Advertisement for orthosearch.org.uk
Results 1 - 20 of 339
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 42 - 42
19 Aug 2024
de Graeff JJ Kowalska J van der Pas SL van Leeuwen N Willigenburg NW Neve WC de Vries LMA Schreurs BW Nelissen RGHH van Steenbergen LN Poolman R
Full Access

Controversy persists over whether cemented or uncemented fixation is more effective in reducing revision and mortality risks following primary total hip arthroplasty (THA). Despite a shift towards uncemented THA in Europe, Australia, and the US, no consensus exists on superior outcomes. This ambiguity in evidence from randomized controlled trials (RCTs) and observational studies necessitates advanced research methodologies to derive more definitive conclusions. This study investigates the causal impact of THA fixation type on 2-year and 5-year revision rates, along with 90-day mortality, utilizing a regression discontinuity (RD) design in scenarios where fixation choice is guided by patient age. Employing data from the Dutch Arthroplasty Register, we conducted a cohort study on primary THAs for osteoarthritis from 2007 to 2019. A “fuzzy” RD design was executed to compute the Local Average Treatment Effect for subjects around the age-based selection threshold for fixation type. The main outcome of interest was the revision rate at 2 years post-operation. Analysis for the 2-year revision endpoint, covering any cause, included 2,344 females and 1,671 males across 5 hospitals each, with no significant variation in revision rates observed. For the 5-year mark, 1,058 females in 3 hospitals and 214 males in 1 hospital were examined, similarly showing no significant differences. Mortality within 90 days post-operation was also investigated in 5 female and 7 male cohorts, with 2,180 and 2,145 surgeries respectively, yielding no substantial disparities. In conclusion, the RD analysis revealed no notable differences in revision rates at 2 and 5 years or in early mortality based on the fixation method used in THA. These outcomes suggest that the age-based preference for THA fixation may not influence the revision or mortality risk, underscoring the value of RD design in deriving causal insights from observational data


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 20 - 20
1 Jul 2020
Fowler T Aquilina A Blom A Sayers A Whitehouse M
Full Access

Aims. The aim of this study was to conduct evidence synthesis on the available published literature of the impact of the training status of the operating surgeon (trainee vs. consultant) on the survival and revision rate of primary hip and knee replacements. Patients and Methods. We conducted a systematic review according to Cochrane guidelines. Separate searches were performed for hip and knee replacements, with meta-analysis and presentation of results in parallel. We searched MEDLINE and Embase databases from inception to 17 September 2019 and included controlled trials and cohort studies reporting implant survival estimates, or revision rates of hip and knee replacements according to the grade of the operating surgeon. This study was registered with PROSPERO (CRD42019150494). Results. 8 studies (5 hip papers and 3 knee papers) met the inclusion criteria. There was no significant difference in the survival estimates for total hip replacements (THRs) performed by trainees compared to consultants at 5-years follow-up (97.9% vs 98.1%, p = 0.74). Furthermore, there was no significant difference in the revision rate of THRs performed by trainees and consultants at both 5 and 10-year intervals of follow-up (relative risk [RR]: 5yrs = 0.88 (95% CI: 0.46, 1.70; P = 0.71); 10yrs = 0.68 (95% CI: 0.37, 1.26; P = 0.22)). There was no significant difference in the survival estimates at 10-years for total knee replacements (TKRs) performed by trainees compared to consultants (96.2% vs 95.1%, p=0.49). Conclusion. There is no evidence in the existing literature that trainee surgeons have worse outcomes than their consultant colleagues, in terms of the survival, or rate of revision of hip and knee replacements at 5–10 years follow-up. This may mean that there is genuinely no difference or that, in the context of contemporary training programmes, appropriate case-mix selection and supervision of trainees is currently employed


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 41 - 41
1 Apr 2022
Holleyman R Petheram T Reed M Burton P Malviya A
Full Access

