent markers were given at different times: calcein green (6 weeks), xylenol orange (9 weeks), and tetracycline (11 and 14 weeks). Animals were sacrificed at 15 weeks and perfused with a barium compound. Radiography, Micro CT, brightfield microscopy and fluorescent microscopy were used for analysis. Results: Bone and vasculature volume within the defect were reported as a percentage of the total volume of the defect. Linear regression analysis of percent bone volume (dependent variable) and canal area (independent variable) provided a Pearson correlation coefficient of 0.925 (p=0.025) for the empty group and 0.244 (p=0.641) for the autograft group. Linear regression analysis of percent vasculature volume (dependent variable) and canal area (independent variable) provided a Pearson correlation coefficient of 0.784 (p=0.117) for the empty group and −0.146 (p=0.783) for the autograft group. Bone formation at osteotomy sites was defined as the distance from the original osteotomy site to the tip of newly formed bone. Linear regression analysis of bone formation at the osteotomy sites (dependent variable) and canal area (independent variable) provided a Pearson correlation coefficient of 0.132 (p=0.832) for the empty group and −0.937 (p=0.006) for the autograft group. Bone formation rates were reported as the distance between the fluorescent labels. Bone formation rate was less within the endosteum, cortex and periosteum with extensive reaming in empty samples. Conclusion: Our results suggest that the acute management of tibia fractures with bone defects should involve limited reaming. This does not apply when the defect is autografted. Limited reaming may be defined by the cross-sectional area of the tibia in ratio to that of the reamer


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_11 | Pages 1 - 1
1 Aug 2018
Shimmin A
Full Access

A total hip replacement (THR) patient's spinopelvic mobility might predispose them to an increased risk of impingement, instability and edge-loading. This risk can be minimised by considering their preoperative movement during planning of component alignment. However, the question of whether the preoperative, arthritic motion is representative of the postoperative mobility has been raised. We aimed to determine the change in functional pelvic tilt in a series of THR patients at one-year. Four-hundred and eleven patients had their pelvic tilt and lumbar lordotic angle (LLA) measured in the standing and flexed-seated (position when patients initiate rising from a seat) positions as part of routine planning for THR. All measurements were performed on lateral radiographs. At 12-months postoperatively, the same two lateral images were taken and pelvic tilt measured. Pearson correlation was used to investigate the linear relationship between pre-and post-op pelvic tilt. Furthermore, a predictive model of post-op pelvic tilt was developed using machine learning algorithms. The model incorporating four preoperative inputs – standing pelvic tilt, seated pelvic tilt, standing LLA and seated LLA. In the standing position, there was a mean 2° posterior rotation after THR, with a maximum posterior change of 13°. The Pearson correlation coefficient between pre-and post-op standing pelvic tilt was 0.84. This prediction of post-op standing tilt improved to 0.91 when the three further inputs were incorporated to the predictive model. In the flexed-seated position, there was a mean 7° anterior rotation after THR, with a maximum anterior change of 45°. The Pearson correlation coefficient between pre-and post-op seated pelvic tilt was 0.54. This prediction of post-op seated tilt improved to 0.71 when the three further inputs were incorporated to the predictive model. The best predictor of post-operative spinopelvic mobility, is the patients pre-operative spinopelvic mobility, and this should routinely be measured when planning THR. The predictive model will continue to improve in accuracy as more data and more variables (contralateral hip pathology, pelvic incidence, age and gender) are incorporated into the model


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 92 - 92
1 Dec 2022
Gazendam A Schneider P Busse J Bhandari M Ghert M
Full Access

