Advertisement for orthosearch.org.uk
Results 1 - 20 of 222
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 47 - 50
1 Jan 2010
Konan S Rayan F Haddad FS

The radiological evaluation of the anterolateral femoral head is an essential tool for the assessment of the cam type of femoroacetabular impingement. CT, MRI and frog lateral plain radiographs have all been suggested as imaging options for this type of lesion. The alpha angle is accepted as a reliable indicator of the cam type of impingement and may also be used as an assessment for the successful operative correction of the cam lesion. We studied the alpha angles of 32 consecutive patients with femoroacetabular impingement. The angle measured on frog lateral radiographs using templating tools was compared with that measured on CT scans in order to assess the reliability of the frog lateral view in analysing the alpha angle in cam impingement. A high interobserver reliability was noted for the assessment of the alpha angle on the frog lateral view with an intraclass correlation coefficient of 0.83. The mean alpha angle measured on the frog lateral view was 58.71° (32° to 83.3°) and that by CT was 65.11° (30° to 102°). A poor intraclass correlation coefficient (0.08) was noted between the measurements using the two systems. The frog lateral plain radiograph is not reliable for measuring the alpha angle. Various factors may be responsible for this such as the projection of the radiograph, the positioning of the patient and the quality of the image. CT may be necessary for accurate measurement of the alpha angle


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 597 - 603
1 May 2014
Nomura T Naito M Nakamura Y Ida T Kuroda D Kobayashi T Sakamoto T Seo H

Several radiological methods of measuring anteversion of the acetabular component after total hip replacement (THR) have been described. These studies used different definitions and reference planes to compare methods, allowing for misinterpretation of the results. We compared the reliability and accuracy of five current methods using plain radiographs (those of Lewinnek, Widmer, Liaw, Pradhan, and Woo and Morrey) with CT measurements, using the same definition and reference plane. We retrospectively studied the plain radiographs and CT scans in 84 hips of 84 patients who underwent primary THR. Intra- and inter-observer reliability were high for the measurement of inclination and anteversion with all methods on plain radiographs and CT scans. The measurements of inclination on plain radiographs were similar to the measurements using CT (p = 0.043). The mean difference between CT measurements was 0.6° (-5.9° to 6.8°). Measurements using Widmer’s method were the most similar to those using CT (p = 0.088), with a mean difference between CT measurements of -0.9° (-10.4° to 9.1°), whereas the other four methods differed significantly from those using CT (p < 0.001). This study has shown that Widmer’s method is the best for evaluating the anteversion of the acetabular component on plain radiographs. Cite this article: Bone Joint J 2014; 96-B:597–603


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1501 - 1508
1 Nov 2010
Donell ST Darrah C Nolan JF Wimhurst J Toms A Barker THW Case CP Tucker JK

Metal-on-metal total hip replacement has been targeted at younger patients with anticipated long-term survival, but the effect of the production of metal ions is a concern because of their possible toxicity to cells. We have reviewed the results of the use of the Ultima hybrid metal-on-metal total hip replacement, with a cemented polished tapered femoral component with a 28 mm diameter and a cobalt-chrome (CoCr) modular head, articulating with a 28 mm CoCr acetabular bearing surface secured in a titanium alloy uncemented shell. Between 1997 and 2004, 545 patients with 652 affected hips underwent replacement using this system. Up to 31 January 2008, 90 (13.8%) hips in 82 patients had been revised. Pain was the sole reason for revision in 44 hips (48.9%) of which 35 had normal plain radiographs. Peri-prosthetic fractures occurred in 17 hips (18.9%) with early dislocation in three (3.3%) and late dislocation in 16 (17.8%). Infection was found in nine hips (10.0%). At operation, a range of changes was noted including cavities containing cloudy fluid under pressure, necrotic soft tissues with avulsed tendons and denuded osteonecrotic upper femora. Corrosion was frequently observed on the retrieved cemented part of the femoral component. Typically, the peri-operative findings confirmed those found on pre-operative metal artefact reduction sequence MRI and histological examination showed severe necrosis. Metal artefact reduction sequence MRI proved to be useful when investigating these patients with pain in the absence of adverse plain radiological features


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 3 | Pages 431 - 435
1 May 1999
Pradhan R

In total hip replacement, orientation of the cup is critical to the stability of the prosthesis. A new method to determine the angle of planar anteversion is described. A simple mathematical formula uses the measurements taken from anteroposterior radiographs to calculate the planar anteversion without reference to tables or charts.