Modular femoral stems offer surgeons great flexibility in biomechanical configuration during total hip replacement (THR) however introduce a taper-trunnion articulation known to be a source of additional wear debris through crevice, fretting and galvanic corrosion with mixed material combinations. This study aimed to investigate the influence of the trunnion bearing surface combination on the revision rate following primary total hip replacement (THR). All patients who underwent THR using an Exeter V40 cemented stainless steel stem and monobloc cemented polyethylene acetabular component (uncemented cups excluded to standardise the acetabular bearing surface and fixation) between January 2003 and December 2019 were extracted from the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man. The primary exposure was the head substrate used corresponding to the trunnion bearing. Time-to-event was determined by duration of implantation from primary surgery to revision with cases censored at death or end of available follow-up. Multivariable Cox proportional hazard models were used to identify predictors of all cause revision, adjusted for age, sex, American Association of Anaesthesiologists (ASA) grade, body mass index, surgical indication (osteoarthritis or other), and femoral head size. 229,870 THR were identified (66% female, mean age 73.4 years (SD 9.1) with the majority (91%) performed for osteoarthritis of which 4,598 were revised. Mean time from primary to revision or censoring was 6.8 years (SD 4.0). Multivariable modelling showed CoCr/SS trunnions were associated with a significantly higher risk of revision (hazard ratio (HR) 1.31 (95%CI 1.15 to 1.48, p<0.0001) as compared to SS/SS (reference). Both Alumina/SS (HR 0.74 (0.65 to 0.84), p<0.0001) and Zirconia/SS (HR 0.61 (0.49 to 0.74), p<0.0001) were associated with a significantly lower risk of revision. Ceramic heads on an Exeter stem were associated with significantly improved survivorship compared to metal heads in primary THR. CoCr/SS trunnion articulations had the poorest survivorship which may be contributed to by trunnionosis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 15 - 15
1 Jul 2020
Holleyman R Critchley R Jameson S Mason J Reed M Malviya A
Full Access

Prosthetic joint infections (PJI) are a devastating consequence in total hip arthroplasties (THA) with both significant morbidity and sometimes mortality, posing a significant health economic burden. Studies, both clinical and in-vitro have suggested possible reduction in PJI with the use of ceramic bearings. We have investigated the relationship of ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP) or metal-on-polyethylene (MoP) bearing surface in affecting outcome of revision surgery after primary THA using data collected from National Joint Registry for England and Wales, Northern Ireland and the Isle of Man between 2002 and 2016. We used a competing risk regression model to investigate predictors of each revision outcome, such as infection, dislocation, aseptic revision and all cause revisions. The results were adjusted for age, gender, ASA grade, BMI, indication for surgery, intraoperative complications and implant data. We identified 456,457 THA (228,786 MoP, 128,403 CoC and 99,268 CoP). In a multivariable model, the adjusted risk of revision for PJI was lower with CoC (OR-0.748, p<0.001) and CoP (OR-0.775, p<0.001) when compared to MoP bearing. Additionally there was also a significant reduction in the risk of all cause revision for CoC (OR-0.918, p=0.002) and CoP (0.806, p<0.001), bearings as compared with MoP. The protective effect of ceramic bearing was predominantly seen after two years of implantation with a significant (p<0.0001) reduction of revision for PJI in both CoC (by 42.8%) and CoP (by 41.3%) group. Similarly significant effect was seen for aseptic revision beyond two years and overall all cause revision rate beyond two years reduced by 21.6% for CoC and 27.1% for CoP (p<0.001). Within the limits of registry analysis, this study has demonstrated an association between the use of ceramic bearing and lower rates of revision for all cause revisions especially infection and aseptic loosening. This finding supports the use of ceramic bearings in THA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 51 - 51
1 Jan 2018
de Steiger R Lorimer M Graves S
Full Access

