We analysed the serum C-reactive protein level, synovial fluid obtained by joint aspiration and five synovial biopsies from 145 knee replacements prior to revision to assess the value of these parameters in diagnosing late
Background. Revision total knee arthroplasty (rTKA) is a complex procedure with increased risk of blood loss and transfusions. The Musculoskeletal Infection Society has included D-dimer as a serology marker for
Introduction.
The rate of
This review summarises the opinions and conclusions
reached from a symposium on infected total knee replacement (TKR)
held at the British Association of Surgery of the Knee (BASK) annual
meeting in 2011. The National Joint Registry for England and Wales
reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused
by infection. The diagnosis of infection beyond the acute post-operative
stage relies on the identification of the causative organism by
aspiration and analysis of material obtained at arthroscopy. Ideal
treatment then involves a two-stage surgical procedure with extensive
debridement and washout, followed by antibiotics. An articulating
or non-articulating drug-eluting cement spacer is used prior to
implantation of the revision prosthesis, guided by the serum level
of inflammatory markers. The use of a single-stage revision is gaining popularity
and we would advocate its use in certain patients where the causative
organism is known, no sinuses are present, the patient is not immunocompromised,
and there is no radiological evidence of component loosening or
osteitis. It is our opinion that single-stage revision produces high-quality
reproducible results and will soon achieve the same widespread acceptance
as it does in infected hip arthroplasty.
In this paper, we will consider the current role
of simultaneous-bilateral TKA. Based on available evidence, it is
our opinion that bilateral one stage TKR is a safe and efficacious treatment
for patients with severe bilateral arthritic knee disease but should
be reserved for selected patients without significant medical comorbidities.
We report the results of revision total knee
replacement (TKR) in 26 patients with major metaphyseal osteolytic defects
using 29 trabecular metal cones in conjunction with a rotating hinged
total knee prosthesis. The osteolytic defects were types II and
III (A or B) according to the Anderson Orthopaedic Research Institute
(AORI) classification. The mean age of the patients was 72 years
(62 to 84) and there were 15 men and 11 women. In this series patients had
undergone a mean of 2.34 previous total knee arthroplasties. The
main objective was to restore anatomy along with stability and function
of the knee joint to allow immediate full weight-bearing and active
knee movement. Outcomes were measured using Knee Society scores,
Oxford knee scores, range of movement of the knee and serial radiographs.
Patients were followed for a mean of 36 months (24 to 49). The mean
Oxford knee clinical scores improved from 12.83 (10 to 15) to 35.20
(32 to 38) (p <
0.001) and mean American Knee Society scores
improved from 33.24 (13 to 36) to 81.12 (78 to 86) (p <
0.001).
No radiolucent lines suggestive of loosening were seen around the trabecular
metal cones, and by one year all the radiographs showed good osteo-integration.
There was no evidence of any collapse or implant migration. Our
early results confirm the findings of others that trabecular metal
cones offer a useful way of managing severe bone loss in revision
TKR. Cite this article:
We retrospectively reviewed 30 two-stage revision
procedures in 28 patients performed for fungal peri-prosthetic joint
infection (PJI) after a primary total knee replacement. Patients were
followed for at least two years or until the infection recurred.
The mean follow-up for patients who remained free of infection was
4.3 years (2.3 to 6.1). Overall, 17 patients were assessed as American
Society of Anesthesiologists grade 3 or 4. The surgical protocol included
removal of the infected implant, vigorous debridement and insertion
of an articulating cement spacer. This was followed by at least
six weeks of antimicrobial treatment and delayed reimplantation
in all patients. The mean interval between removal of the prosthesis
and reimplantation was 9.5 weeks (6 to 24). After reimplantation,
patients took antifungal agents orally for a maximum of six months. Fungal PJIs can be treated successfully by removal of all infected
material, appropriate antimicrobial treatment and delayed reimplantation.
This study aimed to determine the correlation between the amount of maximum flexion and the clinical outcome in 207 Koreans (333 knees) undergoing total knee replacement. The association of maximum flexion with clinical outcome was evaluated one year postoperatively using three scoring systems; the American Knee Society score, Western Ontario McMaster Universities Osteoarthritis index and the Short Form-36. The mean maximum flexion decreased post-operatively at 12 months from 140.1° (60° to 160°) to 133.0° (105° to 150°). Only the social function score of the Short Form-36 correlated significantly with maximum flexion (correlation coefficient = 0.180, p = 0.039). In comparative analyses of subgroups divided by a maximum flexion of 120°, we found no significant differences in any parameters except the social function score of the Short Form-36 (41.9