Advertisement for orthosearch.org.uk
Results 1 - 20 of 225
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 89 - 89
1 Jul 2022
Rajput V Iqbal S Salim M Anand S
Full Access

Abstract

Introduction

Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures

Methods

Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or headless screws either arthroscopically or mini-open arthrotomy. VMO plication or MPFL repair were done if necessary. MRI scan was done at follow-up to assess for healing of the fixed fragment prior to patient discharge.


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 6 | Pages 971 - 975
1 Nov 1998
McCaskie AW Deehan DJ Green TP Lock KR Thompson JR Harper WM Gregg PJ

Early implants for total knee replacement were fixed to bone with cement. No firm scientific reason has been given for the introduction of cementless knee replacement and the long-term survivorship of such implants has not shown any advantage over cemented forms. In a randomised, prospective study we have compared cemented and uncemented total knee replacement and report the results of 139 prostheses at five years. Outcome was assessed both clinically by independent examination using the Nottingham knee score and radiologically using the Knee Society scoring system. Independent statistical analysis of the data showed no significant difference between cemented and cementless fixation for pain, mobility or movement. There was no difference in the radiological alignment at five years, but there was a notable disparity in the radiolucent line score. With cemented fixation there was a significantly greater number of radiolucent lines on anteroposterior radiographs of the tibia and lateral radiographs of the femur. At five years, our clinical results would not support the use of the more expensive cementless fixation whereas the radiological results are of unknown significance. Longer follow-up will determine any changes in the results and conclusions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 9 - 9
1 Mar 2012
Pagoti R O'Brien S Doran E Beverland D
Full Access

A prospective study of 276 TKA's performed in patients with valgus knee deformity ≥ 10° using a Modified Surgical Technique. MATERIALS AND METHODS. Bone cuts were used to balance the valgus knee and soft tissue release was confined to the postero-lateral capsule in severe deformity. The aim was to restore a “functional mechanical axis” as opposed to a “neutral” mechanical axis. All surgeries were performed between Jan2003 and Apr2007, under the care of a single surgeon using an LCS rotating platform. All patients had full length radiographs and outcome scores collected prospectively. RESULTS. The mean coronal alignment of the lower limb was corrected from 15.9°(10-45°) to 3.8°. 94% patients had their coronal alignment restored to = 7°. Sixteen knees with postoperative valgus ≥8° were analysed as a separate group. The mechanical axis deviation was corrected from 52.3mm to 8.8mm. The distal femoral cut was made at 5° valgus in 131 knees(47.5%), 6° in 111 knees(40.2%) and 7° in 24 knees(8.7%).78 knees(28%) were balanced only with bone cuts. 198 knees(72%) had release of posterolateral capsule. 16 knees(5.8%) also had release of IT band. Lateral patellar release was performed in 39 knees (14%) and 23 knees had patella contouring. 93%knees had central patello-femoral alignment postoperatively. One spinout was managed by closed reduction and a second patient had revision of tibial tray for collapse. Patellar subluxation occurred in two patients. The oxford knee score and the American Knee Society clinical score improved from 48.5 to 26 and 21.04 to 86.03 respectively. CONCLUSION. Adequate correction of valgus knee deformity was successfully achieved using our modified technique with satisfactory short term outcome. It is our opinion that the extensive release of soft tissues is not only unnecessary but also fraught with the potential for instability


The Bone & Joint Journal
Vol. 100-B, Issue 10 | Pages 1336 - 1344
1 Oct 2018
Powell AJ Crua E Chong BC Gordon R McAuslan A Pitto RP Clatworthy MG

Aims

This study compares the PFC total knee arthroplasty (TKA) system in a prospective randomized control trial (RCT) of the mobile-bearing rotating-platform (RP) TKA against the fixed-bearing (FB) TKA. This is the largest RCT with the longest follow-up where cruciate-retaining PFC total knee arthroplasties are compared in a non-bilateral TKA study.

