Technology within medicine has great potential to bring about more accessible, efficient, and a higher quality delivery of care. Paediatric supracondylar fractures are the most common elbow fracture in children and at our institution often have high rates of unnecessary long term clinical follow-up, leading to an inefficient use of healthcare and patient resources. This study aims to evaluate patient and clinical factors that significantly predict necessity for further clinical visits following closed reduction and
There is no agreement as to the superiority or specific indications for cast treatment,
Paediatric supracondylar fractures are the most common elbow fracture in children, and is associated with an 11% incidence of neurologic injury. The goal of this study is to investigate the natural history and outcome of motor nerve recovery following closed reduction and
Introduction. External fixators are attached to bones with
To compare 24-month patient-reported outcomes after surgical treatment or casting in patients age 60 years of age or older with unstable distal radius fractures (DRF's). The Wrist and Radius Injury Surgical Trial (WRIST), is the largest randomized, multicenter trial in Hand Surgery, which enrolled 304 adults with isolated, unstable DRF's at 24 institutions. WRIST participants were followed for 24 months- longest follow-up among prospective studies comparing four treatment methods. Patients who agreed to surgical treatment (n=187) were randomized to internal fixation with volar plate (VLPS), external fixation, or
The Gartland extension-type supracondylar humerus fracture is the most common elbow fracture in the paediatric population. Depending on fracture classification, treatment options range from nonoperative treatment such as taping, splinting or casting to operative treatments such as closed reduction and
Displaced proximal humerus fractures remain a difficult clinical problem, and techniques as diverse as
A reverse shoulder arthroplasty has become increasingly common for the treatment of proximal humerus fractures. A reverse shoulder arthroplasty is indicated especially in older and osteopenic individuals in whom the osteopenia, fracture type or comminution precludes fixation. However, there are many other ways to treat proximal humerus fractures and many of these are appropriate for different indications.
Introduction. Computer-assisted navigation is an established tool in hip and knee arthroplasty. This technology was introduced with the goals of greater precision in bone preparation and implant placement, potentially leading to improved clinical outcomes. Various navigation protocols exist, many of which require placement of temporary
The controversy of the management of this common fracture still remains and even the recent literature is not conclusive. Controversy is mainly because the need for either conservative or operative and what type of internal fixation mainly depends on many factors like age and patient factors, the type and convection of fracture and the bone quality. In the wake of the problem, the present study was undertaken mainly focusing on the importance of newer locking plates compared to
Closed reduction and
A group of UK paediatric surgeons (the UK SCFE Study Group) convened to design pertinent trials in slipped capital femoral epiphysis (SCFE), twelve centres across the UK reviewed the demographics and management of children with SCFE. At all contributing centres with digital PACS records, a search for terms relating to SCFE were performed. From the results, radiographs and electronically stored clinic letters were assessed to confirm the diagnosis and ascertain age at presentation, incidence of bilaterality, chronicity, stability, management and complications. A total of 601 SCFEs presented between 2007 and 2012 to the twelve units. The mean age at presentation was 12.5 years. The left hip was nearly twice as commonly involved compared to the right (R: L = 3.3: 5.1), with bilateral presentation in 22% of patients. The most common mode of presentation was acute-on-chronic. Stable slips were over twice as common as unstable. The most common intervention was
We report our early experience with distracting external fixation used to offload the hip after avascular necrosis (AVN) of the femoral head secondary to severe slipped upper femoral epiphysis (SUFE). A case series of five patients treated in a tertiary centre is reported. Electronic case records and radiographs were reviewed. Data recorded included demographics, initial presentation, timing of head collapse, timing and duration of distraction and outcome including referral to adult arthoplasty services. Mean age at presentation was 12 years (range 12–15). 4 were females. Initial treatment in 4 cases was a delayed cuneiform osteotomy and pinning, one patient underwent serendipitous reduction and
Aims. Comparison of the outcome between the supine or prone positioned child with a supracondylar humerus fracture by measuring anaesthetic and operating time, functional outcomes and complications. Methods. All children with isolated Gartland 2 and 3 supracondylar humerus fractures were who were admitted to our institute, were asked to participate in the the study. For surgery, the participating children were either operated on in a ‘supine’ or ‘prone’ position. The children were randomly allocated to either the ‘supine’ or ‘prone’ position. The fractures were preferably treated by closed reduction and
Introduction. The classical Colles fracture (extraarticular, dorsally angulated distal radius fracture) in patients with osteoporotic bone is becoming increasingly more frequent. There still appears to be no clear consensus on the most appropriate surgical management of these injuries. The purpose of this study is to appraise the use of
The aim of this study is to determine the effects of the UK lockdown during the COVID-19 pandemic on the orthopaedic admissions, operations, training opportunities, and theatre efficiency in a large district general hospital. The number of patients referred to the orthopaedic team between 1 April 2020 and 30 April 2020 were collected. Other data collected included patient demographics, number of admissions, number and type of operations performed, and seniority of primary surgeon. Theatre time was collected consisting of anaesthetic time, surgical time, time to leave theatre, and turnaround time. Data were compared to the same period in 2019.Aims
Methods
