Fracture repair occurs by two broad mechanisms:
direct healing, and indirect healing with callus formation. The effects
of bisphosphonates on fracture repair have been assessed only in
models of indirect fracture healing. A rodent model of rigid compression plate fixation of a standardised
tibial osteotomy was used. Ten
We conducted a multicentre two arm double blind randomised controlled trial to assess efficacy of pulsed ultrasound for accelerating the rate of bone healing. Sixty-two
Objective:. To assess efficacy of pulsed ultrasound for accelerating regenerate consolidation. Design:. A multicentre two arm patient and assessor double blind RCT. Setting:. Four UK centres (Edinburgh, Belfast, Liverpool, Bristol). Participants:. 62
Intramedullary nails are a well accepted method of fixing fractures of the femur, however there are several potential complications associated with femoral nail insertion. One under-reported complication is perforation of the anterior cortex of the distal femur. Cortical perforation is well documented in immature bone however there is little evidence of perforation in
Introduction. The current investigation includes a retrospective review of the experience of five Institutions with distal femur megaprostheses for tumor over a twenty year period, to analyze the incidence and etiology of failure, using a new classification system based upon the failure modes. Methods. Between 1974 and 2008, 2174 patients underwent primary limb preservation for a benign or malignant extremity tumor using a metallic megaprosthesis at five Institutions, 951 (43.7%) were distal femur replacements. Retrospective analysis of complications according to the Letson and Ruggieri Classification was performed and Kaplan-Meier curves of implant survival were defined. Segmental megaprosthetic reconstruction failures were categorized as mechanical and non-mechanical failures. Results. A total of 951
Prophylactic pinning of the contralateral hip in the treatment of slipped upper femoral epiphysis has been shown to be safer than continued observation of the contralateral hip. This treatment remains controversial due to the potential for harm caused to an apparently unaffected hip. There is evidence that pinning of an already slipped epiphysis causes growth disturbance of the proximal femur, however Hagglund showed that there is not necessarily growth arrest at the physis after pinning, as the slip occurs at the hypertrophic layer of the growth plate with no damage to the germative layer. This was confirmed by Guzzanti who confirmed that a single screw provided epiphyseal stability and preserved potential for growth. We conducted a pilot study to determine whether prophylactic pinning affects subsequent growth of the unaffected hip. In order to determine the effect of prophylactic pinning we compared radiographs
Distraction osteogenesis (callotasis) has been widely used in patients with limb-length inequality or massive bone defects. This procedure, however, may be associated with a high incidence of physical and psychosocial complications. Callotasis telescoping on a locked intramedullary nail has been used to shorten the period of external fixation. Little attention has been given to the use of locked intramedullary nails in the treatment of complications after callotasis. Between 1990 and 1999, we used locked intramedullary nailing in 27 patients for the treatment of complications after distraction osteogenesis. There were 17 men and ten women with a mean age of 33.2 years (16 to 66). The nail was inserted at a mean of 3.4 weeks (0 to 15) after removal of the external fixator. Simultaneous autogenous bone grafting and soft-tissue reconstruction were also undertaken in seven and two patients, respectively. There was consolidation of the callus or docking site in all patients at a mean of 6.4 months (2 to 14) after surgery. The mean shortening of the callus was 0.7 cm (0 to 2.5). Two patients had infection at the site of a distal screw which resolved after removal of the nail. In 17 patients the nail was removed at a mean of 26 months after its insertion. Locked intramedullary nails are useful in treating complications after distraction osteogenesis in
Introduction. Distal radius fractures (DRF) are a common injury in the A&E departments, being a major cause of disability of the upper extremity. The aim of this prospective study is to assess the possible association between objective physical variables such as wrist range of movement (ROM), radiological parameters, and upper extremity disability (measured by the DASH questionnaire), after conservative treatment of DRF. Patients and methods. 44 patients with non-operatively managed DRF were enrolled in a prospective cohort study from July 2007 till September 2009. Inclusion criteria: unilateral DRF in
