Advertisement for orthosearch.org.uk
Results 1 - 20 of 287
Results per page:
Bone & Joint Research
Vol. 11, Issue 1 | Pages 32 - 39
27 Jan 2022
Trousdale WH Limberg AK Reina N Salib CG Thaler R Dudakovic A Berry DJ Morrey ME Sanchez-Sotelo J van Wijnen A Abdel MP

Aims. Outcomes of current operative treatments for arthrofibrosis after total knee arthroplasty (TKA) are not consistently positive or predictable. Pharmacological in vivo studies have focused mostly on prevention of arthrofibrosis. This study used a rabbit model to evaluate intra-articular (IA) effects of celecoxib in treating contracted knees alone, or in combination with capsular release. Methods. A total of 24 rabbits underwent contracture-forming surgery with knee immobilization followed by remobilization surgery at eight weeks. At remobilization, one cohort underwent capsular release (n = 12), while the other cohort did not (n = 12). Both groups were divided into two subcohorts (n = 6 each) – one receiving IA injections of celecoxib, and the other receiving injections of vehicle solution (injections every day for two weeks after remobilization). Passive extension angle (PEA) was assessed in live rabbits at 10, 16, and 24 weeks, and disarticulated limbs were analyzed for capsular stiffness at 24 weeks. Results. IA celecoxib resulted in greater mean PEA at ten weeks (69.6° (SD 4.6) vs 45.2° (SD 9.6), p = 0.004), 16 weeks (109.8° (SD 24.2) vs 60.9° (SD10.9), p = 0.004), and 24 weeks (101.0° (SD 8.0) vs 66.3° (SD 5.8), p = 0.004). Capsular stiffness was significantly reduced with IA celecoxib (2.72 Newton per cm (N·cm)/° (SD 1.04), p = 0.008), capsular release (2.41 N·cm/° (SD 0.80), p = 0.008), and capsular release combined with IA celecoxib (3.56 N·cm/° (SD 0.99), p = 0.018) relative to IA vehicle (6.09 N·cm/° (SD 1.64)). Conclusion. IA injections of a celecoxib led to significant improvements in passive extension angles, with reduced capsular stiffness, when administered to rabbit knees with established experimental contracture. Celecoxib was superior to surgical release, and the combination of celecoxib and a surgical release did not provide any additional value. Cite this article: Bone Joint Res 2022;11(1):32–39


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 14 - 14
7 Aug 2023
Langton D Bhalekar R Wells S Nargol M Haston S Natu S Nargol A
Full Access

Abstract. Introduction. Several studies have reported significant cobalt(Co) and chromium(Cr) elevations in the blood of patients with total-knee-replacements (TKRs), and histological signs of metal sensitivity have been reported in up to 44% of patients undergoing revision of their TKRs. We carried out this investigation to determine the source and quantity of metal release in TKRs. Methodology. We identified all TKRs with polished CoCr trays (N=59) [Vanguard=29, Attune=4 and PFC=26]. These were analysed using peer-reviewed [coordinate-measuring-machine (CMM)] methodology to measure the volumetric wear of the polyethylene (PE) bearing surfaces and trays. The trays were analysed using 2D-profilometry (surface roughness-Ra) and 4D-microscopy. Histological and blood metal ion concentration analyses were performed. Results. The median(IQR) PE wear rate was 10(6to20) mm3/year. Microscopic analysis identified pitting on superior surface of 36(49%) trays. Ra [median (IQR)] of superior surface of pitted trays [0.076 (0.060–0.084) µm] showed a statistically significant increase (p<0.001) compared with unpitted trays [0.057(0.049–0.066) µm]. 4D-microscopy and CMM analysis estimated wear volumes of up to 2mm3 secondary to pitting. The median (range) Co and Cr concentrations were 2.5µg/l (0.2–69.4) and 1.7µg/l (0.5–12.5) respectively in 40 patients. Of the tissue samples examined in 30 patients,6 had at-least “mild”-ALVAL infiltrate. All corresponding “ALVAL” explants were found to be pitted and/or show evidence of loosening of the tray. Conclusion. This study provides further evidence that CoCr release in TKR appears to be an under-recognised cause of adverse clinical outcomes. Gross metal ion elevations occurred in association with micromotion/loosening of the tray


