Advertisement for orthosearch.org.uk
Results 1 - 20 of 28
Results per page:

Introduction. This study aims to investigate the relationship between ulnar fixation and postoperative satisfaction among patients with distal radius fractures accompanied by ulna styloid fractures, with a particular focus on how sociodemographic factors influence outcomes. Method. A retrospective cohort study was conducted involving 120 patients aged 26-53 who underwent surgical treatment for distal radius fractures with concomitant ulna styloid fractures between January 2018 and December 2022. Patients were divided into two groups based on whether ulnar fixation was performed. Sociodemographic data, including age, gender, socioeconomic status, education level, and occupation, were collected. All patients underwent similar physical therapy protocols in the postoperative period, and no complications were observed in any patient. Postoperative satisfaction was assessed using the Patient-Rated Wrist Evaluation (PRWE) and the Disabilities of the Arm, Shoulder, and Hand (DASH) scores at 6 and 12 months post-surgery. Statistical analysis was conducted to evaluate the influence of ulnar fixation and sociodemographic factors on patient satisfaction. Result. Patients who underwent ulnar fixation (n=60) reported significantly higher satisfaction levels compared to those who did not (n=60), as evidenced by lower PRWE and DASH scores (p < 0.05). Age, gender, and socioeconomic status were significant predictors of postoperative satisfaction. Younger patients, females, and those with higher socioeconomic status exhibited greater improvements in functional outcomes and satisfaction. However, education level and occupation did not significantly influence satisfaction scores. Conclusion. Ulnar fixation in the surgical treatment of distal radius fractures accompanied by ulna styloid fractures is associated with improved postoperative satisfaction. Sociodemographic factors, particularly age, gender, and socioeconomic status, play a crucial role in patient-reported outcomes. Tailoring postoperative care to address these sociodemographic differences may enhance overall patient satisfaction and recovery


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 10 - 10
14 Nov 2024
Zderic I Kraus M Rossenberg LV Puls L Pastor T Gueorguiev B Richards G Pape HC Pastor T
Full Access

Introduction. The main postoperative complications in fixation of ulna shaft fractures are non-union and implant irritation using currently recommended 3.5-mm locking compression plates. An alternative approach using a combination of two smaller plates in orthogonal configuration has been proposed. The aim of this study was to compare the biomechanical properties of a single 3.5-mm locking compression plate versus double plating using one 2.5-mm and one 2.0-mm mandible plate in a human ulna shaft fracture model. Method. Eight pairs human ulnar specimens with a standardized 10-mm fracture gap were pairwise assigned for instrumentation with either a single 3.5-mm plate placed posteriorly, or for double plating using a 2.5-mm and a 2.0-mm mandible plate placed posteriorly under the flexor muscles and laterally under the extensor muscles. All constructs were initially non-destructively biomechanically tested in axial compression, torsion, and bending, which was followed by cyclic torsional loading to failure. Interfragmentary movements were monitored by means of optical motion tracking. Result. There were no significant differences between the two plating techniques for axial stiffness (p=0.335), torsional stiffness in supination (p=0.462), torsional stiffness in pronation (p=0.307), medio-lateral bending stiffness (p=0.522), and antero-posterior bending stiffness (p=0.143). During cyclic torsional loading over the first 3000 cycles, there were no significant differences between the two plating techniques for shear displacement across the fracture gap, p=0.324. The numbers of cycles until clinically relevant failure of 5° angular deformation were 1366±685 for double plating and 2024±958 for single plating, which was statistically non-significantly different, p>0.05. The constructs treated with both plating techniques failed due to bone breakage at the most distal screw. Conclusion. From a biomechanical perspective double plating of ulna shaft fractures using a 2.5-mm and a 2.0-mm locking mandible plate demonstrated equivalent fixation strength as conventional plating using a single 3.5-mm locking compression plate


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 63 - 63
1 Apr 2017
Al-Azzani W Hill C Passmore C Czepulkowski A Mahon A Logan A
Full Access

