Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 1 - 1
1 Mar 2022
Lacey A Chiphang A
Full Access

16 to 34% of the population suffer from shoulder pain, the most common cause being rotator cuff tears. NICE guidance recommends using ultrasound scan (USS) or MRI to assess these patients, but does not specify which is preferable. This study assesses the accuracy of USS and MRI in rotator cuff tears in a DGH, to establish the most appropriate imaging modality. Patients who had at least two of shoulder ultrasound, MRI or arthroscopy within a seven month period (n=55) were included in this retrospective study. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated using arthroscopy as the true result, and kappa coefficients calculated for each pairing. 59 comparisons were made in total. Sensitivity for MRI in full supraspinatus tears was 0.83, and for USS 0.75. Specificity for MRI in these tears was 0.75, and for USS 0.83. Values were much lower in other tears, which occurred less frequently. USS and MRI completely agreed with each other 61.3% of the time. Both modalities were only completely accurate 50% of the time. Kappa coefficient between arthroscopy and MRI for supraspinatus tears was 0.658, and for USS was 0.615. There was no statistical difference between MRI and USS sensitivity or specificity (p=1), suggesting that one modality cannot be recommended over the other for full supraspinatus tears. They also do not tend to corroborate one another, suggesting that there is no benefit from doing both scans. Further research is needed to see how both modalities can be improved to increase their accuracy


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 47 - 47
1 Aug 2017
Barrack R
Full Access

The role of metal sensitivity or allergy in causing persistent symptoms or failure and need for a revision of a total joint replacement has been the topic of debate and controversy for decades. There was renewed interest in this area with the rise of metal-on-metal hip arthroplasty and the advent of adverse local tissue reactions. This led to an increase in metal ion testing as well as metal sensitivity testing. With the decline of the use of metal-on-metal hip components, this is now mostly an issue in knee arthroplasty. It is well known that a substantial percentage of patients have persistent symptoms following knee replacement. What remains in question is whether allergy to metal or other materials such as PMMA may be a contributing factor. It is accepted that the incidence of positive skin patch tests is higher in symptomatic failed joint replacements. Nickel sensitivity is most common as a positive skin test with up to 15% of patients demonstrating this followed by chromium and cobalt. A recent review by Lachiewicz et al. concluded that there was insufficient evidence to recommend routine or widespread cutaneous or in vitro hypersensitivity testing before primary TKA, that there is no evidence-based rationale to recommend a routine metal allergy screening questionnaire, that there is only anecdotal support for Ni-free implants, and that local dermatitis should be treated with topical steroids. In another article, routine screening for metal allergy was not recommended, however, selective screening for history of sensitivity or unexplained pain or early loosening was suggested. Other experts have recommended a role for utilizing a commercially available alternative to components containing nickel or cobalt in patients thought to be hypersensitive. A recent study, however, concluded that there was no difference in complications, revisions, or reoperations among patients who tested positive with patch testing whether they were treated with standard components or nickel free components. Likewise, a consensus panel published results from the United Kingdom in which cobalt chrome implants were recommended regardless of the patients metal allergy status. Patient perception is important, however, and among patients who report multiple allergies of any kind, a higher percentage are likely to be dissatisfied with their knee replacement. Of more importance are those reporting a specific allergy to metal are substantially more likely to express some dissatisfaction with their components. Metal allergy as a cause of chronic pain and/or early failure of joint replacement is rare if it exists at all. It is always a diagnosis of exclusion. Patients who think they are allergic are probably more likely to be more symptomatic following joint replacement. Whether or not to use a nickel free or hypoallergenic component in such patients remains an area of controversy


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIII | Pages 75 - 75
1 May 2012
Bucknill A Yam T Campton L Robertson P de Steiger R
Full Access

