Advertisement for orthosearch.org.uk
Results 1 - 20 of 517
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1230 - 1237
1 Oct 2019
Kayani B Konan S Horriat S Ibrahim MS Haddad FS

Aims. The aim of this study was to assess the effect of posterior cruciate ligament (PCL) resection on flexion-extension gaps, mediolateral soft-tissue laxity, fixed flexion deformity (FFD), and limb alignment during posterior-stabilized (PS) total knee arthroplasty (TKA). Patients and Methods. This prospective study included 110 patients with symptomatic osteoarthritis of the knee undergoing primary robot-assisted PS TKA. All operations were performed by a single surgeon using a standard medial parapatellar approach. Optical motion capture technology with fixed femoral and tibial registration pins was used to assess gaps before and after PCL resection in extension and 90° knee flexion. Measurements were made after excision of the anterior cruciate ligament and prior to bone resection. There were 54 men (49.1%) and 56 women (50.9%) with a mean age of 68 years (. sd. 6.2) at the time of surgery. The mean preoperative hip-knee-ankle deformity was 4.1° varus (. sd. 3.4). Results. PCL resection increased the mean flexion gap significantly more than the extension gap in the medial (2.4 mm (. sd. 1.5) vs 1.3 mm (. sd. 1.0); p < 0.001) and lateral (3.3 mm (. sd. 1.6) vs 1.2 mm (. sd. 0.9); p < 0.01) compartments. The mean gap differences after PCL resection created significant mediolateral laxity in flexion (gap difference: 1.1 mm (. sd. 2.5); p < 0.001) but not in extension (gap difference: 0.1 mm (. sd. 2.1); p = 0.51). PCL resection significantly improved the mean FFD (6.3° (. sd. 4.4) preoperatively vs 3.1° (. sd. 1.5) postoperatively; p < 0.001). There was a strong positive correlation between the preoperative FFD and change in FFD following PCL resection (Pearson’s correlation coefficient = 0.81; p < 0.001). PCL resection did not significantly affect limb alignment (mean change in alignment: 0.2° valgus (. sd. 1.2); p = 0.60). Conclusion. PCL resection creates flexion-extension mismatch by increasing the flexion gap more than the extension gap. The increase in the lateral flexion gap is greater than the increase in the medial flexion gap, which creates mediolateral laxity in flexion. Improvements in FFD following PCL resection are dependent on the degree of deformity before PCL resection. Cite this article: Bone Joint J 2019;101-B:1230–1237


Bone & Joint Research
Vol. 3, Issue 4 | Pages 95 - 100
1 Apr 2014
Kaneyama R Otsuka M Shiratsuchi H Oinuma K Miura Y Tamaki T

Objectives. Because posterior cruciate ligament (PCL) resection makes flexion gaps wider in total knee replacement (TKR), preserving or sacrificing a PCL affects the gap equivalence; however, there are no criteria for the PCL resection that consider gap situations of each knee. This study aims to investigate gap characteristics of knees and to consider the criteria for PCL resection. Methods. The extension and flexion gaps were measured, first with the PCL preserved and subsequently with the PCL removed (in cases in which posterior substitute components were selected). The PCL preservation or sacrifice was solely determined by the gap measurement results, without considering other functions of the PCL such as ‘roll back.’. Results. Wide variations were observed in the extension and flexion gaps. The flexion gaps were significantly larger than the extension gaps. Cases with 18 mm or more flexion gap and with larger flexion than extension gap were implanted with cruciate retaining component. A posterior substitute component was implanted with the other cases. Conclusions. In order to make adequate gaps, it is important to decide whether to preserve the PCL based on the intra-operative gap measurements made with the PCL intact. Cite this article: Bone Joint Res 2014;3:95–100


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 250 - 250
1 May 2009
Chaudhary R Beaupre L Johnston B
Full Access

