Advertisement for orthosearch.org.uk
Results 1 - 20 of 66
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1184 - 1188
1 Nov 2023
Jennison T Ukoumunne OC Lamb S Goldberg AJ Sharpe I

Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The rate of survival was 95.4% (95% confidence interval (CI) 91.6 to 97.5) at one year, 87.7% (95% CI 81.9 to 91.7; n = 124) at three years and 77.5% (95% CI 66.9 to 85.0; n = 57) at five years. Revision-specific implants had a better survival than when primary implants were used at revision. A total of 50 patients (21.9%) had further surgery; 19 (8.3%) underwent reoperation in the first 12 months. Cox regression models were prepared. In crude analysis the only significant risk factors for failure were the use of cement (hazard ratio (HR) 3.02 (95% CI 1.13 to 8.09)) and the time since the primary procedure (HR 0.67 (95% CI 0.47 to 0.97)). No risk factors for failure were identified in multivariable Cox regression modelling. Conclusion. Revision TAAs have good medium term survival and low rates of further surgery. New modular revision implants appear to have improved the survival compared with the use of traditional primary implants at revision. Cite this article: Bone Joint J 2023;105-B(11):1184–1188


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 46 - 52
1 Jan 2024
Hintermann B Peterhans U Susdorf R Horn Lang T Ruiz R Kvarda P

Aims. Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results. The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative survival rates of the revised ankles were 81% (95% confidence interval (CI) 74% to 88%), 74% (65% to 82%), and 70% (61% to 79%) at five, ten, and 15 years, respectively. Comorbidities prior to primary TAA, aseptic loosening, instability, or grafting of cysts were found to be the most common risk factors for secondary revision. The median value for preoperative pain, as assessed using the visual analogue scale, declined from 6 (interquartile range (IQR) 5 to 8) to 2 (IQR 0 to 5) (p < 0.001) and the mean American Orthopaedic Foot and Ankle Society ankle-hindfoot score improved from 43 (SD 17) preoperatively to 70 (SD 20) (p < 0.001) at last follow-up. Conclusion. Revision TAA offers acceptable survival rates after 15 years; it therefore offers a valuable option for treatment of implant failure in carefully selected cases. Although patient-reported outcomes improve substantially, the degree of improvement reported following primary TAA is not achieved. Cite this article: Bone Joint J 2024;106-B(1):46–52


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 1 - 1
4 Jun 2024
Jennison T Goldberg A Sharpe I
Full Access

Introduction. Despite the increasing numbers of ankle replacements that are being performed there are still limited studies on the survival of ankle replacements and comparisons between different implants. The primary aim of this study is to link NJR data with NHS digital data to determine the true failure rates of ankle replacements. Secondary outcomes include analysis risk factors for failure, patient demographics and outcomes of individual prosthesis. Methods. A data linkage study combined National Joint Registry Data and NHS Digital data. The primary outcome of failure is defined as the removal or exchange of any components of the implanted device inserted during ankle replacement surgery. Life tables and Kaplan Meier survival charts demonstrated survivorship. Cox proportional hazards regression models with the Breslow method used for ties were fitted to compare failure rates. Results. 5,562 primary ankle replacement were recorded on the NJR. The 1-year survivorship was 98.8% (95% CI 98.4%–99.0%), 5-year survival in 2725 patients was 90.2% (95% CI 89.2%–91.1%), and 10-year survival in 199 patients was 86.2% (95% CI 84.6%–87.6%). When using a Cox regression model for all implants with over 100 implantations using the Infinity as the reference, only the Star (Hazard ratio 1.60 95% CI 0.87–2.96) and Inbone (HR 0.38 95% CI 0.05–2.84) did not produce significantly worse survivorship. Conclusion. Ankle replacements have increased in numbers over the past decade, and the currently used implants have lower failure rates than older prosthesis. It is expected that in the future the outcomes of ankle replacements will continue to improve


