Introduction.
Utilisation of
For patients suffering from osteoarthritis confined to one compartment of the knee joint, a successful
NavioPFS™ is a hand-held robotic technology for bone shaping that employs computer control of a high-speed bone drill. There are two control modes – one based on control of exposure of the cutting bur and another based on the control of the speed of the cutting bur. The
Knee osteoarthritis results in pain and functional limitations. In cases where the arthritis is limited to one compartment of the knee joint then a
Lower limb alignment after
Lower limb alignment after
Introduction. Limb alignment after
Background. Current analysis of
Background. In a mobile-bearing
Purpose. The purpose of this study was to examine the progression of osteoarthritis (OA) on patella-femoral joint (PFJ) after open wedge high tibial osteotomy (OWHTO) and
With the introduction of minimally invasive surgery techniques and improved polyethylene wear properties, there has been a renewed interest in Unicondylar Knee Replacements (UKR). Customized, Individually Made (CIM) UKR have been in the market for some time, and have shown to provide improved coverage and fit. The purpose of this study was to assess clinical and patient-reported outcomes utilizing CIM-UKR prostheses. A prospectively recruited cohort of 118 patients was implanted with 120 CIM-UKR (110 medial/10 lateral) at multiple centers across the US. Patients were diagnosed with uni-compartmental osteoarthritis of the medial or lateral compartment. Patients with compromised cruciate or collateral ligaments or having a varus/valgus deformity <15° were excluded. Patients were assessed for Knee Society Knee and Function Scores, WOMAC & ROM pre-operatively (120 patients), at 6-weeks post-op (119), 6-months post-op (71 optional visit), 1 year post-op (113) and 2 years post-operatively (96). For the 3 and 4 year post-operative time points, patients were contacted to report on any possible adverse events.Introduction
Methods
Two fixed bearing options exist for tibial resurfacing when performing unicompartmental knee arthroplasty (UKA). Inlay components are polyethylene-only implants inserted into a carved pocket on the tibial surface, relying upon the subchondral bone to support the implant. Onlay components have a metal base plate and are placed on top of a flat tibial cut, supported by a rim of cortical bone. To our knowledge, there is no published report that compares the clinical outcomes of these two implants using a robotically controlled surgical technique. We performed a retrospective review of a single surgeon's experience with Inlay versus Onlay components, using a robotic-guided protocol. All surgeries were performed using the same planning software and robotic guidance for execution of the surgical plan (Mako Surgical, Fort Lauderdale, FL). The senior surgeon's prospective database was reviewed to identify patients with 1) medial-sided UKA and 2) at least two years of clinical follow up. Eighty-six patients met these inclusion/exclusion criteria: 41 Inlays and 45 Onlays. Five patients underwent a secondary or revision procedure during the follow up period and were considered separately. Our primary outcome was the WOMAC score, subcategorized by the Pain, Stiffness, and Function sub-scores. The secondary outcome was need for secondary surgery. Continuous variables were analyzed using the two-tailed Student's t-test; categorical variables were analyzed using Fisher's exact test.Introduction:
Methods:
Historically, the outcomes of knee replacement were evaluated based on implant longevity, major complications and range of motion. Over the last recent years however, there has been an intensively growth of interest in the patient's perception of functional outcome. However, the currently used patient related outcome (PRO) scores are limited by ceiling effects which limit the possibility to distinguish between good and excellent results post knee arthroplasty. The Forgotten Joint Score (FJS) is a new PRO score which is not influenced by ceiling effects, therefore making it the ideal instrument to compare functional outcome between various types of implants. It is based on the thought that the ultimate goal in joint arthroplasty is the ability of a patient to forget their artificial joint in everyday life. The aim of this study is to compare the FJS between patients who undergo TKA and patients who undergo medial UKA at least 12 months post-operatively. We hypothesized that the UKA which is less extensive surgical procedure will present better FJS than TKA, even 12 month postoperative. All patients who underwent medial UKA or TKA were contacted 12 months post-operatively. They were asked to complete the FJS, the Western Ontario and McMasters Universities Osteoarthritis index (WOMAC) and the EuroQol-5D (EQ-5D). A priori power analysis was conducted using two-sample t-test. 64 patients in each group were needed to reach 80% power for detecting a 12 point (SD 24) significant difference on the FJS scale with a two-sided significant level of 0.05. A p-value <0.05 was considered as statistically significant.Introduction
Methods
Introduction. The purpose of this study was to characterize the recovery of physical activity following knee arthroplasty by means of step counts and flight counts (flights of stairs) measured using a smartphone-based care platform. Methods. This is a secondary data analysis on the treatment cohort of a multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total and unicondylar joint arthroplasty. Participants in the treatment arm that underwent primary total or
Abstract. Background. The use of tourniquet in knee arthroplasty is common but in recent times, it has initiated a debate on its use. Complications from use of tourniquet are well documented in literature but there is less evidence on thigh pain, blood loss and length of stay post arthroplasty. Methods. We included 62 patients undergoing
Introduction. Recent advances in algorithms developed with passively collected sensor data from smart phones and watches demonstrate new, objective, metrics with the capacity to show qualitative gait characteristics. The purpose of this feasibility study was to assess the recovery of gait quality following primary total hip and knee arthroplasty collected using a smartphone-based care platform. Methods. A secondary data analysis of an IRB approved multicenter prospective trial evaluating the use of a smartphone-based care platform for primary total knee arthroplasty (TKA, n=88),
The knee is one of the most commonly affected joints in osteoarthritis. Unicompartmental knee replacement (UKA) was developed to address patients with this disease in only one compartment. The conventional knee arthroplasty jigs, while usually being accurate, may result in the prosthesis being inserted in an undesired alignment which may lead to poor post-operative outcomes. Common modes of failure in UKA include edge loading due to incorrect sizing or positioning, development of disease in the other compartment due to over-stuffing or over-correction and early loosening or stress fractures due to inaccurate bone cuts. Computer navigation and robotically assisted unicompartmental knee replacement were introduced in order to improve the surgical accuracy of both the femoral and tibial bone cuts. The aim of this study was to assess accuracy and reliability of robotic assisted, unicondylar knee surgery in producing reported bony alignment. Two hundred and twenty consecutive patients with a mean age of 64 + 11 years who underwent successful medial robotic assisted unicondylar knee surgery performed by two senior total joint arthroplasty surgeons were identified retrospectively. The mean body mass index of the cohort was 33.5 + 8 kg/m. 2. with a minimum follow-up of 6 months (range: 6–18 months). Femoral and tibial sagittal and coronal alignments as well as the posterior slope of the tibial component were measured in the post-operative radiographs. These measurements were compared with the equivalent measurements collected during intra-operative period by the navigation to study the reliability and accuracy of femoral and tibial cuts. Radiographic evaluation was independently conducted by two observers. There was an average difference of 2.2 to 3.6 degrees between the intra-operatively planned and post-operative radiological equivalent measurements. For the femur, mean varus/valgus angulation was 2.8 + 2.5 degrees with 83% of those measured within 5% of planned. For the tibia mean varus/valgus angulation was 2.4 + 1.9 degrees with 93% within 5% of planned resection. There was minimal inter-observer variability between radiographic measurements. There were no infections in the evaluated group at the time of radiographic examination. Alignment for