Total Hip Arthroplasty (THA) is a successful operation for the management of end stage hip osteoarthritis (OA) but long term success is limited by wear of the polyethylene bearing surface. The aim of this study was to compare the rate of revision at 15 years in patients <55 who had a THA for OA, and received either cross-linked (XLPE) or conventional non cross-linked polyethylene (non-XLPE). The study population was all patients with primary THAs undertaken for OA from 1999 to 31 December 2016. Outcomes were determined for all procedures, comparing THA performed with non-XLPE and XLPE and including the effect of age, sex, and reason for revision. The principal outcome measure was time to first revision using Kaplan-Meier estimates of survivorship. There were 17,869 procedures recorded for younger patients <55 years of age undergoing THA for OA and using either non XLPE or XLPE. There was a fivefold increase in the rate of revision for procedures using non-XLPE after seven years. The 15 year cumulative percent revision of primary THA performed for OA in patients <55 with non XLPE was 17.4% (95% CI 15.5,19.5) and for XLPE was 6.6% (95%CI 5.5,7.8) HR >7 years =5.3, p<0.001. Non-XLPE and XLPE were combined with three different femoral head bearing surfaces: ceramic, metal and ceramicised metal. Within each bearing surface, XLPE had a lower rate of revision than non-XLPE. For the most common head size of 28mm XLPE had a lower rate of revision. The use of XLPE has resulted in a significant reduction in the rate of revision for younger patients undergoing THA for OA at 15 years. This evidence suggests that longevity of THA is likely to be improved and may enable younger patients to undergo surgery, confident of a reduced need for revision in the long term


Total hip arthroplasty has been constantly evolving with technological improvements to achieve the best survival rates. Although the new implants are under closer surveillance through processes such as Beyond Compliance, orthopaedic surgeons generally tend to look out for the latest implants with good short-term results and hope for better long-term results for these. We questioned whether such an assumption or bias is valid. We analysed the data of Kaplan-Meier estimates of cumulative revisions of primary hip replacement by fixation, stem/cup brand and bearing combinations from the NJR 19th Annual Report published in September 2022. We performed a univariate linear regression analysis to predict the 10- and 15-year revision rates for these different hip implant combinations from the 3- and 5-year revision rates. Thirty-seven implant combinations had their 15-year revision rates reported and 67 had the 10-year revision rates. The correlation co-efficients were 0.43 and 0.58 for the 3-year and 5-year revision rates against 15-year revision rates. Only 17% of the variance in 15-year revision rates could be predicted by a linear regression model from the 3-year revision rate and 32% from the 5-year revision rate. Corresponding values for the 10-year revision rates were 46% and 67%. 95% prediction intervals for the 15-year revision rate were +/− 3.1% from the 3-year revision rate and +/− 2.8% from the 5-year revision rate. Corresponding values for the 10-year revision rates were +/− 1.3% and +/− 1%. 19 of 37 implant combinations showed 15-year revision rate of more than 4%. Average 3-year and 5-year revision rates for this cohort was 1.0% and 1.42% compared to 1.4% and 1.9% for the rest and the difference was statistically significant. Although average early revision rates showed small but significant difference between the groups with lower and higher 15-year revision rates, the prediction intervals for 15-year revision rates for individual hips based on their 3-year and 5-year revision rates are very wide. Three- and 5-year revision rates for primary total hip replacements are poor predictors of 15-year revision rates


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 84 - 84
23 Jun 2023
Devane P
Full Access

At the end of 2018, the NZ Joint Registry introduced a “Surgeon Outlier” policy, whereby each year, if an individual surgeons’ lower 95% confidence interval of their revision rate, measured in revision/100 component years(r/ocys), was above the NZ mean (0.71 r/ocys), that surgeon was required to audit their results with a nominated peer. This study investigates whether outlier surgeons also have high early (1 month and 1 year) revision rates. In 2018, 236 surgeons performed 9,186 total hip arthroplasties in NZ. At the end of 2018, 11 surgeons received notification they were outliers. Results from all surgeons for years 2016, 2017 and 2018 were combined to form the first (pre-notification) time interval, and results from years 2019, 2020 and 2021 were combined to form the second time interval (post-notification). Outlier surgeons performed 2001 total hip replacements in the first time interval and 1947 hips in the second. Early revision rates (1 month and 1 year) of both outlier and nonoutlier surgeons for both time intervals were analysed. Non-outlier surgeons had a consistent mean early revision rate of 0.75% at one month and 1.6% at one year for both time intervals. The 11 outlier surgeons had a higher earlier revision rate of 1.35% at one month and 2.45% at one year for the pre-notification time interval. These values reduced for the post-notification time interval to a revision rate of 1.23% for one month and 2.36% for one year. Poor joint registry results of individual surgeons are often attributed to a poor choice of prosthesis. This study shows early revision rates of outlier surgeons, where prosthesis selection has minimal influence, are also high. A slight improvement in early revision rates of outlier surgeons since introduction of the policy shows it is working


