Carpal tunnel release surgery is a commonly performed procedure for alleviating symptoms of median nerve compression and restoring hand function. With pressure on theatre time these procedures are now commonly performed in a step-down out-patient facility under local anaesthetic. The choice of suture for skin closure in this procedure can impact the quality of wound healing, patient outcomes and the follow-up required however the question of the best type of suture remains unanswered. The purpose of this study was to compare the outcomes of absorbable and non-absorbable sutures using a randomised control trial design. Eighty patients diagnosed with bilateral carpal tunnel syndrome were enrolled and underwent outpatient carpal tunnel release surgery under local anaesthetic in a staged fashion. Random number generation was used to assign each hand to receive interrupted nylon or Vicryl Rapide sutures. Pre-operative data collection included patient demographics, ASA, inflammatory conditions, smoking status as well as a Boston Carpal Tunnel Questionnaire (BCTQ) for each hand. Patients were followed up at 2 and 6 weeks after each operation and the BCTQ was repeated along with the Patient and Observer Scar Assessment Scale and the VAS score for wound discomfort. This study has approval from the DHB ethics committee, Local Iwi, HDC and ANZ Clinical Trials:ACTRN12623000100695.Objective
Methods
Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes. Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model. A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group. This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups.
Our primary objective was to compare healing rates in patients undergoing arthroscopic rotator cuff repair for degenerative tears, with and without bone channeling. Our secondary objectives were to compare disease-specific quality of life and patient reported outcomes as measured by the Western Ontario Rotator Cuff Index (WORC), American Shoulder and Elbow Surgeons (ASES) score and Constant score between groups. Patients undergoing arthroscopic rotator cuff repair at three sites were randomized to receive either bone channeling augmentation or standard repair. Healing rates were determined by ultrasound at 6 and 24 months post operatively. WORC, ASES, and Constant scores were compared between groups at baseline and at 3, 6, 12 and 24 months post operatively. One hundred sixty-eight patients were recruited and randomized between 2013 to 2018. Statistically significant improvements occurred in both groups from pre-operative to all time points in all clinical outcome scores (p < 0 .0001). Intention to treat analysis revealed no statistical differences in healing rates between the two interventions at 24 months post-operative. No differences were observed in WORC, ASES or Constant scores at any time-point. This trial did not demonstrate superiority of intra-operative bone channeling in rotator cuff repair surgery at 24 months post-operative. Healing rates and patient-reported function and quality of life measures were similar between groups.
Fractures of the humeral diaphysis occur in a bimodal distribution and represent 3-5% of all fractures. Presently, the standard treatment of isolated humeral diaphyseal fractures is nonoperative care using splints, braces, and slings. Recent data has questioned the effectiveness of this strategy in ensuring fracture healing and optimal patient function. The primary objective of this randomized controlled trial (RCT) was to assess whether operative treatment of humeral shaft fractures with a plate and screw construct provides a better functional outcome than nonoperative treatment. Secondary objectives compared union rates and both clinical and patient-reported outcomes. Eligible patients with an isolated, closed humeral diaphyseal fracture were randomized to either nonoperative care (initial sugar-tong splint, followed by functional coaptation brace) or open reduction and internal fixation (ORIF; plate and screw construct). The primary outcome measure was the Disability Shoulder, Arm, Hand (DASH) score assessed at 2-, 6-, 16-, 24-, and 52-weeks. Secondary outcomes included the Short Musculoskeletal Functional Assessment (SMFA), the Constant Shoulder Score, range of motion (ROM), and radiographic parameters. Independent samples t-tests and Chi-squared analyses were used to compare treatment groups. The DASH, SMFA, and Constant Score were modelled over time using a multiple variable mixed effects model. A total of 180 patients were randomized, with 168 included in the final analysis. There were 84 patients treated nonoperatively and 84 treated with ORIF. There was no significant difference between the two treatment groups for age (mean = 45.4 years, SD 16.5 for nonoperative group and 41.7, SD 17.2 years for ORIF group; p=0.16), sex (38.1% female in nonoperative group and 39.3% female in ORIF group; p=0.87), body mass index (mean = 27.8, SD 8.7 for nonoperative group and 27.2, SD 6.2 for ORIF group; p=0.64), or smoking status (p=0.74). There was a significant improvement in the DASH scores at 6 weeks in the ORIF group compared to the nonoperative group (mean=33.8, SD 21.2 in the ORIF group vs. mean=56.5, SD=21.1 