Obesity is a known risk factor for developing osteoarthritis and is also associated with an increased risk of developing complications post total hip replacement (THR). This study investigated the association between obesity and the risk of undergoing THR in Australia. From July 2017 to June 2018 a National Health Survey was conducted by the Australian Bureau of Statistics to collect height and
Aims. Obesity is associated with an increased risk of hip osteoarthritis, resulting in an increased number of total hip arthroplasties (THAs) performed annually. This study examines the peri- and postoperative outcomes of morbidly obese (MO) patients (BMI ≥ 40 kg/m. 2. ) compared to healthy
Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body
Aims. It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA. Methods. In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound. Results. The median sound pressure (SP) of successful fixation at 0.5 to 1.0 kHz was higher than that of unsuccessful fixation (0.0694 (interquartile range (IQR) 0.04721 to 0.09576) vs 0.05425 (IQR 0.03047 to 0.06803), p < 0.001). The median SP of successful fixation at 3.5 to 4.0 kHz and 4.0 to 4.5 kHz was lower than that of unsuccessful fixation (0.0812 (IQR 0.05631 to 0.01161) vs 0.1233 (IQR 0.0730 to 0.1449), p < 0.001; and 0.0891 (IQR 0.0526 to 0.0891) vs 0.0885 (IQR 0.0716 to 0.1048); p < 0.001, respectively). There was a statistically significant positive relationship between body
Aims. Periacetabular osteotomy (PAO) is widely recognized as a demanding surgical procedure for acetabular reorientation. Reports about the learning curve have primarily focused on complication rates during the initial learning phase. Therefore, our aim was to assess the PAO learning curve from an analytical perspective by determining the number of PAOs required for the duration of surgery to plateau and the accuracy to improve. Methods. The study included 118 consecutive PAOs in 106 patients. Of these, 28 were male (23.7%) and 90 were female (76.3%). The primary endpoint was surgical time. Secondary outcome measures included radiological parameters. Cumulative summation analysis was used to determine changes in surgical duration. A multivariate linear regression model was used to identify independent factors influencing surgical time. Results. The learning curve in this series was 26 PAOs in a period of six months. After 26 PAO procedures, a significant drop in surgical time was observed and a plateau was also achieved. The mean duration of surgery during the learning curve was 103.8 minutes (SD 33.2), and 69.7 minutes (SD 18.6) thereafter (p < 0.001). Radiological correction of acetabular retroversion showed a significant improvement after having performed a total of 93 PAOs, including anteverting PAOs on 35 hips with a retroverted acetabular morphology (p = 0.005). Several factors were identified as independent variables influencing duration of surgery, including patient
Majority of ultra-high molecular
Since 1977 we did implant ceramic on ceramic THR in younger and active population. In 1991 we published (JBJS B N°4) data's in a consecutive group of patients under 50 years of age. What about the same patients for more than 30 years? Eighty-six hips in 75 patients, 41 males 34 females, mean age 43 (18 to 50), mean
To quantify the acetabular coverage of the femoral head, Lequesne's vertical-center-anterior edge (VCA) angle is used on the false profile view. Lateral coverage is determined by Wiberg's lateral-center-edge (LCE) angle on an ap pelvic view. The delimitation of the weightbearing area is defined by the end of the subchondral sclerosis line for both views. To our knowledge the exact anatomic location of the points used for measurement on the acetabular rim are not known. Six hips from three cadaver pelvises (3 male and 3 female) were investigated. The anterior and lateral points of interested were identified radiographically using fluoroscopy and marked with 1mm ceramic bullets. Standard false profile views and ap pelvic views in neutral inclination and rotation were taken to check the correct location of the ceramic bullets. A CT of each pelvis was made to locate the ceramic bullets and to define the exact anatomic location of the measurement points on the o'clock position. 6 o‘clock was defined as the midpoint between anteroinferior and the posteroinferior rim edges. Values were normalized for a right hip. The mean clockface location for the VCA was 1:33 (range, 1:15 to 1:40) and for the LCE 0:38 (range, 0:20 to 0:50). The LCEA is slightly anterior to the 12 o'clock position and remains useful to quantify the lateral coverage. Surprisingly, the point used for measuring the VCA is only about 30° (1h) anterior of the point used for measuring the LCEA. Its value for determining anterior cover has to be questioned. The discrepancy to other studies in the literature is because this study identifies and measures the end of the