FAI has been implicated in the progression of osteoarthritis (OA) and early detection may allow for treatment, which can slow or halt progression. FAI is a difficult condition to image and there is little objective evidence about imaging accuracy. We aim to measure the accuracy of five imaging modalities. Three blinded observers retrospectively reviewed five different modalities from two age and sex matched groups: A patient group referred to the outpatient clinic with a clinical diagnosis of FAI and a control group who had had CT scans of the pelvis for suspected trauma, where the Pelvic scan had been reported as showing no injuries. The imaging modalities were: Standard x-ray; Antero-Posterior, Lateral; Condition-specific x-ray projections; Dunn view, lateral internal rotation; Standard Computer Tomography (CT) multiplanar reconstruction (MPR); axial, sagittal and coronal; Condition-specific CT MPR; angled axial, angled coronal; 3D modelling; and surface rendered dynamic. We found marked variations in the sensitivity, specificity, Positive Predictive Value (PPV) and Negative Predictiive Value (NPV) for each of the following imaging modalities: Standard X-ray; Sensitivity 51.9; Specificity; 57.1; PPV; 40; NPV; 68.3 Special X-rays; Sensitivity; 66.7; Specificity; 57.1; PPV; 46.1; NPV; 75.7. Standard CT MPR; Sensitivity; 40.7; Specificity; 75.5; PPV; 47.8; NPV; 69.8 Special CT MPR; Sensitivity; 48.1; Specificity; 57.1; PPV; 46.4; NPV; 70.8 Dynamic 3D CT models; Sensitivity; 55.6; Specificity; 69.3; PPV; 42.8; and NPV; 71.8. The Dynamic 3D CT models (where the observer can manipulate the model in real time three dimension to control the perspective) proved to be the most accurate, closely followed by the special X-Ray views, which were also the most sensitive. The Standard CT MPRs were the most specific but had a low sensitivity. This is the first study to measure sensitivity, specificity and PPV and NPV for these imaging modalities in FAI. We recommend the use of condition-specific X-Ray views as well as 3D CT Models for optimal imaging accuracy in this condition. Standard X-Ray views and CTs proved less useful


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 5 - 5
1 Jan 2016
Goto K Kitamura N Kondo E Yokota M Wada S Thoyama H Yasuda K
Full Access

Introduction. Metals used for total knee arthroplasty (TKA) are well known for their good biocompatibility, but may be a source of a release of metal ions that can be a cause of local and systemic adverse effects, aseptic loosening, and hypersensitivity reactions. One of the major difficulties in performing TKA is the selection of implants for patients who are preoperatively diagnosed as subject to metal sensitivity. Alternative solutions in cases of hypersensitivity are implants without metal constituents or metallic implants treated with a non-sensitive surface process. The aim of this study was to evaluate clinical results in patients who had been preoperatively diagnosed with metal sensitivity and who subsequently were provided with the zirconia-ceramic LFA-III TKA, and with a minimum 5-year follow-up. Methods. Five patients (8 knees) with metal sensitivity underwent TKA using cemented zirconia-ceramic LFA-III implants. The LFA-III implant (KYOCERA Medical Co., Japan) is composed of a zirconia ceramic femoral component and a titanium-alloy tibial component with a polyethylene insert. All patients were female andthe average age at the time of surgery was 76.1 years. The average follow-up time was 7.2 years. Clinical and radiographic assessments were conducted with the Knee Society scoring system. Results. No patients except one who had palmoplantar pustulosis preoperatively presented systemic or local dermatitis after surgery. The mean preoperative range of motion of 97.6 degrees improved to a mean of 110.7 degrees at the time of the most recent follow-up. The mean postoperative knee and function scores were 77.1 and 66.9, respectively. Subtle periprosthetic radiolucencies were found in 2 knees after the surgery. Discussion. The zirconia-ceramic LFA-III TKA has performed well over a 5-year period in patients with metal hypersensitivity. Although this implant has a metal tibial component made of titanium, no systemic or local adverse events related to metal hypersensitivity were recorded. Ceramic implants can be an attractive alternative solution for patients suffering from hypersensitivity reactions to metals


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 36 - 36
1 Dec 2015
Lepetsos P Stylianakis A Leonidou A Argyris D Anastasopoulos P Lelekis M Tsiridis E Macheras G
Full Access