Bone & Joint Open
Vol. 4, Issue 6 | Pages 408 - 415
1 Jun 2023
Ramkumar PN Shaikh HJF Woo JJ Haeberle HS Pang M Brooks PJ

Aims. The aims of the study were to report for a cohort aged younger than 40 years: 1) indications for HRA; 2) patient-reported outcomes in terms of the modified Harris Hip Score (HHS); 3) dislocation rate; and 4) revision rate. Methods. This retrospective analysis identified 267 hips from 224 patients who underwent an hip resurfacing arthroplasty (HRA) from a single fellowship-trained surgeon using the direct lateral approach between 2007 and 2019. Inclusion criteria was minimum two-year follow-up, and age younger than 40 years. Patients were followed using a prospectively maintained institutional database. Results. A total of 217 hips (81%) were included for follow-up analysis at a mean of 3.8 years. Of the 23 females who underwent HRA, none were revised, and the median head size was 46 mm (compared to 50 mm for males). The most common indication for HRA was femoroacetabular impingement syndrome (n = 133), and avascular necrosis ( (n = 53). Mean postoperative HHS was 100 at two and five years. No dislocations occurred. A total of four hips (1.8%) required reoperation for resection of heterotopic ossification, removal of components for infection, and subsidence with loosening. The overall revision rate was 0.9%. Conclusion. For younger patients with higher functional expectations and increased lifetime risk for revision, HRA is an excellent bone preserving intervention carrying low complication rates, revision rates, and excellent patient outcomes without lifetime restrictions allowing these patients to return to activity and sport. Thus, in younger male patients with end-stage hip disease and higher demands, referral to a high-volume HRA surgeon should be considered. Cite this article: Bone Jt Open 2023;4(6):408–415


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims. Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty. Methods. Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery. Results. A total of 41,949 hemiarthroplasties were included. Exeter V40 with a Unitrax head was the most commonly used (n = 20,707, 49.4%). The overall rate of revision was small. A total of 28,201 patients (67.2%) were aged > 80 years. There were no significant differences in revision rates across all designs of hemiarthroplasty in patients of this age at any time. The revision rates for all designs were < 3.5%, three years postoperatively. At subsequent times the ETS and Exeter V40 with a bipolar head performed well in all age groups. The unadjusted ten-year mortality rate for the whole cohort was 82.2%. Conclusion. There was no difference in implant survival between all the designs of hemiarthroplasty in the first three years following surgery, supporting the selection of a cost-effective design of hemiarthroplasty for most patients with an intracapsular fracture of the hip, as determined by local availability and costs. Beyond this, the ETS and Exeter bipolar designs performed well in all age groups. Cite this article: Bone Joint J 2023;105-B(8):864–871


Bone & Joint Open
Vol. 5, Issue 11 | Pages 971 - 976
5 Nov 2024
Baker G Hill J O'Neill F McChesney J Stevenson M Beverland D

Aims. In 2015, we published the results of our ceramic-on-metal (CoM) total hip arthroplasties (THAs) performed between October 2007 and July 2009 with a mean follow-up of 34 months (23 to 45) and a revision rate of 3.1%. The aim of this paper is to present the longer-term outcomes. Methods. A total of 264 patients were reviewed at a mean of 5.8 years (4.6 to 7.2) and 10.1 years (9.2 to 10.6) to determine revision rate, pain, outcome scores, radiological analysis, and blood ion levels. Those who were unwilling or unable to travel were contacted by telephone. Results. The all-cause revision rate at six years was 3.1% (eight THAs), increasing to 8.8% (18 THAs) at ten years. Of these, there were four and then seven bearing-related revisions at six and ten years, respectively. There was a statistically significant deterioration in the visual analogue scale pain score and Oxford Hip Score (OHS) between six and ten years. There were 18 CoM THAs in 17 patients who had a cobalt or chromium level over 4 ppb and ten CoM THAs in nine patients who had a cobalt or chromium level higher than 7 ppb with a statistically significant increase in chromium levels only between the two timepoints. Overall, 84 stems (39.1%) had significant radiolucent lines at ten years compared to 65 (25.5%) at six years. Conclusion. When compared to the original review, there has been a significant deterioration in pain score, OHS, radiograph appearance, and, most critically, survival has fallen to 91.2%, which does not meet the Orthopaedic Data Evaluation Panel (ODEP) 10 A* 95% threshold. Although this bearing is no longer on the market, 2.5% were bearing-related revisions, which have relevance to the discussion around modular dual-mobility implants that have a similar metal interface


