Advertisement for orthosearch.org.uk
Results 1 - 20 of 105
Results per page:
The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 396 - 400
1 Mar 2013
Rhee SH Kim J Lee YH Gong HS Lee HJ Baek GH

The purpose of this study was to evaluate the risk of late displacement after the treatment of distal radial fractures with a locking volar plate, and to investigate the clinical and radiological factors that might correlate with re-displacement. From March 2007 to October 2009, 120 of an original cohort of 132 female patients with unstable fractures of the distal radius were treated with a volar locking plate, and were studied over a follow-up period of six months. In the immediate post-operative and final follow-up radiographs, late displacement was evaluated as judged by ulnar variance, radial inclination, and dorsal angulation. We also analysed the correlation of a variety of clinical and radiological factors with re-displacement. Ulnar variance was significantly overcorrected (p < 0.001) while radial inclination and dorsal angulation were undercorrected when compared statistically (p <  0.001) with the unaffected side in the immediate post-operative stage. During follow-up, radial shortening and dorsal angulation progressed statistically, but none had a value beyond the acceptable range. Bone mineral density measured at the proximal femur and the position of the screws in the subchondral region, correlated with slight progressive radial shortening, which was not clinically relevant. Volar locking plating of distal radial fractures is a reliable form of treatment without substantial late displacement. Cite this article: Bone Joint J 2013;95-B:396–400


Aims. The aim of this study was to compare patient-reported outcome measures (PROMs) and the Single Assessment Numerical Evaluation (SANE) score in patients treated with a volar locking plate for a distal radial fracture. Methods. This study was a retrospective review of a prospective database of 155 patients who underwent internal fixation with a volar locking plate for a distal radial fracture between August 2014 and April 2017. Data which were collected included postoperative PROMs (Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH) and Patient-Rated Wrist Evaluation (PRWE)), and SANE scores at one month (n = 153), two months (n = 155), three months (n = 144), six months (n = 128), and one year (n = 73) after operation. Patients with incomplete data were excluded from this study. Correlation and agreement between PROMs and SANE scores were evaluated. Subgroup analyses were carried out to identify correlations according to variables such as age, the length of follow-up, and subcategories of the PRWE score. Results. The Pearson correlation coefficient (r) between PROMs and SANE scores was -0.76 (p < 0.001) for DASH and -0.72 (p < 0.001) for PRWE, respectively. Limits of agreement between PROMs and ‘100-SANE’ scores were met for at least 93% of the data points. In subgroup analysis, there were significant negative correlations between PROMs and SANE scores for all age groups and for follow-up of more than six months. The correlation coefficient between PRWE subcategories and SANE score was -0.67 (p < 0.001) for PRWE pain score and -0.69 (p < 0.001) for PRWE function score, respectively. Conclusion. We found a significant correlation between postoperative SANE and PROMs in patients treated with a volar locking plate for a distal radial fracture. The SANE score is thus a reliable indicator of outcome for patients who undergo surgical treatment for a radial fracture. Cite this article: Bone Joint J 2020;102-B(6):744–748


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1101 - 1105
1 Aug 2013
Haug LC Glodny B Deml C Lutz M Attal R

Penetration of the dorsal screw when treating distal radius fractures with volar locking plates is an avoidable complication that causes lesions of the extensor tendon in between 2% and 6% of patients. We examined axial fluoroscopic views of the distal end of the radius to observe small amounts of dorsal screw penetration, and determined the ideal angle of inclination of the x-ray beam to the forearm when making this radiological view. Six volar locking plates were inserted at the wrists of cadavers. The actual screw length was measured under direct vision through a dorsal approach to the distal radius. Axial radiographs were performed for different angles of inclination of the forearm at the elbow. Comparing axial radiological measurements and real screw length, a statistically significant correlation could be demonstrated at an angle of inclination between 5° and 20°. The ideal angle of inclination required to minimise the risk of implanting over-long screws in a dorsal horizon radiological view is 15°. Cite this article: Bone Joint J 2013;95-B:1101–5


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 957 - 962
1 Jul 2015
Yamazaki H Uchiyama S Komatsu M Hashimoto S Kobayashi Y Sakurai T Kato H