Background. Patients with hand injuries frequently present to Emergency Departments. The ability of junior doctors to perform an accurate clinical assessment is crucial in initiating appropriate management. Objectives. To assess the adequacy of junior doctor hand examination skills and to establish whether further training and education is required. Methods. A double-centre study was conducted using an anonymous survey assessing hand examination completed by junior doctors (Foundation year 1 and Senior House Officer grades) working in Trauma & Orthopaedics or Emergency Departments. The survey covered all aspects of hand examination including assessment of: Flexor and Extensor tendons, Nerves (motor and sensory) and Vascular status. Surveys were marked against answers pre-agreed with a Consultant hand surgeon. Results. 32 doctors completed the survey. Tendons: 59% could accurately examine extensor digitorum, 41% extensor pollicis longus, 38% flexor digitorum profundus and 28% flexor digitorum superficialis. Nerves – Motor: 53% could accurately examine the radial nerve, 37% the ulnar nerve, 22% the median nerve and 9% the anterior interosseous nerve. Nerves – Sensory: 88% could accurately examine the radial nerve, 81% the ulnar nerve, 84% the median nerve and 18.8% digital nerves. Vascular: 93% could describe 3 methods of assessing vascularity. Conclusions. Tendon and neurological aspects of hand clinical examination were poorly executed at junior doctor level in this pragmatic survey. This highlights the need for targeted education and training to improve the accuracy of junior doctor hand injury assessment and subsequent improving patient treatment and safety. Recommendations include dedicated hand examination teaching early in Orthopaedic/A&E placements and introduction of an illustrated Hand Trauma Examination Proforma. Level of evidence. III - Evidence from case, correlation, and comparative studies


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 59 - 59
1 Aug 2013
Marsh A Roberston J Boyle J Huntley J
Full Access

Neurological examination is essential in patients with upper limb injuries and should be clearly documented. We aimed to assess the quality and documentation of neurological examination performed for children presenting with upper limb fractures to the emergency department. Clinical notes of all children admitted with upper limb fractures over a three month period were reviewed. Documentation of initial neurological assessment was analysed and clinical suspicion of any nerve injury noted. In parallel, we conducted an anonymous survey of emergency doctors evaluating their upper limb neurological examination in children. The casenotes of 121 children with upper limb fractures were reviewed. 10 children (8%) had a nerve injury (median = 4, ulnar = 2, radial = 2, anterior interosseous = 2). Neurological examination was documented in 107 (88%) of patients. However, none of the nerve injuries were detected on initial examination. In patients with nerve injuries, 5 (50%) were documented as being ‘neurovascularly intact’, 2 (20%) as ‘CSM normal’, 1 (10%) as ‘moving fingers’ and 2 (20%) had no documented neurological examination. 30 emergency doctors completed the questionnaires (5 consultants, 9 registrars, 16 foundation doctors). All doctors stated that they routinely performed an upper limb neurological examination and assessed median, ulnar and radial nerves. However, 30% of doctors described incomplete examination of median nerve function, 30% inadequate ulnar nerve assessment and 50% incomplete radial nerve examination. In addition, 75% of doctors failed to identify the need for assessment of anterior interosseous nerve function. While emergency doctors recognise the importance of neurological assessment in children with upper limb injuries, it is often performed inadequately. This in part may be due to difficulties performing neurological examination in paediatric patients. As a result of this study, we have introduced local guidelines to assist neurological assessment in children


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 66 - 66
1 Aug 2013
Bell S Brown M Hems T
Full Access