in the nonoperative group; p < 0 .0001). At 4 months, the DASH scores were also significantly better in the ORIF group (mean=21.6, SD=19.7 in the ORIF group vs. mean=31.6, SD=24.6 in the nonoperative group; p=0.009. However, there was no difference in DASH scores at 12-month follow-up between the groups (mean=8.8,SD=10.9 vs. mean=11.0, SD=16.9 in the nonoperative group; p=0.39). Males had improved DASH scores at all timepoints compared with females. There was significantly quicker time to union (p=0.016) and improved position (p < 0 .001) in the ORIF group. There were 13 (15.5%) nonunions in the nonoperative group and four (4.7%) combined superficial and deep infections in the ORIF group. There were seven radial nerve palsies in the nonoperative group and five (a single iatrogenic) radial nerve palsies in the ORIF group. This large RCT comparing operative and nonoperative treatment of humeral diaphyseal fractures found significantly improved functional outcome scores in patients treated surgically at 6 weeks and 4 months. However, the early functional improvement did not persist at the 12-month follow-up. There was a 15.5% nonunion rate, which required surgical intervention, in the nonoperative group and a similar radial nerve palsy rate between groups.
The aim of this study was to investigate surgeons’ reported change of treatment preference in response to the results and conclusion from a randomized controlled trial (RCT) and to study patterns of change between subspecialties and nationalities. Two questionnaires were developed through the Delphi process for this cross-sectional survey of surgical preference. The first questionnaire was sent out before the publication of a RCT and the second questionnaire was sent out after publication. The RCT investigated repair or non-repair of the pronator quadratus (PQ) muscle during volar locked plating of distal radial fractures (DRFs). Overall, 380 orthopaedic surgeons were invited to participate in the first questionnaire, of whom 115 replied. One hundred surgeons were invited to participate in the second questionnaire. The primary outcome was the proportion of surgeons for whom a treatment change was warranted, who then reported a change of treatment preference following the RCT. Secondary outcomes included the reasons for repair or non-repair, reasons for and against following the RCT results, and difference of preferred treatment of the PQ muscle between surgeons of different nationalities, qualifications, years of training, and number of procedures performed per year. Of the 100 surgeons invited for the second questionnaire, 74 replied. For the primary outcome, 6 of 32 surgeons (19%), who usually repaired the PQ muscle and therefore a change of treatment preference was warranted, reported a change of treatment preference based on the RCT publication. Of the secondary outcomes, restoring anatomy was the most common response for repairing the PQ muscle. The majority of the orthopaedic surgeons, where a change of treatment preference was warranted based on the results and conclusion of a RCT, did not report willingness to change their treatment preference.
This study used model-based radiostereometric analysis (MBRSA) to compare migration of a recently introduced cementless hip stem to an established hip stem of similar design. Novel design features of the newer hip stem included a greater thickness of hydroxyapatite coating and a blended compaction extraction femoral broach. Fifty-seven patients requiring primary total hip arthroplasty (THA) were enrolled at a single centre. Patients were randomized to receive either an Avenir collarless stem and Trilogy IT cup (ZimmerBiomet) or a Corail collarless stem and Pinnacle cup (DePuy Synthes) via a posterior or lateral approach. Both stems are broach-only femoral bone preparation. RSA beads (Halifax Biomedical) were inserted into the proximal femur during surgery. Patients underwent supine RSA imaging a 6 weeks (baseline), 6, 12, and 24 months following surgery. The primary study outcome was total subsidence of the hip stem from baseline to 24 months as well as progression of subsidence between 12 and 24 months. These values were compared against published migration thresholds for well-performing hip stems (0.5mm). The detection limit, or precision, of MBRSA was calculated based on duplicate examinations taken at baseline. Patient reported outcome measures were collected throughout the study and included the Oxford-12 Hip Score (OHS), EuroQoL EQ-5D-5L, Hip Osteoarthritis Score (HOOS) as well as visual analogue scales (VAS) for thigh pain and satisfaction. Analysis comprised of paired and unpaired t-tests with significance set at p≤0.05. Forty-eight patients (30 males) were included for analysis; 7 patients received a non-study hip stem intra-operatively, 1 patient suffered a traumatic dislocation within three weeks of surgery, and 1 patient died within 12 months post-surgery. RSA data was obtained for 45 patients as three patients did not receive RSA beads intra-operatively. Our patient cohort had a mean age of 65.9 years (±;7.2) at the time of surgery and body mass index of 30.5 kg/m2 (±;5.2). No statistical difference in total stem migration was found between the Avenir