A variety of radiological methods of measuring
version of the acetabular component after total hip replacement (THR)
have been described. The aim of this study was to evaluate the reliability
and validity of six methods (those of Lewinnek; Widmer; Hassan et
al; Ackland, Bourne and Uhthoff; Liaw et al; and Woo and Morrey)
that are currently in use. In 36 consecutive patients who underwent
THR, version of the acetabular component was measured by three independent
examiners on plain radiographs using these six methods and compared
with measurements using CT scans. The intra- and interobserver reliabilities
of each measurement were estimated. All measurements on both radiographs
and CT scans had excellent intra- and interobserver reliability
and the results from each of the six methods correlated well with
the CT measurements. However, measurements made using the methods
of Widmer and of Ackland, Bourne and Uhthoff were significantly
different from the CT measurements (both p <
0.001), whereas
measurements made using the remaining four methods were similar
to the CT measurements. With regard to
The Revision Hip Complexity Classification (RHCC) was developed by modified Delphi system in 2022 to provide a comprehensive, reproducible framework for the multidisciplinary discussion of complex revision hip surgery. The aim of this study was to assess the validity, intra-relater and inter-relater
To propose a modified approach to measuring femoro-epiphyseal acetabular roof (FEAR) index while still abiding by its definition and biomechanical basis, and to compare the
Aims. This aim of this study was to assess the
Aims. The aim of the current study was to assess the
Background. Hip dysplasia has traditionally been classified based on the lateral center edge angle (LCEA). A recent meta-analysis demonstrated no definite consensus and a significant heterogeneity in LCEA values used in various studies to define hip dysplasia and borderline dysplasia. To overcome the shortcomings of classifying hip dysplasia based on just LCEA, a comprehensive classification for adult acetabular dysplasia (CCAD) was proposed to classify symptomatic hips into three discrete prototypical patterns of hip instability; lateral/global, anterior, or posterior. The purpose of this study was to assess the
Background. Total hip arthroplasty (THA) in patients with congenital dysplasia of the hip (CDH) is complex and challenging. The Crowe and Hartofilakidis classification systems are the most commonly used. However, neither encompasses the whole spectrum of disease and deformity and therefore does not guide modern surgical options. We present a new classification system which aims to guide surgical strategy by focusing on the three main areas of disease and deformity: Cup defect; De-rotation of femoral neck ante-version; Height of femoral subluxation. Each component is graded from 1–3 based on the severity of deformity and the potential surgical strategy required (with 3 being the most severe). A total numerical score will reflect the overall degree of difficulty which may be used when assessing surgical outcomes. The aim of this study is to assess the
There is no single standardised method of measuring
the orientation of the acetabular component on plain radiographs
after total hip arthroplasty. We assessed the
Introduction. The prevalence of adverse reactions to metal debris (ARMD) associated with metal on metal (MoM) hip arthroplasty has been reported to be as high as 69%. Such findings promoted the development of metal-artefact reducing sequence (MARS)-magnetic resonance imaging (MRI) classifications, with the aim of stratifying soft lesions by severity of disease. The Modified Oxford Classification is a straightforward system that has been shown to correlate with disease progression. Methods. The aim of this study was to test the
Several radiological methods of measuring anteversion
of the acetabular component after total hip replacement (THR) have
been described. These studies used different definitions and reference
planes to compare methods, allowing for misinterpretation of the
results. We compared the
Aims. The aim of this study was to evaluate the
When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans. Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver
Lag screw cut-out is a serious complication of dynamic hip screw fixation in trochanteric hip fractures. Lag screw position is recognised as a crucial factor influencing the occurrence of lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesize that it could enhance the
Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming radiological measurements are currently used to confirm HD. An artificial intelligence (AI) software named HIPPO automatically locates anatomical landmarks on anteroposterior pelvis radiographs and performs the needed measurements. The primary aim of this study was to assess the