An experimental study in vitro has shown the efficacy of the formula in giving results which are within a clinically acceptable range.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans. Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively. Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT. The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 2 - 2
7 Jun 2023
Sharrock M Board T
Full Access

It is unclear whether patients with early radiographic osteoarthritis (OA) but severe hip symptoms benefit from total hip replacement (THR). We aimed to assess which factors were associated with successful THR in this patient group. From a consecutive series of 1,935 patients undergoing THR we identified 70 (3.6%) patients with early OA (Kellgren and Lawrence (KL) grades 0-2). These were compared with 200 patients with advanced OA (KL grades 3–4). Outcomes were Oxford Hip Scores (OHS), EQ5D and EQ-VAS scores; compared pre-operatively with one year post-operatively. We investigated which clinical and radiographic (plain x-ray, CT, MRI) features predicted successful THR in the early OA group. Success was defined as reaching a postoperative OHS≥42. The early OA group were significantly younger (61 vs 66 years; P=0.0035). There were no significant differences in body mass index, ASA grade or gender. After adjusting for confounders, the advanced OA group had a significantly greater percentage of possible change (PoPC) in OHS (75.8% versus 50.4%; P<0.0001) and improvement in EQ5D (0.151 versus 0.002; P<0.0001). There were no significant differences in complication, revision or readmission rates. In the early OA group, we identified 16/70 (22.9%) patients who had a ‘successful’ THR. Of those with early OA, 38 patients had pre-operative CT or MRI scans. Patients who had a ‘successful’ THR were significantly more likely to have subchondral cysts on CT/MRI (91.7% versus 57.7%; P=0.0362). The presence of cysts on CT/MRI was associated with a significantly greater PoPC in OHS (61.6% versus 38.2%; P=0.0353). The combination of cysts and joint space width (JSW) <1mm was associated with a PoPC of 68%. Plain radiographs were found to significantly underestimate the narrowest JSW compared to CT/MRI (2.4mm versus 1.0mm; P<0.0001). We advise caution in performing THRs in patients with early OA (KL grades 0-2) on plain radiographs. We advocate pre-operative cross-sectional imaging (CT or MRI) in these patients. In the absence of cysts on cross-sectional imaging, a THR seems unlikely to provide a satisfactory outcome


The Bone & Joint Journal
Vol. 101-B, Issue 12 | Pages 1578 - 1584
1 Dec 2019
Batailler C Weidner J Wyatt M Pfluger D Beck M

Aims. A borderline dysplastic hip can behave as either stable or unstable and this makes surgical decision making challenging. While an unstable hip may be best treated by acetabular reorientation, stable hips can be treated arthroscopically. Several imaging parameters can help to identify the appropriate treatment, including the Femoro-Epiphyseal Acetabular Roof (FEAR) index, measured on plain radiographs. The aim of this study was to assess the reliability and the sensitivity of FEAR index on MRI compared with its radiological measurement. Patients and Methods. The technique of measuring the FEAR index on MRI was defined and its reliability validated. A retrospective study assessed three groups of 20 patients: an unstable group of ‘borderline dysplastic hips’ with lateral centre edge angle (LCEA) less than 25° treated successfully by periacetabular osteotomy; a stable group of ‘borderline dysplastic hips’ with LCEA less than 25° treated successfully by impingement surgery; and an asymptomatic control group with LCEA between 25° and 35°. The following measurements were performed on both standardized radiographs and on MRI: LCEA, acetabular index, femoral anteversion, and FEAR index. Results. The FEAR index showed excellent intraobserver and interobserver reliability on both MRI and radiographs. The FEAR index was more reliable on radiographs than on MRI. The FEAR index on MRI was lower in the stable borderline group (mean -4.2° (. sd. 9.1°)) compared with the unstable borderline group (mean 7.9° (. sd. 6.8°)). With a FEAR index cut-off value of 2°, 90% of patients were correctly identified as stable or unstable using the radiological FEAR index, compared with 82.5% using the FEAR index on MRI. The FEAR index was a better predictor of instability on plain radiographs than on MRI. Conclusion. The FEAR index measured on MRI is less reliable and less sensitive than the FEAR index measured on radiographs. The cut-off value of 2° for radiological FEAR index predicted hip stability with 90% probability. Cite this article: Bone Joint J 2019;101-B:1578–1584


