Aims. Implant failure has become more common as the number of primary total ankle arthroplasties (TAAs) performed has increased. Although revision arthroplasty has gained attention for functional preservation, the long-term results remain unclear. This study aimed to assess the long-term outcomes of revision TAA using a mobile-bearing prosthesis in a considerably large cohort; the risk factors for failure were also determined. Methods. This single-centre retrospective cohort study included 116 patients (117 ankles) who underwent revision TAA for failed primary TAA between July 2000 and March 2010. Survival analysis and risk factor assessment were performed, and clinical performance and patient satisfaction were evaluated preoperatively and at last follow-up. Results. The mean duration from initial revision TAA to last follow-up was 15.0 years (SD 3.0; 11.2 to 20.5). The cumulative
Aim. This retrospective case series reports the reoperation, major amputation,
Background. The literature on the outcome of revision total ankle arthroplasty (TAA) remains limited. We aim to report the clinical and radiological outcomes of revision TAA at a high-volume centre in the UK. Methods. Retrospective review of 28 patients that underwent 29 revision TAA procedures using INBONE II prosthesis. Demographic, radiological, and patient reported outcome measures data were analysed. Results. The mean (range) duration from primary TAA to revision was 87.5 (16–223) months. The main indication for the revision was aseptic loosening of the primary TAA (82.8%). Additional procedures were required in 75.9% of patients. At mean (range) follow-up of 40 (24- 60) months, the infection, re-operation, and implant
Aims. Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. Methods. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Results. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Conclusion. Ankle arthroplasties in the UK have a five-year
Introduction/Purpose. A randomized clinical trial of first MTP joint hemiarthroplasty with a synthetic cartilage implant demonstrated equivalent pain, function and safety outcomes to first MTP joint arthrodesis at 2 years. Recognizing that many hemiarthroplasty and total toe implants have initially good results that deteriorate over time, the purpose of this study was to prospectively assess the safety and efficacy outcomes for the synthetic cartilage implant population and to determine if the excellent outcomes were maintained at >5 years. Methods. One hundred nineteen patients were evaluated at 5+ years; 23 could not be reached for follow-up, but implant status was available for 7 of these subjects. Patients completed a pain visual analogue scale (VAS) and Foot and Ankle Ability Measure (FAAM) Sports and Activities of Daily Living (ADL) scores, preoperatively and at 2, 6, 12, 26, 52, 104 and 260 weeks postoperatively. Minimal clinically important differences are: ≥30% difference for pain VAS, 9 points for FAAM Sports, and 8 points for FAAM ADL. Great toe active dorsiflexion, weight-bearing radiographs, secondary procedures, and safety parameters were evaluated. Results. Of 119 patients available at mean 5.8 years follow-up (SD ±0.7; range: 4.4–8.0), 9 underwent implant removal and conversion to fusion in years 2–5, leaving 106 patients. The implant
Aims. This study reports updates the previously published two-year clinical, functional, and radiological results of a group of patients who underwent transfibular total ankle arthroplasty (TAA), with follow-up extended to a minimum of five years. Methods. We prospectively evaluated 89 patients who underwent transfibular TAA for end-stage osteoarthritis. Patients’ clinical and radiological examinations were collected pre- and postoperatively at six months and then annually for up to five years of follow-up. Three patients were lost at the final follow-up with a total of 86 patients at the final follow-up. Results. A total of 86 patients were evaluated at a mean follow-up of 65.4 months (60 to 90). At five-year follow-up, statistically significant improvements (p < 0.001) were found in the mean American Orthopaedic Foot & Ankle Society Ankle Hindfoot Score (from 33.8 (SD 14.3) to 86.1 (SD 8.8)), visual analogue scale for pain (from 8.5 (SD 1.7) to 1.5 (SD 1.2)), Short Form-12 Physical and Mental Component Scores (from 29.9 (SD 6.7) and 43.3 (SD 8.6) to 47.3 (SD 7.5) and 52.2 (SD 8.0), respectively), and mean ankle dorsiflexion and plantarflexion (from 6.2° (SD 5.5°) and 9.6° (SD 5.8°) to 23.9° (SD 7.7°) and 16.9° (SD 7.2°), respectively). Radiologically, the implants maintained neutral alignment without subsidence. Tibial or talar radiolucency was found in eight patients, but none of these patients was symptomatic. At five-year follow up, 97.7% of implants (95% confidence interval 91.2 to 99.4) were free from revision or removal with 84 implants at risk. We recorded two cases (2.3%) of failure for septic loosening. Conclusion. Transfibular TAA is safe and effective with a high