The Bone & Joint Journal
Vol. 105-B, Issue 3 | Pages 301 - 306
1 Mar 2023
Jennison T Ukoumunne O Lamb S Sharpe I Goldberg AJ

Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants. Cite this article: Bone Joint J 2023;105-B(3):301–306


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_19 | Pages 5 - 5
1 Nov 2016
Drampalos E Karim T Clough T
Full Access

Aim. To examine the mid-term survival, clinical and patient reported outcomes of the silastic 1. st. metatarsophalangeal joint replacement for the treatment of end stage hallux rigidus. Methods. We reviewed 83 consecutive silastic arthroplasties performed in 79 patients for end stage hallux rigidus. There were 3 men and 76 women; mean age 63 years (range 45–78 years). No patient was lost to follow up. Average follow-up was 5.3 years (1.1–11.3 years). The EQ 5D–5L Health index, Manchester-Oxford Foot Questionnaire (MOXFQ), visual analogue scale (VAS) of pain and overall satisfaction rate (Likert scale) were collected for patient reported outcomes. Results. 2 patients required revision; 1 for early infection (2 months) and 1 for stem breakage (10 years 1 month). 5 patients reported lateral metatarsalgia, 2 patients reported neuropathic pain, 6 patients developed superficial infection which fully responded to oral antibiotics, and 1 patient developed interphalangeal joint pain. 2 patients died in the cohort. Pre-operative mean MOXFQ was 44, mean EQ5D Index was 0.564 and VAS was 6.97. At mean follow-up of 5.3 years, the mean MOXFQ was 12.7 (0–57), the mean EQ5D Index was 0.851 (−0.02–1) and the mean VAS was 1.67 (0–8). The mean range of motion was 35° (30° dorsiflexion and 5° plantarflexion). The overall satisfaction rate was 90.2%. The implant survival rate was 97.6%. Conclusions. The silastic big toe arthroplasty offers excellent clinical mid term survival and functional outcomes and could be considered as an attractive alternative to traditional fusion for end stage hallux rigidus


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_14 | Pages 25 - 25
1 Dec 2015
Dall G Clement N McDonald D Ahmed I Duckworth A Shalaby H McKinley J
Full Access

We present a review of 97 consecutive BioPro. ®. metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum of five years follow-up. The mean age of the cohort was 55 (22 to 74) years. No patient was lost to follow-up. There were 15 revisions performed, one for infection, two for osteolysis, and 12 for pain. The all cause survival rate at five years was 85.6% (95% confidence interval (CI) 83.5 to 87.9). Younger age was a significant predictor of revision (odds ratio 1.09, 95% CI 1.02 to 1.17, p=0.014) on excluding infection and adjusting for confounding variables (Cox regression). Significant improvements were demonstrated at 5 years in the Manchester Oxford foot questionnaire (13.9, 95% CI 10.5 to 17.2) and in the physical component of the short form 12 score (6.5, 95% CI 4.1 to 8.9). The overall satisfaction rate was 72%. The cost per quality-adjusted-life-year at 5 years, accounting for a 3% per year revision rate, was £3,714. The BioPro offers good short to mid-term functional outcome and is a cost effective intervention. The relative high revision rate is associated with younger age and the use of this implant may be limited to older patients


The Bone & Joint Journal
Vol. 98-B, Issue 7 | Pages 945 - 951
1 Jul 2016
Clement ND MacDonald D Dall GF Ahmed I Duckworth AD Shalaby HS McKinley J