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 18 - 18
23 Jun 2023
Morlock M Melsheimer O
Full Access

The early revision rate in elective Total Hip Arthroplasty (THA) three years after surgery in elderly patients over 80 years is significantly lower for cemented stems in the German Arthroplasty Register (EPRD): cemented 3,1% (3.0 – 3.2) vs. uncemented 4.2% (4.1 – 4.3; p < 0.001). However, the mortality rate in elderly patients is elevated for cemented fixation. This study presents a detailed analysis of the influence of stem type and fixation on revision and mortality rate in this patient cohort. Elective primary THA cases for primary Coxarthrosis using uncemented cups from the EPRD data base were analysed (n. 0. = 37,183). Four stem type groups were compared: cementless, cementless with collar, cementless short, and cemented. Stems with at least 300 cases at risk three years after surgery were analysed individually. The reference stem was determined as the stem with the lowest revision rate and at least 1000 cases under surveillance 3 years after surgery (n. 3. = 28,637). The revision rate for cemented stems (2.5% [2.2–1.81] was lower than for uncemented (4.5% [4.2–4.9]; p<0.001) and uncemented short stems (4.2% [3.1–5.7]; p=0.002). The revision rate of uncemented collared stems (2.3% [1.5–3.6]) was similar to cemented stems (p=0.89) and lower than for uncemented stems (p=0.02). One year mortality showed no sig. differences between the groups (p>0.17): cemented 3.2% [2.9–3.6], uncemented 3.4% [3.1–3.7], uncemented short 3.5% [2.5–4.9], uncemented collar 2.0% [1.2–3.2]. “Cementless” and “cementless short” stems should not be used in patients over 80 years due to the higher revision risk. If cementing should be avoided, “cementless collared” stems seem to be a good alternative combined with a tendency for a lower one year mortality rate


The Posterior and Lateral approaches are most commonly used for Total Hip Arthroplasty (THA) in the United Kingdom (UK). Fewer than 5% of UK surgeons routinely use the Direct Anterior Approach (DAA). DAA THA is increasing, particularly among surgeons who have learned the technique during overseas fellowships. Whether DAA offers long-term clinical benefit is unclear. We undertook a retrospective analysis of prospectively collected 10-year, multi-surgeon, multi-centre implant surveillance study data for matched cohorts of patients whose operations were undertaken by either the DAA or posterior approach. All operations were undertaken using uncemented femoral and acetabular components. The implants were different for the two surgical approaches. We report the pre-operative, and post operative six-month, two-year, five-year and 10-year Oxford Hip Score (OHS) and 10-year revision rates. 125 patients underwent DAA THA; these patients were matched against those undergoing the posterior approach through propensity score matching for age, gender and body mass index. The 10-year revision rate for DAA THA was 3.2% (4/125) and 2.4% (3/125) for posterior THA. The difference in revision rate was not statistically significant. Both DAA and Posterior THA pre-operative OHS were comparable at 19.85 and 19.12 respectively. At the six-month time point, there was an OHS improvement of 20.89 points for DAA and 18.82 points for Posterior THA and this was statistically significant (P-Value <0.001). At the two, five and 10-year time-points the OHS and OHS improvement from the pre-operative review were comparable. At the 10-year time point post-op the OHS for DAA THA was 42.63, 42.10 for posterior THA and the mean improvement from pre-op to 10-years post op was 22.78 and 22.98 respectively. There was no statistical difference when comparing the OHS or the OHS mean improvements at the two, five and 10-year point. Whilst there was greater improvement and statistical significance during the initial six month time period, as time went on there was no statistically significant difference between the outcome measures or revision rates for the two approaches


