Background. Stability of total knee arthroplasty (TKA) is dependent on correct and precise rotation of the femoral component. Multiple differing surgical techniques are currently utilized to perform total knee arthroplasty. Accurate implant position have been cited as the most important factors of successful TKA. There are two techniques of achieving soft gap balancing in TKA; a measured resection technique and a balanced gap technique. Debate still exists on the choice of surgical technique to achieve the optimal soft tissue balance with opinions divided between the measured resection technique and the gap balance technique. In the measured resection technique, the bone resection depends on size of the prosthesis and is referenced to fixed anatomical landmarks. This technique however may have accompanying problems in imbalanced patients. Prediction of gap balancing technique, tries to overcome these fallacies. Our aim in this study was twofold: 1) To describe our methodology of
Conventional instrumented total knee arthroplasty uses fixed angles for bony cuts followed by soft tissue releases to achieve balance. Robotic-assisted surgery allows for soft tissue balancing first then bony resection. The changes to the implant position from conventional instrumented surgery were measured and recorded. A single center, retrospective study reviewed consecutive total knee replacement surgeries over a 12 month period utilizing robotic pre-planning and balancing techniques. Changes to femoral and tibial varus/valgus and femoral rotation from traditional instrumented surgery positions were analyzed.Background
Methods
Active robotics for total knee Arthroplasty (TKA) uses a CAD-CAM approach to plan the correct size and placement of implants and to surgically achieve planned limb alignment. The TSolution One Total Knee Application (THINK Surgical Inc., Fremont, CA) is an open-implant platform, CT-based active robotic surgical system. A multi-center, prospective, non-randomized clinical trial was performed to evaluate safety and effectiveness of robotic-assisted TKA using the TSolution One Total Knee Application. This report details the findings from the IDE. Patients had to be ≥ 21 years old with BMI ≤ 40, Kellgren-Lawrence Grade ≥ 3, coronal deformity ≤ 20°, and sagital flexion contracture ≤ 15° to participate. In addition to monitoring all adverse events (AE), a pre-defined list of relevant major AEs (medial collateral ligament injury, extensor mechanism disruption, neural deficit, periprosthetic fracture, patellofemoral dislocation, tibiofemoral dislocation, vascular injury) were specifically identified to evaluate safety. Bleeding complications were also assessed. Malalignment rate, defined as the percentage of patients with more than a ± 3° difference in varus-valgus alignment from the preoperative plan, was used to determine accuracy of the active robotic system. Knee Society Scores (KSS) and Short Form 12 (SF-12) Health Surveys were assessed as clinical outcome measures. Results were compared to published values associated with manual TKA.Introduction
Methods
Use of a robotic tool to perform surgery introduces a risk of unexpected soft tissue damage due to the uncommon tactile feedback for the surgeon. Early experience with robotics in total hip and knee replacement surgery reported having to abort the procedure in 18–34 percent of cases due to inability to complete preoperative planning, hardware and soft tissue issues, registration issues, as well as concerns over actual and potential soft tissue damage. These can result in significant morbidity to the patient, negating all the desired advantages of precision and reproducibility with robotic assisted surgery. The risk of soft tissue damage can be mitigated by haptic software prohibiting the cutting tip from striking vital soft tissues and by the surgeon making sure there is a clear workspace path for the cutting tool. This robotic total knee system with a semi-active haptic guided technique was approved by the FDA on 8/5/2015 and commercialized in August of 2016. Two year clinical results have not been reported to date. To review an initial and consecutive series of robotic total knee arthroplasties for safety in regard to avoidance of known or delayed soft tissue injuries and the necessity to abort the using the robot to complete the procedure. Report the clinical outcomes with robotic total knee replacement at or beyond two years to demonstrate no delayed effect on expected outcome.Background
Objective