Aims. To examine the mid-term outcome and cost utility of the BioPro metallic hemiarthroplasty for the treatment of hallux rigidius. Patients and Methods. We reviewed 97 consecutive BioPro metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum follow-up of five years. There were 19 men and 61 women; their mean age was 55 years (22 to 74). No patient was lost to follow-up. Results. A total of 12 patients (15 first metatarso-phalangeal joints (MTPJs)) required a revision; one for infection, two for osteolysis and 12 for pain. The all cause rate of survival at five years was 85.6% (95% confidence interval (CI) 83.5 to 87.9). Younger age was a significant predictor of revision (odds ratio 1.09, 95% CI 1.02 to 1.17, p = 0.014) on excluding infection and adjusting for confounding variables (Cox regression). Significant improvements were demonstrated at five years in the Manchester Oxford Foot Questionnaire (13.9, 95% CI 10.5 to 17.2) and in the physical component of the Short Form-12 score (6.5, 95% CI 4.1 to 8.9). The overall rate of satisfaction was 75%. The cost per quality adjusted life year at five years, accounting for a 14% rate of revision was between £4431 and £6361 depending on the complexity and morbidity of the patient. Conclusion. The BioPro hemiarthroplasty offers good short to mid-term functional outcome and is a cost effective intervention. The relatively high revision rate is associated with younger age and perhaps the use of this implant should be limited to older patients. Cite this article: Bone Joint J 2016;98-B:945–51


The Bone & Joint Journal
Vol. 102-B, Issue 2 | Pages 220 - 226
1 Feb 2020
Clough TM Ring J

Aims

Arthroplasty for end-stage hallux rigidus (HR) is controversial. Arthrodesis remains the gold standard for surgical treatment, although is not without its complications, with rates of up to 10% for nonunion, 14% for reoperation and 10% for metatarsalgia. The aim of this study was to analyze the outcome of a double-stemmed silastic implant (Wright-Medical, Memphis, Tennessee, USA) for patients with end-stage HR.

Methods

We conducted a retrospective review of 108 consecutive implants in 76 patients, between January 2005 and December 2016, with a minimum follow-up of two years. The mean age of the patients at the time of surgery was 61.6 years (42 to 84). There were 104 females and four males. Clinical, radiological, patient reported outcome measures (PROMS) data, a visual analogue score (VAS) for pain, and satisfaction scores were collected.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 32 - 32
1 Apr 2013
Al-Maiyah M Rice P Schneider T
Full Access

Introduction

Hallux Rigidus affects 2–10% of population, usually treated with cheilectomy or arthrodesis, however, for the subclass of patients who refuse to undergo fusion, Arthroplasty is an alternative solution, it maintain some degree of motion and provide pain relief. Toefit; is one of the prostheses being used. It is a total joint replacement with polyethylene insert.

The aim of this study is to find clinical and radiological outcomes of Toefit arthroplasty.

Method

A prospective study. Ethical committee approval was obtained. Patient who have received Toefit Arthroplasty with at least 12 months follow-up and were willing to participate in the study were included. Patients were reviewed by independent surgeon. Questionnaires were completed followed by clinical examination. This followed by radiographic assessment. Patients, who were willing to take part in the study but could not attend a clinical review, were invited to participate in telephone questionnaire. Pre and postoperative AOFAS scores were compared, patients' satisfaction and clinical and radiological outcome were assessed using descriptive statistics, t-test and survivalship analysis were done.


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1094 - 1098
1 Oct 2023
Jennison T Ukoumunne OC Lamb S Sharpe I Goldberg AJ

Aims. When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). Methods. A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure. Results. A total of 131 patients underwent fusion as a salvage procedure following TAA. Their mean age was 65.7 years (SD 10.6) and 73 (55.7%) were male. The mean follow-up was 47.5 months (SD 27.2). The mean time between TAA and fusion was 5.3 years (SD 2.7). Overall, 32 (24.4%) underwent reoperations other than revision and 29 (22.1%) failed. Of these 24 (18.3%) underwent revision of the fusion and five (3.8%) had a below-knee amputation. No patients underwent conversion to a further TAA. Failure usually occurred in the first three postoperative years with one-year survival of fusion being 96.0% (95% confidence interval (CI) 90.7 to 98.3) and three-year survival in 69 patients being 77.5% (95% CI 68.3 to 84.4). Conclusion. Salvage fusion after a failed TAA shows moderate rates of failure and reoperations. Nearly 25% of patients required revision within three years. This study is an extension of studies using the same methodology reporting the failure rates and risk factors for failure, which have recently been published, and also one reporting the outcome of revision TAA for a failed primary TAA, using the same methodology, which will shortly be published. Cite this article: Bone Joint J 2023;105-B(10):1094–1098