To compare posterior cruciate ligament substituting (PCS) total knee arthroplasty (TKA) and posterior cruciate ligament retaining (PCR) total knee arthroplasty (TKA) to determine if greater overall flexion is obtained with the PCS TKA versus the PCR TKA at two year postoperative follow up. Secondarily, to determine whether there is a difference in the recovery of range of motion over time between the two groups from initial presentation, to discharge, and to follow up visits at three months, one year, and two years. Prospective, randomised double-blind clinical trial consisting of one hundred male and female patients scheduled for primary TKA. Sample size allows detection of a difference of six degrees of knee range of motion using two-tailed tests, =0.05, and 0.20 (80% power). SCORPIO PCL substituting total knee system and the SCORPIO PCL retaining total knee system were implanted for evaluation in this study. Patients were assessed at initial presentation, at postoperative discharge from hospital, and at follow up visits at three months, one year and two years for flexion knee range of motion. Additional data were collected utilizing the WOMAC Osteoarthritis Index, the Knee Society Clinical Rating Scale, the SF-36, and the Knee Society Radiographic Evaluation as well as data on length of stay and surgical time. Subjects were similar in demographic characteristics and all measurements at the baseline initial assessment. No differences were seen in knee flexion at two year follow up as measured using an independent t-test (p> 0.05). Recovery of knee range of motion over time was not different as measured using a two way repeated measures ANOVA (p=0.88 for group effect). Postoperative flexion and recovery of kneww range of motion was not altered following TKA by using PCS or PCR prostheses


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 143 - 143
1 Apr 2005
Witvoet J Masse Y Nizard R Huten D Augereau B Aubriot J
Full Access

Purpose: At a time when total knee arthroplasty (TKA) with an ultra-congruent tibial plateau or a mobile plateau are advocated by many, the question is whether TKA with a fixed plateau preserving the posterior cruciate ligament (PCL) should be abandoned. We analysed the results of 500 Wallaby I TKA with preservation of the PCL and presenting asymmetrical and divergent femoral condyles with a fixed, also assymetrical tibial plateau, at mean follow-up of seven years (1–10). Material and methods: This prospective multicentric study was performed by junior and senior surgeons. Mean patient age was 70.11 years and 91.4% of the patients had primary or secondary degenerative disease. Prior surgery had been performed in 130 knees, mainly for osteotomy (n=40, mostly tibial) and revision of uni-compartmental or total prostheses (n=18). The mean preoperative IKS knee score was 26.11 points, the function score was 29.54. Preoperative alignment was correct for 11.26% of the knees, 27.16% presented > 4° valgus and 61.56% > 3° varus. Nearly all tibial and patellar pieces were cemented. 5.8% of the femoral pieces were not cemented. A prosthesis was implanted on the patella in all knees except four. There were two early infections, one popliteal sciatic paralysis and twelve wound healing problems. General mobilisation under general anaesthesia was performed in 53 knees (10.6%). Results: Twenty-two patients were not retained for analysis, fifteen lost to follow-up and seven deceased at one year. Among the 478 knees followed for one to ten years, there were six late infections (1.25%), one aseptic bipolar loosening (0.2%), 25 patellar fractures (5.23%) including three which required revision (two cerclage, one prosthesis removal), three periprosthetic femur fractures without effect on the clinical or radiographic outcome, one traumatic tear of the medial collateral ligament, and two secondary tears of the PCL without clinical consequences. There were no revisions for instability, generally considered the most frequent reason for TKA revision. The mean postoperative IKS score was 90.6 points and the function score was 59.7 points basically due to patient age and comorbidity. The eight-year survival (Kaplan-Meier method) was 98.2% (95%CI: 99.4–96.9) irrespective of the reason for revision and 99.2% (95%CI 100–98.4%) if the revision was performed for a mechanical problem. Radiographically, more than 70% of the knees were aligned (between 3° valgus and 2° varus) and more than 90% were between 5° valgus and 5° varus. Although it was difficult to measure radiographically polyethylene wear, there was only one case of > 2 mm wear with osteolysis found in 50 knees selected randomly among the knees with more than seven years follow-up. Conclusion: This study, like others reported by authors preserving the PCL, show that preservation of the PCL limits the risk of instability, allowing excellent clinical and radiographic outcome without important polyethylene wear, opening perspectives for good long-term results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 87 - 87
7 Nov 2023
Arakkal A Bonner B Scheepers W Van Bornmann R Held M De Villiers R
Full Access

