Abstract. Introduction. Fractures of the articular surface of the patella or the lateral femoral condyle usually occur following acute dislocation of the patella. This study looked at the radiological and functional outcomes of fixation of osteochondral fractures. Methods. Twenty-nine patients (18 male, 11 female) sustained osteochondral fractures of the knee following patellar dislocation. All patients had detailed radiographic imaging and MRI scan of the knee preoperatively. An arthroscopic assessment was done, followed by fixation using bio-absorbable pins or headless screws either arthroscopically or mini-open arthrotomy. VMO plication or MPFL repair were done if necessary. MRI scan was done at follow-up to assess for healing of the fixed fragment prior to patient discharge. Results. The mean age of the patients was 21 yrs (9–74), 11 had osteochondral fracture of the patella (38%), while 18 were from the lateral femoral condyle (62%). 13 patients needed additional VMO plication. Mean follow up period was 7.7 years (1 to 12 years). As per Tegner activity scale, all patients returned to their pre-injury activity level (Mean score 7) and sports. None of the patients had a further episode of patellar dislocation. Mean postoperative IKDC score was 86.5 (SD 17.3), Kujala was 91.1(SD 15.5) and Tegner- lysholm was 88.7 (SD 14.4). All patients had statistically significant (p < 0.05) improvement. Post-operative MRI scan showed satisfactory
Aims. Tibial tubercle osteotomy (TTO) facilitates surgical exposure and protects the extensor mechanism during revision total knee arthroplasty (rTKA). The purpose of this study was to determine the rates of bony union, complications, and reoperations following TTO during rTKA, to assess the functional outcomes of rTKA with TTO at two years’ minimum follow-up, and to identify the risk factors of failure. Methods. Between January 2010 and September 2020, 695 rTKAs were performed and data were entered into a prospective database. Inclusion criteria were rTKAs with concomitant TTO, without extensor mechanism allograft, and a minimum of two years’ follow-up. A total of 135 rTKAs were included, with a mean age of 65 years (SD 9.0) and a mean BMI of 29.8 kg/m. 2. (SD 5.7). The most frequent indications for revision were infection (50%; 68/135), aseptic loosening (25%; 34/135), and stiffness (13%; 18/135). Patients had standardized follow-up at six weeks, three months, six months, and annually thereafter. Complications and revisions were evaluated at the last follow-up. Functional outcomes were assessed using the Knee Society Score (KSS) and range of motion. Results. The mean follow-up was 51 months (SD 26; 24 to 121). Bony union was confirmed in 95% of patients (128/135) at a mean of 3.4 months (SD 2.7). The complication rate was 15% (20/135), consisting of nine tibial tubercle fracture displacements (6.7%), seven nonunions (5%), two delayed
Abstract. Introduction. Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy
Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and comminution seem manageable, but at times, the construct does not permit early mobilization. Considerable soft tissue stripping during open reduction and internal fixation (ORIF) may delay
Abstract. Introduction. Distal Femoral Fractures around a Total Knee Replacement have a reported incidence of 0.25–2.3% of primary TKRs. Literature suggests that these fractures have high complication rates such as non
To evaluate whether low-intensity pulsed ultrasound (LIPUS) accelerates bone healing at osteotomy sites and promotes functional recovery after open-wedge high tibial osteotomy (OWHTO). Overall, 90 patients who underwent OWHTO without bone grafting were enrolled in this nonrandomized retrospective study, and 45 patients treated with LIPUS were compared with 45 patients without LIPUS treatment in terms of bone healing and functional recovery postoperatively. Clinical evaluations, including the pain visual analogue scale (VAS) and Japanese Orthopaedic Association (JOA) score, were performed preoperatively as well as six weeks and three, six, and 12 months postoperatively. The progression rate of gap filling was evaluated using anteroposterior radiographs at six weeks and three, six, and 12 months postoperatively.Aims
Methods
The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution.Aims
Methods
Periprosthetic fractures (PPFs) around the knee are challenging injuries. This study aims to describe the characteristics of knee PPFs and the impact of patient demographics, fracture types, and management modalities on in-hospital mortality. Using a multicentre study design, independent of registry data, we included adult patients sustaining a PPF around a knee arthroplasty between 1 January 2010 and 31 December 2019. Univariate, then multivariable, logistic regression analyses were performed to study the impact of patient, fracture, and treatment on mortality.Aims