Patients and Methods

A total of 167 patients (190 knees with 23 bilateral cases), were recruited prospectively and randomly assigned, with 91 knees receiving the RP and 99 knees receiving FB. The mean age was 65.5 years (48 to 82), the mean body mass index (BMI) was 29.7 kg/m2 (20 to 52) and 73 patients were female. The Knee Society Score (KSS), Knee Society Functional Score (KSFS), Oxford Knee Score (OKS), Western Ontario and McMaster Universities Arthritis Index (WOMAC), and 12-Item Short-Form Health Survey Physical and Mental Component Scores (SF-12 PCS, SF-12 MCS) were gathered and recorded preoperatively, at five-years’ follow-up, and at ten years’ follow-up. Additionally, Knee Injury and Osteoarthritis Outcome Scores (KOOS) were collected at five- and ten-year follow-ups. The prevalence of radiolucent lines (RL) on radiographs and implant survival were recorded at five- and ten-year follow-ups.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 2 | Pages 194 - 199
1 Feb 2012
Hoffart H Langenstein E Vasak N

The aim of this prospective single-centre study was to assess the difference in clinical outcome between total knee replacement (TKR) using computerised navigation and that of conventional TKR. We hypothesised that navigation would give a better result at every stage within the first five years. A total of 195 patients (195 knees) with a mean age of 70.0 years (39 to 89) were allocated alternately into two treatment groups, which used either conventional instrumentation (group A, 97 knees) or a navigation system (group B, 98 knees). After five years, complete clinical scores were available for 121 patients (62%). A total of 18 patients were lost to follow-up. Compared with conventional surgery, navigated TKR resulted in a better mean Knee Society score (p = 0.008). The difference in mean Knee Society scores over time between the two groups was not constant (p = 0.006), which suggests that these groups differed in their response to surgery with time. No significant difference in the frequency of malalignment was seen between the two groups.

In summary, computerised navigation resulted in a better functional outcome at five years than conventional techniques. Given the similarity in mechanical alignment between the two groups, rotational alignment may prove to be a better method of identifying differences in clinical outcome after navigated surgery.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 54 - 54
7 Aug 2023
Kraus M Bingham J Kekic A Erickson C Grilli C Seamans D Upjohn D Hentz J Clarke H Spangehl M
Full Access

Abstract. Introduction. Adverse reactions to pain medication and pain can delay discharge after outpatient knee arthroplasty (TKA). Pharmacogenomics is an emerging tool that might help reduce adverse events by tailoring medication use based on known genetic variations in the CYP genes determining drug metabolism. This study was undertaken to evaluate whether pre-operative pharmacogenomic testing could optimize peri-operative pain management in patients undergoing total knee arthroplasty (TKA). Methods. This prospective, randomized study was performed in adults undergoing primary TKA. Patients in the experimental group underwent pre-operative pharmacogenomic evaluation and medication adjustments. Medications were not optimized for control patients. The Overall Benefit of Analgesic Score (OBAS) at 24 hours post-op was the primary outcome. Postoperative pain scores (VAS scale), total opioid use, time in recovery, and time to discharge were also compared. Results. 76 patients enrolled. 93% of patients had a poor-intermediate phenotype for at least one of four CYP genes. OBAS did not differ significantly between the two groups (4.2 control vs. 4.7 experimental; 95% CI −1.1 to 2.1) and was below the minimum clinically important difference of 2.0 points. Furthermore, there were no differences in any OBAS subscale including pain, satisfaction, or nausea. There were no differences in time in the recovery area or to discharge from hospital, or narcotic use. Conclusions. Despite many patients having a poor-intermediate phenotype for a CYP gene, pharmacogenomic testing prior to TKA and medication adjustment did not improve anesthesia or pain management outcomes, time to discharge or mean total opioid use after surgery


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 1 - 1
1 Jul 2012
Scott CEH Howie CR MacDonald D Biant LC
Full Access

Up to 20% of patients are not satisfied with the outcome following total knee replacement (TKR), but little is known about the predictors of this dissatisfaction. This study investigated the pre- and post-operative predictors of dissatisfaction in a large cohort of patients undergoing TKR. We assessed 1217 consecutive patients undergoing TKR between 2006 and 2008 both preoperatively and six months after surgery, using the Short-form (SF)-12 health questionnaire and the Oxford Knee Score.