and Corail stems at 12 months (p=0.045, 95%CI: −0.046 to 0.088) and 24 months (p=0.936, 95% CI: −0.098 to 0.090). Progression of subsidence from 12-24 months was 0.011mm and 0.034mm for the Avenir and Corail groups which were not statistically different (p=0.163, 95%CI: −0.100 to 0.008) between groups and significantly less than the 0.5mm threshold (pNo statistically significant differences existed between study groups for any pre-operative function scores (p>0.05). All patients showed significant functional improvement from pre- to post-surgery and no outcome measures were different between study groups with exception of EQ-5D-5L health visual analogue scale at 12 months which showed marginally superior (p=0.036) scores in the Avenir group. This study was not powered to detect differences in clinical outcomes. This study has demonstrated no statistical difference in subsidence or patient-reported outcomes between the Corail hip stem and the more recently introduced Avenir hip stem. This result is predictable as both stems are of a triple-tapered design, are coated with hydroxyapatite, and utilize a broach-only bone preparation technique. Both stem designs demonstrate migration below 0.5mm suggesting both are low-risk for aseptic loosening in the long-term.
In 10% of the presumed aseptic hip or knee revisions, a low-grade infection is unexpectedly diagnosed based on the tissue samples taken during revision. Extended antimicrobial prophylaxis can possibly reduce the failure rate in cases of unexpected PJI, because the prophylaxis can be considered as early empiric treatment. In this randomized controlled study we analysed whether extended antimicrobial prophylaxis compared to a single dose is beneficial to improve the outcome of treatment in unexpected PJI in revision arthroplasty. This study was nested in a randomized clinical trial comparing single-dose cefazolin with prolonged prophylaxis (15 doses of cefazolin over 5 days) for revision arthroplasty of the hip or knee. For this analysis, patients were included if an unsuspected PJI (defined as ≥2 positive intraoperative tissue samples with the same microorganism) was diagnosed. PJI treatment consisted of 12 weeks of a rifampicin-based regimen in Staphylococcal PJI, without removal of the prosthesis. We examined Infection characteristics and success of treatment after one year, defined as the absence of signs or treatment for PJI during follow-up.Aim
Method
Orthopaedic surgeons prescribe more opioids than any other surgical speciality. Opioids remain the analgesic of choice following arthroscopic knee and shoulder surgery. There is growing evidence that opioid-sparing protocols may reduce postoperative opioid consumption while adequately addressing patients’ pain. However, there are a lack of prospective, comparative trials evaluating their effectiveness. The objective of the current randomized controlled trial (RCT) was to evaluate the efficacy of a multi-modal, opioid-sparing approach to postoperative pain management in patients undergoing arthroscopic shoulder and knee surgery. The NO PAin trial is a pragmatic, definitive RCT (NCT04566250) enrolling 200 adult patients undergoing outpatient shoulder or knee arthroscopy. Patients are randomly assigned in a 1:1 ratio to an opioid-sparing group or standard of care. The opioid-sparing group receives a three-pronged prescription package consisting of 1) a non-opioid prescription: naproxen, acetaminophen and pantoprazole, 2) a limited opioid “rescue prescription” of hydromorphone, and 3) a patient education infographic. The control group is the current standard of care as per the treating surgeon, which consists of an opioid analgesic. The primary outcome of interest is oral morphine equivalent (OME) consumption up to 6 weeks postoperatively. The secondary outcomes are postoperative pain scores, patient satisfaction, quantity of OMEs prescribed and number of opioid refills. Patients are followed at both 2 and 6 weeks postoperatively. Data analysts and outcome assessors are blinded to the treatment groups. As of December 1, 2021 we have enrolled 166 patients, reaching 83% of target enrolment. Based on the current recruitment rate, we anticipate that enrolment will be completed by the end of January 2022 with final follow-up and study close out completed by March of 2022. The final results will be released at the Canadian Orthopaedic Association Meeting in June 2022 and be presented as follows. The mean difference in OME consumption was XX (95%CI: YY-YY, p=X). The mean difference in OMEs prescribed was XX (95%CI: YY-YY, p=X). The mean difference in Visual Analogue Pain Scores (VAS) and patient satisfaction are XX (95%CI: YY-YY, p=X). The absolute difference in opioid refills was XX (95%CI: YY-YY, p=X). The results of the current study will demonstrate whether an opioid sparing approach to postoperative outpatient pain management is effective at reducing opioid consumption while adequately addressing postoperative pain in patients undergoing outpatient shoulder and knee arthroscopy. This study is novel in the field of arthroscopic surgery, and its results will help to guide appropriate postoperative analgesic management following these widely performed procedures.