Use of a robotic tool to perform surgery introduces a risk of unexpected soft tissue damage due to the lack of tactile feedback for the surgeon. Early experience with robotics in total hip and knee replacement surgery reported having to abort the procedure in 18–34 percent of cases due to inability to complete preoperative planning, hardware and soft tissue issues, registration issues, as well as concerns over actual and potential soft tissue damage. These damages to the soft tissues resulted in significant morbidity to the patient, negating all the desired advantages of precision and reproducibility with robotic assisted surgery. The risk of soft tissue damage can be mitigated by haptic software prohibiting the cutting tip from striking vital soft tissues and by the surgeon making sure there is a clear workspace path for the cutting tool. This robotic total knee system with a semi-active haptic guided technique was approved by the FDA on 8/5/2015 and commercialized in August of 2016. One year clinical results have not been reported to date. To review an initial and consecutive series of robotic total knee arthroplasties for safety in regard to avoidance of known or delayed soft tissue injuries and the necessity to abort the robotic assisted procedure and resort to the use of conventional implantation. Report the clinical outcomes with robotic total knee replacement at or beyond one year to demonstrate satisfactory to excellent performance.Background
Objective
Recently, axial radiography has received attention for the assessment of distal femur rotational alignment, and satisfactory results have been as compared with the CT method. The purpose of this study was to assess rotational alignment of the femoral component in knee flexion by axial radiography and to compare flexion stabilities achieved by navigational and robotic total knee arthroplasty (TKA). In addition, the authors also evaluated the effects of flexion stability on functional outcomes in these two groups. Sixty-four patients that underwent TKA for knee osteoarthritis with a minimum of follow-up of 1 year constituted the study cohort. Patients in the navigational group (N = 32) underwent TKA using the gap balancing technique and patients in the robotic group (N = 32) underwent TKA using the measured resection technique. To assess flexion stability using axial radiography a novel technique designed by the authors was used. Rotations of femoral components and mediolateral gaps in the neutral position on flexion radiographs was measured and compared. Valgus and varus stabilities under valgus-varus stress loading, and total flexion stabilities (defined as the sum of valgus and varus stability) were also compared, as were clinical outcomes at final follow up visits. A significant difference was found between the navigation and robotic groups for mean external rotation of the femoral component (2.1° and 0.4°, respectively; Both navigational and robotic techniques provide excellent clinical and flexion stability results. Furthermore, axial radiography was found to provide a useful, straightforward means of detecting rotational alignment, flexion gaps, and flexion stability.
Purpose. The purpose of this study was to evaluate the postoperative maximal flexion of
The preoperative prediction of gap balance after robotic total knee arthroplasty (TKA) is difficult. The purpose of this study was to evaluate the effectiveness of a new method of achieving balanced flexion-extension gaps during robotic TKA. Fifty one osteoarthritic patients undergoing cruciate retaining TKA using robotic system were included in this prospective study. Preoperative planning was based on the amount of lateral laxity in extension and flexion using varus stress radiograph. After complete milling by the robot and soft tissue balancing, intra-operative extension and flexion gaps were measured using a tensioning device. Knees were subdivided into three groups based on lateral laxities in 0° and 90° of flexion, as follows; the tight extension group (≥ 2mm smaller in extension than flexion laxity), the tight flexion group (≥ 2mm smaller in flexion than extension laxity), and the balanced group (< 2mm difference between laxities). In addition, intra-operative gap balance results were classified as acceptable (0–3mm larger in flexion than in extension), tight (larger in extension than in flexion) or loose (> 3mm larger in flexion than in extension) based on differences between extension and flexion gaps. During preoperative planning, 34 cases were allocated to the balanced group, 16 to the tight extension group and 1 case was allocated to the tight flexion group. Intra-operative gap balance was acceptable in 46 cases, 4 cases had a tight result, and one case had a loose flexion gap. We concluded that preoperative planning based on the amount of lateral laxity determined using varus stress radiographs may be useful for predicting intraoperative gap balance and help to achieve precise gap balance during robotic TKA.