Detailed co-morbidity information was also gathered. Satisfaction was measured at one year and 18.6% (226 of 1217) of patients were unsure or dissatisfied with their replacement, 81.4% (911 of 1217) were satisfied or very satisfied. Multivariate regression analysis was performed to identify independent predictors of dissatisfaction. Significant (p < 0.001) predictors of dissatisfaction at one year included the pre-operative SF-12 mental component score, the co-morbidities of depression and pain in other joints, and the six-month SF-12 score. The most significant independent predictor of dissatisfaction at 1 year was poor improvement in Oxford Knee Score pain element at 6 months. Patient expectations were highly correlated with satisfaction.

Satisfaction following TKR is multifactorial. Managing patient expectations and mental health may reduce dissatisfaction rates. However, the most significant predictor of dissatisfaction is a painful total knee replacement.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 55 - 55
1 Jul 2022
Mohamed MH Shetty A
Full Access

Abstract

Introduction

To compare the efficacy of adductor canal blocks (ACB) and periarticular anesthetic injections (PAI) with bupivacaine in total knee arthroplasty.

Methods

90 patients undergoing primary total knee arthroplasty under spinal anesthesia were randomized to 1 of 3 groups: ACB alone (15 mL of 0.5% bupivacaine), PAI alone (50 mL of 0.25% bupivacaine with epinephrine) and ACB + PAI. Primary outcome in this study was the visual analog scale (VAS) pain score in the immediate postoperative period. Secondary outcomes included postoperative opioid use, activity level during physiotheraphy, length of hospital stay and ROM.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 7 | Pages 905 - 908
1 Jul 2006
Hetsroni I Finestone A Milgrom C Sira DB Nyska M Radeva-Petrova D Ayalon M

Excessive foot pronation has been considered to be related to anterior knee pain. We undertook a prospective study to test the hypothesis that exertional anterior knee pain is related to the static and dynamic parameters of foot pronation. Two weeks before beginning basic training lasting for 14 weeks, 473 infantry recruits were enrolled into the study and underwent two-dimensional measurement of their subtalar joint displacement angle during walking on a treadmill. Of the 405 soldiers who finished the training 61 (15%) developed exertional anterior knee pain. No consistent association was found between the incidence of anterior knee pain and any of the parameters of foot pronation. While a statistically significant association was found between anterior knee pain and pronation velocity (left foot, p = 0.05; right foot, p = 0.007), the relationship was contradictory for the right and left foot. Our study does not support the hypothesis that anterior knee pain is related to excessive foot pronation


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 73 - 73
1 Oct 2018
Springer BD Bossi K Odum S Voellinger DC
Full Access

Introduction

Morbid obesity (BMI>40) is a significant risk factor for complications following total joint arthroplasty (TJA). As such many have a restrictive practice of withholding elective primary TJA in the morbidly obese. The purpose of this study was to observe the implications of this practice.

Methods

From 2012 to 2014, 289 patients with morbid obesity and end-stage OA of the hip or knee were prospectively followed. At initial visit, patients were given a packet on risks of TJA in the morbidly obese and referral information to a weight loss clinic. Patients were contacted at 6, 12, 18 and 24 months from initial visit for PROs, and BMI changes. The average age of patients was 56 (26.7–79.1) there were 218 females and 71 males.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 36 - 36
1 Oct 2018
Hamilton WG Brenkel I Barnett SL Allen PW Lesko J Dwyer K Kantor SR Clatworthy M
Full Access

Introduction

New implants for total knee arthroplasty (TKA) are frequently introduced with the promise of improved performance. Infrequently there is accompanying data to document relative performance. The goal of this study was to evaluate the outcomes of an implant widely used for decades (Existing TKA), compared to a new implant (New TKA) from the same manufacturer.