There is no consensus on the benefit of arthroscopically assisted reduction of the articular surface combined with fixation using a volar locking plate for the treatment of intra-articular distal radial fractures. In this study we compared the functional and radiographic outcomes of fluoroscopically and arthroscopically guided reduction of these fractures. Between February 2009 and May 2013, 74 patients with unilateral unstable intra-articular distal radial fractures were randomised equally into the two groups for treatment. The mean age of these 74 patients was 64 years (24 to 92). We compared functional outcomes including active range of movement of the wrist, grip strength and Disabilities of the Arm, Shoulder, and Hand scores at six and 48 weeks; and radiographic outcomes that included gap, step, radial inclination, volar angulation and ulnar variance. . There were no significant differences between the techniques with regard to functional outcomes or radiographic parameters. The mean gap and step in the fluoroscopic and arthroscopic groups were comparable at 0.9 mm (standard deviation. (sd). 0.7) and 0.7 mm (. sd. 0.7) and 0.6 mm (. sd. 0.6) and 0.4 mm (. sd. 0.5), respectively; p = 0.18 and p = 0.35). . Arthroscopic reduction conferred no advantage over conventional fluoroscopic guidance in achieving anatomical reduction of intra-articular distal radial fractures when using a volar locking plate. Cite this article: Bone Joint J 2015; 97-B:957–62


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1090 - 1096
1 Aug 2012
Mahmoud M El Shafie S Kamal M

Malunion is the most common complication of the distal radius with many modalities of treatment available for such a problem. The use of bone grafting after an osteotomy is still recommended by most authors. We hypothesised that bone grafting is not required; fixing the corrected construct with a volar locked plate helps maintain the alignment, while metaphyseal defect fills by itself. Prospectively, we performed the procedure on 30 malunited dorsally-angulated radii using fixed angle volar locked plates without bone grafting. At the final follow-up, 22 wrists were available. Radiological evidence of union, correction of the deformity, clinical and functional improvement was achieved in all cases. Without the use of bone grafting, corrective open wedge osteotomy fixed by a volar locked plate provides a high rate of union and satisfactory functional outcomes


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 229 - 234
1 Feb 2015
Choi W Lee HJ Kim D Lee C Lee BG Kim J Lee K

We performed a retrospective study to determine the effect of osteoporosis on the functional outcome of osteoporotic distal radial fractures treated with a volar locking plate. Between 2009 and 2012 a total of 90 postmenopausal women with an unstable fracture of the distal radius treated with a volar locking plate were studied. Changes in the radiological parameters of 51 patients with osteoporosis (group 1, mean age 66.9, mean T-score –3.16 (. sd.  0.56)) were not significantly different from those in 39 patients without osteoporosis (group 2, mean age 61.1, mean T-score –1.72 (. sd. 0.57)). The mean Disabilities of the Arm, Shoulder and Hand (DASH) score at final follow-up was 11.5 (. sd. 12.2) in group 1 and 10.5 (. sd.  13.25) in group 2. The mean modified Mayo wrist score at final follow-up was 79.0 (. sd.  14.04) in group 1 and 82.6 (. sd. 13.1) in group 2. However, this difference was not statistically significant (p = 0.35 for DASH score, p = 0.2 for modified Mayo wrist score). Univariable and multivariable logistic regression analysis showed that only the step-off of the radiocarpal joint was related to both a poor DASH and modified Mayo wrist score. Pearson’s correlation coefficient showed a weak negative relationship only between the T-score and the change in volar tilt (intraclass coefficient –0.26, p = 0.02). We found that osteoporosis does not have a negative effect on the functional outcome and additional analysis did not show a correlation between T-score and outcome. Cite this article: Bone Joint J 2015;97-B:229–34


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 247 - 255
1 Feb 2021
Hassellund SS Williksen JH Laane MM Pripp A Rosales CP Karlsen Ø Madsen JE Frihagen F