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims. Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods. We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results. The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion. The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material. Cite this article: Bone Jt Open 2023;4(11):839–845


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 496 - 503
1 May 2023
Mills ES Talehakimi A Urness M Wang JC Piple AS Chung BC Tezuka T Heckmann ND

Aims. It has been well documented in the arthroplasty literature that lumbar degenerative disc disease (DDD) contributes to abnormal spinopelvic motion. However, the relationship between the severity or pattern of hip osteoarthritis (OA) as measured on an anteroposterior (AP) pelvic view and spinopelvic biomechanics has not been well investigated. Therefore, the aim of the study is to examine the association between the severity and pattern of hip OA and spinopelvic motion. Methods. A retrospective chart review was conducted to identify patients undergoing primary total hip arthroplasty (THA). Plain AP pelvic radiographs were reviewed to document the morphological characteristic of osteoarthritic hips. Lateral spine-pelvis-hip sitting and standing plain radiographs were used to measure sacral slope (SS) and pelvic femoral angle (PFA) in each position. Lumbar disc spaces were measured to determine the presence of DDD. The difference between sitting and standing SS and PFA were calculated to quantify spinopelvic motion (ΔSS) and hip motion (ΔPFA), respectively. Univariate analysis and Pearson correlation were used to identify morphological hip characteristics associated with changes in spinopelvic motion. Results. In total, 139 patients were included. Increased spinopelvic motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.05). Loss of hip motion was observed in patients with loss of femoral head contour, cam deformity, and acetabular bone loss (all p < 0.001). A decreased joint space was associated with a decreased ΔPFA (p = 0.040). The presence of disc space narrowing, disc space narrowing > two levels, and disc narrowing involving the L5–S1 segment were associated with decreased spinopelvic motion (all p < 0.05). Conclusion. Preoperative hip OA as assessed on an AP pelvic radiograph predicts spinopelvic motion. These data suggest that specific hip osteoarthritic morphological characteristics listed above alter spinopelvic motion to a greater extent than others. Cite this article: Bone Joint J 2023;105-B(5):496–503


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 1 - 1
2 May 2024
Mayne A Saad A Botchu R Politis A Wall P McBryde C
Full Access

Radiological investigations are essential in the work-up of patients presenting with non-arthritic hip pain, to allow close review of the complex anatomy around the hip and proximal femur. The aim of this study is to quantify the radiation exposure associated with common radiological investigations performed in assessing young adult patients presenting with non-arthritic hip pain. A retrospective review of our UK tertiary hip preservation centre institutional imaging database was performed. Data was obtained for antero-posterior, cross-table lateral and frog-lateral radiographs, along with data for the low dose CT hip protocol and the Mako CT Hip protocol. The radiation dose of each imaging technique was measured in terms of dose-area product (DAP) with units of mGycm2, and the effective doses (ED, mSv) calculated. The mean effective radiation dose for hip radiographs was in the range 0.03 to 0.83mSv (mean DLP 126.7–156.2 mGycm2). The mean effective dose associated with the low-dose CT hip protocol was 3.04mSv (416.8 mGycm2) and for the Stryker Mako CT Hip protocol was 8.4mSv (1061 mGycm2). The radiation dose associated with use of CT imaging was significantly greater than plain radiographs (p<0.005). Investigation of non-arthritic hip pain can lead to significant ionising radiation exposure for patients. In our institution, the routine protocol is to obtain an anteroposterior radiograph and then a specific hip sequence 3 Tesla MRI including anteversion views. This provides the necessary information in the majority of cases, with CT scanning reserved for more complex cases where we feel there is a specific indication. We would encourage the hip preservation community to carefully consider and review the use of ionising radiation investigations


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 87 - 87
19 Aug 2024
Logishetty K Verhaegen J Hutt J Witt J
Full Access