Current knowledge regarding upper limb myotomes is based on historic papers. Recent advances in magnetic resonance imaging (MRI) and surgical exploration with intraoperative nerve stimulation now allow accurate identification of nerve root injuries in the brachial plexus. The aim of this study is to identify the myotome values of the upper limb associated with defined supraclvicular brachial plexus injuries. 57 patients with partial supraclavicular brachial plexus injuries were identified from the Scottish brachial plexus database. The average age was 28 years and most injuries secondary to motor cycle accidents or stabbings. The operative and MRI findings for each patient were checked to establish the root injuries and the muscle powers of the upper limb documented. The main patterns of injuries identified involved (C5,6), (C5,6,7), (C5,6,7,8) and (C8, T1). C5, 6 injuries were associated with loss of shoulder abduction, external rotation and elbow flexion. In 30% of the 16 cases showed some biceps action from the C7 root. C5,6,7 injuries showed a similar pattern of weakness with the additional loss of flexor carpi radialis and weakness but not total paralysis of triceps in 85% of cases. C5,6,7,8 injuries were characterised by loss of pectoralis major, lattisimus dorsi, triceps, wrist extension, finger extension and as well as weakness of the ulnar intrinsic muscles. We identified weakness of the flexor digitorum profundus to the ulnar sided digits in 83% of cases. T1 has a major input to innervation of flexors of the radial digits and thumb, as well as intrinsics. This is the largest study of myotome values in patients with surgically or radiologically confirmed injuries in the literature and presents information for general orthopaedic surgeons dealing with trauma patients for the differentiation of different patterns of brachial plexus injuries. In addition we have identified new anatomical relationships not previously described in upper limb myotomes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 54 - 54
1 Apr 2018
Coury J Huish E Ibrahim M Trzeciak M
Full Access

Purpose. The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results to prior publications for both external fixation and internal fixation with volar locked plates. Methods. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (MAT and MAI) from 5/30/2013 to 12/29/2015 were identified and included in the study. Retrospective chart and radiograph review was performed on nineteen patients, eleven male and eight female, with mean age of 47.83 years (22–82). No patients were excluded from the study. Results. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49–129). Follow up radiographs showed average radial inclination of 20.5° (13.2°–25.5°), radial height of 10.7mm (7.5mm–14mm), ulnar variance of −0.3mm (−2.1mm–3.1mm), and volar tilt of 7.9° (−3°–15°). One patient had intra-articular step off >2mm. Conclusion. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt. Type of Study/Level of Evidence. Therapeutic Retrospective Level IV


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 230 - 230
1 Jul 2014
Nicolescu R Ouellette E Clifford P Kam C Sawardeker P Latta L
Full Access

Summary. Practitioners should maintain a high suspicion of concurrent carpal fractures in patients who present with a distal radius fracture after a fall onto an outstretched hand, particularly if forearm rotation is involved. Introduction. Simultaneous scaphoid and distal radius fractures, and the importance of their identification, have been previously described in multiple reports. However, few studies have investigated the incidence of carpal fractures, in general, occurring concurrently with distal radius fractures after a common mechanism of wrist injury. The purpose of this study is to investigate the incidence and characteristics of carpal fractures occurring simultaneously with distal radius fractures after a fall onto an outstretched hand. We hope to determine whether different fall parameters, such as hand position and forearm rotation, influence the frequency of this injury. Methods. Baseline MRI scans and fluoroscopic images of the wrist were obtained for two sets of 24 fresh frozen cadaveric arms. All of the arms were transected 18 cm proximal to Lister's tubercle and then mounted at 80° of wrist extension and full pronation. In the first set of 24 arms, eight were mounted perpendicular to the MTS table top, eight were radially deviated 10–15°, and eight were ulnarly deviated 10–15°. In the second set of 24 arms, twelve underwent 5 N-m of external forearm rotation, with six of the arms perpendicular to the MTS table top and the other six ulnarly deviated 10–15°. The last twelve arms underwent 5 N-m of internal forearm rotation, with six of the arms perpendicular to the MTS table top and the other six radially deviated 10–15°. The arms were then loaded on an MTS machine and axially displaced 2.5 cm at a compression rate of 5 cm/sec. Post injury fluoroscopic images and MRI scans of the wrist were obtained and analyzed. The MRI scans were scrutinised by one of us (EAO) – a board certified orthopaedic surgeon. Results. All of the arms sustained a distal radius fracture. Post-stress MRI revealed that 17 (35%) of the wrists also sustained at least one carpal bone fracture. The most common carpal bone injured was the scaphoid, which was fractured in 15 of the 17 arms with concurrent carpal fractures, or 31% of the arms overall. Moreover, lunate fractures were present in 6 of the wrists, triquetral fractures in 4 of the wrists, capitate fractures in 3 of the wrists, and one hamate fracture was present. Of the 17 arms with concurrent fractures, 15 had been subjected to a rotational force during MTS testing. Discussion. The incidence of carpal fractures occurring simultaneously with distal radius fractures after a fall onto an outstretched hand comprised a substantial proportion of the arms examined. While the type of carpal fracture does not appear to correlate with a specific hand position, it is evident that forearm rotation is more likely to result in concomitant injury. Early wrist motion—now the standard of care—after immobilization of a patient with a distal radius fracture may result in non-union if a missed carpal fracture is also present