Aims. The aim of this study was to perform a cross-cultural adaptation of Oxford Hip Score (OHS) to Indonesian, and to evaluate its psychometric properties. Methods. We performed a cross-cultural adaptation of Oxford Hip Score into Indonesian language (OHS-ID) and determined its internal consistency, test-retest
Early micromotion of hip implants measured with radiostereometric analysis (RSA) is a predictor for late aseptic loosening. Computed Tomography Radiostereometric Analysis (CT-RSA) can be used to determine implant micro-movements using low-dose CT scans. CT-RSA enables a non-invasive measurement of implants. We evaluated the precision of CT-RSA in measuring early stem migration. Standard marker-based RSA was used as reference. We hypothesised that CT-RSA can be used as an alternative to RSA in assessing implant micromotions. We included 31 patients undergoing Total Hip Arthroplasty (THA). Distal femoral stem migration at 1 year was measured with both RSA and CT-RSA. Comparison of the two methods was performed with paired-analysis and Bland-Altman plots. Furthermore, the inter- and intraobserver
Ceramic bearing fracture is a rare complication following implantation using modern day ceramic bearing materials. Revision bearing options in such cases is debated, with the choice between ceramic-on-ceramic and ceramic-on-polyethylene bearings. Revision to a hard on soft bearing raises concerns about potential catastrophic wear secondary to a third-body reaction caused by the fractured ceramic particles. Data was collected retrospectively from the NJR, electronic patient records, revision database and picture archiving and communication system. Templating software was used to determine linear wear between first post-operative radiograph and the latest available follow up. Univariate analysis was used to examine patient demographics and the wear rates for revision of ceramic bearing fractures to ceramic on polyethylene components. The intra and inter-rater
Tenotomy of the iliopsoas tendon has been described as an effective procedure to treat refractive groin pain induced by iliopsoas tendinitis. However, the procedure forces the rectus femoris to act as the primary hip flexor and little is known about the long-term effects of this procedure on the peri-articular muscle envelope (PAME). Studies suggest that iliopsoas tenotomy results in atrophy of the iliopsoas and decreased hip flexion strength with poorer outcomes, increasing the susceptibility for secondary tendinopathy. The aim of this study is to describe changes in the PAME following psoas release. All patients who presented for clinical examination at our hospital between 2016 and 2021 were retrospectively reviewed. Patients who presented after psoas tenotomy with groin pain and who were unable to actively lift the leg against gravity, were included. Pelvic MRI was taken. Qualitative muscle evaluation was done with the Quartile classification system. Quantitative muscle evaluation was done by establishing the cross-sectional area (CSA). Two independent observers evaluated the ipsi- and contralateral PAME twice. The muscles were evaluated on the level: iliacus, psoas, gluteus minimus-medius-maximus, rectus femoris, tensor fasciae lata, piriformis, obturator externus and internus. For the qualitative evaluation, the intra- and inter-observer
Aims. In this study, we aimed to visualize the spatial distribution characteristics of femoral head necrosis using a novel measurement method. Methods. We retrospectively collected CT imaging data of 108 hips with non-traumatic osteonecrosis of the femoral head from 76 consecutive patients (mean age 34.3 years (SD 8.1), 56.58% male (n = 43)) in two clinical centres. The femoral head was divided into 288 standard units (based on the orientation of units within the femoral head, designated as N[Superior], S[Inferior], E[Anterior], and W[Posterior]) using a new measurement system called the longitude and latitude division system (LLDS). A computer-aided design (CAD) measurement tool was also developed to visualize the measurement of the spatial location of necrotic lesions in CT images. Two orthopaedic surgeons independently performed measurements, and the results were used to draw 2D and 3D heat maps of spatial distribution of necrotic lesions in the femoral head, and for statistical analysis. Results. The results showed that the LLDS has high inter-rater
Aims. The aim of the study was to compare two methods of calculating pelvic incidence (PI) and pelvic tilt (PT), either by using the femoral heads or acetabular domes to determine the bicoxofemoral axis, in patients with unilateral or bilateral primary hip osteoarthritis (OA). Methods. PI and PT were measured on standing lateral radiographs of the spine in two groups: 50 patients with unilateral (Group I) and 50 patients with bilateral hip OA (Group II), using the femoral heads or acetabular domes to define the bicoxofemoral axis. Agreement between the methods was determined by intraclass correlation coefficient (ICC) and the standard error of measurement (SEm). The intraobserver reproducibility and interobserver