There are limited previous findings detailed biomechanical properties following implantation with mechanical and kinematic alignment method in robotic total knee arthroplasty (TKA) during walking. The purpose of this study was to compare clinical and radiological outcomes between two groups and gait analysis of kinematic, and kinetic parameters during walking to identify difference between two alignment method in robotic total knee arthroplasty. Sixty patients were randomly assigned to undergo robotic-assisted TKA using either the mechanical (30 patients) or the kinematic (30 patients) alignment method. Clinical outcomes including varus and valgus laxities, ROM, HSS, KSS and WOMAC scores and radiological outcomes were evaluated. And ten age and gender matched patients of each group underwent gait analysis (Optic gait analysis system composed with 12 camera system and four force plate integrated) at minimum 5 years post-surgery. We evaluated parameters including knee varus moment and knee varus force, and find out the difference between two groups.Background
Methods
There are limited previous findings detailed biomechanical properties following implantation with mechanical and kinematic alignment method in robotic total knee arthroplasty (TKA) during walking. The purpose of this study was to compare clinical and radiological outcomes between two groups and gait analysis of kinematic, and kinetic parameters during walking to identify difference between two alignment method in robotic total knee arthroplasty. Sixty patients were randomly assigned to undergo robotic-assisted TKA using either the mechanical (30 patients) or the kinematic (30 patients) alignment method. Clinical outcomes including varus and valgus laxities, ROM, HSS, KSS and WOMAC scores and radiological outcomes were evaluated. And ten age and gender matched patients of each group underwent gait analysis (Optic gait analysis system composed with 12 camera system and four force plate integrated) at minimum 5 years post-surgery. We evaluated parameters including knee varus moment and knee varus force, and find out the difference between two groups.Background
Methods
Introduction. This study sought to evaluate the patient experience and short-term clinical outcomes associated with the hospital stay of patients who underwent robotic arm-assisted total knee arthroplasty (TKA). These results were compared to a cohort of patients who underwent TKA without robotic assistance performed by the same surgeon. Methods. A cohort of consecutive patients undergoing primary TKA for the diagnosis of osteoarthritis by a single fellowship trained orthopaedic surgeon over a 39-month period was identified. Patients who underwent TKA during the year this surgeon transitioned his entire knee arthroplasty practice to robotic assistance were excluded to eliminate selection bias and control for the learning curve. A final population of 538 TKAs was identified. Of these, 314 underwent TKA without robotic assistance and 224 underwent robotic arm-assisted TKA. All patients received the same prosthesis and post-operative pain protocol. Patient demographic characteristics and short-term clinical data were analyzed. Results.
The goals of a total knee arthroplasty include approximation of the function of a normal knee and achievement of balance post-surgery. Accurate bone preparation and the preservation of natural ligaments along with a functional knee design, holds the potential to provide a method of restoring close to normal function. Although conventional knee arthroplasty is considered a successful intervention for end-stage osteoarthritis, some patients still experience reduced functionality and in some cases, require revision procedures. With conventional manual techniques, accurate alignment of the tibial component has been difficult to achieve. Even in the hands of skilled knee surgeons, outliers beyond 2 degrees of the desired alignment may occur in as many as 40%-60% of cases using conventional methods, and the range of component alignment varies considerably. Similarly, for total knee replacement outliers beyond 2 degrees of the desired alignment may occur in as many as 15% of cases in the coronal plane, going up to 40% of unsatisfactory alignment in the sagittal plane. Robotics-assisted arthroplasty has gained increasing popularity as orthopaedic surgeons aim to increase accuracy and precision of implant positioning. With advances in computer generated data, with image free data, surgeons have the ability to better predict and influence surgical outcomes. Based on planned implant position and soft tissue considerations, robotics-assisted systems can provide surgeons with virtual tools to make informed decisions for knee replacement, specific to the needs of the patient. Here, for the first time in a live surgical setting, we assess the accuracy and technique of a novel imageless semiautonomous handheld robotic surgical technique in bi-cruciate retaining total knee arthroplasty (Navio, Smith and Nephew). The system supports image-free anatomic data collection, intraoperative surgical planning and execution of the plan using a combination of robotic burring and saw cut guides.