In spite of its incidence decreasing to 1% nowadays, prosthesis-related infections remain a research, diagnostic, therapeutic and cost-related problem. Early diagnosis, selection of an appropriate surgical strategy, accurate identification of the responsible microorganisms and construction of an appropriate antibiotic regimen are essential elements of any management strategy. Our study aim was firstly to compare the diagnostic accuracy of conventional periprosthetic tissue culture and culture of fluid derived from vortexing and bath sonication of the explanted hardware and secondly to investigate the role of possible metabolic factors affecting the sensitivity of the sonication method. We investigated 70 patients undergoing revision hip or knee arthroplasty because of loosening of the prostheses, at our institution, between October 2011 and November 2013. Patients’ medical history and demographic characteristics were recorded. We compared the culture of samples obtained by sonication of explanted hip and knee prostheses with conventional culture of periprosthetic tissue for the microbiological diagnosis of prosthetic-joint infection. Infectious Diseases Society of America (IDSA) Guidelines were used for the definition of prosthetic-joint infection. Thirty-two patients had septic loosening and 38 aseptic loosening (48 hip prostheses and 22 knee prostheses). The sensitivity of sonication fluid culture was 81.25% and the sensitivity of conventional tissue cultures was 56.25% (p-value = 0.043). The sensitivity of the sonication method was statistically higher in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis (p-values < 0.05). The sonication method represents a reliable test for the diagnosis of prosthetic – joint infections with a greater sensitivity than the conventional periprosthetic tissue cultures, especially in obese, diabetic patients, with age above 60, in uncemented arthroplasties and in arthroplasties because of primary osteoarthritis


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1256 - 1260
14 Sep 2020
Kader N Clement ND Patel VR Caplan N Banaszkiewicz P Kader D

Aims. The risk to patients and healthcare workers of resuming elective orthopaedic surgery following the peak of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has been difficult to quantify. This has prompted governing bodies to adopt a cautious approach that may be impractical and financially unsustainable. The lack of evidence has made it impossible for surgeons to give patients an informed perspective of the consequences of elective surgery in the presence of SARS-CoV-2. This study aims to determine, for the UK population, the probability of a patient being admitted with an undetected SARS-CoV-2 infection and their resulting risk of death; taking into consideration the current disease prevalence, reverse transcription-polymerase chain reaction (RT-PCR) testing, and preassessment pathway. Methods. The probability of SARS-CoV-2 infection with a false negative test was calculated using a lower-end RT-PCR sensitivity of 71%, specificity of 95%, and the UK disease prevalence of 0.24% reported in May 2020. Subsequently, a case fatality rate of 20.5% was applied as a worst-case scenario. Results. The probability of SARS-CoV-2 infection with a false negative preoperative test was 0.07% (around 1 in 1,400). The risk of a patient with an undetected infection being admitted for surgery and subsequently dying from the coronavirus disease 2019 (COVID-19) is estimated at approximately 1 in 7,000. However, if an estimate of the current global infection fatality rate (1.04%) is applied, the risk of death would be around 1 in 140,000, at most. This calculation does not take into account the risk of nosocomial infection. Conversely, it does not factor in that patients will also be clinically assessed and asked to self-isolate prior to surgery. Conclusion. Our estimation suggests that the risk of patients being inadvertently admitted with an undetected SARS-CoV-2 infection for elective orthopaedic surgery is relatively low. Accordingly, the risk of death following elective orthopaedic surgery is low, even when applying the worst-case fatality rate. Cite this article: Bone Joint J 2020;102-B(9):1256–1260


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 39 - 39
1 Dec 2013
D'Alessio J Eckhoff D Kester M
Full Access