Methods

From October 2011-March 2015, 19 sites prospectively enrolled and implanted 752 Subjects with Existing TKA. Between November 2012 and May 2015, 23 sites (18 sites had enrolled Existing TKAs), implanted 1131 Subjects with the New TKA. Demographics were similar between groups. Subjects were seen preoperatively, <1-year, 1-year, and 2-years to collect patient reported outcome measures (PROMs), radiographs and any complications. PROMs consisted of Knee Injury and Osteoarthritis Outcome Score (KOOS) (permits WOMAC scoring), Oxford Knee Score (OKS), Patient's Knee Implant Performance (PKIP) and EQ5D-3L and a p-value of 0.01 was established for statistical significance for PROMs comparisons. Kaplan-Meier (KM) implant survivorship (revision of any component for any reason) estimates were calculated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 42 - 42
1 Jul 2012
Hassaballa M Murray J Robinson J Porteous A Newman J
Full Access

Introduction. Kneeling ability is better in unicompartmental than total knee arthroplasty. There is also an impression that mobile bearing knees achieve better functional outcome than their fixed bearing cousins in unicompartmental and to a lesser extent total joint arthroplasty. In the UK, the market leading unicompartmental replacement is mobile bearing. Aim. To analyse kneeling ability after total and unicompartmental knee replacement using mobile and fixed bearing inserts. Methods. In our department there are two prospective randomised studies (fixed versus mobile) in this area. For total knee arthroplasty, 207 TKR patients receiving the same prosthesis (Rotaglide, Corin, UK) were randomised into mobile bearing (102 patients, mean age of 53 years) or fixed bearing (105 patients, mean age of 55 years). Regarding unicondylar knees, data was collected on 352 UKR patients who received the same implant (Uniglide - previously known as AMC - Corin, UK). Within this group there was a randomised controlled trial of fixed v mobile bearings: 52 patients (mean age 62 years) had a mobile insert and 57 (mean age 65 yrs) had a fixed insert. Data was also collected on patients undergoing fixed bearing lateral unicondylar replacement (Uniglide). All patients completed the Oxford Knee Questionnaire preoperatively, 1 year and 2 years postoperatively, (where 0 = bad and 48 = good). There kneeling ability (question 7) and total Oxford scores were analysed. We are currently collecting objective data on post-operative kneeling ability with force plate analysis and subjective anterior knee-specific scoring systems. Results. Subjective kneeling ability: Oxford Knee Score Question 7 as range 0-4, where 4 = good. Conclusion. Both fixed and mobile UKR and TKR have good outcome. No group produced good kneeling ability, but there was a modest improvement in all groups from the preoperative kneeling scores. Fixed bearing knee replacement showed better outcome than mobile bearing knees, in both UKR and TKR groups


Aims. The aim of this study was to compare the preinjury functional scores with the postinjury preoperative score and postoperative outcome scores following anterior cruciate ligament (ACL) reconstruction surgery (ACLR). Methods. We performed a prospective study on patients who underwent primary ACLR by a single surgeon at a single centre between October 2010 and January 2018. Preoperative preinjury scores were collected at time of first assessment after the index injury. Preoperative (pre- and post-injury), one-year, and two-year postoperative functional outcomes were assessed by using the Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm Knee Score, and Tegner Activity Scale. Results. We enrolled 308 males and 263 females of mean age 27 years (19 to 46). The mean preinjury and preoperative post-injury Lysholm Knee Scores were 94 (73 to 100) and 63 (25 to 85), respectively, while the respective mean scores at one and two years postoperatively were 84 (71 to 100) and 89 (71 to 100; p < 0.001). The mean Tegner preinjury and preoperative post-injury scores were 7 (3 to 9) and 3 (0 to 6), respectively, while the respective mean scores at one and two years postoperatively were 6 (1 to 8) and 6 (1 to 9) (p < 0.001). The mean KOOS scores at preinjury versus two years postoperatively were: symptoms (96 vs 84); pain (94 vs 87); activities of daily living (97 vs 91), sports and recreation function (84 vs 71), and quality of life (82 vs 69), respectively (p < 0.001). Conclusion. Functional scores improved following ACLR surgery at two years in comparison to preoperative post-injury scores. However, at two-year follow-up, the majority of patients failed to achieve their preinjury scores. The evaluation of ACLR outcomes needs to consider the preinjury scores rather than the immediate preoperative score that is usually collected. Cite this article: Bone Jt Open 2023;4(1):46–52