There is no consensus regarding the optimum frequency of ultrasound for monitoring the response to Pavlik harness (PH) treatment in developmental dysplasia of hip (DDH). The purpose of our study was to determine if a limited-frequency hip ultrasound (USS) assessment in children undergoing PH treatment for DDH had an adverse effect on treatment outcomes when compared to traditional comprehensive ultrasound monitoring. This study was a single-center non-inferiority randomized controlled trial. Children aged less than six months of age with dislocated, dislocatable and stable dysplastic hips undergoing a standardized treatment program with a PH were randomized, once stability had been achieved, to our current standard USS monitoring protocol (every clinic visit) or to a limited-frequency ultrasound protocol (USS only until hip stability and then end of treatment). Groups were compared based on alpha angle at the end of treatment, acetabular indices (AI) and IHDI grade on follow up radiographs at one-year post harness and complication rates. The premise was that if there were no differences in these outcomes, either protocol could be deemed safe and effective. One hundred patients were recruited to the study; after exclusions, 42 patients completed the standard protocol (SP) and 36 completed the limited protocol (LP). There was no significant difference between the mean age between both groups at follow up x-ray (SP: 17.8 months; LP: 16.6 months; p=0.26). There was no difference between the groups in mean alpha angle at the end of treatment (SP: 69°; LP: 68.1°: p=0.25). There was no significant difference in the mean right AI at follow up (SP: 23.1°; LP: 22.0°; p=0.26), nor on the left (SP:23.3°; LP 22.8°; p=0.59). All hips in both groups were IHDI grade 1 at follow up. The only complication was one femoral nerve palsy in the SP group. In addition, the LP group underwent a 60% reduction in USS use once stable. We found that once dysplastic or dislocated hips were reduced and stable on USS, a limited- frequency ultrasound protocol was not associated with an inferior complication or radiographic outcome profile compared to a standardized PH treatment pathway. Our study supports reducing the frequency of ultrasound assessment during PH treatment of hip dysplasia. Minimizing the need for expensive, time-consuming and in-person health care interventions is critical to reducing health care costs, improving patient experience and assists the move to remote care. Removing the need for USS assessment at every PH check will expand care to centers where USS is not routinely available and will facilitate the establishment of virtual care clinics where clinical examination may be performed remotely.
Patients awaiting resolution of swelling and oedema prior to ankle surgery can represent a significant burden on hospital beds. Our study assessed whether external pneumatic intermittent compression (EPIC) can reduce delays to surgery. Our prospective randomised controlled trial (n= 20) compared outcomes of patients treated with EPIC vs control group managed with ice and elevation. Included were patients aged <18 years with isolated closed ankle fractures admitted for management of swelling prior to surgery. Excluded were open fractures, injuries to contralateral leg, diabetes, absent pulses, peripheral vascular disease, inability to consent, no requirement for admission. Eligible patients were randomised to active or control arms. All patients were managed initially with reduction and back slab application. Patients in active arm fitted with EPIC (Hydroven 3000) device over the back slab. Assessment by treating team determined the time at which patient is assessed ready for surgery. Patients in the treatment arm were assessed as ready for surgery sooner, (123 hrs vs 168hrs, T score = 1.925, P 0.035) and had a shorter time to surgery (167 hrs vs 216 hrs, T score = 1.748, P 0.047) Length of stay was reduced bud did not reach statistical significance. (259 hrs vs 269 hrs, T score 0.229, P 0.41) Our results showed a statistically and clinically significant reduction in time that patients were assessed ready for surgery and time to surgery in the treatment cohort. We conclude that although further data is needed to achieve an adequately powered study and assess the safety profile of the EPIC, incorporation of EPIC into routine clinical practice has the potential for significant cost savings.