Primary internal fixation of uncomplicated scaphoid fractures is growing in popularity due to its advantages over conventional cast fixation. Performing the procedure percutaneously reduces the risk of infection and soft tissue damage, but can be tricky because of the small size and complex three-dimensional (3D) shape of this bone. Computer-assisted navigation has been an invaluable tool in other pin insertion procedures. This in-vitro study aimed to evaluate two different rendering techniques for our navigation interface: (i) 3D volume rendering of the CBCT image to show digitally-reconstructed radiographs of the anatomy, and (ii) volume-slicing, analogous to CT-images. As the shape of the scaphoid is highly variable, a plastic model of the wrist was constructed in order to provide consistency that would not be possible in a cadaver-based study. The plastic model featured a removable scaphoid such that a new one was replaced between trials. Three surgeons each performed eight trials using each of the two navigated techniques (yielding a total of 48 trials for analysis). Central placement of scaphoid fixation has been linked with mechanical stability and improved clinical outcomes, thus the surgical goal was to place a K-wire to maximise both depth from the surface and length of the drill path. The wire was drilled through the scaphoid, from distal to proximal, allowing for post-trial analysis of the drill path. A ceiling-mounted OptoTrak Certus camera (Northern Digital Inc., Canada) and a floor-mounted isocentric 3D CBCT C-arm (Innova 4100, GE Healthcare, France) permitted a registration transformation between the tracking and imaging systems to be computed preoperatively, before each trial, using a custom calibration device. Optical local coordinate reference bodies were attached to the wrist model and a custom drill guide for tracking with the Certus camera. During each trial, a 3D spin image of the wrist model was acquired, and rendered according to the technique under study. For 3D volume rendering, the spin image was rendered as a digitally-reconstructed radiograph (DRR) that could be rotated in three dimensions. In the planning phase, the surgeon positioned a desired drill path on the images. Anterior-posterior and lateral views of the 3D volume rendering were used for navigation during the drilling phase. The real-time orientation of the drill guide was shown relative to these images and the plan on an overhead. For volume-sliced (VS) navigation, the spin image was volume-rendered and sliced along the principal planes (axial, coronal, sagittal) for planning. A slider interface allowed the surgeon to scroll through the slices in each of the planes, as if they were looking at individual CT slices. Once the desired drill path was positioned, the volume-sliced views were reconfigured to show slices along the oblique planes of the planned path for navigation. Following all trials, model scaphoids with wire intact were imaged using CT with a slice thickness of 0.625 mm. The CT series were segmented and used to construct 3D digital models of the wire and drilled scaphoid. Algorithms were developed to determine the minimum distance from the centerline of the wire and the scaphoid surface, and to compute the length of the drill path. Screw breach should be avoided as it disrupts the articular surface and may lead to a sequela of cartilage deterioration and osteoarthritic changes. The shortest distance measure was extrapolated to assess whether a standard fixation screw (Accutrak Mini, 1.78 mm radius) would have breached the scaphoid surface. There were three screw breaches noted in the 3D DRR trials, while only one occurred using volume-slicing. The minimum distance from the centerline of the wire to the scaphoid surface can also be thought of as a “safe zone” for screw breach. Although no difference in the mean distance (μ) was noted between groups (μ. DRR. = 2.3 mm, μ. VS. = 2.2 mm), the standard deviation (σ) was significantly higher for the DRR trials (σ. DRR. = 0.50 mm, σ. VS. = 0.37 mm, p < 0.1), suggesting a higher reliability of central placement using VS for navigation. In contrast, the length of the drill paths were significantly longer for the DRR trials (μ = 28.7 mm, σ = 0.66 mm) than for VS-navigation (μ = 28.3 mm, σ = 0.62 mm) at p < 0.1. The surgical goal was to pick a path that maximised both the length of the path, as well as the minimum distance from the scaphoid surface. Algorithms were developed to find the paths that would maximise: (i) the length and (ii) the distance from the surface of the model scaphoid used in this study. The maximum possible length was 29.8mm (with a minimum distance of 2.2mm from the scaphoid surface), and the maximum distance was 3.3mm (with a length of 27.5mm). Therefore, the set of optimal drill paths had length > 27.5 mm, and distance > 2.8 mm. Of the DRR-navigated trials, 11 were below the minimum optimal depth, and only one trial was below the optimal length; 13 of the 24 trials (54%) were of both optimal length and depth. Of the VS-navigated trials, nine were below the minimal optimal distance, and four were below the minimum optimal length; 11 out of 24 trials (46%) were within both the optimal length and depth. From this comparative study, we conclude that VS-navigation was superior in locating a central location for the fixation wire, while DRRs were superior in maximising the depth of the drill path. Thus, we propose a hybrid interface, incorporating both volume-slicing and DRRs, in order to maximise the effectiveness of navigation for
External fixation is widely used in orthopaedic
and trauma surgery. Infections around pin or wire sites, which are usually
localised, non-invasive, and are easily managed, are common. Occasionally,
more serious invasive complications such as necrotising fasciitis
(NF) and toxic shock syndrome (TSS) may occur. We retrospectively reviewed all patients who underwent external
fixation between 1997 and 2012 in our limb lengthening and reconstruction
programme. A total of eight patients (seven female and one male)
with a mean age of 20 years (5 to 45) in which pin/wire track infections
became limb- or life-threatening were identified. Of these, four
were due to TSS and four to NF. Their management is described. A
satisfactory outcome was obtained with early diagnosis and aggressive
medical and surgical treatment. Clinicians caring for patients who have external fixation and
in whom infection has developed should be aware of the possibility
of these more serious complications. Early diagnosis and aggressive
treatment are required in order to obtain a satisfactory outcome. Cite this article: