Introduction. This study aims to investigate the relationship between
Introduction. The main postoperative complications in fixation of ulna shaft fractures are non-union and implant irritation using currently recommended 3.5-mm locking compression plates. An alternative approach using a combination of two smaller plates in orthogonal configuration has been proposed. The aim of this study was to compare the biomechanical properties of a single 3.5-mm locking compression plate versus double plating using one 2.5-mm and one 2.0-mm mandible plate in a human ulna shaft fracture model. Method. Eight pairs human
Background. Patients with hand injuries frequently present to Emergency Departments. The ability of junior doctors to perform an accurate clinical assessment is crucial in initiating appropriate management. Objectives. To assess the adequacy of junior doctor hand examination skills and to establish whether further training and education is required. Methods. A double-centre study was conducted using an anonymous survey assessing hand examination completed by junior doctors (Foundation year 1 and Senior House Officer grades) working in Trauma & Orthopaedics or Emergency Departments. The survey covered all aspects of hand examination including assessment of: Flexor and Extensor tendons, Nerves (motor and sensory) and Vascular status. Surveys were marked against answers pre-agreed with a Consultant hand surgeon. Results. 32 doctors completed the survey. Tendons: 59% could accurately examine extensor digitorum, 41% extensor pollicis longus, 38% flexor digitorum profundus and 28% flexor digitorum superficialis. Nerves – Motor: 53% could accurately examine the radial nerve, 37% the
Neurological examination is essential in patients with upper limb injuries and should be clearly documented. We aimed to assess the quality and documentation of neurological examination performed for children presenting with upper limb fractures to the emergency department. Clinical notes of all children admitted with upper limb fractures over a three month period were reviewed. Documentation of initial neurological assessment was analysed and clinical suspicion of any nerve injury noted. In parallel, we conducted an anonymous survey of emergency doctors evaluating their upper limb neurological examination in children. The casenotes of 121 children with upper limb fractures were reviewed. 10 children (8%) had a nerve injury (median = 4,
Current knowledge regarding upper limb myotomes is based on historic papers. Recent advances in magnetic resonance imaging (MRI) and surgical exploration with intraoperative nerve stimulation now allow accurate identification of nerve root injuries in the brachial plexus. The aim of this study is to identify the myotome values of the upper limb associated with defined supraclvicular brachial plexus injuries. 57 patients with partial supraclavicular brachial plexus injuries were identified from the Scottish brachial plexus database. The average age was 28 years and most injuries secondary to motor cycle accidents or stabbings. The operative and MRI findings for each patient were checked to establish the root injuries and the muscle powers of the upper limb documented. The main patterns of injuries identified involved (C5,6), (C5,6,7), (C5,6,7,8) and (C8, T1). C5, 6 injuries were associated with loss of shoulder abduction, external rotation and elbow flexion. In 30% of the 16 cases showed some biceps action from the C7 root. C5,6,7 injuries showed a similar pattern of weakness with the additional loss of flexor carpi radialis and weakness but not total paralysis of triceps in 85% of cases. C5,6,7,8 injuries were characterised by loss of pectoralis major, lattisimus dorsi, triceps, wrist extension, finger extension and as well as weakness of the
Purpose. The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results to prior publications for both external fixation and internal fixation with volar locked plates. Methods. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (MAT and MAI) from 5/30/2013 to 12/29/2015 were identified and included in the study. Retrospective chart and radiograph review was performed on nineteen patients, eleven male and eight female, with mean age of 47.83 years (22–82). No patients were excluded from the study. Results. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49–129). Follow up radiographs showed average radial inclination of 20.5° (13.2°–25.5°), radial height of 10.7mm (7.5mm–14mm),
Summary. Practitioners should maintain a high suspicion of concurrent carpal fractures in patients who present with a distal radius fracture after a fall onto an outstretched hand, particularly if forearm rotation is involved. Introduction. Simultaneous scaphoid and distal radius fractures, and the importance of their identification, have been previously described in multiple reports. However, few studies have investigated the incidence of carpal fractures, in general, occurring concurrently with distal radius fractures after a common mechanism of wrist injury. The purpose of this study is to investigate the incidence and characteristics of carpal fractures occurring simultaneously with distal radius fractures after a fall onto an outstretched hand. We hope to determine whether different fall parameters, such as hand position and forearm rotation, influence the frequency of this injury. Methods. Baseline MRI scans and fluoroscopic images of the wrist were obtained for two sets of 24 fresh frozen cadaveric arms. All of the arms were transected 18 cm proximal to Lister's tubercle and then mounted at 80° of wrist extension and full pronation. In the first set of 24 arms, eight were mounted perpendicular to the MTS table top, eight were radially deviated 10–15°, and eight were
Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2),
We used interconnected porous calcium hydroxyapatite ceramic to bridge a rabbit
Background. The traditional Kocher approach for lateral elbow exposure is often complicated by injury to the posterior interosseous nerve (PIN) and the lateral