Bone & Joint Open
Vol. 5, Issue 9 | Pages 799 - 805
24 Sep 2024
Fletcher WR Collins T Fox A Pillai A

Aims. The Cartiva synthetic cartilage implant (SCI) entered mainstream use in the management of first metatarsophalangeal joint (MTPJ) arthritis following the positive results of large trials in 2016. Limited information is available on the longer-term outcomes of this implant within the literature, particularly when independent from the originator. This single-centre cohort study investigates the efficacy of the Cartiva SCI at up to five years. Methods. First MTPJ arthritis was radiologically graded according to the Hattrup and Johnson (HJ) classification. Preoperative and sequential postoperative patient-reported outcome measures (PROMs) were evaluated using the Manchester-Oxford Foot Questionnaire (MOXFQ), and the activities of daily living (ADL) sub-section of the Foot and Ankle Ability Measure (FAAM). Results. Patients were followed up for a mean of 66 months (SD 7.1). Of an initial 66 cases, 16 did not return PROM questionnaires. A total of six failures were noted, with survival of 82%. Overall, significant improvement in both objective scores (MOXFQ and FAAM ADL) was maintained versus preoperatively: 18.2 versus 58.0 (p > 0.001) and 86.2 versus 41.1 (p > 0.001), respectively. The improvement was noted to be less pronounced in males. Subjective scores had deteriorated since early follow-up, with an interval decrease in patient satisfaction from 89% to 68%. Furthermore, a subset of cases demonstrated clinically important interval deterioration in objective scores. However, no specific patient factors were found to be associated with outcomes following analysis. Conclusion. This study represents the longest-term independent follow-up in the literature. It shows reassuring mid-term efficacy of the Cartiva SCI with better-than-expected survival. However, deterioration in scores for a subset of patients and lower satisfaction may predict ongoing failure in this group of patients. Additionally, males were noted to have a lower degree of improvement in scores than females. As such, ongoing observation of the SCI to assess durability and survivability, and identify predictive factors, is key to improving patient selection. Cite this article: Bone Jt Open 2024;5(9):799–805


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 3 - 3
4 Jun 2024
Jamjoom B Siddiqui B Salem H Raglan M Dhar S
Full Access

Background. The literature on the outcome of revision total ankle arthroplasty (TAA) remains limited. We aim to report the clinical and radiological outcomes of revision TAA at a high-volume centre in the UK. Methods. Retrospective review of 28 patients that underwent 29 revision TAA procedures using INBONE II prosthesis. Demographic, radiological, and patient reported outcome measures data were analysed. Results. The mean (range) duration from primary TAA to revision was 87.5 (16–223) months. The main indication for the revision was aseptic loosening of the primary TAA (82.8%). Additional procedures were required in 75.9% of patients. At mean (range) follow-up of 40 (24- 60) months, the infection, re-operation, and implant survival rates were 6.9%, 6.9% and 96.5% respectively. A significant postoperative improvement in the component alignment radiographic measures was observed. Osteolysis, subsidence, loosening and heterotopic ossification rates were comparable to other reports and did not influence the clinical outcome. A significant improvement was observed in the MOXFQ (all domains) and the EQ-5D (three domains) at 24 months postoperatively. Conclusions. Revision TAA using INBONE II was associated with good short-term survival and improvement in the postoperative scores at 2 years. Maintenance of the postoperatively improved alignment was documented at follow up. The relatively high survival rate in this series supports the notion that revision TAA is a satisfactory option for failed primary TAA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 8 - 8
8 May 2024
Humphrey J Kanthasamy S Coughlin P Coll A Robinson A
Full Access

