Aims. We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any
Aims. Post-operative migration of cemented acetabular components as
measured by radiostereometric analysis (RSA) has a strong predictive
power for late, aseptic loosening. Also,
A total of 397 hips were randomised to receive
Metasul metal-on-metal (MoM), metal-on-conventional polyethylene (MoP)
or ceramic-on-polyethylene (CoP) bearings using a cemented triple-tapered
polished femoral component (MS-30). There were 129 MoM hips in 123
patients (39 male and 84 female, mean age 63.3 years (40.7 to 72.9)),
137 MoP hips in 127 patients (39 male and 88 female, mean age 62.8
years (24.5 to 72.7)) and 131 CoP hips in 124 patients (51 male
and 73 female, mean age 63.9 years (30.6 to 73.8)). All acetabular
components were cemented Weber polyethylene components with the
appropriate inlay for the MoM articulation. Clinical evaluation
was undertaken using the Harris hip score (HHS) and radiological
assessments were made at two, five and seven years. The HHS and radiological
analysis were available for 341 hips after seven years. The MoM
group had the lowest mean HHS (p = 0.124), a higher rate of revision
(p <
0.001) and a higher incidence of
When
We studied 185 total hip replacements and related the identification of
The highly cross-linked polyethylene Exeter RimFit flanged cemented
acetabular component was introduced in the United Kingdom in 2010.
This study aimed to examine the rates of emergence of radiolucent
lines observed when the Rimfit acetabular component was implanted
at total hip arthroplasty (THA) using two different techniques: firstly,
the ‘rimcutter’ technique in which the flange sits on a pre-prepared
acetabular rim; and secondly, the ‘trimmed flange’ technique in
which the flange is trimmed and the acetabular component is seated
inside the rim of the acetabulum. The radiographs of 150 THAs (75 ‘rimcutter’, 75 ‘trimmed flange’)
involving this component were evaluated to assess for radiolucencies
at the cement/bone interface by three observers. Aims
Patients and Methods
Aims. Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. Methods. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis. Results. Results from mixed model analyses revealed a lower mean retroversion for line-to-line (0.72° (95% confidence interval (CI) 0.38° to 1.07°; p < 0.001), but no significant differences in subsidence between the techniques (-0.15 mm (95% CI -0.53 to 0.227; p = 0.429) at 24 months.
Aims. Highly cross-linked polyethylene (HXLPE) has greatly improved the durability of total hip arthroplasty (THA) in young patients because of its improved wear characteristics. Few studies have followed this population into the second decade, and therefore the purpose of this investigation was to evaluate the clinical outcome for THA patients 50 years of age and younger at a minimum of 15 years postoperatively. The second purpose was to evaluate the radiological findings secondary to wear or mechanical failure of the implant. Methods. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) aged 50 years and younger (mean 42 years (20 to 50)). There were 87 patients (96 hips) that were followed for a minimum of 15 years (mean 17.3 years (15 to 21)) for analysis. Posterior approach was used with cementless fixation with a median head size of 28 mm. HXLPE was the acetabular bearing for all hips. Radiographs were evaluated for polyethylene wear,
Since 1977 we did implant ceramic on ceramic THR in younger and active population. In 1991 we published (JBJS B N°4) data's in a consecutive group of patients under 50 years of age. What about the same patients for more than 30 years? Eighty-six hips in 75 patients, 41 males 34 females, mean age 43 (18 to 50), mean weight 68 kg (36 to 100), Charnley class: 38 A, 28 (38 hips) B, 9 patients (10 hips) C. Sixty-six primary procedures, 20 revisions (18 failed arthroplasties: 6 THR, 5 resurfacing, four single cup, two hemiarthroplasty, one bipolar), one after acetabular fractures. Four hips previously infected. Eight Patients deceased (8 hips) prosthesis still in place, ten lost to follow-up before 2 years, eight hips in 8 patients were revised before the review, partially followed: from 2 to 20 years: 35, completely followed: 25 hips in 23 patients resuming in: No pain in 20, slight pain in 2, severe disability in 3 not related to the hip, no