Functional outcomes are commonly reported in studies of musculoskeletal oncology patients undergoing limb salvage surgery; however, interpretation requires knowledge of the smallest amount of improvement that is important to patients – the minimally important difference (MID). We established the MIDs for the Musculoskeletal Tumor Society Rating Scale (MSTS) and Toronto Extremity Salvage Score (TESS) in patients with bone tumors undergoing lower limb salvage surgery. This study was a secondary analysis of the recently completed PARITY (Prophylactic Antibiotic Regimens in Tumor Surgery) study. This data was used to calculate: (1) the anchor-based MIDs using an overall function scale and a receiver operating curve analysis, and (2) the distribution-based MIDs based on one-half of the standard deviation of the change scores from baseline to 12-month follow-up, for both the MSTS and TESS. There were 591 patients available for analysis. The Pearson correlation coefficients for the association between changes in MSTS and TESS scores and changes in the external anchor scores were 0.71 and 0.57, indicating “high” and “moderate” correlation. Anchor-based MIDs were 12 points and 11 points for the MSTS and TESS, respectively. Distribution-based calculations yielded MIDs of 16-17 points for the MSTS and 14 points for the TESS. The current study proposes MID scores for both the MSTS and TESS outcome measures based on 591 patients with bone tumors undergoing lower extremity endoprosthetic reconstruction. These thresholds will optimize interpretation of the magnitude of treatment effects, which will enable shared decision-making with patients in trading off desirable and undesirable outcomes of alternative management strategies. We recommend anchor-based MIDs as they are grounded in changes in functional status that are meaningful to patients


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 868 - 873
1 Jul 2020
Yang G Dai Y Dong C Kang H Niu J Lin W Wang F

Aims. The purpose of this study was to explore the correlation between femoral torsion and morphology of the distal femoral condyle in patients with trochlear dysplasia and lateral patellar instability. Methods. A total of 90 patients (64 female, 26 male; mean age 22.1 years (SD 7.2)) with lateral patellar dislocation and trochlear dysplasia who were awaiting surgical treatment between January 2015 and June 2019 were retrospectively analyzed. All patients underwent CT scans of the lower limb to assess the femoral torsion and morphology of the distal femur. The femoral torsion at various levels was assessed using the a) femoral anteversion angle (FAA), b) proximal and distal anteversion angle, c) angle of the proximal femoral axis-anatomical epicondylar axis (PFA-AEA), and d) angle of the AEA–posterior condylar line (AEA-PCL). Representative measurements of distal condylar length were taken and parameters using the ratios of the bianterior condyle, biposterior condyle, bicondyle, anterolateral condyle, and anteromedial condyle were calculated and correlated with reference to the AEA, using the Pearson Correlation coefficient. Results. The femoral torsion had a strong correlation with distal condylar morphology. The FAA was significantly correlated with the ratio of the bianterior condyle (r = 0.355; p = 0.009), the AEA-PCL angle (r = 0.340; p = 0.001) and the ratio of the anterolateral condyle and lateral condyle (ALC-LC) (r = 0.309; p = 0.014). The PFA-AEA angle was also significantly correlated with the ratio of the bianterior condyle (r = 0.319; p = 0.008), the AEA-PCL angle (r = 0.231; p = 0.031), and the ratio of ALC-LC (r = 0.261; p = 0.034). In addition, the bianterior condyle ratio showed a significant correlation with the biposterior condyle ratio (r = -0.324; p = 0.027) and the AEA-PCL angle (r = 0.342; p = 0.021). Conclusion. Increased femoral torsion correlated with a prominent anterolateral condyle and a shorter posterolateral condyle compared with the medial condyle. The deformities of the anterior and posterior condyles are combined deformities rather than being isolated and individual deformities in patients with trochlear dysplasia and patella instability. Cite this article: Bone Joint J 2020;102-B(7):868–873


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 30 - 30
2 Jan 2024
Park H Kim R
Full Access

Glutamate regulates the expression of apoptosis-related genes and triggers the apoptosis of fibroblasts in rotator cuff tendons. Subacromial bursitis is always accompanied by symptomatic rotator cuff tear (RCT). However, no study has been reported on the presence of glutamate in subacromial bursa and on its involvement of shoulder pain in patients who had RCT. The purposes of this study were to determine whether the glutamate expression in subacromial bursa is associated with the presence of RCT and with the severity of shoulder pain accompanying RCT. Subacromial bursal tissues were harvested from patients who underwent arthroscopic rotator cuff tendon repair or glenoid labral repair with intact rotator cuff tendon. Glutamate tissue concentrations were measured, using a glutamate assay kit. Expressions of glutamate and its receptors in subacromial bursae were histologically determined. The sizes of RCT were determined by arthroscopic findings, using the DeOrio and Cofield classification. The severity of shoulder pain was determined, using visual analog scale (VAS). Any associations between glutamate concentrations and the size of RCT were evaluated, using logistic regression analysis. The correlation between glutamate concentrations and the severity of pain was determined, using the Pearson correlation coefficient. Differences with a probability <0.05 were considered statistically significant. Glutamate concentrations showed significant differences between the torn tendon group and the intact tendon group (P = 0.009). Concentrations of glutamate significantly increased according to increases in tear size (P < 0.001). In histological studies, the expressions of glutamate and of its ionotropic and metabotropic receptors have been confirmed in subacromial bursa. Glutamate concentrations were significantly correlated with pain on VAS (Rho=0.56 and P =0.01). The expression of glutamate in subacromial bursa is significantly associated with the presence of RCT and significantly correlated with its accompanying shoulder pain. Acknowledgements: This research was supported by the Basic Science Research Program, through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2015R1D1A3A01018955 and 2017R1D1A1B03035232)