Hamstring grafts have been associated with reduced strength, donor site pain and muscle strains following Anterior Cruciate Ligament Reconstruction (ACLR). Traditional graft fixation methods required both semitendinosus and gracilis tendons to achieve a graft of sufficient length and diameter, but newer techniques allow for shorter, broad single tendon grafts. This study seeks to compare the outcomes between Single Tendon (ST) and Dual Tendon (DT) ACLR, given there is no prospective randomised controlled trial (RCT) in the literature comparing outcomes between these options. In this ongoing RCT: (ANZ Clinical Trials Registry ACTRN126200000927921) patients were recruited and randomised into either ST or DT groups. All anaesthetic and surgical techniques were uniform aside from graft technique and tibial fixation. 13 patients were excluded at surgery as their ST graft did not achieve a minimum 8mm diameter. 70 patients (34 ST, 36DT) have been assessed at 6 months, using PROMS including IKDC2000, Lysholm and Modified Cincinnati Knee, visual analog scale for pain frequency (VAS-F) and severity (VAS-S), dedicated donor site morbidity score, KT-1000 assessment, and isokinetic strength. Graft diameters were significantly lesser in the ST group compared to the DT group (8.44mm/9.11mm mean difference [MD],-0.67mm; P<0.001). There was a significant and moderate effect in lower donor site morbidity in the ST group compared to the DT group (effect size [ES], 0.649; P = .01). No differences between groups were observed for knee laxity in the ACLR limb (P=0.362) or any of the patient-reported outcome measures (P>0.05). Between-group differences were observed for hamstrings strength LSI favouring the ST group, though these were small-to-moderate and non-significant (ES, 0.351; P = .147). ST (versus DT) harvest results in significantly less donor site morbidity and this is the first prospective RCT to determine this. There were no differences between ST and DT hamstring ACLR were observed in PROMs, knee laxity and hamstring strength. Younger female patients tend to have inadequate single tendon size to produce a graft of sufficient diameter, and alternative techniques should be considered. Further endpoints include radiological analysis, longer term donor site morbidity, revision rates and return to sport and will continue to be presented in the future.
Digital injuries are among the most common presentations to the emergency department. In order to sufficiently examine and manage these injuries, adequate, prompt, and predictable anaesthesia is essential. In this trial, we aim to primarily compare the degree of pain and anaesthesia onset time between the two-injection dorsal block technique (TD) and the single-injection volar subcutaneous block technique (SV). Further, we describe the temporal and anatomical effects of both techniques for an accurate delineation of the anesthetized regions. A single-centre prospective randomized controlled trial involving patients presenting with isolated wounds to the fingers requiring primary repair under local anaesthesia. Patients were randomized to either the SV or TD blocks. The primary outcome was procedure-related pain (Numerical Rating Scale). Further, we assessed the extent of anaesthesia along with the anaesthesia onset time.Background
Methods
Cryocompression therapy is a non-invasive and non-pharmacological modality used in managing acute post-operative inflammation and pain. A prospective, randomised controlled trial (RCT) was undertaken to evaluate the effectiveness of a post-operative cryocompression protocol using the Game Ready™ (GR) device versus usual care on recovery following total knee arthroplasty (TKA). A single centre RCT was conducted with 70 TKAs (68 patients) randomised to a 2-week intervention period consisting of treatment with GR cryocompression (n=33, 33.3% males) or a usual care protocol of ice with static compression using tubigrip (n=35, 54.3% males). Knee range of movement (ROM) (flexion and extension), a visual analogue pain score (VAS) and limb circumference were documented at day 1, 2 and 14, as well as 6 and 12 weeks post-surgery. ROM was also recorded at day 90, while medication use and length of hospital stay were documented. Patient reported outcome measures (PROMs) including the KOOS and patient satisfaction questionnaire were employed. The GR group demonstrated 2.3° more (p=0.05) knee extension ROM overall, as well as 2. 8° more at day 1 (p=0.048), 3.8° at day 14 (p=0.007) and 5.4° at 3 months (p=0.017). There were no group differences (p>0.05) observed in pain (VAS), flexion ROM, limb circumference, opioid use or other PROMs. Across the full cohort, higher pain levels resulted in increased opioid intake (p=0.002), older patients used significantly less opioids (p<0.001) and males reported significantly less pain (VAS) than females (p=0.048). Using GR following TKA is a safe, non-invasive tool that can be used to aid in the post-operative recovery period. Patients using the GR cryocompression device gained significantly more extension ROM compared to the conventional ice with compression group, despite no other group differences.