Bone & Joint Research
Vol. 6, Issue 9 | Pages 535 - 541
1 Sep 2017
Zan P Mol MO Yao JJ Fan L Yang D Liu K Li G

Objectives. The length of the tourniquet time during total knee arthroplasty (TKA) is related to the incidence of post-operative deep vein thrombosis (DVT). Our aim in this study was to investigate the effect of the early release of the tourniquet on the incidence of DVT in patients undergoing TKA. Methods. A total of 200 patients who underwent TKA between November 2015 and November 2016 were prospectively enrolled. The tourniquet was inflated before surgery and released immediately after the introduction of the components (early release group). This group was compared with a retrospective cohort of 200 primary TKAs, in which the tourniquet was released after the dressings had been applied (late release group). The presence of a DVT was detected using bilateral lower limb ultrasonography. Peri-operative clinical and follow-up data were collected for analysis. Results. The incidence of DVT in the early release group (9 of 196, 4.6%) was significantly lower compared with the late release group (24 of 200, 12%; odds ratio (OR) 0.35, 95% confidence interval (CI) 0.16 to 0.78, p = 0.008). The incidence of proximal DVT in the early release group (1 of 196 (0.5%)) was significantly lower than in the late release group (8 of 196, 4%; OR 0.12, 95% CI 0.02 to 0.99, p = 0.020). Although the mean intra-operative blood loss was higher in the early release group, the mean post-operative drainage, total blood loss, transfusion requirements and complications were not significantly different in the two groups. Conclusion. In patients who undergo TKA, releasing the tourniquet early is associated with a decreased incidence of DVT, without increasing the rate of complications. Cite this article: Bone Joint Res 2017;6:535–541


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 9 | Pages 1178 - 1182
1 Sep 2009
Hakki S Coleman S Saleh K Bilotta VJ Hakki A

The requirement for release of collateral ligaments to achieve a stable, balanced total knee replacement has been reported to arise in about 50% to 100% of procedures. This wide range reflects a lack of standardised quantitative indicators to determine the necessity for a release. Using recent advances in computerised navigation, we describe two navigational predictors which provide quantitative measures that can be used to identify the need for release. The first was the ability to restore the mechanical axis before any bone resection was performed and the second was the discrepancy in the measured medial and lateral joint spaces after the tibial osteotomy, but before any femoral resection. These predictors showed a significant association with the need for collateral ligament release (p < 0.001). The first predictor using the knee stress test in extension showed a sensitivity of 100% and a specificity of 98% and the second, the difference between medial and lateral gaps in millimetres, a sensitivity of 83% and a specificity of 95%. The use of the two navigational predictors meant that only ten of the 93 patients required collateral ligament release to achieve a stable, neutral knee


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 9 | Pages 1186 - 1192
1 Sep 2008
Lyu S

The outcome of arthroscopic medial release of 255 knees in 173 patients for varying grades of osteoarthritis involving the medial compartment is reported. All operations were performed by a single surgeon between January 2001 and May 2003. The Knee Society score for pain and the patient’s subjective satisfaction were used for the outcome evaluation. Overall, satisfactory outcome was reported for 197 knees (77.3%) and the mean Knee Society score for pain improved from 17.6 (95% confidence interval, 16.7 to 18.5), pre-operatively to 39.4 (95% confidence interval, 37.9 to 41.1) (p < 0.001). There were minor manageable complications of persistent effusion in 16 knees and prolonged wound discomfort in 11. In total, 15 of the 21 knees with poor results were converted to total knee replacements and two other patients (three knees) were offered this option after a mean period of 16 months. Based on these observations arthroscopic medial release is an effective treatment for osteoarthritis of the medial compartment of the knee joint and can be expected to reduce the pain in the majority of patients for at least four years post-operatively