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 680 - 687
1 Jul 2024
Mancino F Fontalis A Grandhi TSP Magan A Plastow R Kayani B Haddad FS

Aims. Robotic arm-assisted surgery offers accurate and reproducible guidance in component positioning and assessment of soft-tissue tensioning during knee arthroplasty, but the feasibility and early outcomes when using this technology for revision surgery remain unknown. The objective of this study was to compare the outcomes of robotic arm-assisted revision of unicompartmental knee arthroplasty (UKA) to total knee arthroplasty (TKA) versus primary robotic arm-assisted TKA at short-term follow-up. Methods. This prospective study included 16 patients undergoing robotic arm-assisted revision of UKA to TKA versus 35 matched patients receiving robotic arm-assisted primary TKA. In all study patients, the following data were recorded: operating time, polyethylene liner size, change in haemoglobin concentration (g/dl), length of inpatient stay, postoperative complications, and hip-knee-ankle (HKA) alignment. All procedures were performed using the principles of functional alignment. At most recent follow-up, range of motion (ROM), Forgotten Joint Score (FJS), and Oxford Knee Score (OKS) were collected. Mean follow-up time was 21 months (6 to 36). Results. There were no differences between the two treatment groups with regard to mean change in haemoglobin concentration (p = 0.477), length of stay (LOS, p = 0.172), mean polyethylene thickness (p = 0.065), or postoperative complication rates (p = 0.295). At the most recent follow-up, the primary robotic arm-assisted TKA group had a statistically significantly improved OKS compared with the revision UKA to TKA group (44.6 (SD 2.7) vs 42.3 (SD 2.5); p = 0.004) but there was no difference in the overall ROM (p = 0.056) or FJS between the two treatment groups (86.1 (SD 9.6) vs 84.1 (4.9); p = 0.439). Conclusion. Robotic arm-assisted revision of UKA to TKA was associated with comparable intraoperative blood loss, early postoperative rehabilitation, functional outcomes, and complications to primary robotic TKA at short-term follow-up. Robotic arm-assisted surgery offers a safe and reproducible technique for revising failed UKA to TKA. Cite this article: Bone Joint J 2024;106-B(7):680–687


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 83 - 83
7 Aug 2023
Sidhu GAS
Full Access

Abstract. Introduction. Multiple strategies, used either in isolation or combination, are available to reduce the need for post-operative blood transfusion in joint replacements. Amongst them, the use of tranexamic acid (TXA) has been rising and this study was conducted to compare the efficacy of topical and intravenous TXA in bilateral total knee replacement patients. Materials and methods. Randomised prospective study with 120 patients (male: female: 25:95) undergoing bilateral TKA. Patients were divided into two groups A and B after computer randomization, who received intravenous or topical (intra-articular) TXA respectively. Results. The average haemoglobin loss in intravenous group was 90.2379 g/L as compared to 39.137 g/L in topical group (p < 0.005). Moreover, there was reduction in blood loss in topical (330.1602 ml) as compared to intravenous group (764.9622 ml). The blood transfusion rate was more for the intravenous group (average 1.73 units) than for the topical group (average 0.75, unit). WOMAC score at 6 weeks in the intravenous group was 12.50, and in the topical group was 7.23 (p value < 0.001). Conclusion. Topical TXA is better than intravenous TXA for reduction of blood loss, which also reduces the need for blood transfusion in bilateral TKA patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 87 - 87
7 Aug 2023
Ahmed I Dhaif F Khatri C Parsons N Hutchinson C Staniszewska S Price A Metcalfe A
Full Access