Aims. To compare operative and nonoperative treatment for displaced distal radius fractures in patients aged over 65 years. Methods. A total of 100 patients were randomized in this non-inferiority trial, comparing cast immobilization with operation with a volar locking plate. Patients with displaced AO/OTA A and C fractures were eligible if one of the following were found after initial closed reduction: 1) dorsal angulation > 10°; 2) ulnar variance > 3 mm; or 3) intra-articular step-off > 2 mm. Primary outcome measure was the abbreviated version of the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH) after 12 months. Secondary outcome measures were the Patient-Rated Wrist and Hand Evaluation (PRWHE), EuroQol-5 dimensions 5-level questionnaire (EQ-5D-5L), range of motion (ROM), grip strength, “satisfaction with wrist function” (score 0 to 10), and complications. Results. In all, 89 women and 11 men were included. Mean age was 74 years (65 to 91). Nonoperative treatment was non-inferior to operation with a five-point difference in median QuickDASH after 12 months (p = 0.206). After three and six months QuickDASH favoured the operative group (p = 0.010 and 0.030). Median values for PRWHE were 19 (interquartile range (IRQ) 10 to 32) in the operative group versus ten (IQR 1 to 31) in the nonoperative group at three months (p = 0.064), nine (IQR 2 to 20) versus five (IQR 0 to 13) (p = 0.020) at six months, and two (IQR 0 to 12) versus zero (IQR 0 to 8) (p = 0.019) after 12 months. Range of motion was similar between the groups. The EQ-5D-5L index score was better (mean difference 0.07) in the operative group at three and 12 months (p = 0.008 and 0.020). The complication rate was similar (p = 0.220). The operated patients were more satisfied with wrist function (median 8 (IQR 6 to 9) vs 6 (IQR 5 to 7) at three months, p = 0.002; 9 (IQR 7 to 9) vs 8 (IQR 6 to 8) at six months, p = 0.002; and 10 (IQR 8 to 10) vs 8 (IQR 7 to 9) at 12 months, p < 0.001). Conclusion. Nonoperative treatment was non-inferior to operative treatment based on QuickDASH after one year. Patients in the operative group had a faster recovery and were more satisfied with wrist function. Results from previous trials comparing operative and nonoperative treatment for displaced distal radius fractures in the elderly vary between favouring the operative group and showing similar results between the treatments. This randomized trial suggests that most elderly patients may be treated nonoperatively. Cite this article: Bone Joint J 2021;103-B(2):247–255


The Bone & Joint Journal
Vol. 103-B, Issue 2 | Pages 245 - 246
1 Feb 2021
Hassellund SS Williksen JH Laane MM Pripp A Rosales CP Karlsen Ø Madsen JE Frihagen F


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1610 - 1612
1 Dec 2006
Al-Rashid M Theivendran K Craigen MAC

The use of volar locking compression plates for the treatment of fractures of the distal radius is becoming increasingly popular because of the stable biomechanical construct, less soft-tissue disturbance and early mobilisation of the wrist. A few studies have reported complications such as rupture of flexor tendons. We describe three cases of rupture of extensor tendons after the use of volar locking compression plates. We recommend extreme care when drilling and placing the distal radial screws to prevent damaging the extensor tendons


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 136 - 136
1 Sep 2012
Munro C Baliga S Johnstone A Carnegie C
Full Access

Volar Locking Plates (VLP) have revolutionised the treatment of distal radius fractures allowing the anatomic reduction and stable fixation of the more comminuted and unstable of fractures. The benefits of this in terms of range of movement (ROM), pain and earlier return to work and daily activities is documented. However we were interested in was what improvements in wrist function patients made from 6 to 12 months after injury?

Methods

We retrospectively looked at a series of 34 consecutive patients that had undergone VLP fixation through a standard anterior approach followed by early physiotherapy. We documented standard demographics and assessed function in terms of Range of Movement, Grip strength (GS), Modified Gartland and Werley score (MGWS), Patient Rated Wrist Evaluation (PRWE) and the quick DASH questionnaire at six and twelve months

Results

Two patients were excluded from analysis as they failed to make both assessments. Of the 32 remaining (26 female:6 male) the mean age was 53.2yrs; range (26–78). On average GS, PGS, VAS function and pain did not improve. There was a modest improvement in Movement; Wrist Flexon-13 deg, Wrist Extension-14deg, Radial Deviation-7deg, Ulnar Deviation-9deg. There was no improvement in pronation and supination.