Computational modeling has been used to simulate the natural and prosthetic kinematic and kinetic function in an attempt to compare designs and/or predict a desired motion path from a design. The levels of soft tissue can range from basic ligaments (MCL, LCL, and ACL & PCL) to more complex models. The goal of this study was to evaluate the sensitivity of the Posterior Cruciate ligament in a virtual model and its effects on the kinematic outcome in a commercially available and validated kinematics package (KneeSim, LifeModeler San Clemente, CA). Methods:. KneeSIM is a musculoskeletal modeling environment that is built on the foundation of the ADAMS (MSC Software, Santa Ana CA), a rigid body dynamics solver to compute knee kinematics and forces during a deep knee bend. All parameters are customizable and can be altered by the user. Generic three dimensional models of cruciate retaining components of the femoral, tibial, and patellar are available with the software and were used to provide a common reference for the study. The following parameters were modified for each simulation to evaluate the sensitivity of the PCL in the model: 1) Model without PCL, 2) PCL with default properties, 3) PCL Shifted at femoral origin, 7 mm anterior, 7 mm inferior; tibial origin maintained; 4) PCL with increased stiffness properties (2x default), 5) position in the femur and tibia remained default position and 6) PCL with default properties and location, joint line shifted 4 mm superior. The standard output of tracking the flexion facet center (FFC) motion of the medial and lateral condyles was utilized (Figure 1). Results:. Figure 2 and 3 displays the output of the six conditions tested above. Comparing the curves for the medial and lateral motion show different patterns with the lateral point having more posterior translation than the medial. After approximately 95° of flexion, all cases exhibit an anterior translation in the model. This motion was consistent for all test cases. The model showed no difference with motion either with or without the PCL and with changing the stiffness. Altering the location of the PCL on the femoral insertion had the greatest effect on motion, while shifting the joint line superior was second. The shift of the ligament insertion and changing of the joint line results in the ligament being more parallel to the tibial surface which provides resistance to anterior motion or posterior translation. Discussion:. Although the model was able to discern differences, the inability to highlight variation in motion with and without the PCL suggests that the default parameters are not representative of an experimental or clinical setup. Although it is apparent that KneeSim can be used for comparative assessments between designs, simulations should be designed so as to provide similar boundary conditions. Publications (Colwell et al 2011) did successfully use KneeSim to provide a comparative assessment of CR components; however, only after the default model was altered to match the outcome of the experimental rig. Further analysis of the complexities in soft tissue modeling is warranted


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 94 - 94
1 Feb 2017
Deck J White B
Full Access

The kinematic and kinetic characteristics of the knee after TKR are known to be strongly influenced by the alignment and positioning of the implanted components. In this paper we apply a virtual multi-fiber ligament model to a rigid body model of the post-surgical knee to explore how variations in alignment and positioning affect the predicted behavior of the ligaments and contact forces. We vary the angular and translational positioning of the femoral and tibial TKR components relative to the bone. Meanwhile the proximal and distal insertion sites of the ligaments are held constant relative to the bony structures. We evaluate sensitivity of the ligament balance and peak ligament tension through the passive flexion arc in response to the variation in positioning and alignment of the TKR components. With further development, this work holds the promise of applications in surgical planning and virtual arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 26 - 26
1 May 2016
Mauck J Kebbach M Schulze C Bader R Kluess D
Full Access