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 273 - 273
1 Jul 2014
Alizadehkhaiyat O Vishwanathan K Frostick S
Full Access

Summary Statement. Discovery system produced effective functional improvement in both primary and revision total elbow replacement. The incidence of major complications was in an acceptable range. Introduction. The search for the ideal elbow prosthesis continues as instability and loosening remain the prime reasons for total elbow replacement (TER) failure. The Discovery Elbow System (Biomet) is one of the latest generations of linked prosthesis and has been used in UK since 2003. We report outcome of TER using this system. Methods. A total of 100 TERs (75 primary, 25 revisions) were performed between 2003 and 2010. The main primary underlying pathologies for TER were advanced rheumatoid arthritis (N=58), osteoarthritis (N=35), acute fractures (N=7). There were 60 female and 40 male patients with an average age of 62 years. The outcome assessment included pain, patient satisfaction, Liverpool Elbow Score (LES), range of movement, and imaging during a mean follow-up period of 48.5 months. Major complications are also reported. Results. For the whole patient group (primary + revision), the LES was significantly (p<0.001) improved from 3.79+/−1.71 to 6.36+/−1.85There were significant improvements in elbow flexion from 100°+/−24 to 118°+17, supination from 38°+/−26 to 50°+/−25 and pronation from 48°+/−22 to 61°+/−21. Mean improvement in flexion-extension and pronation-supination arc was 20° and 25°, respectively. 64% of cases were completely pain-free and at the final follow-up (compared to 7% preoperatively). Only 6% of patients scored “Not Satisfied” at the final follow-up. LES improvement was significantly higher in the primary TER compared to revision TER (p<0.05). Imaging reviewed for 60 cases showed loosening in 4% of patients. Other main complications included deep infection (N=2), ulnar neuropathy (N=3), pre-prosthetic fracture (N=2), and prosthetic failure (N=1). Discussion. TER using the Discovery Elbow System is an effective arthroplasty in terms of functional improvement, pain relief and range of motion in both primary and revision patients. TER resulted in no/mild pain in 78% of cases. Patients undergoing Acclaim, Souter-Strathclyde, GSB III, and Coonrad-Morrey TER have been reported to have no/mild pain in 64%, 67%, 50–92% and 60–100% of cases, respectively. A 20° improvement in flexion-extension arc is comparable to that of Acclaim (23°), Souter-Strathclyde (15°), GSBIII (19–33°), and Coonrad-Morrey (17–26°) TER. An improvement of 25° in pronation-supination arc in our series is also comparable to that of 21–28° reported the Coonrad-Morrey and 27–33° for Discovery prostheses. An infection rate of 2% is lower than several other reports for GSB III TER (7–11%) and Coonrad-Morrey (6–8%). The incidence of persistent ulnar neuropathy (3%) was lower compared to GSBIII TER (11–14%), Coonrad-Morrey (12–26%), and Acclaim (8%)