Poor availability of allografts in South Africa has led to an increased use of synthetic augmentation to stabilize knee joints in the treatment of knee dislocations. This study aims to evaluate multiligament knee injuries treated with a posterior cruciate ligament internal brace. The study included patients with knee dislocations who were treated with a PCL internal brace. The internal brace involved the insertion of a synthetic suture tape, which was drilled into the femoral and tibial footprint. Chronic injuries were excluded. Patient-reported outcome scores (PROMs), range of motion, stress X-Rays, and MRI scans were reviewed to assess outcomes. Acceptable outcomes were defined as a Lysholm score of 84 or more, with grade II laxity in no more than one ligament and a range of motion from full extension to 90° or more. The study included eight patients, with a median age of 42, of which five were female. None of the patients had knee flexion less than 90° or an extension deficit of more than 20°. PROMs indicated acceptable outcomes (EQ5D, Tegner Lysholm). Stress radiographs showed less than 7mm (Grade I) of posterior translation laxity in all patients. Four patients underwent MRI scans 1–2 years after the initial surgery, which revealed healing of the PCL in all patients. However, increased signal in a continuous ligament suggested only partial healing in two patients. Tunnel widening of 200% and 250% was noted around the tibial and femoral PCL footprints, respectively. All patients demonstrated stable knees and acceptable PROMs. Tunnel widening was observed in all patients who had MRI scans. Factors such as suspensory fixation, anisometric tunnel position, and the absence of PCL tear repair may have contributed to the tunnel widening


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 8 | Pages 1046 - 1050
1 Aug 2007
Christen B Heesterbeek PV Wymenga A Wehrli U

We have examined the relationship between the size of the flexion gap and the anterior translation of the tibia in flexion during implantation of a posterior cruciate ligament (PCL)-retaining BalanSys total knee replacement (TKR). In 91 knees, the flexion gap and anterior tibial translation were measured intra-operatively using a custom-made, flexible tensor-spacer device. The results showed that for each increase of 1 mm in the flexion gap in the tensed knee a mean anterior tibial translation of 1.25 mm (SD 0.79, 95% confidence interval 1.13 to 1.37) was produced. When implanting a PCL-retaining TKR the surgeon should be aware that the tibiofemoral contact point is related to the choice of thickness of the polyethylene insert. An additional thickness of polyethylene insert of 2 mm results in an approximate increase in tibial anterior translation of 2.5 mm while the flexed knee is distracted with a force of between 100 N and 200 N


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 33 - 33
1 Dec 2014
van der Merwe W
Full Access

Background:. For the past four decades controversy surrounds the decision to retain or sacrifice the posterior cruciate ligament during a total knee arthroplasty. To our knowledge no study has been done to describe the effect of releasing the PCL on the range of motion of the knee. Study design:. Case series. Methods:. Computer navigation data (Brainlab) was obtained intra-operatively from thirty patients at total knee arthroplasty. Coronal alignment, maximal passive knee extension and maximal passive flexion was captured before and after release of the PCL. Results:. Releasing the posterior cruciate ligament led to an increase in maximal extension in all patients (av 3,6°) and a decrease in coronal deformity in 63%. The surprising finding was an increase in maximal knee flexion (av 5°, range 0 to 10°.) The increase in maximal flexion was statistically significant. Conclusion:. Sacrificing the posterior cruciate ligament alters the kinematics of the knee and the resultant increase in knee flexion might explain why cruciate sacrificing total knee arthroplasty has superior flexion compared to cruciate retaining designs