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone.
Adequate visual clarity is paramount to performing arthroscopic shoulder surgery safely, efficiently, and effectively. The addition of epinephrine in irrigation fluid, and the intravenous or local administration of tranexamic acid (TXA) have independently been reported to decrease bleeding thereby improving the surgeon's visualization during arthroscopic shoulder procedures. No study has compared the effect of systemic administered TXA, epinephrine added in the irrigation fluid or the combination of both TXA and epinephrine on visual clarity during shoulder arthroscopy with a placebo group. The purpose of this study is to determine if intravenous TXA is a safe alternative to epinephrine delivered by a pressure-controlled pump in improving arthroscopic shoulder visualization during arthroscopic procedures and whether using both TXA and epinephrine together has an additive effect in improving visualization. The design of the study was a double-blinded, randomized controlled trial with four 1:1:1:1 parallel groups conducted at one center. Patients aged ≥18 years undergoing arthroscopic shoulder procedures including rotator cuff repair, arthroscopic biceps tenotomy/tenodesis, distal clavicle excision, subacromial decompression and labral repair by five fellowship-trained upper extremity surgeons were randomized into one of four arms: Pressure pump-controlled regular saline irrigation fluid (control), epinephrine (1ml of 1:1000) mixed in irrigation fluid (EPI), 1g intravenous TXA (TXA), and epinephrine and TXA (EPI/TXA). Visualization was rated on a 4-point Likert scale every 15 minutes with 0 indicating ‘poor’ quality and 3 indicating ‘excellent’ quality. The primary outcome measure was the unweighted mean of these ratings. Secondary outcomes included mean arterial blood pressure (MAP), surgery duration, surgery complexity, and adverse events within the first postoperative week. One hundred and twenty-eight participants with a mean age (± SD) of 56 (± 11) years were randomized. Mean visualization quality for the control, TXA, EPI, and EPI/TXA groups were 2.1 (±0.40), 2.1 (±0.52), 2.6 (±0.37), 2.6 (±0.35), respectively. In a regression model with visual quality as the dependent variable, the presence/absence of EPI was the most significant predictor of visualization quality (R=0.525; p < 0 .001). TXA presence/absence had no effect, and there was no interaction between TXA and EPI. The addition of MAP and surgery duration strengthened the model (R=0.529; p < 0 .001). Increased MAP and surgery duration were both associated with decreased visualization quality. When surgery duration was controlled, surgery complexity was not a significant predictor of visualization quality. No adverse events were recorded in any of the groups. Intravenous administration of TXA is not an effective alternative to epinephrine in the irrigation fluid to improve visualization during routine arthroscopic shoulder surgeries although its application is safe. There is no additional improvement in visualization when TXA is used in combination with epinephrine beyond the effect of epinephrine alone.