Cup-cage constructs are one of several methods commonly used to treat severe acetabular bone loss during contemporary revision total hip arthroplasty. The purpose of this study was to provide a long-term results of the technique with emphasis on implant survivorship, radiographic results, and clinical outcomes for both full and half cup-cage reconstructions. We identified 57 patients treated with a cup-cage reconstruction for major acetabular bone loss between 2002–2012. All patients had Paprosky Type 2B through 3B bone loss, with 60% having an associated pelvic discontinuity. Thirty-one patients received a full cup-cage construct, and 26 a half cup-cage. Mean age at reconstruction was 66 years, 75% were female, and the mean BMI was 27 kg/m. 2. Mean follow-up was 10 years. The 10-year cumulative incidences of any revision were 14% and 12% for the full and half cup-cage construct groups, respectively. Of the 9 revisions, 3 were for dislocation, 2 for aseptic loosening and construct failure (both were pelvic discontinuities), 1 for adverse local tissue reaction, and 1 for infection with persistent pelvic discontinuity. The 10-year cumulative incidences of revision for aseptic loosening were 4.5% and 5% for the full and half cup-cage constructs, respectively. Of the unrevised cases, incomplete and non-progressive zone 3
Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant
Introduction. THA for patient's 50 years and younger is a procedure at high risk for complications and failure because of the high level of activity of this population. Highly cross linked polyethylene (HXLPE) has greatly improved the durability of the implant because of the improved wear characteristics. Few studies have followed this population into the second decade and therefore the purpose of this investigation was to evaluate the clinical outcome for the patients 5o years of age and younger at a minimum of 15 years. The second purpose was to evaluate the radiographic findings secondary to wear or mechanical failure of the implant. Methods. Between October 1999 and December 2005, 105 THAs were performed in 95 patients (53 female, 42 male) age 50 years and younger (mean 42 years; range 20–50). Ten patients (10 hips) were lost to follow-up or deceased. The remaining 95 hips and 85 patients were followed for a minimum of 15 years (mean of 16.8, range 15–20.5) for analysis. HXLPE (Longevity, Zimmer Biomet) was the acetabular bearing for all hips. Radiographs were evaluated for
Aims. Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable radiological findings. The aim of this retrospective study was to evaluate changes of radiological findings up to three years postoperatively, and to assess any potential contributing factors on such radiological change in a Japanese population. Methods. This is a retrospective radiological study conducted in Japan. Radiological assessment was done in accordance with predetermined radiological review protocol. A total of 241 hips were included in the study and 118 hips (49.0%) revealed radiological change from immediately after surgery to one year postoperatively; these 118 hips were eligible for further analyses. Each investigator screened whether either
Aims. The aim of this study was to compare the mid-term patient-reported outcome, bone remodelling, and migration of a short stem (Collum Femoris Preserving; CFP) with a conventional uncemented stem (Corail). Methods. Of 81 patients who were initially enrolled, 71 were available at five years’ follow-up. The outcomes at two years have previously been reported. The primary outcome measure was the clinical result assessed using the Oxford Hip Score (OHS). Secondary outcomes were the migration of the stem, measured using radiostereometric analysis (RSA), change of bone mineral density (BMD) around the stem, the development of
Aims. To establish the survivorship, function, and metal ion levels in an unselected series of metal-on-metal hip resurfacing arthroplasties (HRAs) performed by a non-designer surgeon. Methods. We reviewed 105 consecutive HRAs in 83 patients, performed by a single surgeon, at a mean follow-up of 14.9 years (9.3 to 19.1). The cohort included 45 male and 38 female patients, with a mean age of 49.5 years (SD 12.5). Results. At the time of review 13 patients with 15 hips had died from causes unrelated to the hip operation, and 14 hips had undergone revision surgery, giving an overall survival rate of rate of 86.7% (95% confidence interval (CI) 84.2 to 89.1). The survival rate in men was 97.7% (95% CI 96.3 to 98.9) and in women was 73.4% (95% CI 70.6 to 75.1). The median head size of the failed group was 42 mm (interquartile range (IQR) 42 to 44), and in the surviving group was 50 mm (IQR 46 to 50). In all, 13 of the 14 revised hips had a femoral component measuring ≤ 46 mm. The mean blood levels of cobalt and chromium ions were 26.6 nmol/l (SD 24.5) and 30.6 nmol/l (SD 15.3), respectively. No metal ion levels exceeded the safe limit. The mean Oxford Hip Score was 41.5 (SD 8.9) and Harris Hip Score was 89.9 (14.8). In the surviving group, four patients had