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 60 - 60
1 Jul 2012
Colaço H Davidson J Pekicten B Ahmed S Skyrme A Armitage A Rajaratnam S
Full Access

Purpose. This study investigates the effect of early tourniquet release on range of flexion following total knee replacement, and the influence of anticoagulation with Rivaroxaban and Clexane (Enoxaparin). Method. 78 patients were included in the study, who underwent unilateral primary total knee replacement (TKR) in our department under the care of two specialist knee surgeons over a 12 month period. 27 patients underwent TKR with early release of the tourniquet and haemostasis, prior to closure of quadriceps layer: 22 were anticoagulated with Rivaroxaban (GROUP ER), 15 with the low molecular weight heparin Clexane (GROUP EC). Over the same time period, 41 patients TKR with late release of the tourniquet, following closure and bandaging: 13 were anticoagulated with Rivaroxaban (GROUP LR), 28 with Clexane (GROUP LC). A standardised operative technique was employed, and all patients received an AGC (Biomet) PCL-retaining prostheses. Outcome was assessed with range of flexion at 12 weeks postoperatively. Results. The mean range of flexion at 12 weeks was 106.8° in Group ER, 96.54° in Group LR, 108.33° in Group EC and 101.11° in LC. The mean difference in flexion at 12 weeks between Group EC and LC was 7.2°, and between ER and LR was 10.2°. Conclusion. Our study supports the theory that early tourniquet release and haemostasis has a beneficial effect on the early range of flexion following TKR. This affect appears to be increased when the oral anticoagulant Rivaroxaban is used, when compared with low molecular weight heparin


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 55 - 55
1 Mar 2012
Arbuthnot J Brink R
Full Access

This study investigated the effects of arthroscopic release for the treatment of stiffness in total knee replacement (TKR) to compare the outcomes against the reported outcomes for more invasive procedures such as open release and revision. We prospectively followed all patients undergoing TKR between 1998 and 2008 at the lead author's institution where stiffness other than that for mechanical or infective reasons was treated arthroscopically. Nineteen knees from the author's series of 572 knee replacements and three knees from other units were treated and outcomes were recorded in terms of pre-operative and post-operative Oxford knee scores and range of motion. At arthroscopy each of the 22 knees displayed extensive scarring (particularly in the suprapatella pouch) that was debrided. The mean follow-up was 40 months (range 5 months to 10.5 years). The Oxford knee score improved from 42.6 (±7.5) prior to TKR to 36.3 (±8.5) after TKR and to 29.3 (±9.0) after arthroscopic arthrolysis. The mean maximum flexion declined from 107° prior to TKR to 64°. Arthroscopic arthrolysis improved mean maximum flexion to 105° on table and 93° at most recent follow-up. We recommend this technique as a reasonable option for the treatment of stiffness after knee replacement as it compares well with more invasive surgical options


Bone & Joint Research
Vol. 1, Issue 4 | Pages 64 - 70
1 Apr 2012
Ritter MA Davis KE Meding JB Farris A

Objectives

The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement.

Methods

A total of 3018 anatomic graduated component total knee replacements were examined; 1846 of these retained the PCL, 455 PCLs were partially recessed, and in 717 the PCL was completely excised from the back of the tibia.


The Journal of Bone & Joint Surgery British Volume
Vol. 78-B, Issue 6 | Pages 912 - 916
1 Nov 1996
Marshall PD Broughton NS Menelaus MB Graham HK

We report the results of a prospective study of the surgical release of 45 knee flexion contractures in 28 patients with myelomeningocele. The neurosegmental level was thoracic in ten patients, L1/2 in one, L3/4 in 11, and L5/S1 in six. In walkers the indication for surgery was a fixed flexion contracture impeding walking, and in non-walking patients it was a flexion contracture impeding transfers or sitting balance, or likely to do so with increasing deformity. The mean age at surgery was 6.4 years (3 to 21) and the mean period of follow-up 13 years (4 to 20). The mean knee flexion contracture before surgery was 39° (25 to 70) which improved to 5° at maximum correction and to 13° at latest follow-up. We conclude that surgical release of knee flexion contractures in myelomeningocele improves gait in all children who walk, particularly those with low lumbar lesions. Recurrence of knee flexion contractures after surgical release is most common in those with thoracic lesions who do not achieve independent walking


