Controversy surrounds the management of displaced
three- and four-part fractures of the proximal humerus. The percutaneous
Resch technique of stabilisation involves minimal soft-tissue dissection
and a reduced risk of stiffness and avascular necrosis. However,
it requires a second operation to remove Kirschner wires and the
humeral block. We describe a modification of this technique that
dispenses with the need for this second operation and relies on
a sequential pattern of screw placement. We report the outcome of
32 three- or four-part fractures of the proximal humerus treated
in this way at a mean follow-up of 3.8 years (2 to 8)). There were
14 men and 18 women with a mean age of 56 years (28 to 83). At final
follow-up the mean Oxford shoulder scores were 38 (31 to 44) and
39 (31 to 42), and the mean Constant scores were 79 (65 to 92) and
72 (70 to 80) for three- and four-part fractures, respectively. We
further analysed the results in patients aged <
60 years with
high-energy fractures and those aged ≥ 60 years with osteoporotic
fractures. There were no cases of nonunion or avascular necrosis. The results were good and comparable to those previously reported
for the Resch technique and other means of fixation for proximal
humeral fractures. We would recommend this modification of the technique
for the treatment of displaced three-part and four-part fractures
in patients both younger and older than 60 years of age.
Aims. Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). Methods. A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable
Abstract. Reverse shoulder arthroplasty (RSA) is being increasingly used for complex, displaced fractures of the proximal humerus. The main goal of the current study was to evaluate the functional and radiographic results after primary RSA of three or four-part fractures of the proximal humerus in elderly patients. Between 2012 and 2020, 70 consecutive patients with a recent three- or four-part fracture of the proximal humerus were treated with an RSA. There were 41 women and 29 men, with a mean age of 76 years. The dominant arm was involved in 42 patients (60%). All surgeries were carried out within 21 days. Displaced
Objectives. The objective of this study was to perform a meta-analysis of all randomised controlled trials (RCTs) comparing surgical and non-surgical management of fractures of the proximal humerus, and to determine whether further analyses based on complexity of fracture, or the type of surgical intervention, produced disparate findings on patient outcomes. Methods. A systematic review of the literature was performed identifying all RCTs that compared surgical and non-surgical management of fractures of the proximal humerus. Meta-analysis of clinical outcomes was performed where possible. Subgroup analysis based on the type of fracture, and a sensitivity analysis based on the type of surgical intervention, were also performed. Results. Seven studies including 528 patients were included. The overall meta-analysis found that there was no difference in clinical outcomes. However, subgroup and sensitivity analyses found improved patient outcomes for more complex fractures managed surgically. Four-part fractures that underwent surgery had improved long-term health utility scores (mean difference, MD 95% CI 0.04 to 0.28; p = 0.007). They were also less likely to result in osteoarthritis, osteonecrosis and non/malunion (OR 7.38, 95% CI 1.97 to 27.60; p = 0.003). Another significant subgroup finding was that secondary surgery was more common for patients that underwent internal fixation compared with conservative management within the studies with predominantly
The surgical treatment of three- and four-part fractures of the proximal humerus in osteoporotic bone is difficult and there is no consensus as to which technique leads to the best outcome in elderly patients. Between 1998 and 2004 we treated 76 patients aged over 70 years with three- or four-part fractures by percutaneous reduction and internal fixation using the Humerusblock. A displacement of the tuberosity of >
5 mm and an angulation of >
30° of the head fragment were the indications for surgery. Of the patients 50 (51 fractures) were available for follow-up after a mean of 33.8 months (5.8 to 81). The absolute, age-related and side-related Constant scores were recorded. Of the 51 fractures, 46 (90.2%) healed primarily. Re-displacement of fragments or migration of Kirschner wires was seen in five cases. Necrosis of the humeral head developed in four patients. In three patients a secondary arthroplasty had to be performed, in two because of re-displacement and in one for necrosis of the head. There was one case of deep infection which required a further operation and one of delayed healing. The mean Constant score of the patients with a
Proximal humeral fractures occur frequently, with fixed angle locking plates often being used for their treatment. However, the failure rate of this fixation is high, ranging between 10 and 35%. Numerous variables are thought to affect the performance of the fixation used, including the length and configuration of screws used and the plate position. However, there is currently limited quantitative evidence to support concepts for optimal fixation. The variations in surgical techniques and human anatomy make biomechanical testing prohibitive for such investigations. Therefore, a finite element osteosynthesis test kit has been developed and validated - SystemFix. The aim of this study was to quantify the effect of variations in screw length, configuration and plate position on predicted failure risk of PHILOS plate fixation for unstable proximal humerus fractures using the test kit. Twenty-six low-density humerus models were selected and osteotomized to create a malreduced unstable
A reverse shoulder arthroplasty has become increasingly common for the treatment of proximal humerus fractures. A reverse shoulder arthroplasty is indicated especially in older and osteopenic individuals in whom the osteopenia, fracture type or comminution precludes fixation. However, there are many other ways to treat proximal humerus fractures and many of these are appropriate for different indications. Percutaneous pinning remains an option in certain surgical neck or valgus impacted proximal humerus fractures with minimal or no comminution at the medial calcar. In general, a fracture that is amenable to open reduction and fixation should be fixed. Open reduction and internal fixation should be the gold standard treatment for