Aims. We report the medium-term outcomes of a consecutive series of 118 Zenith total ankle arthroplasties (TAAs) from a single, non-designer centre. Methods. Between December 2010 and May 2016, 118 consecutive Zenith prostheses were implanted in 114 patients. Demographic, clinical, and patient-reported outcome measures (PROMs) data were collected. The endpoint of the study was failure of the implant requiring revision of one or all of the components. Kaplan-Meier survival curves were generated with 95% confidence intervals (CIs) and the rate of failure calculated for each year. Results. Eight patients (ten ankles) died during follow-up, but none required revision. Of the surviving 106 patients (108 ankles: rheumatoid arthritis (RA), n = 15; osteoarthritis (OA), n = 93), 38 were women and 68 were men, with a mean age of 68.2 years (48 to 86) at the time of surgery. Mean follow-up was 5.1 years (2.1 to 9.0). A total of ten implants failed (8.5%), thus requiring revision. The implant survival at seven years, using revision as an endpoint, was 88.2% (95% CI 100% to 72.9%). There was a mean improvement in Manchester-Oxford Foot and Ankle Questionnaire (MOXFQ) from 85.0 to 32.8 and visual analogue scale (VAS) scores from 7.0 to 3.2, and overall satisfaction was 89%. The three commonest complications were malleolar fracture (14.4%, n = 17), wound healing (13.6%, n = 16), and superficial infection (12.7%, n = 15). The commonest reason for revision was aseptic loosening. No patients in our study were revised for deep infection. Conclusion. Our results show that Zenith
When a total ankle arthroplasty (TAA) fails, it can be converted to a fusion or a revision arthroplasty. Despite the increasing numbers of TAAs being undertaken, there is little information in the literature about the management of patients undergoing fusion following a failed TAA. The primary aim of this study was to analyze the survival of fusions following a failed TAA using a large dataset from the National Joint Registry (NJR). A data linkage study combined NJR and NHS Digital data. Failure of a TAA was defined as a fusion, revision to a further TAA, or amputation. Life tables and Kaplan-Meier graphs were used to record survival. Cox proportional hazards regression models were fitted to compare the rates of failure.Aims
Methods
Aims. The number of revision total ankle arthroplasties (TAAs) which are undertaken is increasing. Few studies have reported the survival after this procedure. The primary aim of this study was to analyze the survival of revision ankle arthroplasties using large datasets. Secondary aims were to summarize the demographics of the patients, the indications for revision TAA, further operations, and predictors of survival. Methods. The study combined data from the National Joint Registry and NHS Digital to report the survival of revision TAA. We have previously reported the failure rates and risk factors for failure after TAA, and the outcome of fusion after a failed TAA, using the same methodology. Survival was assessed using life tables and Kaplan Meier graphs. Cox proportional hazards regression models were fitted to compare failure rates. Results. A total of 228 patients underwent revision TAA. The mean follow-up was 2.6 years (SD 2.0). The mean time between the initial procedure and revision was 2.3 years (SD 1.8). The most commonly used implant was the Inbone which was used in 81 patients. A total of 29 (12.7%) failed; nine (3.9%) patients underwent a further revision, 19 (8.3%) underwent a fusion, and one (0.4%) had an amputation. The
The Vantage Total Ankle System is a fourth-generation low-profile fixed-bearing implant that has been available since 2016. We aimed to describe our early experience with this implant. This is a single-centre retrospective review of patients who underwent primary total ankle arthroplasty (TAA) with a Vantage implant between November 2017 and February 2020, with a minimum of two years’ follow-up. Four surgeons contributed patients. The primary outcome was reoperation and revision rate of the Vantage implant at two years. Secondary outcomes included radiological alignment, peri-implant complications, and pre- and postoperative patient-reported outcomes.Aims
Methods
Calcaneal osteomyelitis remains a difficult condition to treat with high rates of recurrence and below-knee amputation, particularly in the presence of severe soft-tissue destruction. This study assesses the outcomes of single-stage orthoplastic surgical treatment of calcaneal osteomyelitis with large soft-tissue defects. A retrospective review was performed of all patients who underwent combined single-stage orthoplastic treatment of calcaneal osteomyelitis (01/2008 to 12/2022). Primary outcome measures were osteomyelitis recurrence and below-knee amputation (BKA). Secondary outcome measures included flap failure, operating time, complications, and length of stay.Aims
Methods
This scoping review aims to identify patient-related factors associated with a poorer outcome following total ankle arthroplasty (TAA). A scoping review was performed using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A computer-based literature search was performed in PubMed, Embase, Cochrane trials, and Web of Science. Two reviewers independently performed title/abstract and full-text screening according to predetermined selection criteria. English-language original research studies reporting patient-related factors associated with a poorer outcome following TAA were included. Outcomes were defined as patient-reported outcome measures (PROMs), perioperative complications, and failure.Aims
Methods