The Journal of Bone & Joint Surgery British Volume
Vol. 65-B, Issue 2 | Pages 204 - 209
1 Mar 1983
Pournaras J Symeonides P Karkavelas G

The significance of the posterior cruciate ligament in the stability of the knee was investigated in dogs and it was compared with that of the anterior cruciate ligament by studying the changes produced in the knee after transection of either ligament. Osteophyte formation and changes in articular cartilage were less prominent after division of the posterior cruciate ligament. A complete longitudinal tear of the medial meniscus was found in eight out of the 10 dogs who had undergone section of the anterior cruciate but in none of the 10 with section of the posterior cruciate. It appears that, in dogs at least, the posterior cruciate ligament is less important than the anterior in the stability of the knee


The Bone & Joint Journal
Vol. 106-B, Issue 8 | Pages 808 - 816
1 Aug 2024
Hall AJ Cullinan R Alozie G Chopra S Greig L Clarke J Riches PE Walmsley P Ohly NE Holloway N

Aims. Total knee arthroplasty (TKA) with a highly congruent condylar-stabilized (CS) articulation may be advantageous due to increased stability versus cruciate-retaining (CR) designs, while mitigating the limitations of a posterior-stabilized construct. The aim was to assess ten-year implant survival and functional outcomes of a cemented single-radius TKA with a CS insert, performed without posterior cruciate ligament sacrifice. Methods. This retrospective cohort study included consecutive patients undergoing TKA at a specialist centre in the UK between November 2010 and December 2012. Data were collected using a bespoke electronic database and cross-referenced with national arthroplasty audit data, with variables including: preoperative characteristics, intraoperative factors, complications, and mortality status. Patient-reported outcome measures (PROMs) were collected by a specialist research team at ten years post-surgery. There were 536 TKAs, of which 308/536 (57.5%) were in female patients. The mean age was 69.0 years (95% CI 45.0 to 88.0), the mean BMI was 32.2 kg/m. 2. (95% CI 18.9 to 50.2), and 387/536 (72.2%) survived to ten years. There were four revisions (0.7%): two deep infections (requiring debridement and implant retention), one aseptic loosening, and one haemosiderosis. Results. Kaplan-Meier analysis demonstrated no difference in implant survival according to sex, age, or obesity status. Ten-year PROMs were available for 196/387 (50.6%) surviving patients and were excellent: mean Oxford Knee Score 34.4 (95% CI 32.7 to 36.1); mean Forgotten Joint Score (FJS) 51.2 (95% CI 16.1 to 86.3); mean EuroQol five-dimension five-level questionnaire score 69.9 (95% CI 46.8 to 93.0); 141/196 (71.9%) achieved the 22-point FJS patient-acceptable symptom state (PASS); and 156/196 (79.6%) were “very satisfied or satisfied”. Conclusion. This is the only large study reporting ten-year implant survival and functional outcomes of TKA using a cemented single-radius design and with a CS tibial bearing construct. The findings of excellent implant survival, safety, and functional outcomes indicate that this combination is a safe and effective option in routine TKA. Further investigation of this single-radius design TKA with CS tibial bearings with well-matched patient study groups will allow further insight into the performance of these implants. Cite this article: Bone Joint J 2024;106-B(8):808–816


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1381 - 1384
1 Oct 2010
Jacobi M Reischl N Wahl P Gautier E Jakob RP

We investigated the role of a functional brace worn for four months in the treatment of patients with an acute isolated tear of the posterior cruciate ligament to determine whether reduction of the posterior tibial translation during the healing period would give an improved final position of the tibia. The initial and follow-up stability was tested by Rolimeter arthrometry and radiography. The clinical outcome was evaluated using the Lysholm score, the Tegner score and the International Knee Documentation Committee scoring system at follow-up at one and two years. In all, 21 patients were studied, 21 of whom had completed one-year and 17 a two-year follow-up. The initial mean posterior sag (Rolimeter measurement) of 7.1 mm (5 to 10) was significantly reduced after 12 months to a mean of 2.3 mm (0 to 6, p < 0.001) and to a mean of 3.2 mm (2 to 7, p = 0.001) after 24 months. Radiological measurement gave similar results. The mean pre-injury Lysholm score was normal at 98 (95 to 100). At follow-up, a slight decrease in the mean values was observed to 94.0 (79 to 100, p = 0.001) at one year and 94.0 (88 to 100, p = 0.027, at two years). We concluded that the posterior cruciate ligament has an intrinsic healing capacity and, if the posteriorly translated tibia is reduced to a physiological position, it can heal with less attentuation. The applied treatment produces a good to excellent functional result