Aim. This retrospective case series reports the reoperation, major amputation, survival rates and mobility status in diabetic patients who underwent a trans-metatarsal amputation (TMA) managed within a multi-disciplinary diabetic foot care service. Methods and patients. Forty-one consecutive patients (37 men, 4 women) underwent a TMA between January 2008 to December 2017. They were retrospectively reviewed. The mean age at the time of surgery was 63 years (range 39 – 92). Results. Eighty-eight per cent (36/41) of the patients were followed-up. Four (11%) of the 36 patients required reoperation, including three major amputations (8%). All the patients requiring a reoperation were vasculopaths. The four-year patient survival rate following a TMA was 69% (25/36). Ninety-six per cent (21/22) of the surviving patients not requiring revision to a major amputation were fully mobile in bespoke orthoses, of whom a third required a stick. Conclusion. This study shows that transmetatarsal amputation in patients with diabetes, managed in a multi-disciplinary diabetic foot care service, is effective for limb salvage


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1099 - 1107
1 Oct 2023
Henry JK Shaffrey I Wishman M Palma Munita J Zhu J Cody E Ellis S Deland J Demetracopoulos C

Aims. The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. Methods. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes. Results. There were 168 patients (171 ankles) included with a mean follow-up of 2.81 years (2 to 4.6) and mean age of 63.0 years (SD 9.4). Of the ten ankles with implant failure (5.8%), six had loosening of the tibial component. In the remaining four failed implants, one was due to periprosthetic joint infection (PJI), one was due to loosening of the talar component, and two were due to loosening of both the tibial and talar components. Seven patients underwent reoperation: irrigation and debridement for superficial infection (n = 4); bone grafting for cysts (n = 2); and open reduction internal fixation (n = 1). Asymptomatic peri-implant lucency/subsidence occurred in 20.1% of ankles, with the majority involving the tibial component (n = 25). There were statistically significant improvements in PROMs in all domains. Conclusion. Short-term results of this implant demonstrate early survival comparable to the reported survivorship of similar low-profile, non-stemmed implants. Radiological lucency occurred more commonly at the tibial component, and revisions occurred primarily due to loosening of the tibial component. Further research is needed to evaluate longer-term survivorship. Cite this article: Bone Joint J 2023;105-B(10):1099–1107


The Bone & Joint Journal
Vol. 103-B, Issue 4 | Pages 696 - 703
1 Apr 2021
Clough TM Ring J

Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17), wound healing (13.6%, n = 16), and superficial infection (12.7%, n = 15). The commonest reason for revision was aseptic loosening. No patients in our study were revised for deep infection. Conclusion. Our results show that Zenith survival rates are comparable with those in the literature for other implants and in the National Joint Registry (NJR). Overall patient satisfaction was high as were functional outcomes. However, the data highlight potential complications associated with this surgery. The authors believe that these figures support ankle arthroplasty as an option in the treatment of ankle arthritis. Cite this article: Bone Joint J 2021;103-B(4):696–703


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 11 - 11
8 May 2024
Daniels T
Full Access

Introduction/Purpose. A randomized clinical trial of first MTP joint hemiarthroplasty with a synthetic cartilage implant demonstrated equivalent pain, function and safety outcomes to first MTP joint arthrodesis at 2 years. Recognizing that many hemiarthroplasty and total toe implants have initially good results that deteriorate over time, the purpose of this study was to prospectively assess the safety and efficacy outcomes for the synthetic cartilage implant population and to determine if the excellent outcomes were maintained at >5 years. Methods. One hundred nineteen patients were evaluated at 5+ years; 23 could not be reached for follow-up, but implant status was available for 7 of these subjects. Patients completed a pain visual analogue scale (VAS) and Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) scores, preoperatively and at 2, 6, 12, 26, 52, 104 and 260 weeks postoperatively. Minimal clinically important differences are: ≥30% difference for pain VAS, 9 points for FAAM Sports, and 8 points for FAAM ADL. Great toe active dorsiflexion, weight-bearing radiographs, secondary procedures, and safety parameters were evaluated. Results. Of 119 patients available at mean 5.8 years follow-up (SD ±0.7; range: 4.4–8.0), 9 underwent implant removal and conversion to fusion in years 2–5, leaving 106 patients. The implant survival rate was 92.4% at 5.8 years. Pain and function outcomes at 5.8 years were similar to those at 2 years. VAS Pain, FAAM Sports, ADL Scores were maintained or improved at 5.8 years. No evidence of avascular necrosis, device migration or fragmentation was observed. There were no unanticipated safety events through 5.8 years. Ninety-three (93%) percent would have the procedure again. Conclusion. The synthetic cartilage hemiarthroplasty implant continues to demonstrate safety and efficacy for the treatment of advanced first MTP joint osteoarthritis with evidence of therapeutic effect and acceptable safety profile at 5.8 years