Introduction. The influence of the bone mineral density (BMD) on the mechanical behavior of bones can be examined using computer tomography (CT) data and finite element (FE) simulations, because the BMD correlates with the Hounsfield scale (HU) of the CT data. Therefor the material mapping strategy, which is required to assign the HU values to the FE mesh, is of crucial importance. In this study a nodal mapping strategy was analyzed concerning its sensitivity towards FE mesh parameters and an averaging of HU values from the area around the respective nodes. Method. The FE simulation is based on CT data of a human proximal femur. Once the bone shape was reconstructed, the resulting model was meshed with quadratic tetrahedral elements in ABAQUS/CAE and all nodes were assigned an HU value from the CT data by using the respective node coordinates. In this process, the mesh density, the threshold, which could be used to exclude connective tissue and fat from the material mapping process, the considered volume around the nodes and the method of averaging were varied. The material assignment was realized by an HU value dependent, linear elastic material definition. The femur model was clamped at the level of the isthmus and a displacement of 0.5 mm was applied at the femoral head. The evaluation was based on the resulting reaction forces. Results. The sensitivity analysis demonstrated, that threshold and mesh density mainly influenced the reaction force [Fig. 1]. If a threshold was applied, the reaction force increased by about 20 % in average. A threefold increase of the mesh density led to an average gain of the results of about 24 %. For a specific mesh density the curve progressions of the respective results intersected, i.e. an alteration of the considered volume or the method of averaging barely affected the reaction force [Fig. 2, Fig. 3]. Apart from this intersection, the comparison of the small and the large average volume led to a deviation of up to 11 %. On the other hand, the examination of different methods of averaging revealed only a maximum deviation of 4 % between “mean” and “median”. Discussion. The present study indicates, that the material mapping strategy is an influential part of the modeling process, which should be validated to avoid misjudgments of the load situation. Accordingly, the use of a threshold to exclude non-bone tissue could be a helpful tool. But with the exclusion of lower HU values, the load-bearing structure gains stiffness and the reaction force in the femur rises. A finer mesh leads to a higher resolution of the bone structure and, therefore, to a higher accuracy of the results. The “equilibrium” between the different models at the intersection is caused by a more homogeneous distribution of the material property which is increased by a larger considered volume and the method “mean”


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 15 - 15
1 Sep 2012
Macnair R Wimhurst J Jones HW Cahir J Toms A
Full Access

ARMD (Adverse Reaction to Metal Debris) is an increasingly recognised complication of metal on metal hip replacements. The MHRA (Medical and Healthcare Related Devices Agency) have advised a blood cobalt or chromium level above 7 mg/L is a threshold for further investigation, stating that “low levels are reassuring and strongly predict not having an adverse outcome”. Cross-sectional imaging should be performed when levels are above 7 mg/L. We have performed a study investigating the specificity and sensitivity of chromium and cobalt metal ion levels as a screening measure for ARMD. 79 ASR hip replacements were performed at our hospital and 75 (95%) of these underwent a Metal Artefact Reduction Sequence (MARS) MRI scan. All patients (64 hips) who had not undergone revision were invited to take part in this study. 57 patients with 62 hip replacements completed hip and activity scores, had blood cobalt and chromium ion level measurements and 3D-CT to measure acetabular component position. Acetabular component inclination (>50 degrees), small head size (< 51mm) and female gender were significantly correlated with raised chromium (Cr) and cobalt (Co) ion levels. An ARMD was detected using MRI in 18 (29%) of the hips in this study. The incidence of ARMD was significantly higher when chromium concentration was above 7 mg/l (p = 0.02). Chromium ion levels >7 mg/L had a sensitivity of 56% and specificity of 83% for ARMD, and cobalt ion levels >7 mg/L 56% and 76% respectively. 40 patients had cobalt levels <7 mg/L and 33 had chromium levels <7 mg/L, but 8 of these had an ARMD on MRI. All 8 patients had minimal symptoms (Oxford Hip Score ≥ 44 out of 48). The Medicines and Healthcare Products Regulatory Agency (MHRA) has recommended that cobalt and chromium levels be measured in patients with a metal-on-metal hip replacement and cross-sectional imaging performed when these levels are above 7 μg/L. This study has shown that by using this threshold, in patients with this implant combination, the sensitivity and specificity for the detection of ARMD is low and patients with soft tissue disease may be missed. Furthermore the presence of MRI detected ARMD, in the absence of significant clinical symptoms and with metal ion levels <7 μg/L is of concern. MoM implants at risk of failure are associated with raised cobalt and chromium levels. However metal ion analysis alone is not reliable as a screening tool for ARMD, which is often clinically “silent”. We recommend the routine use of MARS MRI as the safest method of ARMD diagnosis in patients with MoM implants


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 40 - 40
1 Apr 2018
Kanojia R
Full Access

The evolution of orthopedic implants has witnessed a great evolution and allowed insights into the various metals and alloys compatible with the human body. However, some recent reports have raised concerns regarding hypersensitivity to several metals used in orthopedic implants. These cases are mostly documented in the field of arthroplasty.