Abstract. Background. Meniscal tears affect 222 per 100,000 of the population and can be managed non-operatively or operatively with an arthroscopic partial meniscectomy (APM), meniscal repair or meniscal transplantation. The purpose of this review is to summarise the outcomes following treatment with a meniscal tear and explore correlations between outcomes. Methodology. A systematic review was performed of MEDLINE, EMBASE, AMED and the Cochrane Central Register of Controlled Trials to identify prospective studies describing the outcomes of patients with a meniscal tear. Comparisons were made of outcomes between APM and non-operative groups. Outcomes were graphically presented over time for all treatment interventions. Pearson's correlations were calculated between outcome timepoints. Results. 35 studies were included, 28 reported outcomes following APM; four following meniscal repair and three following meniscal transplant. Graphical plots demonstrated a sustained improvement for all treatment interventions. A moderate to very strong correlation was reported between baseline and three-month outcomes. In the medium term, there was small significant difference in outcome between APM and non-operative measures (SMD 0.17; 95 % CI 0.04, 0.29), however, this was not clinically significant. Conclusions. Patients with a meniscal tear demonstrated a sustained initial improvement in function scores, which was true of all treatments examined. APM may have little benefit in older people, however, previous trials did not include patients who meet the current indications for surgery as a result the findings should not be generalised to all patients with a meniscal tear. Further trials are required in patients who meet current operative indications


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 22 - 22
7 Aug 2023
Reason L Roberton A Jonas S Phillips J
Full Access

Abstract. Introduction. Little is known about employment following revision total knee arthroplasty (RTKA). This study aims to describe factors associated with returning to employment in patients of working age who underwent RTKA surgery. Methodology. We performed a retrospective assessment of all patients aged ≤65 who underwent RTKA at our NHS institution between 2006 and 2020. All indications and revision procedures were included. Pre-operative demographics, indication for surgery and Oxford Knee Scores (OKS) were recorded. Postal questionnaires were sent to patients including patient reported outcome measures and departmental questionnaire asking patients about employment status pre- and post-operatively. Results. 132 procedures were performed in 113 patients. Median follow up was 5.5 years (2.4–9.0). Mean age was 58 (5.8) and 50% (57) were male. 62 patients undergoing 74 procedures responded to postal questionnaires and were included in the study. 53% (33) were employed prior to surgery and 61% (38) returned to work at a median of 12 weeks (3–150). Of the 24 who did not return to work, 7 reported intending to return to work. Those patients who returned to work had increased pre-operative OKS (16.9 vs 13.6) and mean improvement (16.5 vs 12.4). Conclusion. This study is limited by small numbers and its observational nature. In this population the majority of patients who wished to return to work after RTKA were able to do so. This provides some reassurance when counselling patients. Prospective studies to better understand the factors that predict return to work will be important with increasing demands from surgery


Bone & Joint Open
Vol. 4, Issue 10 | Pages 808 - 816
24 Oct 2023
Scott CEH Snowden GT Cawley W Bell KR MacDonald DJ Macpherson GJ Yapp LZ Clement ND