Aim. To examine the mid-term survival, clinical and patient reported outcomes of the silastic 1. st. metatarsophalangeal joint replacement for the treatment of end stage hallux rigidus. Methods. We reviewed 83 consecutive silastic arthroplasties performed in 79 patients for end stage hallux rigidus. There were 3 men and 76 women; mean age 63 years (range 45–78 years). No patient was lost to follow up. Average follow-up was 5.3 years (1.1–11.3 years). The EQ 5D–5L Health index, Manchester-Oxford Foot Questionnaire (MOXFQ), visual analogue scale (VAS) of pain and overall satisfaction rate (Likert scale) were collected for patient reported outcomes. Results. 2 patients required revision; 1 for early infection (2 months) and 1 for stem breakage (10 years 1 month). 5 patients reported lateral metatarsalgia, 2 patients reported neuropathic pain, 6 patients developed superficial infection which fully responded to oral antibiotics, and 1 patient developed interphalangeal joint pain. 2 patients died in the cohort. Pre-operative mean MOXFQ was 44, mean EQ5D Index was 0.564 and VAS was 6.97. At mean follow-up of 5.3 years, the mean MOXFQ was 12.7 (0–57), the mean EQ5D Index was 0.851 (−0.02–1) and the mean VAS was 1.67 (0–8). The mean range of motion was 35° (30° dorsiflexion and 5° plantarflexion). The overall satisfaction rate was 90.2%. The implant
We present the outcomes in 38 consecutive patients who had total ankle replacement using the Ankle Evolution System with a minimum follow-up of four years. Pain and function were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score and regular standardised anteroposterior and lateral weight-bearing radiographs were obtained. Patient satisfaction and complications were recorded and the survival of the implants was demonstrated by the Kaplan-Meier method. The mean follow-up was for 57.8 months (48 to 80). The cumulative
We present a review of 97 consecutive BioPro. ®. metallic hemiarthroplasties performed in 80 patients for end-stage hallux rigidus, with a minimum of five years follow-up. The mean age of the cohort was 55 (22 to 74) years. No patient was lost to follow-up. There were 15 revisions performed, one for infection, two for osteolysis, and 12 for pain. The all cause
In our unit, we adopt a two-stage surgical reconstruction approach using internal fixation for the management of infected Charcot foot deformity. We evaluate our experience with this functional limb salvage method. We conducted a retrospective analysis of prospectively collected data of all patients with infected Charcot foot deformity who underwent two-stage reconstruction with internal fixation between July 2011 and November 2019, with a minimum of 12 months’ follow-up.Aims
Methods
This is a multicentre, non-inventor, prospective observational study of 503 INFINITY fixed bearing total ankle arthroplasties (TAAs). We report our early experience, complications, and radiological and functional outcomes. Patients were recruited from 11 specialist centres between June 2016 and November 2019. Demographic, radiological, and functional outcome data (Ankle Osteoarthritis Scale, Manchester Oxford Questionnaire, and EuroQol five-dimension five-level score) were collected preoperatively, at six months, one year, and two years. The Canadian Orthopaedic Foot and Ankle Society (COFAS) grading system was used to stratify deformity. Early and late complications and reoperations were recorded as adverse events. Radiographs were assessed for lucencies, cysts, and/or subsidence.Aims
Methods
Introduction:. The role of total ankle replacements remains unproven within orthopaedic literature. We present a prospective series of patients who underwent a SALTO TAR (Tornier) between October 2006 and January 2014. Methods:. A cohort of 53 TAR (50 patients) were prospectively followed up and assessed clinically, radiologically and asked to complete FAOS, VAS and Modified AOFAS scores. Four patients had bilateral procedures. The mean age was 71 years old (range 42–92). The mean follow up was 55 months (range 6–92). Nineteen TARs (19 patients) have a follow up of more than 60 months. Results:. Our
Introduction. There are a number of options available for surgical management of hallux rigidus. Ceramic implants of the first metatarsophalangeal joint (MTPJ) have been available for years; however there are no published long-term results existing. Methods. We performed a retrospective review of all consecutive first MTPJ replacements carried out for later stage hallux rigidus using second generation MOJE ceramic implant with press-fit design. Two specialised foot and ankle surgeons performed these operations at a tertiary referral centre. Patient underwent regular follow ups including clinical review, functional scoring (AOFAS and FFI) and assessment of radiographs. Kaplan Meyer Survival analysis was performed. Results. Our study included 31 prostheses in 24 female patients. Average age at operation was 55.3 years and average follow up time was 80 months. No patients were lost until follow up. Complications included one case of superficial infection and five cases of revision, reasons being fracture of the prostheses (1), unexplained pain (1), subluxation (1) and loosening/sinkage of the implant (2). Prosthesis
To assess the effect of age on clinical outcome and revision rates in patients who underwent total ankle arthroplasty (TAA) for end-stage ankle osteoarthritis (OA). A consecutive series of 811 ankles (789 patients) that underwent TAA between May 2003 and December 2013 were enrolled. The influence of age on clinical outcome, including the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score, and pain according to the visual analogue scale (VAS) was assessed. In addition, the risk for revision surgery that includes soft tissue procedures, periarticular arthrodeses/osteotomies, ankle joint debridement, and/or inlay exchange (defined as minor revision), as well as the risk for revision surgery necessitating the exchange of any of the metallic components or removal of implant followed by ankle/hindfoot fusion (defined as major revision) was calculated.Aims
Methods