The purpose of this study is to compare total and rate of caloric energy expenditure between conventional and robotic-arm assisted total knee arthroplasty (TKA) between a high volume “veteran” surgeon (HV) and a lower volume, less experienced surgeon (LV). Two specialized arthroplasty surgeons wore a biometric-enabled shirt and energy expenditure outcomes were measured (total caloric expenditure, kilocalories per minute, heart rate variability, and surgical duration) during 35 conventional (CTKA) and 29 robotic primary total knee arthroplasty (RTKA) procedures.Introduction
Methods
Insall, Laskin and others have taught us that the goal of successful total knee replacement (TKR) is to have well fixed and fitted components in a neutral mechanical axis (MA) with balanced soft tissues. Computer and robotic assisted (C-RAS) TKR with real time validation is an excellent tool to help you to attain these goals. Ritter and others have shown higher early failure rates with TKR's where the final alignment is outside a 3-degree window of the neutral MA. Dalury and Schroer have each shown higher early failure rates in TKR's with postoperative instability and or malalignment. C-RAS TKR helps prevent and significantly lowers the number of TKR outliers that may go on to early aseptic loosening and failure as compared with traditional methods. This featured video was created to show how surgeons can benefit from real-time validation and the kinematic data provided during C-RAS. The system helps in their intraoperative decision-making process and then guides them to make precise bone cuts and balance the soft tissue envelope in a very time efficient and highly repeatable fashion. Additionally, imageless C-RAS breaks away from the paradigm of pre-operative MRI or CT scan imaging studies by no longer requiring such costly procedures. This relatively easy, simple to learn, and cost-efficient procedure is a valuable asset in the operating room, for both the surgeon and patient. Furthermore, it is highly customizable and easily integrated into any surgeon's workflow, technique, and exposure. The viewer will learn the C-RAS TKR simple workflow of Tracking, Registration, Navigation, and Validation. The results of the previously published abstract “Influence of Pre-Operative Deformity on Surgical Accuracy and Time in Robotic-Assisted TKA” JA Koenig; C Plaskos;
While total knee arthroplasty has demonstrated clinical success, final bone cut and final component alignment can be critical for achieving a desired overall limb alignment. This cadaver study investigated whether robotic-arm assisted total knee arthroplasty (RATKA) allows for accurate bone cuts and component position to plan compared to manual technique. Six cadaveric specimens (12 knees) were prepared by an experienced user of manual total knee arthroplasty (MTKA), who was inexperienced in RATKA. For each cadaveric pair, a RATKA was prepared on the right leg and a MTKA was prepared on the left leg. Final bone cuts and final component position to plan were measured relative to fiducials, and mean and standard deviations were compared. Measurements of final bone cut error for each cut show that RATKA had greater accuracy and precision to plan for femoral anterior internal/external (0.8±0.5° vs. 2.7±1.9°) and flexion/extension* (0.5±0.4° vs. 4.3±2.3°), anterior chamfer varus/valgus* (0.5±0.1° vs. 4.1±2.2°) and flexion/extension (0.3±0.2° vs. 1.9±1.0°), distal varus/valgus (0.5±0.3° vs. 2.5±1.6°) and flexion/extension (0.8±0.5° vs. 1.1±1.1°), posterior chamfer varus/valgus* (1.3±0.4° vs. 2.8±2.0°) and flexion/extension (0.8±0.5° vs. 1.4±1.6°), posterior internal/external* (1.1±0.6° vs. 2.8±1.6°) and flexion/extension (0.7±0.6° vs. 3.7±4.0°), and tibial varus/valgus* (0.6±0.3° vs. 1.3±0.7°) rotations, compared to MTKA, respectively, (where * indicates a significant difference between the two operative methods based on 2- Variances testing, with α at 0.05). Measurements of final component position error show that RATKA had greater accuracy and precision to plan for femoral varus/valgus* (0.6±0.3° vs. 3.0±1.4°), flexion/extension* (0.6±0.5° vs. 3.0±2.1°), internal/external (0.8±0.5° vs. 2.6±1.6°), and tibial varus/valgus (0.7±0.4° vs. 1.1±0.8°) than the MTKA control, respectively. In general, RATKA demonstrated greater accuracy and precision of bone cuts and component placement to plan, compared to MTKA in this cadaveric study. For further confirmation, RATKA accuracy of component placement should be investigated in a clinical setting.