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 11 | Pages 1606 - 1613
1 Nov 2010
Oshima S Ishikawa M Mochizuki Y Kobayashi T Yasunaga Y Ochi M

We used interconnected porous calcium hydroxyapatite ceramic to bridge a rabbit ulnar defect. Two weeks after inducing the defect we percutaneously injected rabbit bone marrow-derived mesenchymal stromal cells labelled with ferumoxide. The contribution of an external magnetic targeting system to attract these cells into the ceramic and their effect on subsequent bone formation were evaluated. This technique significantly facilitated the infiltration of ferumoxide-labelled cells into ceramic and significantly contributed to the enhancement of bone formation even in the chronic phase. As such, it is potentially of clinical use to treat fractures, bone defects, delayed union and nonunion


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 35 - 35
1 May 2017
Han F Lim J Lim C Tan B Shen L Kumar V
Full Access

Background. The traditional Kocher approach for lateral elbow exposure is often complicated by injury to the posterior interosseous nerve (PIN) and the lateral ulnar collateral ligamentous (LUCL). Kaplan approach is less commonly used, due to its known proximity to the PIN. Extensor Digitorum Communis (EDC) splitting approach allows possible wide surgical exposure and low risk of LUCL damage. The comparison of PIN injury during surgical dissection among these 3 common lateral approaches was not previously evaluated. We aim to determine the anatomical proximity of the PIN in these 3 common lateral elbow approaches and to define a safe zone of dissection for the surgical exposure. Methods. Cadaveric dissections of 9 pairs of fresh frozen adult upper extremities were performed using EDC splitting, Kaplan and Kocher approach to the radial head sequentially in a randomised order. The radial head and PIN were exposed. A mark was made on the radial head upon the initial exposure during dissection. Measurements from the marked point of the radial head to the PIN were made. Study has been approved by the ethics committee. Results. The EDC splitting approach is associated with a significantly lower chance of encountering the PIN along the entry of dissection to reach the radial head as compared to the Kaplan approach. The Kocher approach has a lower chance of encountering the PIN along the entry of dissection to reach the radial head as compared to both Kaplan and EDC splitting approach. Conclusions. The EDC splitting approach provides adequate exposure without injury to the lateral ligamentous complex nor need to elevate or retract the EDC and ECU muscle mass that could risk injuring the PIN. The Kaplan approach should be done by experienced surgeons who are familiar with the anatomy in this region, with extreme caution due to proximity of the point of entry to the PIN. Level of evidence. IV


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 19 - 19
1 Oct 2016
Griffin M Annan J Hamilton D Simpson A
Full Access

3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting. For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer. PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated radial head causing complex elbow deformity as a result of a severe skeletal dysplasia, and a preoperative model of a deficient proximal tibia as a result of a severe tibia fracture. The models materially influenced clinical decision making, surgical intervention planning and required equipment. In the case of forearm an articulating model was constructed allowing the site of impingement between radius and ulnar to be identified, an osteotomy was practiced on multiple models allowing elimination of the block to supination. This has not previously been described in literature. The acetabulum model allowed pre-contouring of a posterior column plate which was then sterilised and eliminated a time consuming intraoperative step. While once specialist and expensive, in house 3D printing is now economically viable and a helpful tool in the management of complex patients


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 30 - 30
1 Jan 2017
Kuenzler M Akeda M Ihn H McGarry M Zumstein M Lee T
Full Access