Proximal humeral fractures are the third most common fracture among the elderly. Complications associated with fixation include screw perforation, varus collapse, and avascular necrosis of the humeral head. To address these challenges, various augmentation techniques to increase medial column support have been developed. There are currently no recent studies that definitively establish the superiority of augmented fixation over non-augmented implants in the surgical treatment of proximal humeral fractures. The aim of this systematic review and meta-analysis was to compare the outcomes of patients who underwent locking-plate fixation with cement augmentation or bone-graft augmentation versus those who underwent locking-plate fixation without augmentation for proximal humeral fractures. The search was carried out according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Articles involving patients with complex proximal humeral fractures treated using open reduction with locking-plate fixation, with or without augmentation, were considered. A meta-analysis of comparative studies comparing locking-plate fixation with cement augmentation or with bone-graft augmentation versus locking-plate fixation without augmentation was performed.Aims
Methods
Aims. Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Methods. Eight pairs of
Proximal humeral fractures account for approximately 4–5% of all fractures seen in the emergency departments. Of all shoulder injuries they account for aproximatelly 53%. In 1970 Neer published his classic study, in which he described a new method of classification, and gave recommendations for treatment. Neer recommended ORIF for
The aim of this study was to determine the biomechanical behavior of two different implants used in the fixation of proximal humerus fractures. The two implants in this study are specifically designed for the fixation of proximal humerus fractures and both utilize the concept of fixed angle locking screws. Bone densitometry was performed prior to fracture production and fixation. A reproducible
Open reduction and internal fixation was employed in the treatment of 25 severely displaced fractures and fracture-dislocations of the proximal humerus. Our aims were accurate reduction and stable fixation to allow early mobilisation and to achieve full functional recovery. In 15 fractures an AO T-plate was used and in 10 a bent semitubular plate was employed as a blade plate. Excellent or satisfactory results were obtained in all six patients with two-part fractures involving the surgical neck; in four of the five patients with
Introduction. We present a consecutive series of 19 patients with 22 intra-articular calcaneal fractures treated by percutaneous arthroscopic fixation (percutaneous arthroscopic calcaneal osteosynthesis “PACO”). Traditional open reduction and fixation regularly has significant wound complications. PACO has the advantage of direct visualization of the joint surface reduction with the benefit of minimal soft tissue trauma and wound complications. Methods. Between July 2010 & April 2012, 39 isolated closed intra-articular calcaneal fractures were admitted to St Mary's Hospital. All Sanders type 2 and type 3 fractures were included. Undisplaced fractures (13) were treated non-operatively and comminuted type 4 fractures (4) were treated with primary arthroscopic fusion. Surgery was performed on the next list with no delay for swelling. All patients had pre and post op CT scans. Patients were discharged in a temporary cast with routine follow up at 2, 6 and 12 weeks. Technique. Arthroscopy was performed in the lateral position with a 4.0mm arthroscope, using two sinus tarsi portals and a posterolateral portal. The fracture fragments were reduced percutaneously, held with wires before definitive fixation. Results. There were 10
Two-part surgical neck fractures, two-part greater tuberosity fractures and three- and four-part fractures of the proximal humerus represent a frequently encountered clinical problem. Many types of conservative treatments have been proposed, with a poor functional outcome, however; when the fracture fragments are displaced, surgery is required. Because the open reduction and the internal fixation disrupts soft tissue and increases the risk of avascular necrosis of the humeral head, closed or minimally open reduction and percutaneous pin fixation should represent an advantage. We report on 31 patients affected by fractures of the proximal humerus (n=6, two-part surgical neck fractures; n=5, with two-part greater tuberosity
Purpose: To present the results of the use of shoulder prosthesis in multifragmented displaced humeral head fractures. Material-methods: 19 patients with comminuted and severely displaced fractures of the upper humeral epiphysis were treated with shoulder hemiar-throplasty. Their age varied from40 to 81 years (av:71). Seven patients had severely displaced four-part fracture; eight patients had four- part fracture-dislocation and four patients,
Three and four part fractures of the proximal humerus can prove difficult to treat and results are generally poor. We used a Polarus Nail technique to treat seven consecutive patients who had sustained an isolated fracture to the proximal humerus. According to Neers classification, four patients had sustained a
Objectives and Material: The authors have evaluated 78 patients with fractures of the proximal humerus that have been interned in the Orthopedics’ Service at Hospital de Santa Maria since the 1st January of 1995 until the 31st December of 1999 with the objective of evaluating different factors influencing the final results and concluding to the best therapeutic conduct in the different cases. Method: The following parameters have been evaluated: sex, age, accident type (low/high energy), associated injuries, fracture’s classification, type of treatment and results achieved. The Constant score have been used for the functional evaluation. Due to reduced number of patients in each class a non-parametric test has been used – Qui-square test (X2). SPSS program has been used to run the calculations. Results: It has been verified that sixty four percent of the cases happened due to low energy accidents and the
Percutaneous fixation is a well recognised technique in the treatment of three-part and four-part fractures of the proximal humerus. Minimal fixation of these fractures do show good functional outcome and may further reduce the incidence of avascular complications. We report a preliminary series of 11 patients who underwent percutaneous minimal fixation of such complex humeral fractures using a new technique. 11 consecutive patients (7 with
Aim: The authors report a new ostheosinthesis device(Prysmatic Threeangular System P.T.S.) designed for the treatment of complex fractures of the proximal part of the humerus. Methods: From May 2005 to February 2006 we treated ten patients, four patients were female and six male. The average age was 45.1 years (max. 69, min. 27). Cases included nine fresh fractures and a malunion of
Introduction and purpose: The results of hemiarthroplasty for the treatment of complex proximal humerus fractures are controversial since there are wide variations across series. In what follows, we shall present our experience and results with the implants we use, with a minimum follow-up of one year. Materials and methods: 87 prostheses were revised (hemiartroplasty with cemented Neer II endoprosthesis) with a minimum follow-up of one year (1 to 10); 74 females and 13 males, 53 right and 34 left, with a mean age of 73.3 years (range: 51 – 82). Indications included