There was little improvement in qDASH, PRWE and mGW Scores with only a mean 1.8, 5.6 and 3.6 point improvement respectively.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1271 - 1275
1 Oct 2008
Downing ND Karantana A

The recent development of locking-plate technology has led to a potential revolution in the management of fractures of the distal radius. This review examines the evidence for pursuing anatomical restoration of the distal radius and the possible advantages and pitfalls of using volar locking plates to achieve this goal. The available evidence for adopting volar locking plates is presented and a number of important and, as yet unanswered, questions are highlighted


Bone & Joint 360
Vol. 12, Issue 6 | Pages 27 - 31
1 Dec 2023

The December 2023 Wrist & Hand Roundup. 360. looks at: Volar locking plate for distal radius fractures with patient-reported outcomes in older adults; Total joint replacement or trapeziectomy?; Replantation better than revision amputation in traumatic amputation?; What factors are associated with revision cubital tunnel release within three years?; Use of nerve conduction studies in carpal tunnel syndrome; Surgical site infection following surgery for hand trauma: a systematic review and meta-analysis; Association between radiological and clinical outcomes following distal radial fractures; Reducing the carbon footprint in carpal tunnel surgery inside the operating room with a lean and green model: a comparative study


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 93 - 93
1 Jul 2020
Gueorguiev B Hadzhinikolova M Zderic I Ciric D Enchev D Baltov A Rusimov L Richards G Rashkov M
Full Access

Distal radius fractures have an incidence rate of 17.5% among all fractures. Their treatment in case of comminution, commonly managed by volar locking plates, is still challenging. Variable-angle screw technology could counteract these challenges. Additionally, combined volar and dorsal plate fixation is valuable for treatment of complex fractures at the distal radius. Currently, biomechanical investigation of the competency of supplemental dorsal plating is scant. The aim of this study was to investigate the biomechanical competency of double-plated distal radius fractures in comparison to volar locking plate fixation. Complex intra-articular distal radius fractures AO/OTA 23-C 2.1 and C 3.1 were created by means of osteotomies, simulating dorsal defect with comminution of the lunate facet in 30 artificial radii, assigned to 3 study groups with 10 specimens in each. The styloid process of each radius was separated from the shaft and the other articular fragments. In group 1, the lunate facet was divided to 3 equally-sized fragments. In contrast, the lunate in group 2 was split in a smaller dorsal and a larger volar fragment, whereas in group 3 was divided in 2 equal fragments. Following fracture reduction, each specimen was first instrumented with a volar locking plate and non-destructive quasi-static biomechanical testing under axial loading was performed in specimen's inclination of 40° flexion, 40° extension and 0° neutral position. Mediolateral radiographs were taken under 100 N loads in flexion and extension, as well as under 150 N loads in neutral position. Subsequently, all biomechanical tests were repeated after supplemental dorsal locking plate fixation of all specimens. Based on machine and radiographic data, stiffness and angular displacement between the shaft and lunate facet were determined. Stiffness in neutral position (N/mm) without/with dorsal plating was on average 164.3/166, 158.5/222.5 and 181.5/207.6 in groups 1–3. It increased significantly after supplementary dorsal plating in groups 2 and 3. Predominantly, from biomechanical perspective supplemental dorsal locked plating increases fixation stability of unstable distal radius fractures after volar locked plating. However, its effect depends on the fracture pattern at the distal radius


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 66 - 66
1 Aug 2012
Singhal R Shakeel M Dheerendra S Ralte P Morapudi S Waseem M
Full Access