Methods
We retrospectively evaluated eight patients who underwent arthrodesis of the knee using cannulated screws. There were six women and two men, with a mean age of 53 years. The indications for arthrodesis were failed total knee arthroplasty, septic arthritis, tuberculosis, and recurrent persistent infection. Solid
The objective of this study was to validate the
efficacy of Takeuchi classification for lateral hinge fractures
(LHFs) in open wedge high tibial osteotomy (OWHTO). In all 74 osteoarthritic
knees (58 females, 16 males; mean age 62.9 years, standard deviation
7.5, 42 to 77) were treated with OWHTO using a TomoFix plate. The
knees were divided into non-fracture (59 knees) and LHF (15 knees)
groups, and the LHF group was further divided into Takeuchi types
I, II, and III (seven, two, and six knees, respectively). The outcomes
were assessed pre-operatively and one year after OWHTO. Pre-operative
characteristics (age, gender and body mass index) showed no significant
difference between the two groups. The mean Japanese Orthopaedic
Association score was significantly improved one year after operation
regardless of the presence or absence of LHF (p = 0.0015, p <
0.001, respectively). However, six of seven type I cases had no
LHF-related complications; both type II cases had delayed
Introduction. In the setting of periprosthetic joint infection, the complete removal of implants and cement can be challenging with well-fixed, cemented implants about the knee. This can get especially complex in the setting of long cemented femoral stems. Osteotomies are well described in the proximal femur and tibia for removal of implants and cement. There is little information available on distal femoral osteotomies to facilitate knee implant and retained cement removal. Methods. We describe a novel anterolateral oblique distal femoral osteotomy for the removal of well-fixed, cemented components during resection knee arthroplasty that preserves vascularity to the osteotomized segment. Cadaveric anatomic vascular injection studies were performed to document vascularity of the osteotomized segment. Clinical examples, and results will be presented. Results. Anatomic vascular studies documented preserved vascularity to the osteotomized segment. In two patients intramedullary infected implant and cement was completely removed. At reimplantation and final followup the osteotomy was radiographically healed, implants well fixed, and no recurrent infections were noted. Conclusions. This osteotomy appears to be useful when removing well fixed, cemented femoral components during periprosthetic infection. Vascularity and
Introduction. While knee arthrodesis is a salvage option for recalcitrant total knee arthroplasty (TKA) periprosthetic joint infection (PJI) it is used relatively uncommonly and contemporary data are limited. We sought to determine the reliability, durability and safety of knee arthrodesis as the definitive treatment for complex, persistently infected TKA in a modern series of patients. Methods. We retrospectively identified 41 knees treated from 2002–2016 with a deliberate, two-stage knee arthrodesis protocol (TKA resection, high-dose antibiotic spacer, targeted IV antibiotics and followed by subsequent knee arthrodesis) in patients with complex TKA PJI. Mean age was 64 years & mean BMI was 39 kg/m. 2. Mean follow-up was 4 years. The extensor mechanism was deficient in 66% of knees, and flap coverage was required in 34% of knees. The majority of patients were host grade B (56%) or C (29%), and extremity grade of 3 (71%). Twenty-nine percent had poly-microbial infections, and 49% had multi-drug resistant organisms. Fixation included intramedullary nail (61%), external fixator (24%), and dual plating (15%). Results. Two patients (5%) required amputation for persistently infected non-unions; therefore, limb salvage was accomplished in 95% of patients. After initial treatment, there were non-unions in 24% and persistent infection in 17%. Non-union was significantly correlated with persistent infection, with 50% of non-unions having persistent infection compared with just 6% of united knees (p=0.006). External fixation was a significant risk factor for non-union (70%) compared to intramedullary fixation (8%; p=0.005). Overall, twenty-seven complications occurred in 20 patients and 31% required reoperation other than external fixator removal. Intramedullary fixation led to a 90% rate of both infection control and radiographic
This animal study compares different methods
of performing an osteotomy, including using an Erbium-doped Yttrium
Aluminum Garnet laser, histologically, radiologically and biomechanically.