3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting. For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer. PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated radial head causing complex elbow deformity as a result of a severe skeletal dysplasia, and a preoperative model of a deficient proximal tibia as a result of a severe tibia fracture. The models materially influenced clinical decision making, surgical intervention planning and required equipment. In the case of forearm an articulating model was constructed allowing the site of impingement between radius and
Posterolateral rotatory instability (PLRI) is the most common type of elbow instability. It is caused by an insufficiency of the lateral ligamentous complex, which consists mainly of the radial collateral ligament (RCL) and the lateral
Reverse total shoulder arthroplasty (RTSA) provides a surgical alternative to conventional shoulder arthroplasty in the rotator cuff deficient shoulder. Short term data has shown consistent improvements in pain and function but higher complication and failure rates have also been reported. The aims of this study were to identify the early and late complications of RTSA, to establish the frequency of glenoid notching, and to assess the post-operative functional outcomes. 21 patients (22 joints) treated with RTSA at Glasgow Royal Infirmary (GRI) between April 2006 and October 2010 were retrospectively reviewed. Indications for surgery included cuff tear arthropathy, revision hemiarthroplasty and fracture malunion. Complication rates were obtained by analysis of follow up data from Bluespier and case notes. Glenoid notching was graded from x-rays by multiple observers using the Sirveaux classification. Outcome was assessed using the Oxford Shoulder Score (OSS) and range of motion (ROM). The complication rate associated with RTSA was 14.3%, effecting 3 patients. One dislocation and 1
Various authors have linked hypermobility at the trapeziometacarpal joint to future development of arthritis. When examining hypermobility, the anterior oblique ligament (AOL) and
Background. The treatment of olecranon fractures frequently involves the use of tension band fixation. Although associated with high union rates, this method has a high incidence of morbidity associated with soft tissue compromise and limitation of range of movement requiring frequent re-operation for removal of metal. Objectives. We describe the use of a simple jig to ensure intramedullary placement of longitudinal K-wires and compare the accuracy of placement of wires using this device with the traditional free hand method. Methods & Materials. 10 orthopaedic surgical trainees passed 2 longitudinal k wires into synthetic ulnae. This was done using the free hand method and then plastic jig. The ulnae were then sectioned to identify the position of the wires relative to the intramedullary canal. Results. Of the free hand wires, only 11 of 20 were found to be intramedullary versus 20 of 20 in the group passed using the jig. (p<0.001). The mean distance from the center of the
Our unit has pursued a policy of using donor nerves from the same limb for grafting. Nerves which have already been affected by the primary injury are selected where possible, thus avoiding any new sensory deficit. Methods. 36 of the 41 brachial plexus repairs were available for outcome data collected prospectively over 2 years. Over a nine year period, donor nerves used for the 41 brachial plexus repairs included the lateral cutaneous nerve of the forearm, superficial radial, medial cutaneous of the forearm,
Summary. Increased lateral ulnotrochlear joint space due to improper sizing in radial head arthroplasty may result in medial collateral ligament laxity, leading to increased osteophytes and arthritis. Introduction. Radial head (RH) arthroplasty is a common response to comminuted RH fractures. Typical complications include improper sizing, leading to changes in joint kinematics. Evidence of these changes should be visible through fluoroscopic images of affected joints. The two examined changes in this study are the ulnar deviation from distal radial translation (DRT), and the widening of the lateral ulnotrochlear joint space (LUT). Methods. Eight fresh-frozen cadaver arms were used. Initial images were taken with the native RH intact. The Kocher approach exposed the radiocapitellar (RC) joint capsule, preserving all ligaments. The RH was excised and Integra Katalyst CoCr (Plainsboro, NJ) telescoping, bipolar, RH inserted. Images were taken with implant sizings: −2mm, 0mm, +2mm, and +4mm, (from native) using 1mm washers preventing implant bipolarity. AP fluoroscopic images of the elbow were taken at full extension. Joint spaces were measured using image analysis, normalised using known radio-opaque lengths. Four LUT measurements were made, two medially and two laterally, and normalised by measuring the RH implant diameter. Each set (medial and lateral) were averaged together and the resulting value used for all comparisons. Images of distal ulnar deviation at the wrist were taken with the wrist in supination, the hand rotated medially. Measurements were from the distal medial radial tip to the distal lateral
To determine the pattern of mutations of the A total of 15 patients with clinical features of PPD were enrolled in this study. Genomic DNA was isolated and polymerase chain reaction performed to amplify the Objectives
Patients and Methods
There are various pin-in-plaster methods for treating fractures
of the distal radius. The purpose of this study is to introduce
a modified technique of ‘pin in plaster’. Fifty-four patients with fractures of the distal radius were
followed for one year post-operatively. Patients were excluded if
they had type B fractures according to AO classification, multiple
injuries or pathological fractures, and were treated more than seven
days after injury. Range of movement and functional results were
evaluated at three and six months and one and two years post-operatively.
Radiographic parameters including radial inclination, tilt, and
height, were measured pre- and post-operatively.Objectives
Methods