A tourniquet is usually used during ankle arthroscopy to allow for improved visibility and reduced operation time. However, clinical studies on knee arthroscopy have not demonstrated this to be true. In addition, Zengerink and van Dijk emphasized a limited tourniquet time in ankle arthroscopy as a possible factor to lower the complication rate even more. The purpose of this prospective randomized controlled trial was to examine the effect of tourniquet use on arthroscopic visualization, operative time, postoperative intra-articular bleeding, postoperative pain scores and outcome of anterior ankle arthroscopy. A consecutive series of 50 patients who were scheduled for anterior ankle arthroscopy were randomized to have the surgery done either without the tourniquet inflated (25 patients) or with the tourniquet inflated (25 patients). The patients were evaluated by the course of the surgery, postoperative intra-articular bleeding, pain during the early postoperative period and by using the subjective and objective functional scores to evaluate the condition of the ankle before and 3 and 6 months after the surgery. The statistical analysis was performed with the normality of distribution tested by both Kolmogorov-Smirnov and Shapiro-Wilk tests. Appropriate parametric or non-parametric methods were then used to test statistical hypotheses, while the statistical significance (alpha, Type I error) was set at .05. Fourty-nine patients were present at the final follow-up, 6 months after the surgery. The results between the groups were comparable regarding the duration of the operative procedure, consumption of sterile saline, visualisation and functional scores. Notable difference between the groups in favour of the non-tourniquet group was present regarding postoperative bleeding, but was not statistically significant. Statistically significant difference in favour of the non-tourniquet group was found regarding postoperative pain during several days in the early postoperative period. Our study has shown that anterior ankle arthroscopy may be performed adequately without the use of a tourniquet and that it has the same operative course as in cases in which the tourniquet is used and functional outcomes which are not worse than in cases in which the tourniquet is used.
Given the low prevalence of sarcoma, international cooperation is necessary to recruit sufficient numbers of patients for surgical trials. The PARITY (Prophylactic Antibiotic Regimens in Tumour Surgery) trial is the first international multicentre trial in orthopedic oncology and successfully achieved target enrollment of 600 patients across 12 countries. It is important to reflect upon the challenges encountered and experiences gained to inform future trials. The objective of this study is to describe recruitment patterns and examine the differences in enrollment across different PARITY sites and identify variables associated with varying levels of recruitment. Data from this study was obtained from the PARITY trial Methods Centre and correspondence data. We performed descriptive statistics to demonstrate the recruitment patterns over time. We compared recruitment, time to set up, and time to enroll the first patient between North American and international sites, and sites that had dedicated research personnel. Two-tailed non-paired t-tests were performed to compare average monthly recruitment rates between groups with significance being set at alpha=0.05. A total of 600 patients from 48 clinical sites and 12 countries were recruited from January 2013 through to October 2019. Average monthly enrollment increased every year of the study. There were 36 North American and 12 international sites. North American sites were able to set up significantly faster than international sites (19.3 vs. 28.3 months p=0.037). However, international sites had a significantly higher recruitment rate per month once active (0.2/month vs. 0.62/month, p=0.018). Of active sites, 40 (83%) had research support personnel and 8 (17%) sites did not. Sites with research personnel were able to reach ‘enrolment ready’ status significantly faster than sites without research support (19.6 vs. 30.7 months, p=0.032). However, there was no significant difference in recruitment rate per month once the sites began enrolling (0.28/month vs. 0.2/month, p=0.63). Trial sites that took longer than 1 year to recruit their first patient had 3x lower average recruitment rate compared to sites that were able to recruit their first patient within a year of being enrolment ready. The PARITY trial is the first multicentre RCT in orthopaedic oncology. The PARITY investigators were able to increase the recruitment levels throughout the trial and generally avoid trial fatigue. This was a North American based trial which may explain the longer start up times internationally given the different regulatory bodies associated with drug-related trials. However, international sites should be considered critical as they were able to recruit significantly more patients per month once active. The absence of research support personnel should not preclude a site from inclusion. These sites took longer to setup but had no difference in monthly recruitment once active. This study will create a framework for identifying and targeting high yield sites for future randomized control trials within orthopaedic oncology to maximum recruitment and resource allocation. Data quality is another consideration that will be addressed in future analyses of the PARITY trial.