Aims. This prospective study reports longitudinal, within-patient, patient-reported outcome measures (PROMs) over a 15-year period following cemented single radius total knee arthroplasty (TKA). Secondary aims included reporting PROMs trajectory, 15-year implant survival, and patient attrition from follow-up. Methods. From 2006 to 2007, 462 consecutive cemented cruciate-retaining Triathlon TKAs were implanted in 426 patients (mean age 69 years (21 to 89); 290 (62.7%) female). PROMs (12-item Short Form Survey (SF-12), Oxford Knee Score (OKS), and satisfaction) were assessed preoperatively and at one, five, ten, and 15 years. Kaplan-Meier survival and univariate analysis were performed. Results. At 15 years, 28 patients were lost to follow-up (6.1%) and 221 patients (51.9%) had died, with the mean age of the remaining cohort reducing by four years. PROMs response rates among surviving patients were: one-year 63%; five-year 72%; ten-year 94%; and 15-year 59%. OKS and SF-12 scores changed significantly over 15 years (p < 0.001). The mean improvement in OKS was 18.8 (95% confidence (CI) 16.7 to 19.0) at one year. OKS peaked at five years (median 43 years) declining thereafter (p < 0.001), though at 15 years it remained 17.5 better than preoperatively. Age and sex did not alter this trajectory. A quarter of patients experienced a clinically significant decline (≥ 7) in OKS from five to ten years and from ten to 15 years. The SF-12 physical component score displayed a similar trajectory, peaking at one year (p < 0.001). Patient satisfaction was 88% at one, five, and ten years, and 94% at 15 years. In all, 15-year Kaplan-Meier survival was 97.6% (95% CI 96.0% to 99.2%) for any revision, and 98.9% (95% CI 97.9% to 99.9%) for aseptic revision. Conclusion. Improvements in PROMs were significant and maintained following single radius TKA, with OKS peaking at five years, and generic physical health peaking at one year. Patient satisfaction remained high at 15 years, at which point 2.4% had been revised. Cite this article: Bone Jt Open 2023;4(10):808–816


The Bone & Joint Journal
Vol. 104-B, Issue 9 | Pages 1047 - 1051
1 Sep 2022
Balato G Dall’Anese R Balboni F Ascione T Pezzati P Bartolini G Quercioli M Baldini A

Aims. The diagnosis of periprosthetic joint infection (PJI) continues to present a significant clinical challenge. New biomarkers have been proposed to support clinical decision-making; among them, synovial fluid alpha-defensin has gained interest. Current research methodology suggests reference methods are needed to establish solid evidence for use of the test. This prospective study aims to evaluate the diagnostic accuracy of high-performance liquid chromatography coupled with the mass spectrometry (LC-MS) method to detect alpha-defensin in synovial fluid. Methods. Between October 2017 and September 2019, we collected synovial fluid samples from patients scheduled to undergo revision surgery for painful total knee arthroplasty (TKA). The International Consensus Meeting criteria were used to classify 33 PJIs and 92 aseptic joints. LC-MS assay was performed to measure alpha-defensin in synovial fluid of all included patients. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic curve (AUC) were calculated to define the test diagnostic accuracy. Results. The AUC was 0.99 (95% confidence interval (CI) 0.98 to 1.00). Receiver operating characteristic (ROC) analysis showed that the optimal cut-off value of synovial fluid alpha-defensin was 1.0 μg/l. The sensitivity of alpha-defensin was 100% (95% CI 96 to 100), the specificity was 97% (95% CI 90 to 98), the positive predictive value was 89.2% (95% CI 82 to 94), and negative predictive value was 100% (95% CI 96 to 100). ROC analysis demonstrated an AUC of 0.99 (95% CI 0.98 to 1.0). Conclusion. The present study confirms the utility of alpha-defensin in the synovial fluid in patients with painful TKA to select cases of PJI. Since LC-MS is still a time-consuming technology and is available in highly specialized laboratories, further translational research studies are needed to take this evidence into routine procedures and promote a new diagnostic approach. Cite this article: Bone Joint J 2022;104-B(9):1047–1051


Bone & Joint Research
Vol. 12, Issue 5 | Pages 313 - 320
8 May 2023
Saiki Y Kabata T Ojima T Kajino Y Kubo N Tsuchiya H

Aims. We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. Methods. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland–Altman analyses to evaluate the agreement and error between radiography and the other measurements. Results. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R. 2. of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. Conclusion. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner’s skills. Cite this article: Bone Joint Res 2023;12(5):313–320