Metal ion release following hip or knee arthroplasty is a known phenomenon and associated immune reactions to these metal ions have been implicated in the causation of these hypersensitivity reactions. These reactions frequently lead to poor outcome following these implant surgeries. We here present two rare cases of metal induced hypersensitivity reactions following orthopedic surgeries. We have also reviewed the literature in this context to look into the various causes of metal reactions, types of implant involved in hypersensitivity, methods of testing and management options in these cases.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 45 - 45
22 Nov 2024
Stoddart C Hennessy C Ashworth J Vaz J Alvand A Kendrick B Palmer A Partington K
Full Access

Aim. Prosthetic joint infection (PJI) is assessed using clinical history and examination, imaging studies and laboratory investigations which inform diagnostic tools such as that proposed by the European Bone and Joint Infection Society to determine the probability of infection. Infection is often confirmed by microbiology culture and histology from intraoperative samples, but ideally a diagnosis of infection is made preoperatively to guide management decisions. At our institution, a tertiary referral centre for PJI, ultrasound (US)-guided synovial biopsy is routinely used as an adjunct to preoperative joint aspiration. Our aim was to evaluate the sensitivity and specificity of microbiology and histology results from US-guided synovial biopsy samples when compared to intraoperative samples. Method. In this retrospective study we analysed all prosthetic hip and knee US-guided biopsies performed at our institution over a 5 year period between 2018 and 2022. Microbiology and histology results from preoperative biopsy samples were individually compared to microbiology and histology findings from intraoperative samples. Results. 381 biopsies were performed; 281 knee, 100 hip. US-guided biopsy results showed strong positive predictive values (PPVs) in hip biopsies (microbiology PPV (79.3%), histology PPV (85.7%)) and knee biopsies (microbiology PPV (77%), histology PPV (85%)). Biopsies showed low sensitivity in predicting intraoperative findings (hip microbiology sensitivity (62%), hip histology sensitivity (31%), knee microbiology sensitivity (70%), knee histology sensitivity (21%). Biopsies showed high specificity for knee (microbiology specificity (89%), histology specificity (97%)) and hip (microbiology specificity (73%), histology specificity (91%)). Conclusions. This study demonstrates that US-guided biopsy is a valuable diagnostic aid for PJI with high specificities and PPVs. Furthermore US-biopsy is valuable when there is limited fluid for aspiration


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim. Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Method. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity. Results. A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA. Conclusions. The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 41 - 41
22 Nov 2024
Copier B Visser D van Oldenrijk J Bos K Veltman W
Full Access

Aim. Periprosthetic joint infection (PJI) is a devasting complication after total hip arthroplasty. Joint aspiration and preoperative biopsy can be helpful diagnostics for PJI. The aim of this study is to evaluate the diagnostic value of preoperative biopsies after inconclusive or dry tap aspiration of the hip in patients undergoing revision hip arthroplasty. Secondarily we will evaluate the diagnostic value of synovial fluid aspiration cultures and peroperative tissue cultures for diagnosing or ruling out PJI. Methods. Patients who underwent diagnostic aspiration and subsequent preoperative biopsy and/or revision surgery between January 2015 and January 2024 were included in the study. Synovial fluid aspirations and tissue samples obtained from biopsy and revision surgery were interpreted using the European Bone and Joint Infection Society criteria for PJI and in close consultation with the microbiologist. Results. 207 Patients were included with 231 synovial fluid aspirations. Sensitivity and specificity of synovial fluid aspiration cultures were 76% and 98%. In 62 patients tissue biopsies were performed, of which 40 after a dry tap. The tissue biopsies after a dry tap aspiration had a sensitivity of 50.0% and a specificity of 95.8%. In 21% tissue biopsies led to the confirmation of PJI in patient with a high suspicion of PJI after dry tap aspiration. In patients with an inconclusive synovial fluid aspiration result the addition of tissue biopsies led to a change in treatment in 14%. In 212 cases revision surgery was performed, intraoperative tissue cultures had a sensitivity and specificity of 83.3% and 99.3%. Conclusions. Diagnosing PJI can be troublesome, especially if synovial fluid aspiration provides a dry tap. Tissue biopsy cultures in patients with a high suspicion of PJI after dry tap aspiration is a feasible way to confirm PJI, in 21% of patients PJI could be confirmed after dry tap aspiration. Ruling out PJI by means of a biopsy after a dry tap aspiration is less successful due to its low sensitivity. Tissue biopsies after an inconclusive aspiration leads to clinically important treatment changes


