Introduction. The productivity of trainees, consultants and institutions is frequently judged by the quantity of articles published in medical journals. While personnel may change, an institution should pride itself on its
Duplicate
Background. Presentations at national meetings provide an important forum to relay research findings in all areas of Orthopaedic surgery. Orthopaedic surgical trainees are encouraged throughout the training process to participate, present and ultimately publish their research. Indeed the well known mantra ‘Publish or Perish’ signifies the pressure trainees are sometimes placed under in order to achieve professional success. The number of original published papers is often the yardstick by which professional appointments are made. We aimed to determine the overall
NICE published the guidelines ‘Selection of prostheses for primary hip replacement’ in 2000. Essentially these guidelines made two recommendations: firstly to use prostheses which had attained the ‘10 year benchmark’ of a revision rate of 10% or less at 10 years, or had a minimum of three years revision rate experience that was on target to reach this benchmark; and secondly to use cemented hip prostheses to the exclusion of uncemented and hybrid prostheses. The information from the Trent Regional Arthroplasty Study (TRAS) has been used to retrospectively examine the types of hip prostheses used from 1990 – 2005, and assess the impact that the NICE guidelines have had on orthopaedic practice. This study revealed that the percentage of prostheses used which attained the ‘ten year benchmark’ has increased since the guidelines were published. In 2001, of the ten cups, which constituted 80% of the acetabular components used, only three attained this NICE benchmark, but by 2005 this number had risen to eight. Similarly in 2001, of the eight stems, which constituted almost 80% of the femoral components used, only five attained this NICE benchmark. In 2005 seven out of these eight stems had attained the minimum standard. However contrary to the recommendation made by NICE in 2000, to use cemented prostheses, the results indicate the use of uncemented prostheses has trebled (from 6.7% to 19.2%, n= 137 and 632 respectively), and the use of hybrid prostheses has more than doubled (from 8.8% to 22% of all prostheses, n= 181 and 722 respectively) since the guidelines were published. Therefore the recommendations made by NICE are not being followed, which calls the value of NICE guidelines into question.
The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized controlled trial (RCT) and to study patterns of change between subspecialties and nationalities. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the
Aim. The number of periprosthetic joint infections (PJI) is increasing due to ageing population and increasing numbers of arthroplasty procedures and treatment is costly. Aim of the study was to analyze the direct healthcare costs of PJI in Europe for total hip arthroplasties (THA) and total knee arthroplasties (TKA). Method. A systematic review in PubMed with search of direct costs of PJI in European countries was performed. Thereby the term cost* AND (infection OR PJI) AND (prosthesis OR knee OR hip OR “TKA” OR “THA” OR arthroplast*) was combined with each European country to detect relevant
Background and purpose. Previous
Aims. The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized contolled trial (RCT) and to study patterns of change between subspecialties and nationalities. Methods. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the
Conferences centered around surgery suffers from gender disparity with male faculty having a more dominant presence in meetings compared to female faculty. Orthopedic Surgery possibly suffers the most from this problem of all surgical specialties, and is reflective of a gender disparity in the field. The objective of this study was to investigate the prevalence of “manels”, or male-only sessions, in eight major Orthopedic Surgery meetings hosted in 2021 and to quantify the differences in location of practice, academic position, years of practice, and research qualifications between male and female faculty. Eight Orthopedic conferences organized by major Orthopedic associations (AAOS, COA, OTA, EFORT, AAHKS, ORS, NASS, and AOSSM) from February 2021 to November 2021 were analyzed. Meeting information was retrieved from the conference agendas, and details of chairs and speakers were obtained from Linkedin, Doximity, CPSO, personal websites, and Web of Science. Primary outcomes included: one) percentage of male faculty in all included sessions and two) overall percentage of manels. Secondary outcomes included one) percentage of male speakers and chairs in all included sessions, two) overall percentage of male-chair and male-speaker only sessions. Comparisons for outcomes were made between conferences and session topics (adult reconstruction hip, adult reconstruction knee, practice management/rehabilitation, trauma, sports, general, pediatrics, upper extremity, musculoskeletal oncology, foot and ankle, spine, and miscellaneous). Mean number of sessions for male and female were compared after being stratified into quartiles based on
Aims. Systematic reviews of randomized controlled trials (RCTs) are the highest level of evidence used to inform patient care. However, it has been suggested that the quality of randomization in RCTs in orthopaedic surgery may be low. This study aims to describe the quality of randomization in trials included in systematic reviews in orthopaedic surgery. Methods. Systematic reviews of RCTs testing orthopaedic procedures published in 2022 were extracted from PubMed, Embase, and the Cochrane Library. A random sample of 100 systematic reviews was selected, and all included RCTs were retrieved. To be eligible for inclusion, systematic reviews must have tested an orthopaedic procedure as the primary intervention, included at least one study identified as a RCT, been published in 2022 in English, and included human clinical trials. The Cochrane Risk of Bias-2 Tool was used to assess random sequence generation as ‘adequate’, ‘inadequate’, or ‘no information’; we then calculated the proportion of trials in each category. We also collected data to test the association between these categories and characteristics of the RCTs and systematic reviews. Results. We included 917 unique RCTs. We found that 374 RCTs (40.8%) reported adequate sequence generation, 61 (6.7%) were inadequate, 410 (44.7%) lacked information, and 72 (7.9%) were observational studies incorrectly included as RCTs within the systematic review.