Posterolateral rotatory instability (PLRI) is the most common type of elbow instability. It is caused by an insufficiency of the lateral ligamentous complex, which consists mainly of the radial collateral ligament (RCL) and the lateral ulnar collateral ligament (LUCL). Investigate the influence of serial sectioning of the lateral ligamentous complex on elbow stability in a cadaveric model of PLRI. Kinematics of six fresh frozen cadaveric elbow specimens were measured by digitizing anatomical marks with a Microscribe 3DLX digitizing system (Revware Inc, Raleigh, NC). Each specimen was tested under four conditions: Intact, LUCL tear, LUCL and RCL tear, and complete Tear (LUCL, RCL and capsule tear). Each specimen was tested in 30°, 60° and 90° elbow flexion angles. Varus- laxity was measured in supination, pronation, and neutral forearm rotation positions and total forearm rotation was measured with 0.3 Nm of torque. Statistical significant differences between the conditions were detected using a two-way ANOVA with Tukey's post-hoc test. The radial head dislocated in all specimens in LUCL and RCL tear and Comp but not in LUCL tear. Total forearm ROM did not increase form intact to LUCL tear (p>0.05) but significantly increased in LUCL and RCL tear (p=0.0002) and complete tear (p<0.0001) in all flexion angles. Additionally, ROM in LUCL tear significantly differed from LUCL and RCL tear and complete tear (p=0.0027 and p=0.0002). A similar trend was seen with the varus angle. While there was a significant difference when the intact condition was compared to both the LUCLand RCL tear and complete tear conditions (p<0.0001 and p<0.0001), there was no difference between the intact and LUCL tear conditions. LUCL tear alone is not sufficient to cause instability and increase ROM and varus angle, meanwhile the increase of ROM and varus angle with additional capsular tear was not significant compared to LUCL and RCL tear. The increase of ROM after LUCL and RCL tear is an unknown symptom of PLRI


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 15 - 15
1 Aug 2013
McLennan K Wells J Spence S Brooksbank A
Full Access

Reverse total shoulder arthroplasty (RTSA) provides a surgical alternative to conventional shoulder arthroplasty in the rotator cuff deficient shoulder. Short term data has shown consistent improvements in pain and function but higher complication and failure rates have also been reported. The aims of this study were to identify the early and late complications of RTSA, to establish the frequency of glenoid notching, and to assess the post-operative functional outcomes. 21 patients (22 joints) treated with RTSA at Glasgow Royal Infirmary (GRI) between April 2006 and October 2010 were retrospectively reviewed. Indications for surgery included cuff tear arthropathy, revision hemiarthroplasty and fracture malunion. Complication rates were obtained by analysis of follow up data from Bluespier and case notes. Glenoid notching was graded from x-rays by multiple observers using the Sirveaux classification. Outcome was assessed using the Oxford Shoulder Score (OSS) and range of motion (ROM). The complication rate associated with RTSA was 14.3%, effecting 3 patients. One dislocation and 1 ulnar nerve palsy occurred within 30 days post-op. A late complication was represented by 1 dislocation, which required revision. Glenoid notching occurred in 71.4% (15 of 21patients), though the majority had a low Sirveaux classification (grade 1 or 2). OSS increased post-operatively and showed a linear improvement with time (R. 2. = 0.81) and ROM increased significantly post-op compared with pre-op (p<0.001). The complication rate associated with RTSA at GRI was lower than that reported in literature and the outcome was good as defined by ROM and OSS. The rate of glenoid notching was higher than literature reports but the significance of this is unclear as notching may not be associated with loosening


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 17 - 17
1 Mar 2013
Kulshreshtha R Gibson C Jariwala A Wigderowitz C
Full Access

Various authors have linked hypermobility at the trapeziometacarpal joint to future development of arthritis. When examining hypermobility, the anterior oblique ligament (AOL) and ulnar collateral ligament (UCL) are the two most important supporting structures. Literature suggests that reconstructive techniques to correct the hypermobility can prevent subsequent development of osteoarthritis. Eaton and Littler proposed a surgical technique to reconstruct the ligamentous support of this joint in 1973. This cadaveric biomechanical study aimed to evaluate the resultant effect on the mobility of the thumb metacarpal following this reconstructive technique. Seventeen cadaveric hands were prepared and strategically placed on a jig. Movements at the trapeziometacarpal joint were created artificially. Static digital photographs were taken with intact AOL and UCL at trapeziometacarpal joint (controls), for later comparison with those after sectioning of these ligaments and following Eaton-Littler reconstructive technique. The photographic records were analyzed using Scion.Image. Statistical analysis was performed using Minitab. A paired T-test was used to establish statistical relevance. Results confirmed that the AOL and UCL had a major role in limiting excessive motion at the trapeziometacarpal joint, principally in extension. Division of these ligaments produced a significant degree of subluxation of the metacarpal at this joint with thumb in neutral position (p-value = 0.013). Reconstruction of the ligamentous support using the Eaton-Littler technique reduced the degree of extension available (p-value = 0.005). This study confirmed the important role of the AOL and UCL in maintaining trapeziometacarpal joint stability, and that the Eaton-Littler reconstructive technique reduces the degree of hyperextension at this joint