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 20 - 20
8 May 2024
Eyre-Brook A Ring J Gadd R Davies H Chadwick C Davies M Blundell C
Full Access

Introduction. Ankle fractures in the elderly are an increasing problem with our aging population. Options for treatment include non-operative and operative with a range of techniques available. Failure of treatment can lead to significant complications, morbidity and poor function. We compared the outcomes of two operative techniques, intramedullary hindfoot nailing (IMN) and fibular-pro-tibia fixation (FPT). This is the largest analysis of these techniques and there are no comparative studies published. Method. We retrospectively reviewed patients over the age of 60 with ankle fractures who were treated operatively between 2012 and 2017. We identified 1417 cases, including 27 patients treated with IMN and 41 treated with FPT. Age, sex, co-morbidities and injury pattern were collected. Primary outcome was re-operation rate. Secondary outcomes included other complications, length of stay and functional status. Results. The IMN group had a higher average co-morbidity score compared with the FPT group (estimated 10-year survival, 21% vs 53%, p=0.03). Re-operation rate was higher in the IMN group compared with FPT (12 v 1, p< 0.0001). There were more complications in the IMN group compared with the FPT group (23 v 11, p< 0.0001). Length of stay was longer in the IMN group (17 v 29 days, p=0.02). Mobility tended to return to baseline in the FPT patients but decreased in the IMN patients. Conclusion. Outcomes were worse in the IMN group compared with the FPT group in terms of re-operation, complications and length of stay. However, the IMN group tended to have increased comorbidities and poorer soft tissues. We believe that both techniques have a role in the management of elderly ankle fractures, but patient selection is key. We suggest FPT should be the first-choice technique when soft tissues permit. We discuss the indications, risks and benefits of each method based on our experience and literature review


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_12 | Pages 6 - 6
10 Jun 2024
Bethel J Najefi A Davies M Gosney E Patel K Ahluwalia R
Full Access

Introduction. Hindfoot intramedullary nail fixation (HFN) or fibula pro-tibial screw fixation (PTS) are surgical options for ankle fractures in patients with multiple co-morbidities; we compared their outcomes. Methods. A retrospective review of 135 patients who underwent HFN fixation (87 patients) or PTS fixation (48 patients) for ankle fractures (AO/OTA A/B/C) from 5 major trauma centres. Patient demographic data, co-morbidities, Charlson Co-morbidity Index Score (CCIS), weight-bearing, and post-operative complications were recorded. Radiographs were assessed for non-union and anatomical reduction. Results. HFN estimated 10-year survival was 27±31% and was 48±37% for PTS (p<0.001). Average time to full weightbearing (FWB) in the HFN group was 1.7±3.3 weeks compared to 7.8±3.8 weeks in the PTS group (p<0.001). Despite this, HFN fixation carried a greater VTE risk (p=0.02). HFN accompanied by joint preparation had greater risk of infection (p=0.01), metalwork failure (p=0.02) and wound breakdown (p=0.01). The overall complication rate in diabetic patients was 56%, but 76% in HFN patients. In the HFN group 17 (20%) patients died at 1 year. Patients with open fractures(p=0.01), dementia (p<0.05), and a higher CCIS (p=0.04) were more likely to die after HFN surgery. Age and co-morbidity matched data showed a higher rate of complications and mortality in those above 75 years fixed with a HFN, irrespective of CCIS. In those between 60–75 years, there was a greater risk of superficial infection and mortality after HFN, irrespective of CCIS. These complications were not seen after PTS. Conclusion. HFN carries a greater risk of superficial infections, VTE and mortality compared to PTS, independent of age and CCIS. Diabetes leads to a greater comparative risk of deep infections, wound breakdown and non-union in HFN. Alternative methods of fixation (e.g. PTS) should be considered before HFN. HFN may be suitable in selective indications where other methods are not appropriate