Introduction and aims. The International Orthopaedic community is eagerly adopting Robotic Assisted Arthroplasty (RAA) technology. However, the evidence for the benefits of this technology are unproven and at best equivocal. This study is a comprehensive bibliometric analysis of all published research in the field of RAA. Methods. A systematic literature search was conducted to retrieve all peer-reviewed, English language,
Introduction. We present a case of a 49-year-old patient who initially presented in May 2020 with an open pilon fracture. Managed with initial debridement, fixation and flap - who subsequently underwent circular frame application for failure of fixation, requiring a transport to fusion frame who developed beta-haemolytic streptococcus A within the site of the proximal corticotomy. Materials & Methods. A systematic review of the literature was conducted searching EMBASE, MEDLINE and Cochrane library for all articles discussing infected bone regenerate- a paucity of information was found. Abstracts were independently reviewed by 2 authors (LH and LT). In total, there were 16 papers, and then subsequently analysed we identified two case reports regarding infected regenerate. Results. Developing an infection in a regenerate is highly rare with very few reported cases within the published literature. The literature identified risk factors for an infected regenerate, with open fracture and smoking being the two consistent factors. The open fracture deep infection rate is cited at 10% in most
Introduction. Various biomaterials and bone graft substitute technologies for use in osteomyelitis treatment are currently used in clinal practice. They vary in mode of action (with or without antibiotics) and clinical application (one-stage or two-stage surgery). This systematic review aims to compare the clinical evidence of different synthetic antimicrobial bone graft substitutes and antibiotic-loaded carriers in eradicating infection and clinical outcome in patients with chronic osteomyelitis. Methods. Systematic review according to PRISMA statement on
Periprosthetic joint infection (PJI) in geriatric and/or multimorbid patients is an enormous challenge for orthopaedic surgeons. Revision procedures have also been demonstrated to expose patients to higher infection risks. Prior patient stratification according to presumed infection risks, followed by a more potent local antibiotic prophylaxis protocol with selective use of DALBC, is an interesting strategy to decrease the burden of PJI in high risk patients. The PubMed & EMBASE databases were screened for
Accurate measurement of pelvic tilt (PT) is critical in diagnosing hip and spine pathologies. Yet a sagittal pelvic radiograph with good quality is not always available. Studies explored the correlation between PT and sacro-femoral-pubic (SFP) angle from anteroposterior (AP) radiographs yet demonstrated conflicting conclusions about its feasibilities. This study aims to perform a cohort-controlled meta-analysis to examine the correlation between the SFP angle and PT and proposes an application range of the method. This study searched PubMed, Embase, Cochrane, and Web of Science databases for studies that evaluated the correlation between SFP angle and PT. The Pearson's correlation coefficient r from studies were tabulated and compared. Pooled r for overall and gender/age (teenage or adult) controlled subgroup were reported using Fisher's Z transformation. Heterogeneity and
Introduction and aims. Robotic Assisted Arthroplasty (RAA) is increasingly proliferative in the international orthopaedic environment. Traditional bibliometric methods poorly assess the impact of surgical innovations such as robotic technology. Progressive Scholarly Acceptance (PSA) is a new model of bibliographic analysis which quantitatively evaluates the impact of robotic technology in the orthopaedic scientific community. Methods. A systematic literature search was conducted to retrieve all peer-reviewed, English language
Introduction. Compartment syndrome can be a life changing consequence of injury to a limb. If not diagnosed and treated early it can lead to permanent disability. Neurovascular observations done on the ward by nursing staff, are often our early warning system to those developing compartment syndrome. But are these adequate for detecting the early signs of compartment syndrome? Our aim was to compare the quality and variability of charts across the UK major trauma network. Materials & Methods. All major trauma centres in England and Scotland were invited to supply a copy of the neurovascular chart routinely used. We assessed how such charts record relevant information. Specific primary data points included were pain scores, analgesia requirements, pain on passive stretch and decreased