There is some evidence to suggest that outcomes of THA in patients with minimal radiographic osteoarthritis may not be associated with predictable outcomes. The aim of this study was to:. Assess the outcome of patients with hip pain who underwent THA with no or minimal radiographic signs of osteoarthritis,. Identify patient comorbidities and multiplanar imaging findings which are predictive of outcome,. Compare the outcome in these patients to the expected outcome of THA in hip OA. A retrospective review of 107 hips (102 patients, 90F:12M, median age 40.6, IQR 35.1–45.8 years, range 18–73) were included for analysis. Plain radiographs were evaluated using the Tonnis grading scale of hip OA. Outcome measures were all-cause revision; iHOT12; EQ-5D; Oxford Hip Score; UCLA Activity Scale; and whether THA had resulted in the patient's hip pain and function being Better/Same/Worse. The median Oxford Hip Score was 33.3 (IQR 13.9, range 13–48), and 36/107 (33.6%) hips achieved an OHS≥42. There was no association between primary hip diagnosis and post-operative PROMs. A total of 91 of the 102 patients (89.2%, 93 hips) reported that their hip pain and function was Better than prior to THA and would have the surgery again, 7 patients (6.8%, 10 hips) felt the Same, and 4 patients (3.9%, 4 hips) felt Worse and would not have the surgery again. Younger patients undergoing total hip arthroplasty with no or minimal radiographic osteoarthritis had lower postoperative Oxford Hip Scores than the general population; though most felt symptomatically better and knowing what they know now, would have surgery again. Those with chronic pain syndrome or hypermobility were likely to benefit less. Those with subchondral cysts or joint space narrowing on CT imaging were more likely to achieve higher functional scores and satisfaction


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 500 - 506
1 Mar 2021
Leonard HJ Ohly NE

Aims. The purpose of this study was to compare the clinical, radiological, and patient-reported outcome measures (PROMs) in the first 100 consecutive patients undergoing total hip arthroplasty (THA) via a direct superior approach (DSA) with a matched group of patients undergoing THA by the same surgeon, using a posterolateral approach (PLA). Methods. This was a retrospective single surgeon study comparing the first 100 consecutive DSA THA patients with a matched group of patients using a standard PLA. Case notes were examined for patient demographics, length of hospital stay, operating time, intra- and postoperative complications, pain score, satisfaction score, and Oxford Hip Score (OHS). Leg length discrepancy and component positioning were measured from postoperative plain radiographs. Results. The DSA patients had a shorter length of hospital stay (mean 2.09 days (SD 1.20) DSA vs 2.74 days (SD 1.17) PLA; p < 0.001) and shorter time to discharge from the inpatient physiotherapy teams (mean 1.44 days (SD 1.17) DSA vs 1.93 days (SD 0.96) PLA; p < 0.001). There were no differences in operating time (p = 0.505), pain levels up to postoperative day 1 (p = 0.106 to p =0.242), OHS (p = 0.594 to p = 0.815), satisfaction levels (p = 0.066 to p = 0.299), stem alignment (p = 0.240), acetabular component inclination (p < 0.001) and anteversion (p < 0.001), or leg length discrepancy (p = 0.134). Conclusion. While the DSA appears safe and was not associated with a significant difference in PROMs, radiological findings, or intraoperative or postoperative complications, a randomized controlled trial with functional outcomes in the postoperative phase is needed to evaluate this surgical approach formally. Cite this article: Bone Joint J 2021;103-B(3):500–506


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 41 - 41
1 Oct 2019
Braly HL Rodriguez D Schroder S Thomas J Delgadillo LE Noble PC
Full Access

Introduction. The Vancouver Classification System presents a systematic approach to classification of periprosthetic fractures of the proximal femur (PFPFs) that has been validated in previous studies. However, with the introduction of tapered fluted stems and cable plates since the introduction of the Vancouver System, the connection between fracture class and the preferred method of treatment is often unclear. The present study was undertaken to identify fracture patterns surrounding contemporary femoral stems and the relationship between the current method of treatment and the Vancouver Class of the periprosthetic fracture. Methods. Three experienced joint surgeons collected plain radiographs (AP and lateral) and CT/MR scans (n=40) from 72 cases of Vancouver A or B periprosthetic fractures performed over the period 2016–2018. We identified the mode of primary stem fixation and the Vancouver grade of the fracture (A, B1, B2 or B3). Two independent investigators examined all imaging studies and the intraoperative records and recorded: (i) and the location and distribution of the fracture surfaces, and (ii) the presence of incomplete cortical fractures that had initiated within the femoral cortex without completing propagation and (iii) the method of operative treatment. These data were analyzed to examine the incidence of fractures within more than one femoral zone and differences in the fracture patterns corresponding to each Vancouver class. Results. One fifth (21%) of fractures were Type A with the remainder consisting predominantly of Type B2 (39%), with approximately equal proportions of Type B1 (22%) and B3 (18%) fractures. In almost half of Type B2 fractures (a loose femoral stem and a fracture adjacent to the prosthesis), fractures were also present within the metaphysis (ie. Type A+B). In the presence of a cementless femoral stem, fractures often occurred adjacent to the uncoated surface of the stem distal to the proximal ingrowth surface. Type B2 and B3 femurs had similar fracture patterns and degrees of comminution, though their method of treatment differed significantly. Incomplete fractures were identified in every Vancouver class (entire sample: 22%), especially in association with loose stems in poor quality bone (Type B3; 38% of cases). Conclusions. Approximately two-thirds of periprosthetic femoral fractures involve a loose femoral component (ie Types B2 and B3), though bone quality impacts operative treatment. In cementless stems, Vancouver Type B fractures often occur in the unbonded diaphysis between the distal edge of the ingrowth surface and immediately below the stem tip. Incomplete fractures are present in a surprising proportion of cases, suggesting that careful examination of imaging studies is needed to prevent fracture propagation due to inadequate fixation. CT scans are a useful adjunct to supplement plain radiographs. For any tables or figures, please contact the authors directly