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 68 - 68
1 May 2017
Masieri F Byles N
Full Access

Background. Microfracture (MF) and Autologous Chondrocyte Implantation (ACI) are used to repair symptomatic condylar cartilage defects (grade II-IV Outerbridge). Superiority of ACI to MF is still debated. The aim of the study was to conduct a systematic literature review, compare superiority of ACI versus MF in a meta-analysis and investigate the correlation between patient age and outcome of both treatments. Methods. Extended literature search was conducted (papers from January 2001 to present), looking at patient characteristics, pre- and post-operative scores and cartilage repair assessment evaluation. Methodological quality was verified through modified Coleman score and assessment bias. A fixed-effect meta-analysis was conducted, comparing post-operative standardised mean differences between ACI and MF. Pearson correlation coefficient between post-operative score and age was calculated against ACI and MF. Results. of 490 studies systematically analysed, 8 met the inclusion criteria, accounting for 255 patients treated with ACI and 259 with MF. Overall mean postoperative scores were 81.38±8.31 for ACI and 74.9±7.0 for MF, with no significant difference (p=0.13). The average modified Coleman score of the studies was 82.6, with low bias among them. The meta-analysis displayed an overall effect estimate of 0.3 favouring ACI treatment versus MF (95%CI=0.12–0.48, P=0.001). Significant heterogeneity was although observed (I2>70%). Pearson correlation coefficient calculated between mean post-operative score and mean age, surprisingly failed to indicate clear correlation for ACI (r=0.11) and MF (r=0.18) respectively. Conclusions. Minor statistically significant superiority of ACI intervention versus MF in knee cartilage repair was found, together with high levels of heterogeneity, halting the possibility to make full recommendation of ACI versus MF. Level of Evidence. Ia (systematic review and meta-analysis)


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


Abstract. Cranial cruciate ligament (CrCL) disease/rupture is a highly prevalent orthopaedic disease in dogs and common cause of pain, lameness, and secondary joint osteoarthritis (OA). Previous experiments investigating the role of glutamate receptors (GluR) in arthritic degeneration and pain revealed that OA biomarkers assessing early bone turnover and inflammation, including osteoprotegerin (OPG) and the receptor activator of nuclear factor kappa-B ligand (RANKL) are more likely to be influenced by glutamate signalling. Moreover, interleukin-6 (IL-6) has a complex and potentially bi directional (beneficial and detrimental) effect, and it is a critical mediator of arthritic pain, OA progression and joint destruction. Objectives. 1) to recruit dogs undergoing CrCL disease/rupture surgery and obtain discarded synovial fluid (SF) and serum/plasma (ethics approval, RCVS:2017/14/Alves); 2) to quantify the biomarkers listed above in the SF and serum/plasma by enzyme linked immunosorbent assay (ELISA); 3) to assess radiographic OA at the time of surgery and correlate it with the biomarkers and clinical findings. Methods. Abnova, Abcam and AMSBIO ELISA kits were tested using a validation protocol relating the standard curve to a dilution series of SF and serum/plasma (1× to 1/50×), with and without SF hyaluronidase treatment to evaluate linearity, specificity and optimal dilutions. Validated ELISA kits were used to measure [IL-6], glutamate [glu], [RANKL] and [OPG] in SF and serum/plasma. For each dog, CrCL disease pre-operative lameness scores were graded as: (1) mild, (2) moderate (easily visible), (3) marked (encumbered), (4) non-weightbearing lameness. Blinded OA scoring was performed on radiographs [15–60, normal-severe OA]. Results. canine population (n=14) was of various breeds, aged between 2–10 years and weighing 17.1–45.5Kg; 42.86% male; 57.14% female; 83.33% males and 62.5% females were neutered. Lameness scores varied from 1 and 4 (average 2.07±1.12) and radiographic OA scores from 18 and 36 (average 27.86±5.11). Individual correlations in concentrations with respect to age, weight, lameness score (1–4) and OA scores (15–60) were tested. SF [glu] and lameness score were inversely correlated with higher levels of lameness corresponding to lower SF [glu] (P=0.0141). SF [RANKL] inversely correlated with weight (P=0.0045) and lameness score (P=0.0135), and serum [RANKL] inversely correlated with weight (P=0.0437). There was also a negative correlation between SF and serum [OPG] and weight (P=0.0165 and P=0.0208, respectively). No other significant correlations were detected. Overall, [glu] and [IL-6] are increased in SF compared to serum/plasma, by 12.84 and 1.28, respectively, whereas all the remaining biomarkers are higher (2–3 times) in the serum/plasma compared to SF. Principal component analysis (PCA) and Pearson correlation coefficient matrix [IL-6/glu/RANKL/OPG] (n=7) showed SF [IL-6] correlates with SF [glu] (rs=0.64) and strong positive correlations between SF/serum [RANKL] and SF/serum [OPG] (rs 0.68–0.96). Conclusions. Dogs with CrCL disease show an association between the bone remodelling markers RANKL and OPG, and the inflammatory cytokine IL-6, and to a lesser extent SF [glu]. Therapeutics targeting bone remodelling, IL-6 or GluR/[glu] may be of interest for the management of OA in dogs. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 18 - 18
1 Oct 2014
Humphries T Baker M Lee LB Cole A Hughes-Lawson C Naylor B Michael A
Full Access