The Bone & Joint Journal
Vol. 104-B, Issue 4 | Pages 472 - 478
1 Apr 2022
Maccario C Paoli T Romano F D’Ambrosi R Indino C Federico UG

Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At five-year follow-up, statistically significant improvements (p < 0.001) were found in the mean American Orthopaedic Foot & Ankle Society Ankle Hindfoot Score (from 33.8 (SD 14.3) to 86.1 (SD 8.8)), visual analogue scale for pain (from 8.5 (SD 1.7) to 1.5 (SD 1.2)), Short Form-12 Physical and Mental Component Scores (from 29.9 (SD 6.7) and 43.3 (SD 8.6) to 47.3 (SD 7.5) and 52.2 (SD 8.0), respectively), and mean ankle dorsiflexion and plantarflexion (from 6.2° (SD 5.5°) and 9.6° (SD 5.8°) to 23.9° (SD 7.7°) and 16.9° (SD 7.2°), respectively). Radiologically, the implants maintained neutral alignment without subsidence. Tibial or talar radiolucency was found in eight patients, but none of these patients was symptomatic. At five-year follow up, 97.7% of implants (95% confidence interval 91.2 to 99.4) were free from revision or removal with 84 implants at risk. We recorded two cases (2.3%) of failure for septic loosening. Conclusion. Transfibular TAA is safe and effective with a high survival rate at mid-term follow-up and satisfactory clinical and radiological results. Further studies are required to determine the long-term performance of these implants. Cite this article: Bone Joint J 2022;104-B(4):472–478


The Bone & Joint Journal
Vol. 101-B, Issue 1 | Pages 47 - 54
1 Jan 2019
Clough T Bodo K Majeed H Davenport J Karski M

Aims. We report the long-term clinical and radiological outcomes of a consecutive series of 200 total ankle arthroplasties (TAAs, 184 patients) at a single centre using the Scandinavian Total Ankle Replacement (STAR) implants. Patients and Methods. Between November 1993 and February 2000, 200 consecutive STAR prostheses were implanted in 184 patients by a single surgeon. Demographic and clinical data were collected prospectively and the last available status was recorded for further survival analysis. All surviving patients underwent regular clinical and radiological review. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot scoring system. The principal endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan–Meier survival curves were generated with 95% confidence intervals and the rate of failure calculated for each year. Results. A total of 84 patients (87 ankles) were alive by the end of this study. Of the surviving 84 patients (87 ankles; rheumatoid arthritis (RA), n = 40; OA, n = 47), 45 were women and 39 were men, with a mean age of 54 years (18 to 72 years) at the time of surgery. A total of 32 implants failed (16%), requiring revision surgery. The mean time to revision was 80 months (2 to 257). The implant survival at 15.8 years, using revision as an endpoint, was 76.16% (95% confidence interval (CI) 64.41 to 87.91). We found a steady but low decrease in survival over the study period. The mean AOFAS score improved from 28 (10 to 52) preoperatively to 61 (20 to 90) at long-term follow-up. Conclusion. STAR prostheses in the United Kingdom have now been largely superseded by newer design TAAs, potentially with improved characteristics and surgical techniques. The long-term survivorship for the STAR prosthesis can provide a benchmark for these later designs of ankle arthroplasty