Background. Volar locking plates have revolutionised the treatment for distal radius fractures. The DVR (Depuy) plate was one of the earliest locking plates which were used and they provided fixed angle fixation. Recently, newer volar locking plates, such as the Aptus (Medartis), have been introduced to the market that allow the placement of independent distal subchondral variable-angle locking screws to better achieve targeted fracture fixation. The aim of our study was to compare the outcomes of DVR and Aptus volar locking plates in the treatment of distal radial fractures. Methods. Details of patients who had undergone open reduction and internal fixation of distal radii from October 2007 to September 2010 were retrieved from theatre records. 60 patients who had undergone stabilisation of distal radius fractures with either DVR (n=30) or Aptus (n=30) plate were included in the study. Results. Mean age of patients undergoing fixation using DVR plate was 56.6 years (n=30) with 22 females and 8 males. Fractures in this group included 20 type 23-C, three type 23-B and seven type 23-A. The patients were followed up for an average of 5.5 months (2-16 months). 3 patients underwent revision of fixation due to malunion (n=1), non-union (n=1) and failure of fixation (n=1). Four patients had reduced movements even after intensive physiotherapy necessitating removal of plate. Mean age of patients undergoing Aptus volar locking plate fixation was 56.38 years (n=30) with 21 females and 9 males. There were 27 type 23-C, two type 23-B and one type 23-A fractures according to AO classification. The patients were followed up for an average of 4.1 months (2-11 months). 2 patients developed complex regional pain syndrome (CRPS) and 1 patient underwent removal of screws due to late penetration of screws into the joint. Conclusion. Complex and unstable fractures of the distal radius can be optimally managed with volar locking plates. Both systems are user friendly. Aptus plates provide an additional advantage of flexibility in implant positioning and enhanced intra-fragmentary fixation compared to the DVR plate. In our study Aptus plates had lower secondary surgical procedures compared to DVR plates


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 582 - 582
1 Oct 2010
Sahu A Batra S Charalambos C Ravenscroft M
Full Access

Aim: Volar locking plates are increasingly used in the management of distal radius fractures. As with any new implant, understanding the rate and type of potential metalwork related complications is important. The aim of the study was to determine the type and rate of implant related complications that require further surgery when using volar locking plates in the management of distal radius fractures. Methods: In this study, we reviewed 114 distal radius fractures treated with volar locking plating. Patient records were reviewed with regards to demographics, operative details and post-operative outcomes. Fractures were classified as intra-articular or extra-articular. They were further classified using the AO classification system. Results: In our series, 12 cases (10%) underwent further surgery for metal work related complications mainly for screw protrusion into the radiocarpal joint following fracture collapse. Intra-articular fractures had a significantly greater complication rate as compared to extra-articular ones (11 vs. 1, P=0.04). There was no significant difference between the three plating systems used in this series with regards to need of further surgery (P=0.43). There was no significant difference between the grade of the operating surgeon with regards to metal work complications (P=0.9). There was no difference in rate of complications between males and females (P=0.27). Similarly there was no difference in metal work complications between patients aged less than 60 as compared to those aged more than 60 years (P=0.58). Our study has shown that volar locking plates may be associated with up to 10% rate of metalwork complications requiring revision surgery. The most common (8 out of 12) cause of re-operation was to remove the screws protruding into the radio-carpal joint. Discussion: Our results suggest that volar locking plates are associated with a high rate of metal work related complications requiring further surgery. In conclusion our study suggests that volar locking plates are associated with high reoperation rates for implant related complications. Intraoperative screening to ensure that there is no intrarticular penetration is also essential. We favour obtaining intra-operatively a lateral view with the forearm elevated 15–20 degrees to the horizontal plane to allow for the medial-lateral radial inclination and taking the posterior-anterior view at about 20 degrees to the horizontal plane to allow for the normal volar distal radial tilt. We feel that for a common fracture such as distal radial fractures an ideal implant should be easily reproducible with a low complication rate


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 525 - 526
1 Nov 2011
Chirpaz-Cerbat J Ruatti S
Full Access