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 19 - 19
7 Jun 2023
Ahmed M Tirimanna R Ahmed U Hussein S Syed H Malik-Tabassum K Edmondson M
Full Access

The incidence of hip fractures in the elderly is increasing. Minimally displaced and un-displaced hip fractures can be treated with either internal fixation or hemiarthroplasty. The aim was identifying the revision rate of internal fixation and hemiarthroplasty in patients 60 years or older with Garden I or II hip fractures and to identify risk factors associated with each method. A retrospective analysis was conducted from 2 Major Trauma Centres and 9 Trauma Units between 01/01/2015 and 31/12/2020. Patients managed conservatively, treated with a total hip replacement and missing data were excluded from the study. 1273 patients were included of which 26.2% (n=334) had cannulated hip fixation (CHF), 19.4% (n=247) had a dynamic hip screw (DHS) and 54.7% (n=692) had a hemiarthroplasty. 66 patients in total (5.2%) required revision surgery. The revision rates for CHF, DHS and hemiarthroplasty were 14.4%, 4%, 1.2% (p<0.001) respectively. Failed fixation was the most common reason for revision with the incidence increasing by 7-fold in the CHF group [45.8% (n=23) vs. 33.3% (n=3) in DHS; p<0.01]. The risk factors identified for CHF revision were age >80 (p<0.05), female gender (p<0.05) and smoking (p<0.05). The average length of hospital stay was decreased when using CHF compared to DHS and hemiarthroplasty (12.6 days vs 14.9 days vs 18.1 days respectively, p<0.001) and the 1 year mortality rate for CHF, DHS and hemiarthroplasty was 2.5%, 2% and 9% respectively. Fixation methods for Garden I and II hip fractures in elderly patients are associated with a higher revision rate than hemiarthroplasty. CHF has the highest revision rate at 14.4% followed by DHS and hemiarthroplasty. Female patients, patients over the age of 80 and patients with poor bone quality are considered high risk for fixation failure with CHF. When considering a fixation method in such patients, DHS is more robust than a screw construct, followed by hemiarthroplasty


The Bone & Joint Journal
Vol. 105-B, Issue 7 | Pages 775 - 782
1 Jul 2023
Koper MC Spek RWA Reijman M van Es EM Baart SJ Verhaar JAN Bos PK

Aims. The aims of this study were to determine if an increasing serum cobalt (Co) and/or chromium (Cr) concentration is correlated with a decreasing Harris Hip Score (HHS) and Hip disability and Osteoarthritis Outcome Score (HOOS) in patients who received the Articular Surface Replacement (ASR) hip resurfacing arthroplasty (HRA), and to evaluate the ten-year revision rate and show if sex, inclination angle, and Co level influenced the revision rate. Methods. A total of 62 patients with an ASR-HRA were included and monitored yearly postoperatively. At follow-up, serum Co and Cr levels were measured and the HHS and the HOOS were scored. In addition, preoperative patient and implant variables and the need for revision surgery were recorded. We used a linear mixed model to relate the serum Co and Cr levels to different patient-reported outcome measures (PROMs). For the survival analyses we used the Kaplan-Meier and Cox regression model. Results. We found that an increase of one part per billion (ppb) in serum Co and Cr levels correlated significantly with worsening of the HHS in the following year. This significant correlation was also true for the HOOS-Pain and HOOS-quality of life sub scores. The overall ten-year survival rate in our cohort was 65% (95% confidence interval (CI) 52.5 to 77.6). Cox regression analysis showed a significant hazard ratio (HR) of 1.08 (95% CI 1.01 to 1.15; p = 0.028) for serum Co level. No significance was found with sex or inclination angle. Conclusion. This study shows that increasing serum Co and Cr levels measured in patients with an ASR-HRA are predictive for deterioration in HHS and HOOS subscales in the following year. Increasing serum Co and Cr should forewarn both surgeon and patient that there is a heightened risk of failure. Continued and regular review of patients with an ASR-HRA implant by measurement of serum Co/Cr levels and PROMs remains essential. Cite this article: Bone Joint J 2023;105-B(7):775–782