Bone & Joint Open
Vol. 1, Issue 10 | Pages 653 - 662
20 Oct 2020
Rahman L Ibrahim MS Somerville L Teeter MG Naudie DD McCalden RW

Aims. To compare the in vivo long-term fixation achieved by two acetabular components with different porous ingrowth surfaces using radiostereometric analysis (RSA). Methods. This was a minimum ten-year follow-up of a prospective randomized trial of 62 hips with two different porous ingrowth acetabular components. RSA exams had previously been acquired through two years of follow-up. Patients returned for RSA examination at a minimum of ten years. In addition, radiological appearance of these acetabular components was analyzed, and patient-reported outcome measures (PROMs) obtained. Results. In all, 15 hips were available at ten years. There was no statistically significant difference in PROMS between the two groups; PROMs were improved at ten years compared to preoperative scores. Conventional radiological assessment revealed well-fixed components. There was minimal movement for both porous surfaces in translation (X, Y, Z, 3D translation in mm (median and interquartile range (IQR)), StikTite (Smith and Nephew, Memphis, Tennessee, USA): 0.03 (1.08), 0.12 (0.7), 0.003 (2.3), 0.37 (0.30), and Roughcoat (Smith and Nephew): -0.6 (0.59),–0.1 (0.49), 0.1 (1.12), 0.48 (0.38)), and rotation (X, Y, Z rotation in degrees (median and IQR), (Stiktite: -0.4 (3), 0.28 (2), -0.2 (1), and Roughcoat: - 0.4 (1),–0.1 (1), 0.2 (2)). There was no statistically significant difference between the two cohorts (p-value for X, Y, Z, 3D translation - 0.54, 0.46, 0.87, 0.55 and for X, Y, Z rotation - 0.41, 0.23, 0.23 respectively) at ten years. There was significant correlation between two years and ten years 3D translation for all components (r = 0.81(p =< 0.001)). Conclusion. Both porous ingrowth surfaces demonstrated excellent fixation on plain radiographs and with RSA at ten years. Short-term RSA data are good predictors for long-term migration data


The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1042 - 1049
1 Sep 2019
Murphy MP Killen CJ Ralles SJ Brown NM Hopkinson WJ Wu K

Aims. Several radiological methods of measuring anteversion of the acetabular component after total hip arthroplasty (THA) have been described. These are limited by low reproducibility, are less accurate than CT 3D reconstruction, and are cumbersome to use. These methods also partly rely on the identification of obscured radiological borders of the component. We propose two novel methods, the Area and Orthogonal methods, which have been designed to maximize use of readily identifiable points while maintaining the same trigonometric principles. Patients and Methods. A retrospective study of plain radiographs was conducted on 160 hips of 141 patients who had undergone primary THA. We compared the reliability and accuracy of the Area and Orthogonal methods with two of the current leading methods: those of Widmer and Lewinnek, respectively. Results. The 160 anteroposterior pelvis films revealed that the proposed Area method was statistically different from those described by Widmer and Lewinnek (p < 0.001 and p = 0.004, respectively). They gave the highest inter- and intraobserver reliability (0.992 and 0.998, respectively), and took less time (27.50 seconds (. sd. 3.19); p < 0.001) to complete. In addition, 21 available CT 3D reconstructions revealed the Area method achieved the highest Pearson’s correlation coefficient (r = 0.956; p < 0.001) and least statistical difference (p = 0.704) from CT with a mean within 1° of CT-3D reconstruction between ranges of 1° to 30° of measured radiological anteversion. Conclusion. Our results support the proposed Area method to be the most reliable, accurate, and speedy. They did not support any statistical superiority of the proposed Orthogonal method to that of the Widmer or Lewinnek method. Cite this article: Bone Joint J 2019;101-B:1042–1049


