All licensed doctors are required to revalidate from June 2012. The GMC states that patient feedback should form part of doctors provided evidence. A standardised GMC PSS has been shown to offer a reliable basis for the assessment of professionalism among UK doctors and has been suggested as a tool for
Continuing professional development (CPD) refers
to the ongoing participation in activities that keep a doctor up
to date and fit to practise once they have completed formal training.
It is something that most will do naturally to serve their patients
and to enable them to run a safe and profitable practice. Increasingly,
regulators are formalising the requirements for evidence of CPD,
often as part of a process of
Soon, UK surgeons will need to undergo regular
To examine the feasibility of surgical outcome measures for a children's orthopaedic surgeon when compared with other specialties. Details of procedure codes for 2726 inpatient episodes were used to examine the distribution of procedures and the breadth of diagnoses dealt with by a variety of orthopaedic sub-specialists. The author's practice included 199 surgical cases and was compared with two arthroplasty surgeons (n=971); a spinal surgeon (n=256); a foot and ankle surgeon (n=341) and an upper limb surgeon (n=393). Arthroplasty surgeons can report 50% of their outcomes as primary knee or hip replacements the index procedure for the author is metalwork removal (14.5%). My upper limb colleague could be judged on 25% of his cases (carpal tunnel decompression) and my spinal surgical colleague on 20% of his cases (primary posterior decompression of spinal cord). Only my foot and ankle colleague compared in terms of diversity with 9% of his cases consisting of first metatarsal osteotomy and the next 9% consisting of 1st MTPJ arthrodesis. The proportion of multiple procedures also varies between sub-specialists with 66% of my cases being multiple compared with 38% for the arthroplasty surgeons and 42% for the upper limb surgeons. Foot and ankle has a high rate of multiple procedures (62%) and the spinal surgeons code different procedures at each level in the spine giving the high rates of multiple procedures.Purpose:
Methods & Results:
The incidence of post-operative peri-prosthetic fractures is increasing. This is a consequence of the larger number of revision cases being undertaken, the increase in the use of cementless implants and a number of patients who develop undetected osteolysis as a result of poor follow up. The Vancouver classification has been shown previously, in North America, to be a valid and reliable method for determining the configuration of a periprosthetic fracture. This is essential in directing the fractures further management appropriately and the classification system has been adopted by surgeons throughout the world. The reliability of any classification system depends on the reproducibility between the clinicians who are making the management decisions. We have revalidated this classification system, independently from the original authors, at a centre in Europe. The radiographs from 30 patients with peri-prosthetic fractures were reviewed by 6 expert consultant surgeons, 6 non-experts at registrar level and 6 medical students, who had received no specialist teaching in this area, in order to assess intra and inter-observer reliability and reproducibility. Each observer read the radiographs on 2 separate occasions and classified the fracture according to its type (A, B1, B2, B3, and C). The results were subjected to weighted kappa analysis and were: 0.76 (substantial agreement) for experts; 0.68 (substantial agreement) for non-experts; and 0.61 (substantial agreement) for medical students. Our results confirm the reliability and reproducibility of this classification system. In addition we have shown that substantial agreement can even be found between individuals with no specialist training. This is a classification system that can be reliably used by non-experts, between centres and across continents.
Quality Improvement (QI) is of increasing importance with its inclusion on training curricula and requirement for it in
The Royal College of Surgeons of England (RCS) recently issued guidance regarding the use of re-operation rates in the re-validation of UK based orthopaedic surgeons. Currently, little has been published concerning acceptable rates of re-operation following primary surgical management of orthopaedic trauma, particularly with reference to re-validation. We conducted a retrospective review of patients undergoing a clearly defined re-operation following primary surgical management of trauma between 1. st. January 2010 and 31. st. December 2011. 3688 patients underwent primary procedures while 83 (2.25%; 99%CI = 1.69 to 2.96%) required an unplanned re-operation. The mean age of patients was 46 years (range 2–98) with 46 (55%) males and a median time to re-operation of 34 days (IQR 12–134). Potentially avoidable re-operations occurred in 47 patients (56.6%; 99%CI = 42.6 to 69.8%) largely due to technical errors (46 patients; 55.4%; 99%CI = 41.4 to 68.7%), representing 1.27% (99%CI = 0.87 to 1.83%) of the total trauma workload. Within RCS guidelines 28 day re-operation rates for hip fractures, wrist fractures and ankle fractures were 1.4% (99%CI = 0.5 to 3.3%), 3.5% (99%CI = 0.8% to 12.1%) and 2.48% (99%CI = 0.7 to 7.6%) respectively. We present novel work that has established baseline re-operation rates for index procedures required for
We performed a prospective audit to investigate the comparability of subjective and objective assessment scores of shoulder function following surgery for rotator cuff pathology. A consecutive series of 372 patients underwent surgery for rotator cuff disorders with post-operative follow up over 24 months. 248 patients solely underwent subacromial decompression, whereas 124 had additional rotator cuff repair (93 arthroscopic; 31 open). Assessments were made pre-operatively, and at 3, 6, 12, and 24 post-operative months using the Disabilities of the Arm, Shoulder, and Hand (DASH) score; Oxford Shoulder Questionnaire (OSQ); and the Constant score, which was used as a reference. Standardisation calculations were performed to convert all scores into a 0 to 100 scale, with 100 representing a normal shoulder. The student’s t-test was used to compare the mean score for each subjective tool (DASH and OSQ) with the objective score (Constant) at each time point. Correlation coefficients (Pearson’s) were used to analyse the changes with time (post-operative course). Each statistical test was used for all surgeries collectively and for the individual surgery types. The relationship between the DASH and the Constant score was robust in all types of surgery. The relationship between the Oxford and Constant was generally robust, except in the open rotator cuff group. There was no statistical difference between the mean DASH and Constant scores for all interventions at each time point. A significant difference was seen between the mean Oxford and Constant scores for at least one time point in all but the open rotator cuff repair group. We demonstrate the DASH and Oxford scoring systems would be useful substitutes for the Constant score, obviating the need for the trained investigator and specialist equipment required to perform the Constant score, alongside the associated cost benefits. Further it provides evidence of service, aids appraisal and