This study aimed to verify the accuracy of the DIERS Formetric Scan when assessing vertebral rotation of the apical vertebrae in Adolescent Idiopathic Scoliosis (A.I.S) patients, to determine whether the DIERS Formetric Scans can be used instead of or alongside radiographs when assessing A.I.S patients. Both the radiographs and the DIERS Formetric Scans of 60 Preoperative A.I.S patients. All patients included in our study had predominant thoracic curves using the Lenke classification method, Cobb angle range 33° – 85°. Each radiograph was categorised into groups according to the severity of Nash-Moe rotation score of the apical vertebrae. Three groups were formed Nash-Moe +1 (20 patients), Nash-Moe +2 (27 patients), Nash-Moe +3 (13 patients). Each result was then compared to the maximal rotation analysed by the DIERS Formetric Scan, which took place on the same day as the radiographs. The results were then assessed using a Pearson Correlation Coefficient and a One-Way ANOVA with Post-Hoc Tukey HSD Analysis. The Nash-Moe +1 Group scored a mean maximal rotation of 14.65° ±6.56 (11.82 – 17.48) (95% Confidence Interval), Nash-Moe +2 mean maximal rotation was 19.6° ±7.1 (16.92 – 22.28) and Nash-Moe +3 scored 21.53° ±8.9 (16.99 – 26.37). The Pearson Correlation Coefficient of this assessment was +0.342 (p value 0.07) demonstrating a weak positive correlation. The One-Way ANOVA analysis with Post-Hoc Tukey HSD analysis. The results of this analysis was an F value score of +4.115 (p Value 0.021) for the overall One-Way ANOVA test. The Post-Hoc Tukey HSD tests demonstrate that there is a statistical difference between Group 1 and Group 3 (p value 0.030) but there is no statistical difference between Group 1 and Group 2 (p value 0.068) as well as no statistical difference between Group 2 and Group 3 (p value 0.716). DIERS Formetric Scan assessment of vertebral rotation shows a positive correlation with the Nash-Moe method. This allows us to rely on the Formetric scans and thus a possible reduction in radiographs when assessing A.I.S, this reduces the exposure to ionising radiation in A.I.S patients


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 85 - 90
1 Jun 2020
Blevins JL Rao V Chiu Y Lyman S Westrich GH