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 5 | Pages 671 - 674
1 Jul 2003
Straw R Kulkarni S Attfield S Wilton TJ

We report the results of a prospective randomised trial which assessed the role of the posterior cruciate ligament (PCL) following total knee replacement (Genesis I; Smith and Nephew, Memphis, Tennessee). Over a four-year period, 211 patients underwent total knee replacement by the senior author (TJW). They were randomised at surgery to have the PCL either retained, excised or substituted with a posterior stabilised insert. If it was not possible to retain the ligament due to soft-tissue imbalance, it was released from its tibial insertion until suitable tension was obtained. This created a fourth group, those who were intended preoperatively to have the ligament retained, but in whom it was partially released as a result of findings at the time of surgery. All patients were evaluated using the Knee Society rating system (adapted from Insall). A total of 188 patients (212 knees) was available for follow-up at a mean of 3.5 years after surgery. Preoperatively, there was a varus deformity in 191 knees (90%) and a valgus deformity in 21 (10%). There were no statistical differences in the knee or function scores or the range of movement between the excised, retained and substituted groups. There were, however, significantly worse knee and function scores in the group in whom the PCL was released (p = 0.002)


The Journal of Bone & Joint Surgery British Volume
Vol. 50-B, Issue 2 | Pages 334 - 341
1 May 1968
Trickey EL

1. Seventeen cases of knee injury are described in which the predominant lesion was rupture of the posterior cruciate ligament. Seven were treated conservatively and ten by surgical repair. 2. Most cases occurred in motor cyclists. 3. The extent of the rupture should be determined by examination under anaesthesia. 4. Early surgical repair is indicated for complete rupture. 5. An effective method of repair is described


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 125 - 125
1 Jul 2002
Maruthainar N Graham D Surace F Bentley G
Full Access

The issue of preservation or sacrifice of the posterior cruciate ligament in total knee arthroplasty remains unresolved. We report the results of 200 consecutive total knee arthroplasties performed at our hospital under the direction of the senior author. Pre-operatively, patients were randomly chosen to receive either a Kinemax (posterior cruciate retaining) or a Press-Fit-Condylar (posterior cruciate sacrificing) prosthesis. We implanted 97 Kinemax and 103 Press-Fit-Condylar prostheses which were prospectively followed-up by clinical and radiographic assessment. Review at mean follow-up of 2.7 years showed a satisfactory clinical result in both groups [Surace, et al., 1994]. We present the results of our further review, with maximum follow-up of over nine years (mean: 5.9 years). Revision of the implant has been performed in five knees (three Kinemax and two Press-Fit-Condylar). The polythene spacer had to be replaced in one patient with a Press-Fit-Condylar implant. Patients were assessed with the Hospital for Special Surgery Knee Score and radiologically assessed with the Knee Society Roentgenographic Evaluation and Scoring System. Pre-operative demographics and disease states of the patients were similar, with an average Hospital for Special Surgery Knee Score of 63. At the latest assessment the average knee score was good (85). Remarkably, the mean knee score for the posterior cruciate sacrifice and the PCL groups remains similar (mean: 85). Radiographic evaluation demonstrated that the prosthetic components of both groups were in comparable alignment. The posterior cruciate ligament retained (Kinemax) patient group showed a mean 5.9 degrees of the valgus angle at the knee. The angle in the posterior cruciate ligament sacrifice (PFC implant) group was 6.2 degrees. Evaluation of the radiolucent depths below the femoral, tibial and any patella component showed a mean total depth of 1.5 mm (pcl retaining) and 1.7 mm (pcl sacrificing). Our study presents a quantitative perspective of the results of total knee replacement with proven implant systems and performed in a general orthopaedic unit by both consultants and surgeons in training. The Kinemax (Howmedica) and Press-Fit-Condylar (DePuy Johnson and Johnson) implant systems have both previously demonstrated good results and continue to be available with little subsequent modification. To our knowledge, there have been no other large prospectively randomised studies of posterior cruciate ligament preservation or sacrifice in total knee replacement