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 95 - 95
1 May 2012
Molony DC Kennedy J Gheiti AC Mullett JH
Full Access

Background. The treatment of olecranon fractures frequently involves the use of tension band fixation. Although associated with high union rates, this method has a high incidence of morbidity associated with soft tissue compromise and limitation of range of movement requiring frequent re-operation for removal of metal. Objectives. We describe the use of a simple jig to ensure intramedullary placement of longitudinal K-wires and compare the accuracy of placement of wires using this device with the traditional free hand method. Methods & Materials. 10 orthopaedic surgical trainees passed 2 longitudinal k wires into synthetic ulnae. This was done using the free hand method and then plastic jig. The ulnae were then sectioned to identify the position of the wires relative to the intramedullary canal. Results. Of the free hand wires, only 11 of 20 were found to be intramedullary versus 20 of 20 in the group passed using the jig. (p<0.001). The mean distance from the center of the ulnar canal was 6.5 mm in the freehand group (range 1-18mm, SD 6.1mm) and 1.6 mm in the O-Jig group (range 1-2mm, SD 0.5mm). The difference in the mean distance from the centre was 4.9mm which was significant (p< 0.001). Conclusions. We found the distance from the centre of the medullary canal, the range and standard deviations of wire positions to be significantly more precise when the jig was used


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 11 - 11
1 Jun 2012
Brown I Pillai A Hems T
Full Access

Our unit has pursued a policy of using donor nerves from the same limb for grafting. Nerves which have already been affected by the primary injury are selected where possible, thus avoiding any new sensory deficit. Methods. 36 of the 41 brachial plexus repairs were available for outcome data collected prospectively over 2 years. Over a nine year period, donor nerves used for the 41 brachial plexus repairs included the lateral cutaneous nerve of the forearm, superficial radial, medial cutaneous of the forearm, ulnar and sural nerves. Patients were grouped into having injured nerve grafts only (A), injured and uninjured nerve grafts (B) and uninjured nerve grafts. The repaired brachial plexus nerves were assessed by measuring the MRC grading of the power of movement of the muscle innervated by that nerve (i.e. elbow flexion for musculocutaneous nerve). These were graded as good (MRC grading 3 or better), fair (MRC grade 1 or 2), or poor (MRC 0). Results. The greatest success for nerve grafting was elbow flexion with good results in 22 out of 27 assessments. Using Mann-Whitney test, Group A had significantly better results (p=0.025) than group C. However, ignoring the poorer results of shoulder abduction there was no significant difference between all 3 groups of patients. Conclusion. Using injured nerve grafts taken distal to the lesion in the brachial plexus is as effective as using nerve material from an uninjured limb


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 272 - 272
1 Jul 2014
Elliott W Sawardeker P Kam C Ouellette A Latta L
Full Access