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 98 - 98
1 Jul 2012
Bansal GJ Kamath S Agarwal S
Full Access

Purpose of the study. Release of tight lateral structures is an integral part of balancing the valgus knee during knee replacement surgery. The posterolateral capsule is released through an inside-out technique. The common peroneal nerve is in close proximity to the capsule during this step. This study was undertaken to determine the distance of the nerve and the safe level for the posterolateral release. Methods. MR scans of the knee of 100 patients were evaluated. The age range of selected patients was 50 to 70 years. The distance of the nerve was measured to the closest point on the posterolateral capsule. Two separate measurements were taken - one 9mm above the joint line indicating the distal femoral resection level and the other 9mm distal to the joint line indicating the level of tibial resection. A third point was at the joint line level. The position of the nerve was also recorded in relation to the cross section of the femur/tibia on a ‘clock-like’ reference. Results. The mean distance of the nerve from the capsule was 13.4mm at level of distal femoral resection, 12.4mm at the level of the joint line and 10.9mm at the level of tibial resection. The minimum distance was 8.2mm at the proximal level, 6.7mm at the level of joint line and 4.7mm at the distal level. Conclusions. The common peroneal nerve is in close proximity to the resected femur and tibia in knee replacement surgery. The posterolateral capsular release should be done at the level of distal femoral resection using electrocautery to minimise risk of damage to the nerve


The Bone & Joint Journal
Vol. 103-B, Issue 6 Supple A | Pages 94 - 101
1 Jun 2021
Roy ME Whiteside LA Ly KK Gauvain MJ

Aims

The aims of this study were to evaluate wear on the surface of cobalt-chromium (CoCr) femoral components used in total knee arthroplasty (TKA) and compare the wear of these components with that of ceramic femoral components.

Methods

Optical profilometry was used to evaluate surface roughness and to examine the features created by the wear process in a knee wear simulator. We developed a method of measuring surface changes on five CoCr femoral components and quantifying the loss of material from the articular surface during the wear process. We also examined the articular surface of three ceramic femoral components from a previous test for evidence of surface damage, and compared it with that of CoCr components.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 634 - 638
1 May 2010
Savarino L Tigani D Greco M Baldini N Giunti A

We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcome which was considered to be the reference standard. The cut-off levels for detection of the ions were obtained by measuring the levels in 41 healthy blood donors who had no implants. Based on the clinical and radiological evaluation the patients were divided into two groups with either stable (n = 24) or loosened (n = 35) implants. A significant increase in the mean level of Cr ions was seen in the group with failed implants (p = 0.001). The diagnostic accuracy was 71% providing strong evidence of failure when the level of Cr ions exceeded the cut-off value. The possibility of distinguishing loosening from other causes of failure was demonstrated by the higher diagnostic accuracy of 83%, when considering only patients with failure attributable to loosening. Measurement of the serum level of Cr ions may be of value for detecting failure due to loosening when the diagnosis is in doubt. The other metal ions studies did not have any diagnostic value


The Bone & Joint Journal
Vol. 102-B, Issue 6 Supple A | Pages 49 - 58
1 Jun 2020
Mullaji A