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 72 - 72
22 Nov 2024
Zouitni A van Oldenrijk J Bos K Croughs PD Yusuf E Veltman W
Full Access

Aim. Periprosthetic joint infection (PJI) is a serious complication after joint arthroplasty. Diagnosing PJI can be challenging as preoperative screening and conventional cultures may be inconclusive. Sonication fluid culturing stands out as a valuable adjunct technique to improve microbiological PJI diagnosis. This study aims to determine the clinical relevance of routinely using sonication for all septic and aseptic revisions. Method. All patients who underwent (partial) hip or knee revision arthroplasty for all causes between 2012 and 2021 at our institution were retrospectively reviewed. Based on the European Bone and Joint Society PJI criteria, we categorized them into three groups: infection confirmed, infection likely, and infection unlikely. We analyzed the clinical, laboratory, and radiological screening that could confirm or refute suspicion of PJI. We analyzed microbiology cultures and the most frequently detected microorganisms. Sensitivity and specificity were calculated for synovial fluid cultures (preoperative), tissue cultures, and sonication fluid cultures. We determined the clinical relevance of sonication as the percentage of patients for whom sonication confirmed (microbiological) PJI diagnosis. Results. 429 patients who underwent (partial) revision of hip (246 patients) or knee (183 patients) arthroplasty were included. Sensitivity and specificity were 69% and 99% for preoperative synovial fluid cultures, 76% and 92% for intraoperative tissue cultures, and 80% and 89% for sonication fluid cultures, respectively. Sonication fluid cultures improved tissue culture sensitivity and specificity to 83% and 99%, respectively. In 12 (11%) out of 110 PJIs, sonication fluid cultures were decisive for confirming the causative pathogen. This was applicable to acute and chronic infections. In 29 (9%) out of 319 aseptic cases, a negative sonication fluid culture could confirm contamination of tissue cultures. Conclusions. Routine sonication fluid cultures enhanced the sensitivity and specificity of PJI diagnostics. In 11% of PJI cases, causative pathogens were confirmed by sonication fluid culture results. Routine sonication may be helpful in confirming contamination of synovial fluid cultures and tissue cultures. Routine sonication fluid culture should be performed in all revision arthroplasties


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 78 - 78
1 Dec 2022
Dilernia FD Watson D Heinrichs D Vasarhelyi E
Full Access

Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus. SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated the sensitivity to killing, comparing WT and CopAZB-deficient USA300 strains. UAMS-1 evidenced a greater sensitivity to SF when compared to USA300 WT, at 12 (p=0.001) and 24 hours (p=0.027). UAMS-1 significantly died at 24 hours (p=0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at 4 (p=0.001), 12 (p=0.005) and 24-hours (p=0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at 4 (p=0.011), 12 (p=0.011), and 24 hours (p=0.011). Both WT and CopAZB-deficient USA300 strains significantly died in SF, evidencing a MBC-Cu of 50µM against USA300 WT (p=0.011). SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. The addition of 10µM of copper was highly toxic for both strains, confirming its bactericidal effect. We evidenced CopAZB-proteins involvement in copper effluxion by demonstrating the high sensitivity of the mutant strain to lower copper concentrations. Thus, we propose CopAZB-proteins as potential targets and the use of exogenous copper as possible treatment alternatives against S. aureus


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 48 - 48
22 Nov 2024
Kimura O Mozella A Cobra H Saraiva A Leal AC
Full Access