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 455 - 455
1 Nov 2011
Zelle J De Waal Malefijt M Verdonschot N
Full Access

High-flexion knee replacements have been developed to accommodate a large range of motion (ROM > 120°) after total knee arthroplasty (TKA). Femoral rollback or posterior translation of the femoral condyles during knee flexion is essential to maximise ROM and to avoid bone-implant impingement during deep knee flexion. The posterior cruciate ligament (PCL) has been described as the main contributor to femoral rollback. In posterior-stabilised TKA designs the PCL is substituted by a post-cam mechanism. The main objective of this study was to analyse the mechanical interaction between the PCL and a highflexion cruciate-retaining knee replacement during deep knee flexion. For this purpose, the mechanical performance of the high-flexion cruciate-retaining TKA design was evaluated and compared with two control designs including a highflexion posterior-stabilised design. Materials & Methods: Prosthetic knee kinematics and kinetics were computed using a three-dimensional dynamic finite element (FE) model of the knee joint. The FE knee model consisted of a distal femur, a proximal tibia and fibula, a quadriceps and patella tendon, a non-resurfaced patella, TKA components and a posterior cruciate ligament in case cruciate-retaining designs were evaluated. Tibio-femoral and patello-femoral contact were defined in the FE knee model and the polyethylene insert was modelled as a non-linear elastic-plastic material. Three different rotating platform TKA systems were analysed in this study: the high-flexion cruciate-retaining PFC Sigma CR150, the high-flexion posterior-stabilised PFC Sigma RP-F and the conventional cruciate-retaining PFC Sigma RP (Depuy, J& J, UK). Both the polyethylene stress characteristics and the tibio-femoral contact locations were evaluated during a squatting movement (ROM = 50° – 150°). Results: During deep knee flexion (ROM > 120°), the high-flexion cruciate-retaining TKA design showed a lower peak contact stress (74.7 MPa) than the conventional cruciate-retaining design (96.5 MPa). The posterior-stabilized high-flexion TKA design demonstrated the lowest peak contact stress at the condylar contact interface (54.2 MPa), although the post was loaded higher (77.4 MPa). All three TKA designs produced femoral rollback in the normal flexion range (ROM ≤ 120°), whereas the cruciate-retaining designs showed a paradoxical anterior movement of the femoral condyles during high-flexion. Discussion: PCL retention is a challenging surgical aim and affects the prosthetic knee load and kinematics as shown in this study. In addition, for adequate functioning the PCL should not be too tight or too lax after surgery. Hence, we investigated the effect of PCL laxity on the prosthetic performance and the best-balanced PCL was used in our simulations. Although PCL balancing is not an issue for posterior-stabilized TKA, we found the tibial post to be loaded relatively high for this implant type


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 439 - 439
1 Nov 2011
Swank M
Full Access