Background. A recent Cochrane review has shown that total shoulder arthroplasty (TSA) seems to offer an advantage in terms of shoulder function over hemiarthroplasty, with no other obvious clinical benefits. This is the first study to compare complication rates on a national scale. Methods. All patients (9804 patients) who underwent either TSA or shoulder hemiarthroplasty as a planned procedure between 2005 and 2008 in the English NHS were identified using the hospital episodes statistic database. Data was extracted on 30-day rates of readmission, wound complications, reoperation and medical complications (myocardial infarction (MI) and chest infection (LRTI)), and inpatient 90-day DVT, PE and mortality rates (MR). Revision rate at 18 months was analysed for the whole cohort and, for a subset of 939 patients, 5-year revision rate. Odds ratio (OR) was used to compare groups. Results. Mean age was 70.6 years for the TSA group and 69.3 for hemiarthroaplasty. There were no significant differences in 30-day readmission (0.82% vs. 0.83%, OR 0.99 (95% CI 0.63–1.55)), wound complication (0.57% vs. 0.51%, OR 1.11 (0.63–1.94)), and reoperation rates (0.20% vs. 0.22%, OR 0.89 (0.36–2.19)). 18-month revision was significantly higher in the TSA groups (3.03% vs. 1.76%, OR 1.75 (1.33–2.28), but at 5-years no difference was seen (3.85% vs. 3.67%, OR 0.95 (0.46–1.91). The overall 90-day MR was 0.43% (42 patients). 0.58% had a LRTI and 0.29% had an MI. There were 13 DVTs (0.13%) and 22 PEs (0.22%, 5 fatal). Discussion. Despite concerns regarding osteolysis around the glenoid peg after TSA, revision rates at 5 years were not significantly different to hemiarthroplasty. Except for 18-month revision rates, there were no differences in any of the outcome measures in this study. Methods of national data analysis described in this study can provide benchmark values for future subspecialty
Introduction: Virtual Reality arthroscopic training systems offer the potential for improved training, assessment and evaluation of surgical skills. Of the various virtual reality arthroscopic training systems available, the main limiting factors preventing their use as a standard training tool is the lack of force feedback. No force data is available from in vivo measurements, which would serve as the basis for the development of such a system. Methodology: We attached a six axis force torque (FT) sensor to a standard arthroscopic probe while at the same time making necessary modiþcations to meet the safety and sterility requirements, and measured in vivo the forces and torques generated during various standard tasks of a routine knee arthroscopy. [The procedure was split into 11 separate tasks] A simultaneous video recording of the procedure was made and synchronized to the force torque recording by using an audio signal. A pilot study to evaluate the difference between experienced and less experienced arthroscopists was also undertaken. Results and conclusions: For comparison and evaluation purposes the vectored XY torque recording was used. Comparison between junior and senior arthroscopic surgeons was done by assessing the XY Torque distribution over time and evaluation of the graph patterns generated while performing similar tasks. Though differences can be seen, it did not show any statistical signiþcance. Successful completion of an arthroscopic procedure requires adequate visualization and gentle manipulation of instruments and tissues within the knee. The use of a force torque sensor in arthroscopic training systems will allow detection of and warn when excessive potentially damaging forces are being used. This will provide a means for improving training as well as a method of evaluation, including
The cost of clinical negligence in the UK has continued to rise despite no increase in claims numbers from 2016 to 2019. In the US, medical malpractice claim rates have fallen each year since 2001 and the payout rate has stabilized. In Germany, malpractice claim rates for spinal surgery fell yearly from 2012 to 2017, despite the number of spinal operations increasing. In Australia, public healthcare claim rates were largely static from 2008 to 2013, but private claims rose marginally. The cost of claims rose during the period. UK and Australian trends are therefore out of alignment with other international comparisons. Many of the claims in orthopaedics occur as a result of “failure to warn”, i.e. lack of adequately documented and appropriate consent. The UK and USA have similar rates (26% and 24% respectively), but in Germany the rate is 14% and in Australia only 2%. This paper considers the drivers for the increased cost of clinical negligence claims in the UK compared to the USA, Germany and Australia, from a spinal and orthopaedic point of view, with a focus on “failure to warn” and lack of compliance with the principles established in February 2015 in the Supreme Court in the case of Montgomery v Lanarkshire Health Board. The article provides a description of the prevailing medicolegal situation in the UK and also calculates, from publicly available data, the cost to the public purse of the failure to comply with the principles established. It shows that compliance with the Montgomery principles would have an immediate and lasting positive impact on the sums paid by NHS Resolution to settle negligence cases in a way that has already been established in the USA. Cite this article:
With the established success of the National
Joint Registry and the emergence of a range of new national initiatives for
the capture of electronic data in the National Health Service, orthopaedic
surgery in the United Kingdom has found itself thrust to the forefront
of an information revolution. In this review we consider the benefits
and threats that this revolution poses, and how orthopaedic surgeons
should marshal their resources to ensure that this is a force for
good.