sensation in the first web space specifically. As secondary objectives, we assessed how late signs were recorded, whether clear instructions were included, quantitative scores and the use of regional blocks recorded. Results. A response rate of 46% was achieved. Of the charts reviewed, 25% documented pain scores or pain on passive movement. Pain on movement and analgesia requirements were documented in 33% and 8% respectively. Specific sensation within the 1. st. webspace was recorded in 16%. No charts recorded use of regional block. All charts recorded global sensation, movement (unspecified), pulse and colour whilst 66% documented capillary refill and 83% temperature. Instructions were included in 41% of charts. Conclusions. In 2016, the BOA supported
Specific brace-fitting complications in idiopathic congenital talipes equinovarus (CTEV) have been rarely described in published series, and usually focus on non-compliance. Our primary aim was to compare the rate of persistent pressure sores in patients fitted with Markell boots and Mitchell boots. Our additional aims were to describe the frequency of other brace fitting complications and identify age trends in these complications. A retrospective analysis of medical files of 247 idiopathic CTEV patients born between 01/01/2010 - 01/01/2021 was performed. Data was collected using a REDCap database. Pressure sores of sufficient severity for clinician to recommend time out of brace occurred in 22.9% of Mitchell boot and 12.6% of Markell boot patients (X. 2. =6.9, p=0.009). The overall rate of bracing complications was 51.4%. 33.2% of parents admitted to bracing non-compliance and 31.2% of patients required re-casting during the bracing period for relapse. For patients with a minimum follow-up of age 6 years, 44.2% required tibialis anterior tendon transfer. Parents admitting to non-compliance were significantly more likely to have a child who required tibialis anterior tendon transfer (X. 2. =5.71, p=0.017). Overall rate of capsular release (posteromedial release or posterior release) was 2.0%. Neither medium nor longterm results of Ponseti treatment in the Australian and New Zealand clubfoot have been published. Globally, few
Introduction. A greater emphasis has been placed on fracture related infection (FRI) orthopaedic practice as a separate entity in recent years. Since the
Aim. Prosthetic joint infections pose a major clinical challenge. Developing novel material surface technologies for orthopedic implants that prevent bacterial adhesion and biofilm formation is essential. Antimicrobial coatings applicable to articulating implant surfaces are limited, due to the articulation mechanics inducing wear, coating degradation, and toxic particle release. Noble metals are known for their antimicrobial activity and high mechanical strength and could be a viable coating alternative for orthopaedic implants [1]. In this study, the potential of thin platinum-based metal alloy coatings was developed, characterized, and tested on cytotoxicity and antibacterial properties. Method. Three platinum-based metal alloy coatings were sputter-coated on medical-grade polished titanium discs. The coatings were characterized using optical topography and scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS). Ion release was measured using inductively coupled plasma optical emission spectrometry (ICP-OES). Cytotoxicity was tested according to ISO10993-5 using mouse fibroblasts (cell lines L929 and 3T3). Antibacterial surface activity, bacterial adhesion, bacterial proliferation, and biofilm formation were tested with gram-positive Staphylococcus aureus ATCC 25923 and gram-negative Escherichia coli ATCC 25922. Colony forming unit (CFU) counts, live-dead fluorescence staining, and SEM-EDS images were used to assess antibacterial activity. Results. Three different platinum-based metal alloys consisting of platinum-iridium, platinum-copper, and platinum-zirconium. The coatings were found 80 nm thick, smooth (roughness average < 60 nm), and non-toxic. The platinum-copper coating showed a CFU reduction larger than one logarithm in adherent bacteria compared to uncoated titanium. The other coatings showed a smaller reduction. This data was confirmed by SEM and live-dead fluorescence images, and accordingly, ICP-OES measurements showed low levels of metal ion release from the coatings. Conclusions. The platinum-copper coating showed low anti-adhesion properties, even with extremely low metal ions released. These platinum-based metal alloy coatings cannot be classified as antimicrobial yet. Further optimization of the coating composition to induce a higher ion release based on the galvanic principle is required and copper looks most promising as the antimicrobial compound of choice. Acknowledgments. This