Stem loosening can be associated with a wide spectrum of bone loss and deformity that represent key factors for choosing the most appropriate revision implant. The aim of this study was to evaluate the clinical outcomes and the survivorship of a consecutive series of THA revisions using a taper rectangular cementless stem for primary implants (Alloclassic® Zweymuller®, Zimmer Warsaw US) at medium-term follow-up. We retrospectively evaluated 113 patients (115 revisions) who underwent femoral revision with Zweymuller stem with a preoperative Paprosky I (86) or II (29) defects from January 2011 to December 2020. The mean follow up was 6 years (2–10). The median age at time of surgery was 71(41–93) with 60 males and 53 females. Osteolysis/radiolucency were observed in the following Gruen zones: I (91), II (3), III (2), VII (15), V (3), VI (1). Clinical assessment was performed by means of Harris Hip Score (HHS) and Visual Analogic Scale (VAS), whereas for the radiological analysis we used conventional x-rays of the hips. The statistical analysis was performed using Graphpad Prism v5.0 and data distribution was assessed by Shapiro-Wilk test, and Wilcoxon matched paired test was used to test the differences between preoperative and postoperative score. 9 patients were lost to fu (deceased or not available), 104 (106 hips) were evaluated. The mean HHS and VAS significantly improved at final follow-up, going from 33,84 and 5,78 preoperatively to 66,42 and 2,05 postoperatively, respectively. 28 patients (25%) showed unprogressive
The Morscher-Spotorno (MS-30) femoral stem is a stainless-steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement. We report the results at ten years of a consecutive series of 124 total hip replacements in 121 patients with the matt-surfaced MS-30 stem and an alumina ceramic head of 28-mm diameter. All the stems were fixed with Palacos bone cement with gentamicin using a modern cementing technique. They were combined with an uncemented, press-fit cup. The mean period of observation was 10.2 years (8.3 to 12.1) and no patient was lost to follow-up. Twenty-seven patients (22%) died with the implant in situ. Nine could only be interviewed by telephone. We included 85 patients with 88 hips in the clinical and radiological follow-up examinations. None of the stems or cups had been revised. The Harris hip score was excellent or good in 97% (85 hips) and moderate in 3% (three hips). Radiologically, six hips (6.8%) had osteolysis adjacent to the stem, mostly in Gruen zone 7. Twenty (22.7%) showed one or more
Introduction. Primary fixation in uncemented Total Hip Replacement (THR) is achieved by implanting an appropriately sized stem. Last year, in our pilot study, we classified undersizing & reported the incidence of subsidence &
Introduction. Patients under the age of 50 who undergo a total hip arthroplasty (THA) are at high risk for wear-related complications due to their higher activity level. Previous studies have shown that highly crosslinked polyethylene (HXLPE) is more durable with no evidence of loosening compared to conventional polyethylene due to its improved wear characteristics. Unfortunately, there are few studies with long term follow-up of HXLPE in this patient population. The purpose of this study was to evaluate two questions related to this population of patients undergoing THA. First, what were the clinical outcomes for HXLPE in patients 50 years or younger at an average follow-up of 15 years? Second, was osteolysis observed in any of these hips?. Methods. Between November 1999 and April 2005, 105 THAs were performed for 90 patients 50 years of age or younger (mean, 42 years; range, 20–50 years). The mean body mass index (BMI) was 30 kg/m2 (range, 17–51 kg/m2). The mean follow-up was 15.25 years (range, 12–19 years). Eight patients (two bilateral) were lost to follow-up, which left 82 patients with 95 hips for analysis. HXLPE was the acetabular bearing for all hips. Harris Hip Scores were collected from all patients. Radiographs were obtained on all patients to evaluate for wear and osteolysis. Results. Clinical outcomes show excellent results in 81 hips, good results in ten, fair results in three, and a poor result in one hip using the Harris Hip Score. There have been no revisions, infections, or dislocations in this cohort of patients. Fourteen hips developed
Reconstruction of massive acetabular bone defects in primary and revision THA is challenging for reconstructive joint surgeons. The use of porous metal augments is one of the options. The advantages of porous metal augments are easy to use, modularity and lack of resorption. We investigated the radiological results of porous metal augments used for massive acetabular bone defects in primary and revision THA. Forty-one hips in forty patients had porous metal augments between 2011 and 2016. Thirty of the procedures were revision arthroplasties and 11 were primary procedures (Crowe type III in 5 hips, Crowe type IV in 3, septic hip sequalae in 2 and RA in one). Four of the revisions were second-stage reimplantation after infection. The Paprosky classification for revision was 2B in 4 hips, 2C in one, 3A in 3 and 3B in 22. Regenerex augments were used in 39 hips and trabecular metal augments were used in 2. Thirty-six cups were cemented and 5 cups were uncemented. Mean follow-up was 37.6 months (range, 1–82). Radiographic findings of osteointegration between host bone and the porous metal augments were assessed. The presence or absence of