Introduction: Much debate exists regarding sparing or sacrificing the posterior cruciate ligament (PCL). The posterior cruciate ligament is said to maintain proprioception and stabilization post knee arthroplasty. Substitution of the PCL can require more femoral bone resection, but is thought to improve range of motion. Release of the PCL can restore extension and enhance flexion through greater femoral rollback. Bicruciate implants potentially offer greater flexion and enhanced stability. Each implant design with mechanical instruments requires a different surgical technique making it difficult to directly compare the patient and surgical outcomes. Computer navigation eliminates the differences in implantation between the various implant designs and theoretically allows a more direct comparison of implants based on design characteristics and not surgical technique. The purpose of this paper is to review four different implant designs implanted by a single surgeon with a computer assisted, gap balancing technique to determine if there was any difference in patient outcome. Methods: A total of 504 implants consisting of posterior cruciate sparing (PFC-RP), PCL substituting (PFC-RPC), PCL sacrificing (LCS) and bicruciate (Journey) implants performed by a single surgeon were reviewed. The PFC-RP group (260) was the largest, followed by the LCS (124), the PFC-RPF (80) and the Journey Knee (40). Outcomes reviewed were range of motion, function, pain and radiographic data to include alignment and evidence of radiolucency. Results: Demographic data of groups compared included 175 men and 329 women. Mean ages ranged from 61 to 74 years. Preoperative scores among all groups were similar with the cruciate substituting group slightly lower in function, flexion and with more pain before surgery. Overall function improved across all groups through two years, with better scores in the Journey and LCS implants (77 and 73 points) versus RPF (47) and PFC retaining group at (68) at one year (A perfect score is 100). Flexion values were comparable between all groups at one and two year intervals with Journey the highest mean flexion (116 degrees) at one year and with the PFC-RP offering the highest mean flexion at the two year mark (115 degrees). The RPF group at the one year mark had more pain overall (28) versus the other three groups (Journey 45, LCS 42, Sigma RP 45). No patients in any group were revised for instability. Other surgical complications were equal in each group. Discussion: While the PCL substituting knee patients (PFC-RPF) had lower pain, function and flexion at 12 months compared to all other groups, they started with lower overall knee scores. After accounting for the differences in patients preoperatively, no difference could be found between implant designs when implanted with a similar surgical technique employing a computer assisted gap balancing protocol


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 30 - 30
1 Jan 2003
Kadoya Y Kobayashi A Inui K Yamano Y
Full Access

The role of posterior cruciate ligament (PCL) in total knee replacement (TKR) has been a matter of debate for long time and remains controversial. In this study, the effect of posterior cruciate ligament (PCL) sacrifice on the tibiofemoral joint gap was analysed in 30 varus osteoarthritic knees undergoing posterior stabilized total knee replacement. Medial soft tissue was released and bone cut was made without preserving the bone segment of tibial PCL insertion. Then the medial and lateral joint gaps in full extension and 90□& lsaquo; flexion were measured before and after PCL sacrifice using a tensioning device (V-STAT tensor(tm), Zimmer). After PCL sacrifice, the flexion gap significantly increased both in medial and lateral side (4.8 □} 0.4 and 4.5 □} 0.4 mm respectively, mean □} SE) compared to those seen in the extension gap (0.9 □} 0.2 and 0.8 □} 0.2 mm, p < 0.001 ANOVA). There was no significant difference between the changes in the medial and lateral gap (p = 0.493). In conclusion, results of this intraoperative measurement showed that PCL sacrifice leads to a selective increase in the size of flexion gap by an average of 4.7 mm whereas it had little impact on the correction of varus deformity. These findings provided insights as for the role and necessity of PCL sacrifice in the correction of varus and flexion deformity. Because the flexion gap surpassed the unchanged extension gap during PCL sacrifice, PCL release could be used as a surgical technique to balance the gaps without additional bone cut


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 9 | Pages 1169 - 1172
1 Sep 2006
Khanduja V Somayaji HS Harnett P Utukuri M Dowd GSE