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 760 - 767
1 Jul 2019
Galea VP Rojanasopondist P Laursen M Muratoglu OK Malchau H Bragdon C

Aims. Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. Patients and Methods. A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up. Results. In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (. sd. 0.16) and 0.00 mm (. sd. 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (. sd. 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (. sd. 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening. Conclusion. This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760–767


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1275 - 1279
1 Oct 2018
Fader RR Tao MA Gaudiani MA Turk R Nwachukwu BU Esposito CI Ranawat AS

Aims. The purpose of this study was to evaluate spinopelvic mechanics from standing and sitting positions in subjects with and without femoroacetabular impingement (FAI). We hypothesize that FAI patients will experience less flexion at the lumbar spine and more flexion at the hip whilst changing from standing to sitting positions than subjects without FAI. This increase in hip flexion may contribute to symptomatology in FAI. Patients and Methods. Male subjects were prospectively enrolled to the study (n = 20). Mean age was 31 years old (22 to 41). All underwent clinical examination, plain radiographs, and dynamic imaging using EOS. Subjects were categorized into three groups: non-FAI (no radiographic or clinical FAI or pain), asymptomatic FAI (radiographic and clinical FAI but no pain), and symptomatic FAI (patients with both pain and radiographic FAI). FAI was defined as internal rotation less than 15° and alpha angle greater than 60°. Subjects underwent standing and sitting radiographs in order to measure spine and femoroacetabular flexion. Results. Compared with non-FAI controls, symptomatic patients with FAI had less flexion at the spine (mean 22°, . sd. 12°, vs mean 35°, . sd. 8°; p = 0.04) and more at the hip (mean 72°, . sd. 6°, vs mean 62°, . sd. 8°; p = 0.047). Subjects with asymptomatic FAI had more spine flexion and similar hip flexion when compared to symptomatic FAI patients. Both FAI groups also sat with more anterior pelvic tilt than control patients. There were no differences in standing alignment among groups. Conclusion. Symptomatic patients with FAI require more flexion at the hip to achieve sitting position due to their inability to compensate through the lumbar spine. With limited spine flexion, FAI patients sit with more anterior pelvic tilt, which may lead to impingement between the acetabulum and proximal femur. Differences in spinopelvic mechanics between FAI and non-FAI patients may contribute to the progression of FAI symptoms. Cite this article: Bone Joint J 2018;100-B:1275–9


The Bone & Joint Journal
Vol. 101-B, Issue 1_Supple_A | Pages 11 - 18
1 Jan 2019
Kayani B Konan S Thakrar RR Huq SS Haddad FS

Objectives. The primary objective of this study was to compare accuracy in restoring the native centre of hip rotation in patients undergoing conventional manual total hip arthroplasty (THA) versus robotic-arm assisted THA. Secondary objectives were to determine differences between these treatment techniques for THA in achieving the planned combined offset, component inclination, component version, and leg-length correction. Materials and Methods. This prospective cohort study included 50 patients undergoing conventional manual THA and 25 patients receiving robotic-arm assisted THA. Patients undergoing conventional manual THA and robotic-arm assisted THA were well matched for age (mean age, 69.4 years (. sd. 5.2) vs 67.5 years (. sd. 5.8) (p = 0.25); body mass index (27.4 kg/m. 2. (. sd. 2.1) vs 26.9 kg/m. 2. (. sd. 2.2); p = 0.39); and laterality of surgery (right = 28, left = 22 vs right = 12, left = 13; p = 0.78). All operative procedures were undertaken by a single surgeon using the posterior approach. Two independent blinded observers recorded all radiological outcomes of interest using plain radiographs. Results. The correlation coefficient was 0.92 (95% confidence interval (CI) 0.88 to 0.95) for intraobserver agreement and 0.88 (95% CI 0.82 to 0.94) for interobserver agreement in all study outcomes. Robotic THA was associated with improved accuracy in restoring the native horizontal (p < 0.001) and vertical (p < 0.001) centres of rotation, and improved preservation of the patient’s native combined offset (p < 0.001) compared with conventional THA. Robotic THA improved accuracy in positioning of the acetabular component within the combined safe zones of inclination and anteversion described by Lewinnek et al (p = 0.02) and Callanan et al (p = 0.01) compared with conventional THA. There was no difference between the two treatment groups in achieving the planned leg-length correction (p = 0.10). Conclusion. Robotic-arm assisted THA was associated with improved accuracy in restoring the native centre of rotation, better preservation of the combined offset, and more precise acetabular component positioning within the safe zones of inclination and anteversion compared with conventional manual THA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 4 - 4
1 Jul 2020
Salih S Grammatopoulos G Witt J
Full Access