Summary. Increased lateral ulnotrochlear joint space due to improper sizing in radial head arthroplasty may result in medial collateral ligament laxity, leading to increased osteophytes and arthritis. Introduction. Radial head (RH) arthroplasty is a common response to comminuted RH fractures. Typical complications include improper sizing, leading to changes in joint kinematics. Evidence of these changes should be visible through fluoroscopic images of affected joints. The two examined changes in this study are the ulnar deviation from distal radial translation (DRT), and the widening of the lateral ulnotrochlear joint space (LUT). Methods. Eight fresh-frozen cadaver arms were used. Initial images were taken with the native RH intact. The Kocher approach exposed the radiocapitellar (RC) joint capsule, preserving all ligaments. The RH was excised and Integra Katalyst CoCr (Plainsboro, NJ) telescoping, bipolar, RH inserted. Images were taken with implant sizings: −2mm, 0mm, +2mm, and +4mm, (from native) using 1mm washers preventing implant bipolarity. AP fluoroscopic images of the elbow were taken at full extension. Joint spaces were measured using image analysis, normalised using known radio-opaque lengths. Four LUT measurements were made, two medially and two laterally, and normalised by measuring the RH implant diameter. Each set (medial and lateral) were averaged together and the resulting value used for all comparisons. Images of distal ulnar deviation at the wrist were taken with the wrist in supination, the hand rotated medially. Measurements were from the distal medial radial tip to the distal lateral ulnar tip. Images were normalised by placing a scalpel in the same plane as measurement. Results. DRT values were difference paired for each arm using the 0mm values as baselines. One-way ANOVA of the paired values resulted in significant DT with sizing increases (p<0.01). The quotient of DRT and sizing determined comparative impact with the LUT increase. LUT joint gap measurements were percentage paired, with natives as the baseline, and One-way ANOVA used. A significant increase in LUT spacing occurred with increased sizings (p<0.01). Discussion. Increased ulnar deviation can increase loading on the TFCC, leading to possible TFCC tear, increased articular cartilage wear from carpal misalignment, and eventual wrist instability and arthritis. The percentage of the radial lengthening is represented in DRT. Over-sizing results in small percentages of increased radial length at the wrist, therefore deviation at the elbow must take place, either through rotation of the ulna, or translation. Either of these can be seen through LUT measurements. Previous measurements of the LUT space were made by Frank (2009), with similar results. This was being used as a method of improper sizing detection using radiographs. The percentage difference of LUT space for corresponding sizing: there is an increase in LUT space for every sizing; maybe due to loosening of the soft tissue from arthroplasty. Increased LUT space indicates the medial translation of proximal ulna. This can result in Medial Collateral Ligament laxity, leading to increased osteophytes, and arthritis. Use and non-treatment, can create a chronic, painful, disorder


Bone & Joint 360
Vol. 9, Issue 3 | Pages 8 - 9
1 Jun 2020


Bone & Joint Research
Vol. 5, Issue 7 | Pages 301 - 306
1 Jul 2016
Madhuri V Santhanam M Rajagopal K Sugumar LK Balaji V

Objectives

To determine the pattern of mutations of the WISP3 gene in clinically identified progressive pseudorheumatoid dysplasia (PPD) in an Indian population.

Patients and Methods

A total of 15 patients with clinical features of PPD were enrolled in this study. Genomic DNA was isolated and polymerase chain reaction performed to amplify the WISP3 gene. Screening for mutations was done by conformation-sensitive gel electrophoresis, beginning with the fifth exon and subsequently proceeding to the remaining exons. Sanger sequencing was performed for both forward and reverse strands to confirm the mutations.


Bone & Joint Research
Vol. 4, Issue 11 | Pages 176 - 180
1 Nov 2015
Mirghasemi SA Rashidinia S Sadeghi MS Talebizadeh M Rahimi N

Objectives

There are various pin-in-plaster methods for treating fractures of the distal radius. The purpose of this study is to introduce a modified technique of ‘pin in plaster’.

Methods

Fifty-four patients with fractures of the distal radius were followed for one year post-operatively. Patients were excluded if they had type B fractures according to AO classification, multiple injuries or pathological fractures, and were treated more than seven days after injury. Range of movement and functional results were evaluated at three and six months and one and two years post-operatively. Radiographic parameters including radial inclination, tilt, and height, were measured pre- and post-operatively.