Purpose of the study: Defective reduction and secondary displacement after osteosynthesis of distal radius fractures can compromise wrist function. Volar locking plates enable solid fixation which remains stable over time but section of the pronator quadrates necessary for the anterior approach raises the risks of destabilising the distal radioulnar joint and loss of pronation force. Our study was designed to evaluate recovery of grip, pronation and supination force after volar locking plate fixation. Material and methods: This was a prospective study of 29 fractures of the distal radius with dorsal displacement fixed with a volar locking plate in 28 patients (17 men, 11 women, mean age 48.75 years) from January 2007 to May 2008. The quality of the pronator quadrates suture was assessed at the end of the operation. The assessment included the classical parameters of wrist movement, the Herzberg and Dumontier score, radial slope and ulnar variance on the ap and lateral views of the wrist, and recovery of grip, pronation and supination force compared with the opposite side using an ambulatory device. Results: The pronator quadratus suture was considered solid in eight cases, precarious in seven. Complete suture was not possible in 14 cases. At mean follow-up of 10 months, patients had on average recovered 77% of the grip force, 74% of the pronation force, and 76% of supination force, compared with the opposite side. Complications included one defective reduction, one secondary displacement (by defective plate position), two dystrophy syndromes, and four posttrauma carpal tunnel syndromes. Discussion: The literature shows that volar plate fixation enables recovery of 74% to 84% of grip force. Few studies have examined the recovery of pronosupination and none have described results after osteosynthesis for fracture. Our study did not find that section of the pronator quadrates, a muscle difficult to suture, had a deleterious effect. Conclusion: Osteosynthesis using a volar locking plate for distal fractures of the radius remains a controversial issue. Study of recovery of the grip, pronation and supination force did not reveal any prejudice attributable to this technique


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 237 - 237
1 May 2009
Young D Feibel R Papp S Poitras P Ramachandran N
Full Access

There is theoretical concern that volar plating has a disadvantage in cantilever bending when axially loaded dorsal to the neutral axis. This has implications for postoperative rehabilitation protocols and overall outcomes related to maintenance of reduction. Most recent biomechanical studies have compared volar locking plates to traditional dorsal non-locked plates. The purpose of this study was to compare the biomechanical stability of volar and dorsal locking plate fixation in a model of dorsally unstable distal radius fractures. Fourteen synthetic composite radii (Pacific Research Laboratories, Vashon, WA) were used for this study. A dorsally unstable, extra-articular distal radius fracture was simulated by creating a dorsal wedge-shaped defect in the distal metaphysis. Half of the specimens were plated dorsally (n=7) while the other half were plated volarly (n=7) with 2.4mm distal radius locking T-plates (Synthes, Canada). Each specimen was loaded axially in five different positions: central (along the neutral axis of the radius) as well as dorsal, volar, radial and ulnar to the neutral axis using a MTS Sintech 1/G materials testing machine (MTS Systems, Eden Prairie, MN). The plated radii were loaded to 100 N in each position simulating physiological loading during normal range of motion. The main outcome measure was construct stiffness of the plate-bone system (slope of load-displacement curve) for all five loading positions. Construct stiffness with dorsal locking plates was seven times greater than volar locking plates when dorsally loaded (p < 0.001), 60% greater when centrally loaded (p = 0.055) and 35% greater when volarly loaded (p = 0.029). There was no significant difference in stiffness with any other loading configurations. The stability of dorsal locking plate fixation is superior to volar locking plate fixation in the setting of large dorsal defects in the distal radius. This is applicable to both fractures with dorsal comminution and dorsal opening-wedge distal radial osteotomies. Further clinical investigation is needed to compare functional outcomes and complication rates between modern dorsal and volar locking plate techniques


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 355 - 355
1 May 2009
McFadyen I Curwen C Field J
Full Access

Purpose: This study compares clinical and radiological outcomes of K-wire fixation with volar locking plate (i.e. fixed angle) fixation in unstable, dorsally angulated, distal radius fractures. Materials and methodology: Fifty four adult patients with an isolated, closed, unstable, dorsally angulated fracture without articular comminution were randomised to closed reduction and K-wire fixation (3 wires) or volar locking plate fixation. All were immobilised in a cast for six weeks and prescribed physiotherapy. Independent clinical and radiological assessment was performed at 3 and 6 months post injury, using the DASH and Gartland & Werley scoring systems. Results: Twenty-four patients were treated with a plate and thirty with K-wires. There were no complications in the plate group. There were 9 complications in the K-wire group. Three patients required re-operation (for malunion, median nerve compression, and retrieval of a migrated wire). Remaining complications included: 5 pin-site infections and 1 superficial radial nerve palsy. Plate fixation achieved statistically significant better radiological and functional results. Conclusion: Volar locking plate fixation achieves better radiological and functional results with fewer complications than K-wire fixation in unstable, dorsally angulated, distal radius fractures