INTRODUCTION. Autologous bone grafts are considered gold standard in the repair of bone defects. However they are limited in supply and are associated with donor site morbidity. This has led to the development of synthetic bone graft substitute (BGS) materials, many of which have been reported as being osteoinductive. The structure of the BGS is important and bone formation has been observed in scaffolds with a macroporous morphology. Smaller pores termed ‘strut porosity’ may also be important for osteoinduction. The aim of this study was to compare the osteoinductive ability of one silicate-substituted calcium phosphate (SiCaP) with differing strut porosities in an ectopic ovine model. Our hypothesis was that SiCaP with greater strut porosity would be more osteoinductive. METHODS. The osteoinduction of SiCaP BGS with two different strut porosities (AF and AF++) was investigated. The materials had an identical chemical composition and morphological structure but differing strut porosity (AF=22.5%, AF++=47%). Implants were inserted into the paraspinal muscles in
Introduction. The combined incubation of a composite scaffold with bone marrow stromal cells in a perfusion bioreactor could make up a novel hybrid graft material with optimal properties for early fixation of implant to bone. The aim of this study was to create a bioreactor activated graft (BAG) material, which could induce early implant fixation similar to that of allograft. Two porous scaffold materials incubated with cells in a perfusion bioreactor were tested in this study. Methods and Materials. Two groups of 8
Proximal humeral fractures (PHFs) are common. There is increasing evidence that most of these fractures should be treated conservatively. However, recent studies have shown an increase in use of operative treatment. The aim of this study was to identify the trends in the incidence and methods of treatment of PHFs in Finland. The study included all Finnish inhabitants aged ≥ 16 years between 1997 and 2019. All records, including diagnostic codes for PHFs and all surgical procedure codes for these fractures, were identified from two national registers. Data exclusion criteria were implemented in order to identify only acute PHFs, and the operations performed to treat them.Aims
Methods
In order to determine whether and for whom serial radiological evaluation is necessary in one-part proximal humerus fractures, we set out to describe the clinical history and predictors of secondary displacement in patients sustaining these injuries. Between January 2014 and April 2016, all patients with an isolated, nonoperatively treated one-part proximal humerus fracture were prospectively followed up. Clinical and radiological evaluation took place at less than two, six, 12, and 52 weeks. Fracture configuration, bone quality, and comminution were determined on the initial radiographs. Fracture healing, secondary displacement, and treatment changes were recorded during follow-up.Aims
Patients and Methods
The aim of this study was to compare the incidence of anterior knee pain after antegrade tibial nailing using suprapatellar and infrapatellar surgical approaches A total of 95 patients with a tibial fracture requiring an intramedullary nail were randomized to treatment using a supra- or infrapatellar approach. Anterior knee pain was assessed at four and six months, and one year postoperatively, using the Aberdeen Weightbearing Test – Knee (AWT-K) score and a visual analogue scale (VAS) score for pain. The AWT-K is an objective patient-reported outcome measure that uses weight transmitted through the knee when kneeling as a surrogate for anterior knee pain.Aims
Patients and Methods
This study aimed to investigate the role of quantitative histological
analysis in the diagnosis of fracture-related infection (FRI). The clinical features, microbiology culture results, and histological
analysis in 156 surgically treated nonunions were used to stratify
the likelihood of associated infection. There were 64 confirmed
infected nonunions (one or more confirmatory criteria: pus, sinus,
and bacterial growth in two or more samples), 66 aseptic nonunions
(no confirmatory criteria), and 26 possibly infected nonunions (pathogen
identified from a single specimen and no confirmatory criteria).