A total of 24 New Zealand rabbits were divided into four groups
(Group I: multihole-drilling; Group II: Gigli saw; Group III: electrical
saw blade and Group IV: laser). A proximal transverse diaphyseal
osteotomy was performed on the right tibias of the rabbits after the
application of a circular external fixator. The rabbits were killed
six weeks after the procedure, the operated tibias were resected
and radiographs taken. . The specimens were tested biomechanically using three-point bending
forces, and four tibias from each group were examined histologically.
Outcome parameters were the biomechanical stability of the tibias
as assessed by the failure to load and radiographic and histological
examination of the osteotomy site. . The osteotomies healed in all specimens both radiographically
and histologically. The differences in the mean radiographic (p
= 0.568) and histological (p = 0.71) scores, and in the mean failure
loads (p = 0.180) were not statistically significant between the
groups. . Different methods of performing an osteotomy give similar quality
of
Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia. In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee.Aims
Methods
To determine the relationship between articular cartilage status and clinical outcomes after medial opening-wedge high tibial osteotomy (MOHTO) for medial compartmental knee osteoarthritis at intermediate follow-up. We reviewed 155 patients (155 knees) who underwent MOHTO from January 2008 to December 2016 followed by second-look arthroscopy with a mean 5.3-year follow-up (2.0 to 11.7). Arthroscopic findings were assessed according to the International Cartilage Repair Society (ICRS) Cartilage Repair Assessment (CRA) grading system. Patients were divided into two groups based on the presence of normal or nearly normal quality cartilage in the medial femoral condyle: good (second-look arthroscopic) status (ICRS grade I or II; n = 70), and poor (second-look arthroscopic) status (ICRS grade III or IV; n = 85) groups at the time of second-look arthroscopy. Clinical outcomes were assessed using the International Knee Documentation Committee (IKDC) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and 36-Item Short Form survey.Aims
Methods
Debate continues regarding the optimum management of periprosthetic distal femoral fractures (PDFFs). This study aims to determine which operative treatment is associated with the lowest perioperative morbidity and mortality when treating low (Su type II and III) PDFFs comparing lateral locking plate fixation (LLP-ORIF) or distal femoral arthroplasty (DFA). This was a retrospective cohort study of 60 consecutive unilateral (PDFFs) of Su types II (40/60) and III (20/60) in patients aged ≥ 60 years: 33 underwent LLP-ORIF (mean age 81.3 years (SD 10.5), BMI 26.7 (SD 5.5); 29/33 female); and 27 underwent DFA (mean age 78.8 years (SD 8.3); BMI 26.7 (SD 6.6); 19/27 female). The primary outcome measure was reoperation. Secondary outcomes included perioperative complications, calculated blood loss, transfusion requirements, functional mobility status, length of acute hospital stay, discharge destination and mortality. Kaplan-Meier survival analysis was performed. Cox multivariate regression analysis was performed to identify risk factors for reoperation after LLP-ORIF.Aims
Methods
We treated 22 patients with type-two odontoid fractures in halothoracic vests for six to eight weeks followed by a Philadelphia collar for four weeks. Eighteen patients were reviewed by questionnaire and radiography at a mean of 40 months after injury. We assessed
Nine patients underwent arthrodesis of the knee using a customised coupled nail (the Mayday arthrodesis nail), five after infected arthroplasty, one following failed arthrodesis, one for intractable anterior knee pain, one for Charcot instability and one after trauma. Comparison was made with 17 arthrodeses, eight undertaken using external fixation, four with dual compression plates, and five with long Küntscher nails.
Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients. We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m2 (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%).Aims
Methods
We compared the results ten years after an inverted V-shaped high tibial osteotomy with those of a historical series of conventional closing-wedge osteotomies. The closing-wedge series consisted of 56 knees in 51 patients with a mean follow-up of 11 years (10 to 15). The inverted V-shaped osteotomy was evaluated in 48 knees in 43 patients at a mean follow-up of 14 years (10 to 19). All the patients were scored using the Japanese Orthopaedic Association rating scale for osteoarthritis of the knee and radiological assessment. The pre-operative grade of osteoarthritis was similar in both groups. Post-operatively, the knee function score was graded as satisfactory in 63% (35) of the closing-wedge group but in 89% (43) of the inverted V-shaped osteotomy group. Post-operative radiological examination showed that delayed