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs. However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications. This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture. 5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture. 1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months). Electronic records were used to review revision rates. Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations. Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups. There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up. IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases


Dual mobility cups (DMC) reduce the risk of dislocation in femoral neck fractures (FNF). Direct anterior approach (DAA), historically promoted for better stability, has been developed in recent years for better functional results. The aim of this study was to compare the early functional results of DMC in FNF by DAA versus posterolateral approach (PLA). A prospective study was conducted on a continuous series of patients who received DMC for FNF by DAA or PLA. The primary endpoint was Harris Hip Score and Parker score assessed at the first follow-up visit. Intraoperative complications were collected during hospitalization. One year clinical results and all cause revision rate were also collected. Radiographic data of cup positioning and limb length were evaluated. Fifty-two patients were included in the DAA group and 54 in the PLA group. Two patients were lost to follow-up. The mean age was 72.8 years. There was no significant difference in HHS or Parker score at 3 and 12 months follow up (p=0.6, p= 0.75). DAA was associated with more intraoperative complications with 4 fractures and 1 femoral nerve deficit (p=0.018). There were 3 revisions in the DAA group (1 infection, 1 dislocation, 1 peri prosthetic fracture) and 1 in the PLA group (infection), which was not statistically significant (p=0.34). Cup anteversion was 6° greater and inclination 9° lesser in DAA group (p=0.028, p<0.01). Results suggest that DAA does not provide any early functional benefit in THA-DMC for FNF compared to PLA. It could lead to more intraoperative complications and a higher revision rate. DAA requires an experienced surgeon and careful patient selection


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 61 - 61
19 Aug 2024
Whitehouse MR Patel R French J Beswick A Navvuga P Marques E Blom A Lenguerrand E
Full Access

We investigated the revision rates of primary total hip replacement (THR) reported in the National Joint Registry (NJR) by types of bearing surfaces used. We analysed THR procedures across all orthopaedic units in England and Wales. Our analyses estimated all-cause and cause-specific revision rates. We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with head and shell/liner combinations. We used flexible parametric survival models to estimate adjusted hazard ratios (HR). A total of 1,026,481 primary THRs performed between 2003–2019 are included in the primary analysis (Monobloc: n=378,979 and Modular: n=647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n=7,381 and Modular: n=13,488). Compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the all-cause risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome or stainless steel head and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any post-operative period. Compared to patients with a cobalt chrome head and HCLPE liner primary THR, the all-cause risk of revision for modular acetabular implant varied non-constantly. THRs with a delta ceramic or oxidised zirconium head and HCLPE liner had a lower risk of revision throughout the entire post-operative period. The all-cause and indication-specific risk of prosthesis revision, at different time points following the initial implantation, is lower for implants with a delta ceramic or oxidised zirconium head and a HCLPE liner/cup than commonly used alternatives such as cobalt chrome heads and HCLPE liner/cup


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 24 - 24
1 Apr 2022
Partridge T Osborne S Marsh M Holland J
Full Access

We present a consecutive case cohort of the first 100 Birmingham Hip Resurfacing (BHR)'s in 90 patients with a minimum follow up of 20 years. All procedures were performed by a single surgeon having commenced the study in 1998. The original cohort included 68 males with 75 hips (7 bilateral) and 22 females with 25 hips (3 bilateral). The mean age at index procedure was 52. Patients were recalled to review in clinic as per Medicines and Healthcare products Regulatory Agency guidelines with x-rays, metal ions and Harris Hip Scores recorded. After a minimum of 20 year follow-up review the known overall revision rate is 11%. 11 have died and 7 have been lost to review. In males the known revision rate is 4/75 (5%), 3 of which were due to early fractures and 1 revision for infection at 5 years. The known revision rate in females is 7/25 (28%) of which 6 were due to adverse reactions to metal debris; 3 at 7–8 yrs, 1 at 15 yrs, 2 at 18 years, and 1 at 2 months for avascular necrosis. The mean 20 year metal ions results were cobalt 36.6 nmol/l (range 7.4–232.1) and chromium 32.1 nmol/l (range 6–120.8). The mean Harris hip score was 88.5 (range 38.6–99.8). This case series with 20 years follow-up demonstrates excellent long term survival of the BHRs further to registry BHR data and similar to THR for same age recipients. Applying today's strict criteria for patient selection would likely improve survival rate further. BHR has not demonstrated the catastrophic revision rates associated with some metal-on-metal resurfacing and remains a safe option for those who meet the criteria