We report a retrospective analysis of the results of combined arthroscopically-assisted posterior cruciate ligament reconstruction and open reconstruction of the posterolateral corner in 19 patients with chronic (three or more months) symptomatic instability and pain in the knee. All the operations were performed between 1996 and 2003 and all the patients were assessed pre- and post-operatively by physical examination and by applying three different ligament rating scores. All also had weight-bearing radiographs, MR scans and an examination under anaesthesia and arthroscopy pre-operatively. The posterior cruciate ligament reconstruction was performed using an arthroscopically-assisted single anterolateral bundle technique and the posterolateral corner structures were reconstructed using an open Larson type of tenodesis. The mean follow up was 66.8 months (24 to 110). Pre-operatively, all the patients had a grade III posterior sag according to Clancy and demonstrated more than 20° of external rotation compared with the opposite normal knee on the Dial test. Post-operatively, seven patients (37%) had no residual posterior sag, 11 (58%) had a grade I posterior sag and one (5%) had a grade II posterior sag. In five patients (26%) there was persistent minimal posterolateral laxity. The Lysholm score improved from a mean of 41.2 (28 to 53) to 76.5 (57 to 100) (p = 0.0001) and the Tegner score from a mean of 2.6 (1 to 4) to 6.4 (4 to 9) (p = 0.0001). We conclude that while a combined reconstruction of chronic posterior cruciate ligament and posterolateral corner instability improves the function of the knee, it does not restore complete stability


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 3 | Pages 450 - 456
1 Apr 2004
Nakagawa S Johal P Pinskerova V Komatsu T Sosna A Williams A Freeman MAR

The posterior cruciate ligament (PCL) was imaged by MRI throughout flexion in neutral tibial rotation in six cadaver knees, which were also dissected, and in 20 unloaded and 13 loaded living (squatting) knees. The appearance of the ligament was the same in all three groups. In extension the ligament is curved concave-forwards. It is straight, fully out-to-length and approaching vertical from 60° to 120°, and curves convex-forwards over the roof of the intercondylar notch in full flexion. Throughout flexion the length of the ligament does not change, but the separations of its attachments do. We conclude that the PCL is not loaded in the unloaded cadaver knee and therefore, since its appearance in all three groups is the same, that it is also unloaded in the living knee during flexion. The posterior fibres may be an exception in hyperextension, probably being loaded either because of posterior femoral lift-off or because of the forward curvature of the PCL. These conclusions relate only to everyday life: none may be drawn with regard to more strenuous activities such as sport or in trauma


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 395 - 395
1 Dec 2013
Lee J Yoon J Lee J
Full Access

To investigate the effectiveness of avulsion fracture of tibial insertion of posterior cruciate ligament using the safe postero-medial approach through analyzing the clinical and radiographic outcomes. We treated 14 cases of acute PCL tibial avulsion fracture with “safe postero-medial approach”. The PCL and avulsion bony fragment was fixed with 1 cannuated screw and washer. The patients were assessed clinically and radiographically at 3 months, 6 months, and 12 months. Clinical examination for each visit included assessment of the knee range of motion, using goniometer and the posterior drawer test. The patients were evaluated according to the Lysholm and Tegner rating scales. Patients were followed-up for 12 to 16 months. X-ray showed that satisfactory reducdtion and bony healing was achieved in all cases. There was no neurovascular complication. All patients had negative posterior drawer tests. Excellent outcomes were reported by all patients with the Lysholm score system. And there was no signicant difference between the Tegner scores before injury and last follow-up. Surgical treatment of acute tibial avulsion fracture of the PCL with this approach can restore the stability and fuction of the joint safely in most patients without neurovascular complication. Therefore “safe postero-medial approach” may be suitable for the treatment of isolated tibial avulsion fracture of the PCL


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 4 | Pages 510 - 512
1 May 2001
Gill GS Joshi AB

We analysed the long-term results with a mean follow-up of 10.2 years, of 66 total knee replacements in 42 patients with rheumatoid arthritis. In all cases the posterior cruciate ligament was retained. There were only three complications (4.5%). Revision surgery was necessary in five knees (7.6%), including one (1.5%) with infection. At the final follow-up, 75.8% of knees were rated excellent clinically. Only 15% had an excellent function score. The survival rate of the implant was 90.7% at 19 years. The clinical, radiological and survivorship analysis shows that the posterior-cruciate-retaining knee arthroplasty performs well in rheumatoid arthritis