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 38 - 38
1 Jul 2020
Lalone E Suh N Perrin M Badre A
Full Access

Distal radius fractures are the most common upper extremity injury, and are increasingly being treated surgically with pre-contoured volar-locking plates. These plates are favored for their low-profile template while allowing for rigid anatomic fixation of distal radius fractures. The geometry of the distal radius is extremely complex, and little evidence within the medical literature suggests that current implant designs are anatomically accurate. The main objective of this study is to determine if anatomic alignment of the distal radii corresponds accurately with modern volar-locking plate designs. Additionally, this study will examine sex-linked differences in morphology of the distal radius. Segmented CT models of ten female cadaver (mean age, 88.7 ± 4.57 years, range, 82 – 97) arms, and ten male cadaver (mean age, 86 ± 3.59 years, range, 81 – 91) arms were created. Micro CT models were obtained for the DePuy Synthes 2.4mm Extra-articular (EA) Volar Distal Radius Plate (4-hole and 5-hole head), and 2.4mm LCP Volar Column (VC) Distal Radius Plate (8-hole and 9-hole head). Plates were placed onto the distal radii models in a 3D visualization software by a fellowship-trained orthopaedic hand surgeon. The percent contact, volar cortical angle (VCA), border and overlap of the watershed line (WSL) were measured. Both sexes showed an increase in the average VCA measure from medial to lateral columns which was statistically significant. Female VCA ranged from 28 – 36 degrees, and 38 – 45 degrees for males. WSL overlap ranged from 0 – 34.7629% for all specimens without any statistical significance. The average border distance for females was 2.58571 mm, compared to 3.52411 mm for males, with EA plates having a larger border than VC plates. The border distances had statistically significant differences between the plate types, and was approaching significance between sexes. Lastly, a maximum percent contact of 21.966 % was observed in specimen F4 at a 0.3 mm threshold. No statistical significance between plate or sex populations was observed. This study investigated the incoherency between the volar cortical angle of the distal radius, and the pre-contoured angle of volar locking plates. It was hypothesized that if the VCA measures between plate and bone were unequal then there would be an increase in watershed line overlap, and decrease in percent contact between the surfaces. Our results agreed with literature, indicating that the VCA of bone was larger than that of the EA and VC pre-contoured plates examined in this study. With distal radius fracture incidences and prevalence on the rise for elderly female patients, it is a necessity that volar locking plates be re-designed to factor in anatomical features of individual patients with a particular focus on sex differences. New designs should focus on providing smaller head sizes that are more accurately tailored to the natural contours of the volar distal radius. It is recommended that future studies incorporate expertise from multiple surgeons to diversify and further understand plate placement strategies


The Bone & Joint Journal
Vol. 97-B, Issue 9 | Pages 1264 - 1270
1 Sep 2015
Karantana A Scammell BE Davis TRC Whynes DK

This study compares the cost-effectiveness of treating dorsally displaced distal radial fractures with a volar locking plate and percutaneous fixation. It was performed from the perspective of the National Health Service (NHS) using data from a single-centre randomised controlled trial. In total 130 patients (18 to 73 years of age) with a dorsally displaced distal radial fracture were randomised to treatment with either a volar locking plate (n = 66) or percutaneous fixation (n = 64). The methodology was according to National Institute for Health and Care Excellence guidance for technology appraisals. . There were no significant differences in quality of life scores between groups at any time point in the study. Both groups returned to baseline one year post-operatively. . NHS costs for the plate group were significantly higher (p < 0.001, 95% confidence interval 497 to 930). For an additional £713, fixation with a volar locking plate offered 0.0178 additional quality-adjusted life years in the year after surgery. The incremental cost-effectiveness ratio (ICER) for plate fixation relative to percutaneous fixation at list price was £40 068. When adjusting the prices of the implants for a 20% hospital discount, the ICER was £31 898. Patients who underwent plate fixation did not return to work earlier. We found no evidence to support the cost-effectiveness, from the perspective of the NHS, of fixation using a volar locking plate over percutaneous fixation for the operative treatment of a dorsally displaced radial fracture. Cite this article: Bone Joint J 2015;97-B:1264–70