Preoperative templating of femoral and tibial components can assist in choosing the appropriate implant size prior to TKA. While weight bearing long limb roentograms have been shown to provide benefit to the surgeon in assessing alignment, disease state, and previous pathology or trauma, their accuracy in size prediction is continually debated due to scaling factors and rotated views. Further, they represent a static time point, accounting for boney anatomy only. A perceived benefit of robotic-assisted surgery is the ability to pre-operatively select component sizes with greater accuracy based on 3D information, however, to allow for flexibility in refining based on additional data only available at the time of surgery. The purpose of this study was to determine the difference of pre-operative plans in size prediction of the tibia, femur, and polyethylene insert. Eighty four cases were enrolled at three centers as part of an Investigational Device Exemption to evaluate a robotic-assisted TKA. All patients had a CT scan as part of a pre-operative planning protocol. Scans were segmented and implant sizes predicted based on the patients boney morphology and an estimated 2mm cartilage presence. Additional information such as actual cartilage presence and soft tissue effects on balance and kinematics were recorded intra-operatively. Utilizing this additional information, surgical plans were fine tuned if necessary to achieve minimal insert thickness and balance. Data from the Preoperative CT plan sizing and final size were compared to determine the percentage of size and within one size accuracy.Introduction
Methods
Introduction.
Background. Intraoperative balancing of total knee arthroplasty (TKA) can be accomplished by either more prevalent but less predictable soft tissue releases, implant realignment through adjustments of bone resection or a combination of both.
Background. The JOURNEY™ II Cruciate-Retaining Total Knee System (JIICR) and the JOURNEY™ II Bi-Cruciate Stabilized Total Knee System (JIIBCS) (both, Smith & Nephew, Memphis, TN, USA) are used for the treatment of end-stage degenerative knee arthritis. Belonging to the JOURNEY family of knee implants, the relatively new devices are designed to provide guided motion. Studies suggest that long-term outcomes of robotic-assisted navigation in total knee arthroplasty (TKA) are superior to the classical approach. This is the first report describing early postoperative outcomes of the NAVIO® robotic-assisted surgical navigation using the JOURNEY™ II family of knee implants. Materials & Methods. In this ongoing study, six investigational sites in the US prospectively enrolled 122 patients (122 TKAs, 64 JIIBCS and 58 JIICR). Patients underwent TKA using the NAVIO system (Figure 1), a next-generation semi-autonomous tool that uses handheld miniaturized robotic-assisted instrumentation that the surgeon manipulates in 6 degrees of freedom, but restricts cutting to within the confines of the pre-designated resection area of the patient's bone. The primary outcome was postoperative mechanical alignment on long leg X-ray at one month postoperative compared to operative target alignment. Alignment within ±3 degrees of the target alignment was considered a success. Results. Average age was 65.7 years (range, 39–79); 60.7% were females. All patients underwent patella resurfacing. Two patients had revision prior to the one-month follow-up visit; two patients withdrew from the study. 95% (112/118) attended the one-month follow-up. Four patients were missing either baseline or follow-up long leg X-ray, resulting in 108 evaluated TKAs. Overall, 92.6% (100/108) of TKAs were within 3 degrees of the target alignment. Of these, 24.1%, 39.8-, 19.4%, and 9.3% were at 0, 1, 2, and 3 degrees of the target alignment, respectively. There were two revisions, one at 18 days postoperative and the second at 27 days postoperative. Discussion. At the one-month follow-up, the NAVIO™