Aim. Evaluate if Neutrophil Extracellular Traps related biomarkers (citrullinated histone H3 [H3Cit], cellfree DNA [cfDNA], and myeloperoxidase) are increased in synovial fluid of patients with PJI and investigate the diagnostic accuracy of NET formation biomarkers for PJI. Method. Patients who underwent hip or knee revision total joint arthroplasty were categorised into two groups according to the Second International Consensus Meeting on Musculoskeletal Infection (2018) criteria. Sixteen patients were classified as infected and 16 as non-infected. cf-DNA, myeloperoxidase and H3Cit were measured in synovial fluid collected during surgery. Sensitivity, specificity, and receiver operating characteristic (ROC) curve were calculated. Results. Patients with PJI presented significantly higher levels of synovial fluid cf-DNA (105.5 ng/ml ± 58.3 vs 1.9 ± 1.2, p>0.0001), myeloperoxidase (1575 pg/ml ± 826 vs 50.16 ± 100, p<0.0001) and citrullinated histone H3 (1.688 ± 1.214 vs 13.88 ± 24.4, p < 0.0001). In the ROC curve analyses, the area under the curve for cf-DNA, myeloperoxidase and H3cit were 1 [0.89 – 1], 0.98 [0.86 – 1], and 0.94 [0.8 – 0.99], respectively. The sensitivity for detecting PJI using synovial fluid was 100% for cf-DNA, 93,7% for myeloperoxidase, and 87,5% for H3cit. The sensitivity for cf-DNA and myeloperoxidase was 100%, and 87,5 % for H3cit. Conclusions. Our results show that neutrophils within periprosthetic microenvironment release NETs as part of the bactericidal arsenal to fight infection. These results allow a better understanding of the cellular and molecular processes that occur in this microenvironment, enabling the design of more assertive strategies for the identification of new biomarkers and for a better use of the available ones. Furthermore, novel studies are needed to define whether and how NET-related biomarkers can be useful for the diagnosis of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 47 - 47
22 Nov 2024
Mitterer JA Hartmann SG Simon S Sebastian S Chlud L Hofstaetter JG
Full Access

Background. Two-stage revision arthroplasty is the standard treatment for chronic hip and knee periprosthetic joint infections (PJI). Accurate diagnosis of persistent infections at 2nd stage using established biomarkers and diagnostic criteria is of paramount importance. This study aimed to evaluate the diagnostic value of synovial calprotectin and alpha-defensin, and compare established diagnostic criteria from the International Consensus Meeting (ICM 2018) and the European Bone and Joint Infection Society (EBJIS 2021) to determine persistent PJI at the 2nd stage of a two-stage revision arthroplasty. Methods. We retrospectively analyzed 97 patients who underwent 100 two-stage revisions (hip: 39, knee: 61). Synovial fluid samples were assessed for calprotectin and alpha-defensin levels. ICM 2018 and EBJIS 2021 were applied to all patients undergoing 2nd stage revision. Receiver operating characteristic (ROC) curves and Youden Index were utilized to determine optimal cut-off values, and correlations between biomarkers were evaluated. The microbiological spectrum was analyzed at 2nd stage and re-revision surgery. Results. Calprotectin levels showed a sensitivity of 66.7%, specificity of 32.9%, and accuracy of 38.0% in predicting septic failure. Alpha-defensin showed sensitivity of 28.6%, specificity of 87.8%, and accuracy of 79.2%. Significant correlations included: calprotectin with PMN% (r = 0.471, p = 0.05) and alpha-defensin with WBC (r = 0.830, p < 0.01) in the successful cohort. For septic re-revisions, calprotectin and alpha-defensin were highly correlated (r = 0.969, p < 0.01). ICM correctly diagnosed persistent PJI in 26.7%, while EBJIS diagnosed 24.2%. The microbial spectrum shifted from gram-positive to gram-negative bacteria between reimplantation and re-revision surgeries. Conclusion. Synovial calprotectin and alpha-defensin demonstrated limited accuracy in ruling out persistent PJI at reimplantation. The low sensitivity of current diagnostic criteria, combined with the observed shift in microbial spectrum, underscores the challenges in diagnosing persistent PJI during 2nd stage of a two-stage revisions arthroplasty