Aims. The purpose of this investigation was to determine the relationship between height, weight, and sex with implant size in total knee arthroplasty (TKA) using a multivariate linear regression model and a Bayesian model. Methods. A retrospective review of an institutional registry was performed of primary TKAs performed between January 2005 and December 2016. Patient demographics including patient age, sex, height, weight, and body mass index (BMI) were obtained from registry and medical record review. In total, 8,100 primary TKAs were included. The mean age was 67.3 years (SD 9.5) with a mean BMI of 30.4 kg/m. 2. (SD 6.3). The TKAs were randomly split into a training cohort (n = 4,022) and a testing cohort (n = 4,078). A multivariate linear regression model was created on the training cohort and then applied to the testing cohort . A Bayesian model was created based on the frequencies of implant sizes in the training cohort. The model was then applied to the testing cohort to determine the accuracy of the model at 1%, 5%, and 10% tolerance of inaccuracy. Results. Height had a relatively strong correlation with implant size (femoral component anteroposterior (AP) Pearson correlation coefficient (ρ) = 0.73, p < 0.001; tibial component mediolateral (ML) ρ = 0.77, p < 0.001). Weight had a moderately strong correlation with implant size, (femoral component AP ρ = 0.46, p < 0.001; tibial ML ρ = 0.48, p < 0.001). There was a significant linear correlation with height, weight, and sex with implant size (femoral component R. 2. = 0.607, p < 0.001; tibial R. 2. = 0.695, p < 0.001). The Bayesian model showed high accuracy in predicting the range of required implant sizes (94.4% for the femur and 96.6% for the tibia) accepting a 5% risk of inaccuracy. Conclusion. Implant size was correlated with basic demographic variables including height, weight, and sex. The linear regression and Bayesian models accurately predicted required implant sizes across multiple manufacturers based on height, weight, and sex alone. These types of predictive models may help improve operating room and implant supply chain efficiency. Level of Evidence: Level IV. Cite this article: Bone Joint J 2020;102-B(6 Supple A):85–90


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 569 - 569
1 Dec 2013
Van Der Straeten C Witvrouw E Willems T Verstuyft L Victor J Bellemans J
Full Access

Background:. Recently a new version of the Knee Society Knee Scoring System has been developed, adapted to the lifestyle and activities of contemporary patients with a Total Knee Arthroplasty (TKA). It is subdivided into 4 domains including an Objective Knee Score, a Satisfaction Score, an Expectations Score and a Functional Activity Score. Before this scale can be used in non-English speaking populations, it has to be translated and validated for specific populations. The aim of this study was to translate and validate the New Knee Society Knee Scoring System (new KSS) for Dutch speaking populations. Materials and Methods:. A Dutch translation of the New KSS was established using a forward-backward translation protocol. 137 patients undergoing TKA were asked to complete the Dutch translation of the New KSS as well as the Dutch WOMAC, Dutch KOOS and the Dutch SF12. To determine the test-retest reliability, 53 patients were asked to fill out a second questionnaire with one-week interval. We tested the test-retest reliability of the subjective domains of the New KSS by assessing the intra-class coefficient and the Pearson correlation coefficient between the first and second questionnaires. Systematic differences between the first and second questionnaires were investigated with T-tests and non-parametric statistics. Internal consistency of the Dutch new KSS was evaluated with Cronbach's alpha. The construct validity of the Dutch New KSS was determined by comparing it to the Dutch WOMAC, Dutch KOOS and Dutch SF12 using Pearson correlation coefficients. Content validity was assessed by examining the distribution and the floor and ceiling effects of the Dutch version of the new KSS. Results:. The reliability of the Dutch translation of the New KSS proved excellent with an ICC ranging from 0.75 to 0.92 for single measures and from 0.85 to 0.96 for average measures in the different domains. Cronbach's alpha ranged from 0.86 to 0.96 indicating good to excellent internal consistency. Paired t-tests and non-parametric statistics revealed no significant differences between the first and second questionnaires while paired samples correlations were highly significant (p < 0.001). The Dutch New KSS correlated well with the Dutch WOMAC score (r = 0.81; p < 0.001), the Dutch KOOS (r = 0.77; p < 0.001), and the Dutch SF12 (r = 0.62; p < 0.001). Content validity was good with a normal distribution of the calculated scores and absence of floor or ceiling effects. Conclusions:. The validation procedure demonstrated that the proposed Dutch version of the New Knee Society Knee Scoring System is a reliable and valid instrument for evaluating symptoms, function, expectations and satisfaction after TKA in Dutch speaking patients