Ankle arthrodesis and replacement are the widely accepted options in managing end-stage ankle arthritis. Ankle replacement as an alternate treatment option for ankle arthritis is relatively new and this is in large part to the successes observed with hip and knee arthroplasty for arthritis. Relative benefits of ankle replacement and arthrodesis remains a contentious topic. We conducted a multicenter pilot randomized controlled trial, first of its kind, comparing the clinical outcomes of ankle arthrodesis and ankle replacement in managing ankle arthritis. We hypothesized that clinical outcomes would be similar for both. Patients recruited for this study were part of Canadian Orthopaedic Foot and Ankle Society (COFAS) Database. Canadian orthopaedic surgeons with fellowship training in foot and ankle surgery or extensive experience in the surgical treatment of end stage ankle arthritis determined whether the patient met the criteria for randomization, skeletal maturity, symptomatic ankle arthritis no longer amenable to non-operative management, and ability to give informed consent. Data was collected on patient demographics, follow-up time period, complication rates, and Ankle Osteoarthritis Scale (AOS) and Short Form-36 (SF-36) scores. Our analysis of clinical outcomes was divided into two parts: (1) comparison of pre and postoperative data for each cohort separately, and (2) comparison of outcome scores, and revision rates between both cohorts. We employed the Student's t-test and calculated effect sizes in assessing improvements in AOS and SF-36 scores from baseline to latest follow-up within and between the two groups. We also examined postoperative complication and reoperation rates in the study population using the standardized coding system for reoperations following ankle replacement and arthrodesis. Thirty-nine ankles were enrolled in the study with a mean follow-up of 5.1 ± 2.8 years. Ankle osteoarthritis scale scores improved significantly from baseline and last follow-up in both groups. The average baseline AOS total score for ankle replacement improved from 59.4 ±15.9 to 38 ±20 at last follow-up (p-value 19.7 to 31.8 ±16.5 at last follow-up (p-value 25.4 compared to ankle replacement's 20.3 ±23. Two major complications (10.5%) were observed in the ankle replacement cohort while the ankle arthrodesis cohort saw four major complications (20%). Clinical outcomes of ankle replacement and arthrodesis were comparable. The ankle arthrodesis cohort held a slight advantage over ankle replacement in improvement of AOS scores, though not statistically significant. Rates of major complications and reoperations were higher with ankle arthrodesis.
The efficacy of Virtual Reality (VR) as a teaching augment for arthroplasty has not been well examined for unfamiliar multistep procedures such as unicompartmental knee arthroplasty (UKA). This study sought to determine if VR improves surgical competence over traditional procedural preparation when performing a UKA. 22 Orthopaedic trainees were randomized to training sessions: 1) “VR group” with access to an immersive VR learning module that had been designed in conjunction with the manufacturer or 2) “Guide group” with access to manufacture's technique guide and surgical video. Both groups then performed a full UKA on SawBones models. Surgical competence was assessed via Objective Structures Assessment of Technical Skills (OSATS) validated rating system (max 25 points).Introduction
Methods
Glenoid baseplate positioning for reverse total shoulder replacements (rTSR) is key for stability and longevity. 3D planning and image-derived instrumentation (IDI) are techniques for improving implant placement accuracy. This is a single-blinded randomised controlled trial comparing 3D planning with IDI jigs versus 3D planning with conventional instrumentation. Eligible patients were enrolled and had 3D pre-operative planning. They were randomised to either IDI or conventional instrumentation; then underwent their rTSR. 6 weeks post operatively, a CT scan was performed and blinded assessors measured the accuracy of glenoid baseplate position relative to the pre-operative plan. 47 patients were included: 24 with IDI and 23 with conventional instrumentation. The IDI group were more likely to have a guidewire placement within 2mm of the preoperative plan in the superior/inferior plane when compared to the conventional group (p=0.01). The IDI group had a smaller degree of error when the native glenoid retroversion was >10° (p=0.047) when compared to the conventional group. All other parameters (inclination, anterior/posterior plane, glenoids with retroversion <10°) showed no significant difference between the two groups. Both IDI and conventional methods for rTSA placement are very accurate. However, IDI is more accurate for complex glenoid morphology and placement in the superior-inferior plane. Clinically, these two parameters are important and may prevent long term complications of scapular notching or glenoid baseplate loosening. Image-derived instrumentation (IDI) is significantly more accurate in glenoid component placement in the superior/inferior plane compared to conventional instrumentation when using 3D pre-operative planning. Additionally, in complex glenoid morphologies where the native retroversion is >10°, IDI has improved accuracy in glenoid placement compared to conventional instrumentation. IDI is an accurate method for glenoid guidewire and component placement in rTSA.