Aims. The aims of this study were to determine the effect of osteophyte excision on deformity correction and soft tissue gap balance in varus knees undergoing computer-assisted total knee arthroplasty (TKA). Methods. A total of 492 consecutive, cemented, cruciate-substituting TKAs performed for varus osteoarthritis were studied. After exposure and excision of both cruciates and menisci, it was noted from operative records the corrective interventions performed in each case. Knees in which no releases after the initial exposure, those which had only osteophyte excision, and those in which further interventions were performed were identified. From recorded navigation data, coronal and sagittal limb alignment, knee flexion range, and medial and lateral gap distances in maximum knee extension and 90° knee flexion with maximal varus and valgus stresses, were established, initially after exposure and excision of both cruciate ligaments, and then also at trialling. Knees were defined as ‘aligned’ if the hip-knee-ankle axis was between 177° and 180°, (0° to 3° varus) and ‘balanced’ if medial and lateral gaps in extension and at 90° flexion were within 2 mm of each other. Results. Of 50 knees (10%) with no soft tissue releases (other than cruciate ligaments), 90% were aligned, 81% were balanced, and 73% were aligned and balanced. In 288 knees (59%) only osteophyte excision was performed by subperiosteally releasing the deep medial collateral ligament. Of these, 98% were aligned, 80% were balanced, and 79% were aligned and balanced. In 154 knees (31%), additional procedures were performed (reduction osteotomy, posterior capsular release, and semimembranosus release). Of these, 89% were aligned, 68% were balanced, and 66% were aligned and balanced. The superficial medial collateral ligament was not released in any case. Conclusion. Two-thirds of all knees could be aligned and balanced with release of the cruciate ligaments alone and excision of osteophytes. Excision of osteophytes can be a useful step towards achieving deformity correction and gap balance without having to resort to soft tissue release in varus knees while maintaining classical coronal and sagittal alignment of components. Cite this article: Bone Joint J 2020;102-B(6 Supple A):49–58


Bone & Joint Research
Vol. 13, Issue 4 | Pages 149 - 156
4 Apr 2024
Rajamäki A Lehtovirta L Niemeläinen M Reito A Parkkinen J Peräniemi S Vepsäläinen J Eskelinen A

Aims. Metal particles detached from metal-on-metal hip prostheses (MoM-THA) have been shown to cause inflammation and destruction of tissues. To further explore this, we investigated the histopathology (aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL) score) and metal concentrations of the periprosthetic tissues obtained from patients who underwent revision knee arthroplasty. We also aimed to investigate whether accumulated metal debris was associated with ALVAL-type reactions in the synovium. Methods. Periprosthetic metal concentrations in the synovia and histopathological samples were analyzed from 230 patients from our institution from October 2016 to December 2019. An ordinal regression model was calculated to investigate the effect of the accumulated metals on the histopathological reaction of the synovia. Results. Median metal concentrations were as follows: cobalt: 0.69 μg/g (interquartile range (IQR) 0.10 to 6.10); chromium: 1.1 μg/g (IQR 0.27 to 4.10); and titanium: 1.6 μg/g (IQR 0.90 to 4.07). Moderate ALVAL scores were found in 30% (n = 39) of the revised knees. There were ten patients with an ALVAL score of 6 or more who were revised for suspected periprosthetic joint infection (PJI), aseptic loosening, or osteolysis. R2 varied between 0.269 and 0.369 for the ordinal regression models. The most important variables were model type, indication for revision, and cobalt and chromium in the ordinal regression models. Conclusion. We found that metal particles released from the knee prosthesis can accumulate in the periprosthetic tissues. Several patients revised for suspected culture-negative PJI had features of an ALVAL reaction, which is a novel finding. Therefore, ALVAL-type reactions can also be found around knee prostheses, but they are mostly mild and less common than those found around metal-on-metal prostheses. Cite this article: Bone Joint Res 2024;13(4):149–156


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results. The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m. 2. (SD 6 kg/m. 2. ). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion. Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening. Cite this article: Bone Jt Open 2024;5(1):20–27


Bone & Joint Research
Vol. 10, Issue 6 | Pages 363 - 369
1 Jun 2021
MacDonald DRW Neilly DW Elliott KE Johnstone AJ