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_4 | Pages 10 - 10
1 Mar 2020
Place Z Shalaby H McKinley J
Full Access

We report a cost-effectiveness analysis of Primary Total Ankle Replacements (TAR). In addition, we looked for factors that could be predictors of increased gain in Quality-Adjusted Life Years (QALYs). Pre-operative and six-month post-operative data for TAR was obtained over seven-and-a-half-years in NHS Lothian. The EuroQol general health questionnaire (EQ-5D-3L) measured health-related Quality of Life and the Manchester-Oxford Foot Questionnaire (MOXFQ) measured joint function. Predictors, tested for significance with QALYs gained, were pre-operative scores and demographic data including age, gender, BMI and Deprivation category. Continuous variables were assessed with Pearson correlation coefficients, Deprivation and BMI categories with Boxplots and gender with the Mann-Whitney U test. The 74-patient cohort [Mean age 68.03 (SD 8.61), 60.8% male] had 49% classed as obese or higher. Cost per QALY gained was £3841, rising to £9202 when annual 3.5% reduction in health gains and 1.9% revision rates were included. Lower pre-operative EQ-5D-3L index correlated significantly with increased QALYs gained (p <0.01), all other predictors returned insignificant results (p >0.05). Primary TAR has proven very cost-effective in treating end-stage ankle arthritis. Pre-operative EQ-5D-3L is the most promising predictor of QALYs gained identified


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2011
Deep K Willcox N Smith B Deakin A
Full Access

It is generally accepted that Hip-Knee-Ankle (long-leg) radiographs are a good measurement tool for biomechanical axis of the knee and they have been used as the outcome measure for many studies. Most of the surgeons recommend having pre operative and post operative long leg radiographs for total knee replacement surgery, although practice is not as common. We studied the biomechanical axis on long-leg films and compared it with computer navigation. The objectives were to find out repeatability of measurements of biomechanical axis with inter observer readings on long leg radiographs and to compare biomechanical axis measurements with Navigation values obtained during total knee replacement surgery. Our institution routinely uses long-leg radiographs for total knee replacement (TKR) surgery both pre- and post-operatively. A series of 209 patients who had navigated TKR between Jan 2007 and 2008 were selected. Stryker and Orthopilot systems for navigation were used. The intra-operative biomechanical axis measurements from the computer navigation files both pre-and post- implant were recorded. The long leg films were measured with a defined protocol from the digital images on PACS system. Centre of the head of femur was taken as the upper point. For the knee centre the midpoint of a line joining the distal femoral notch centre and upper tibia was used. For the ankle centre midpoint of the upper talar margin was used. An angle between the three points represented the radiological biomechanical axis. To investigate inter-observer error, two observers measured the pre- and post-operative biomechanical axis on long leg radiographs independently on 57 patients. For the inter-observer measurements on 57 patients, the intraclass correlation coefficient was 0.99 for pre-operative radiographs and 0.98 for post-operative radiographs. Maximum difference between the two observers was 2° in four cases. All other cases showed the same readings or 1° difference. There was a strong correlation, which was statistically significant, between the pre-operative radiographic and navigated measurements with Pearson correlation coefficient of 0.810 (p< 0.001). The maximum difference between the radiographic and navigated measurement was 24 degrees. The relationship between the postoperative measurements was weaker but statistically significant with Pearson correlation coefficient of 0.323 (p< 0.001). The maximum difference between the two methods of measurement was larger 15.5. It can be concluded from this study that biomechanical axis on a long leg radiograph is a repeatable measure with good inter-observer correlation. Although it is statistically significantly correlated with navigated readings, the absolute values may be different with both the methods. This raises the question on the reliability of long leg radiographs for the prediction of true biomechanical axis. Most of the larger value differences had a fixed flexion deformities (9 – 45 degrees). This can affect the readings on the long leg radiographs and make the deformity look either smaller or bigger. Also as our knee kinematic study has proven that the deformity does not remain the same in flexion as it was in extended knee that could also account for the difference in the readings. Other reasons for difference in the pre operative readings could be weight bearing status and surgical opening of the joint before taking the pre operative biomechanical axis measurements. Difference in the post operative readings could be attributed to weight bearing status, time length between navigation and radiographic measurements (6–12 wks), scarring of the soft tissues in the time and flexed posture of knee in the early post operative period