Acetabular dysplasia (AD) can cause hip pain and early osteoarthritis. Lateral Centre Edge Angle (LCEA) and sourcil angle (AI) are plain radiographic measures of acetabular morphology, however there is little agreement as to what constitutes mild, moderate or severe dysplasia. This study aims to establish the correlation, if any, between two-dimensional (XR) and three-dimensional (CT) measurements of acetabular morphology and to establish the level of femoral head cover (CTFHC) for different levels of dysplasia. Methods. Governance board approved retrospective study. 353 PAOs performed by the senior author between January 2014 and December 2017 were included. Exclusion criteria were inadequate pre-operative CT imaging and/or plain radiographs, previous pelvic/hip surgery, acetabular retroversion, or femoral head asphericity. Of the remainder, 84 had 3D analysis by clinical graphics giving measurements for CTFHC, LCEA at 1100, 1200, 1300 and sourcil angle (AI). XRLCEA, AI, posterior wall index (PWI), and anterior wall index (AWI), were measured from supine AP pelvis radiographs. Pearson correlation coefficient, and mean CTFHC for stratified LCEAs were calculated. A linear regression model to predict CTFHC from XRLCEA was validated against these. Results. XRLCEA correlated very strongly with total femoral head coverage (Pearson=0.917, p<0.001). Mean CTFHC with XRLCEA between 15°-19.9° was 55% (range 51–59%). At 25° −29.9° mean CTFHC was 61%. There was a linear relation of CTFHC with XR LCEA such that CTFHC = 41.5 + 0.78(XRLCEA). This linear regression model predicted CTFHC 55% (95%CI 54–56%) for XRLCEA of 17.5°, and CTFHC 63% (95%CI 62–64%) for XRLCEA 27.5°. Conclusions. Currently an XRLCEA greater than 25° is considered normal. Previously reported normal values for CTFHC are 71–75%. This study demonstrates that those with acetabular parameters considered normal, may have low CTFHC and AD should be considered as a cause for their hip pain


The Bone & Joint Journal
Vol. 99-B, Issue 1 | Pages 44 - 50
1 Jan 2017
Salo PP Honkanen PB Ivanova I Reito A Pajamäki J Eskelinen A

Aims. We evaluated the short-term functional outcome and prevalence of bearing-specific generation of audible noise in 301 patients (336 hips) operated on with fourth generation (Delta) medium diameter head, ceramic-on-ceramic (CoC) total hip arthroplasties (THAs). Patients and Methods. There were 191 female (63%) and 110 male patients (37%) with a mean age of 61 years (29 to 78) and mean follow-up of 2.1 years (1.3 to 3.4). Patients completed three questionnaires: Oxford Hip Score (OHS), Research and Development 36-item health survey (RAND-36) and a noise-specific symptom questionnaire. Plain radiographs were also analysed. A total of three hips (0.9%) were revised. . Results. There were 52 patients (54 hips, 17%) who reported noise, and in 25 (48%) of them the noise was frequently heard. In the multiple regression analysis, the only independent risk factor for noise was a specific THA brand, with a threefold increased risk (95% confidence intervals 1.39 to 6.45, p = 0.005) of noise compared with the reference THA brand. Patients with noisy hips had lower median OHS (43 versus 46.5, p = 0.002) and their physical functioning (p = 0.021) subscale in RAND-36 was reduced. Conclusion. Noise was surprisingly common in this population. Cite this article: Bone Joint J 2017;99-B:44–50