Aims. Tourniquets have potential adverse effects including postoperative thigh pain, likely caused by their ischaemic and possible compressive effects. The aims of this preliminary study were to determine if it is possible to directly measure intramuscular pH in human subjects over time, and to measure the intramuscular pH changes resulting from tourniquet ischaemia in patients undergoing knee arthroscopy. Methods. For patients undergoing short knee arthroscopic procedures, a sterile calibrated pH probe was inserted into the anterior fascial compartment of the leg after skin preparation, but before tourniquet inflation. The limb was elevated for three minutes prior to tourniquet inflation to 250 mmHg or 300 mmHg. Intramuscular pH was recorded at one-second intervals throughout the procedure and for 20 minutes following tourniquet deflation. Probe-related adverse events were recorded. Results. A total of 27 patients were recruited to the study. Mean tourniquet time was 21 minutes (10 to 56). Tourniquet pressure was 300 mmHg for 21 patients and 250 mmHg for six patients. Mean muscle pH prior to tourniquet inflation was 6.80. Muscle pH decreased upon tourniquet inflation, with a steeper fall in the first ten minutes than for the rest of the procedure. Change in muscle pH was significant after five minutes of tourniquet ischaemia (p < 0.001). Mean muscle pH prior to tourniquet release was 6.58 and recovered to 6.75 within 20 minutes following release. No probe related adverse events were recorded. Conclusion. It is possible to directly measure skeletal muscle pH in human subjects over time. Tourniquet ischaemia results in a decrease in human skeletal muscle pH over time during short procedures. Cite this article: Bone Joint Res 2021;10(6):363–369


Abstract. Introduction. Transforming outpatient services is a key commitment set out in the NHS Long Term Plan, with particular emphasis on digital solutions to reduce outpatient follow-up (FU) by 25%. This study looks at the potential for removing knee arthroscopy FU by providing a bespoke multimedia report for each individual patient, generated using the Synergy™ Surgeon App (Arthrex). Methodology. Single District Hospital using a 3 Phase study. Phase 1 – Assessment of cost and environmental impact of outpatient follow up appointments. Phase 2 – Bench marking of existing pathways and patient experience. Phase 3 – Qualitative assessment of multimedia report feedback of 30 patients. Results. Phase 1 – Impact per year for Trust in released clinician time 135hrs. Cost avoidance £40-£60k. Reduction of the carbon footprint from reduced FU of 3132 KgCo2e2. Phase 2 – Deep dive on 2019 n. 353 procedures. 1206 outpatient appointments required. Average 1.2 post-operative appointments. Phase 3 – 87% of patients who received the e-op report needed no further FU. This compares to only 25% using a traditional post op discussion after surgery. 94% of patients felt the report aided their recovery. Conclusions. Reducing patient FU appointments is crucial to the future of the NHS. Achieving this whilst simultaneously improving the quality of patient communication is achievable as this study has demonstrated. The potential scalability of this project to be applied other arthroscopic procedures is enormous. The study has demonstrated patients are comfortable with modern technology and feel it enhances their understanding whilst decreasing the need for routine post-op FU


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 96 - 96
1 Jul 2022
Gabr A Robinson J
Full Access

Abstract. Introduction. The use of MCL “pie-crusting” (selective release of the superficial MCL) to improve arthroscopic access to the posteromedial compartment of the knee for isolated meniscal surgery has been demonstrated. However, there are concerns that MCL pie-crusting with concomitant ACL reconstruction (ACLR) might affect knee stability and outcomes postoperatively. The aim of this study was to compare the functional outcomes between patients who underwent MCL pie-crusting at ACLR with those that did not. Methods. We performed a retrospective review of prospectively collected data from on the National Ligament Registry. 55 patients (33 male and 22 female) who had MCL pie-crusting(PC group) to address a meniscal lesion at the time of ACLR were compared with 65 patients (38 male and 27 female) who underwent isolated primary ACLR. All procedures were performed by a single surgeon at a tertiary centre between October 2013 and March 2019. Results. The mean Follow up was 4.2 years(range 2- 7 years). The mean EQ 5D- VAS scores were 82 and 81 in the PC group and ACLR only group respectively. The mean IKDC scores were 81 and 85 in the PC group and ACLR only group respectively. The mean KOOS scores in the PC group and ACLR only group were: Symptoms (81,87); Pain (89,92); ADLs (94,96), sports and recreation function (81,83), QoL (75,78) respectively. The differences in the scores were not statistically significant. Conclusions. This study demonstrates that pie-crusting of the MCL at the time of ACLR does not significantly affect the functional outcomes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 43 - 43
1 Jul 2022
Bailey M Dewan V Al-Hourani K Metcalfe A Hing C
Full Access