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 17 - 17
2 May 2024
Whitehouse M Patel R French J Beswick A Navvuga P Marques E Blom A Lenguerrand E
Full Access

Hip bearing surfaces materials are typically broadly reported in national registry (metal-on-polyethylene, ceramic-on-ceramic etc). We investigated the revision rates of primary total hip replacement (THR) reported in the National Joint Registry (NJR) by detailed types of bearing surfaces used. We analysed THR procedures across all orthopaedic units in England and Wales. Our analyses estimated all-cause and cause-specific revision rates. We identified primary THRs with heads and monobloc cups or modular acetabular component THRs with detailed head and shell/liner bearing material combinations. We used flexible parametric survival models to estimate adjusted hazard ratios (HR). A total of 1,026,481 primary THRs performed between 2003–2019 were included in the primary analysis (Monobloc cups: n=378,979 and Modular cups: n=647,502) with 20,869 (2%) of these primary THRs subsequently undergoing a revision episode (Monobloc: n=7,381 and Modular: n=13,488). Compared to implants with a cobalt chrome head and highly crosslinked polyethylene (HCLPE) cup, the overall risk of revision for monobloc acetabular implant was higher for patients with cobalt chrome or stainless steel head and non-HCLPE cup. The risk of revision was lower for patients with a delta ceramic head and HCLPE cup implant, at any post-operative period. Compared to patients with a cobalt chrome head and HCLPE liner primary THR, the overall risk of revision for modular acetabular implant varied non-constantly. THRs with a delta ceramic or oxidised zirconium head and HCLPE liner had a lower risk of revision throughout the entire post-operative period. The overall and indication-specific risk of prosthesis revision, at different time points following the initial implantation, is reduced for implants with a delta ceramic or oxidised zirconium head and a HCLPE liner/cup in reference to THRs with a cobalt chrome head and HCLPE liner/cup


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 826 - 832
1 Jul 2022
Stadelmann VA Rüdiger HA Nauer S Leunig M

Aims. It is not known whether preservation of the capsule of the hip positively affects patient-reported outcome measures (PROMs) in total hip arthroplasty using the direct anterior approach (DAA-THA). A recent randomized controlled trial found no clinically significant difference at one year postoperatively. This study aimed to determine whether preservation of the anterolateral capsule and anatomical closure improve the outcome and revision rate, when compared with resection of the anterolateral capsule, at two years postoperatively. Methods. Two consecutive groups of patients whose operations were performed by the senior author were compared. The anterolateral capsule was resected in the first group of 430 patients between January 2012 and December 2014, and preserved and anatomically closed in the second group of 450 patients between July 2015 and December 2017. There were no other technical changes between the two groups. Patient characteristics, the Charlson Comorbidity Index (CCI), and surgical data were collected from our database. PROM questionnaires, consisting of the Oxford Hip Score (OHS) and Core Outcome Measures Index (COMI-Hip), were collected two years postoperatively. Data were analyzed with generalized multiple regression analysis. Results. The characteristics, CCI, operating time, and length of stay were similar in both groups. There was significantly less blood loss in the capsular preservation group (p = 0.037). The revision rate (n = 3, (0.6%) in the resected group, and 1 (0.2%) in the preserved group) did not differ significantly (p = 0.295). Once adjusted for demographic and surgical factors, the preserved group had significantly worse PROMs: + 0.24 COMI-Hip (p < 0.001) and -1.6 OHS points (p = 0.017). However, the effect sizes were much smaller than the minimal clinically important differences (MCIDs) of 0.95 and 5, respectively). The date of surgery (influencing, for instance, the surgeon’s age) was not a significant factor. Conclusion. Based on the MCID, the lower PROMs in the capsular preservation group do not seem to have clinical relevance. They do not, however, confirm the expected benefit of capsular preservation reported for the posterolateral approach. Cite this article: Bone Joint J 2022;104-B(7):826–832