The histological inflammatory response was assessed by average neutrophil
polymorph (NPs) counts per high-power field (HPF) and compared with
the established diagnosis.Aims
Patients and Methods
The aim of this double-blind prospective randomised controlled
trial was to assess whether low intensity pulsed ultrasound (LIPUS)
accelerated or enhanced the rate of bone healing in adult patients
undergoing distraction osteogenesis. A total of 62 adult patients undergoing limb lengthening or bone
transport by distraction osteogenesis were randomised to treatment
with either an active (n = 32) or a placebo (n = 30) ultrasound
device. A standardised corticotomy was performed in the proximal
tibial metaphysis and a circular Ilizarov frame was used in all
patients. The rate of distraction was also standardised. The primary
outcome measure was the time to removal of the frame after adjusting
for the length of distraction in days/cm for both the per protocol
(PP) and the intention-to-treat (ITT) groups. The assessor was blinded
to the form of treatment. A secondary outcome was to identify covariates affecting
the time to removal of the frame.Aims
Patients and Methods
Bisphosphonates are widely used as first-line treatment for primary and secondary prevention of fragility fractures. Whilst they have proved effective in this role, there is growing concern over their long-term use, with much evidence linking bisphosphonate-related suppression of bone remodelling to an increased risk of atypical subtrochanteric fractures of the femur (AFFs). The objective of this article is to review this evidence, while presenting the current available strategies for the management of AFFs. We present an evaluation of current literature relating to the pathogenesis and treatment of AFFs in the context of bisphosphonate use.Objectives
Methods
The aim of this study was to report the outcome following primary
fixation or a staged protocol for type C fractures of the tibial
plafond. We studied all patients who sustained a complex intra-articular
fracture (AO type C) of the distal tibia over an 11-year period.
The primary short-term outcome was infection. The primary long-term
outcome was the Foot and Ankle Outcome Score (FAOS).Aims
Patients and Methods
We prospectively assessed the diagnostic accuracy
of the gravity stress test and clinical findings to evaluate the stability
of the ankle mortise in patients with supination–external rotation-type
fractures of the lateral malleolus without widening of the medial
clear space. The cohort included 79 patients with a mean age of
44 years (16 to 82). Two surgeons assessed medial tenderness, swelling
and ecchymosis and performed the external rotation (ER) stress test
(a reference standard). A diagnostic radiographer performed the
gravity stress test. For the gravity stress test, the positive likelihood ratio (LR)
was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and
the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate
change from the pre-test probability. Medial tenderness, both alone
and in combination with swelling and/or ecchymosis, indicated a
small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47),
whereas swelling and ecchymosis indicated only minimal changes (positive
LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). In conclusion, when gravity stress test results are in agreement
with clinical findings, the result is likely to predict stability
of the ankle mortise with an accuracy equivalent to ER stress test
results. When clinical examination suggests a medial-side injury,
however, the gravity stress test may give a false negative result. Cite this article:
We have studied the effect of shortening of the femoral neck and varus collapse on the functional capacity and quality of life of patients who had undergone fixation of an isolated intracapsular fracture of the hip with cancellous screws. After screening 660 patients at four university medical centres, 70 patients with a mean age of 71 years (20 to 90) met the inclusion criteria. Overall, 66% (46 of 70) of the fractures healed with >
5 mm of shortening and 39% (27 of 70) with >
5° of varus. Patients with severe shortening of the femoral neck had significantly lower short form-36 questionnaire (SF-36) physical functioning scores (no/mild (<
5 mm) vs severe shortening (>
10 mm); 74 vs 42 points, p <
0.001). A similar effect was noted with moderate shortening, suggesting a gradient effect (no/mild (<
5 mm) vs moderate shortening (5 to 10 mm); 74 vs 53 points, p = 0.011). Varus collapse correlated moderately with the occurrence of shortening (r = 0.66, p <
0.001). Shortening also resulted in a significantly lower EuroQol questionnaire (EQ5D) index scores (p = 0.05). In a regression analysis shortening of the femoral neck was the only significant variable predictive of a low SF-36 physical functioning score (p <
0.001).
Small animal models of fracture repair primarily investigate
indirect fracture healing via external callus formation. We present
the first described rat model of direct fracture healing. A rat tibial osteotomy was created and fixed with compression
plating similar to that used in patients. The procedure was evaluated
in 15 cadaver rats and then Objectives
Methods