Abstract. Introduction. The paediatric population present unique challenges to the knee surgeon, particularly when treating recurrent patellofemoral instability(PFI), the management of which is poorly standardised. Through the EPPIC BASK National Trainee Collaborative, we aimed to identify which procedures (and in which combination) are being used to surgically manage recurrent PFI in skeletally immature patients across the UK. Methods. A retrospective national service evaluation via a trainee collaborative analysing local trust data between 1st January 2014 and 31st December 2019. Data from institutions registered for EPPIC was compiled and compared to the national guidelines for adults. Results. A total of 333 patients were classified as skeletally immature(radiologically open physes) across 28 hospitals. Mean age was 14.1 years(+/- 4.5) with 64.9% being female. Mean number of procedures performed was 11.9 (+/-16.4). Isolated medial patellofemoral ligament reconstruction (MPFLR) was the most common procedure, performed in 65.8% of patients. Combined MPFLR and TTO was undertaken in 13.2% of patients. Proximal realignment surgery was performed in 5.1% of patients. Lateral releases were performed in 18.3% of patients with 8.4% performed in isolation. Conclusion. This study highlights the national variation in surgical treatment of PFI in skeletally immature patients. The guidance for adults cannot be applied universally to the skeletally immature, and it not always acceptable to delay treatment until physes close. This lack of standardisation within the UK in the management of recurrent PFI in skeletally immature patients highlights the need for a national consensus in appropriate surgical management of this patient population


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 26 - 26
1 Oct 2020
Gustke KA
Full Access

Introduction. The purpose of this study was to determine if better outcomes occur with use of robotic-arm assistance by comparing consecutive series of non-robotic assisted (NR-TKA) and robotic-arm assisted (NR-TKA) total knee arthroplasties with the same implant. Methods. 80 NR-TKAs and then 101 RA-TKAs were performed consecutively. 70 knees in each group that had a minimum two-year follow-up were retrospectively reviewed. Range of motion, Knee Society (KS) scores, and forgotten joint scores (FJS) were compared using Mann-Whitney U tests. Tourniquets, used for all cases, had their inflation time recorded. Component realignment to minimize soft tissue releases was used in both groups with the goal to stay within a mechanical alignment of 3° of varus to 2° of valgus. The use of soft tissue releases for balance were compared. Results. There were no statistical differences in baseline characteristics including pre-operative Knee Society scores between cohorts. The two-year NR-TKA and RA-TKA median KS knee and functional scores were 99.0 and 90.0 and 100.0 and 100.0 respectively. Mann-Whitney U test indicated a statistically significant difference in KS-KS (p<.00001) and near statistically significant difference in KS-FS (p=0.075). The 10-point higher KS-FS is considered a minimal clinically important difference. The median FJS at two years for the NR-TKA was 61.5 and the RA-TKA was 75.0. Although not statistically significant (p=0.1556), the 13.5-point increase in the RA-TKA cohort also represents a minimal clinically important difference. RA-TKA patients had statistically significant 5° higher knee flexion (p<.00001). Desired post-operative coronal alignment was present in 92.9% of NR-TKAs and 94.3% of RA-TKAs. 28.6% more of the RA-TKA cases were able to be balanced without a soft tissue release. Median tourniquet time was only 3.9 minutes longer for the robotic-arm assisted cohort. Conclusion. This comparison study demonstrates potential benefits in use of robotic-arm assistance over manual instrumentation in TKA