Mechanical failure due to dislocation, fracture and acetabular wear as well as persistence of infection are the main complications associated with the use of hip spacers in the treatment of periprosthetic joint infections (PJI). We have developed a novel, custom-made spacer as part of two-stage septic hip replacement and present the two- to five-year results after reimplantation. We prospectively examined a total of 73 patients over our study period in whom our new spacer technique was used. The technique includes a dual mobility inlay and a cemented straight stem in combination with antibiotic-loaded PMMA bone cement which allows full
Osteoarthritis (OA) of the hip is the most common indication for total hip replacement (THR). Obesity is a risk factor for the development of OA and has recently resulted in patients requiring THRs at much younger ages to relieve pain at the joint capsule and restore mobility. However, the impact of obesity on THR mortality is not well understood. An updated systematic review was performed to identify whether an obese BMI should influence patient selection for surgery. Specifically, the impact of obesity on short-term mortality, long-term mortality, and peri- and post-operative complications was assessed with a particular focus on BMI classes. A comprehensive literature search of Ovid Medline and EMBASE in November 2022 identified relevant papers in accordance with PRISMA methodology. After removing duplicates, 2988 articles underwent strict inclusion and exclusion criteria, resulting in 12 papers for analysis. There was no statistically significant difference in mortality risk between obese and non-obese populations. Obesity was associated with a lower risk of short-term mortality than in the normal
The purposes of this study were to report the accuracy of stem anteversion for Exeter cemented stems with the Mako hip enhanced mode and to compare it to Accolade cementless stems. We reviewed the data of 25 hips in 20 patients who underwent THA through the posterior approach with Exeter stems and 25 hips in 19 patients with Accolade stems were matched for age, gender, height,
Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to
Aims. The localization of necrotic areas has been reported to impact the prognosis and treatment strategy for osteonecrosis of the femoral head (ONFH). Anteroposterior localization of the necrotic area after a femoral neck fracture (FNF) has not been properly investigated. We hypothesize that the change of the
Gluteal Tendinopathy is a poorly understood condition that predominantly affects post-menopausal women. It causes lateral hip pain, worse when lying on the affected side or when walking up a hill or stairs. It has been labelled ˜Greater Trochanteric Pain Syndrome” a name that recognises the lack of understanding of the condition. Surgical reconstruction of the gluteal cuff is well established and has been undertaken numerous times over the last 16 years by the senior author (AJL). However, the quality of collagen in the tendons can be very poor and this leads to compromised results. We present the results of gluteal cuff reconstruction combined with augmentation using a bioinductive implant. 14 patients (11 female, 3 male; mean age 74.2 ± 6.3 years) with significant symptoms secondary to gluteal tendinopathy that had failed conservative treatment (ultrasound guided injection and structured physiotherapy) underwent surgical reconstruction by the senior author using an open approach. In all cases the iliotibial band was lengthened and the trochanteric bursa excised. The gluteal cuff was reattached using Healicoil anchors (3–5×4.75mm anchors; single anchors but double row repair) and then augmented using a Regeneten patch. Patients were mobilised fully
Osteoporosis can cause significant disability and cost to health services globally. We aim to compare risk fractures for both osteoporosis and fractures at the L1-L4 vertebrae (LV) and the neck of femurs (NOFs) in patients referred for DEXA scan in the North-West of England. Data was obtained from 31546 patients referred for DEXA scan in the North-West of England between 2004 and 2011. Demographic data was retrospectively analysed using STATA, utilising chi-squared and t-tests. Logistical models were used to report odds ratios for risk factors included in the FRAX tool looking for differences between osteoporosis and fracture risk at the LV and NOFs. In a study involving 2530 cases of LV fractures and 1363 of NOF fractures, age was significantly linked to fractures and osteoporosis at both sites, with a higher risk of osteoporosis at NOFs compared to LV. Height provided protection against fractures and osteoporosis at both sites, with a more pronounced protective effect against osteoporosis at NOFs.
To investigate whether anterior pelvic plane-pelvic tilt (APP-PT) is associated with distinct hip pathomorphologies, we asked: (1) Is there a difference in APP-PT between symptomatic young patients eligible for joint preservation surgery and an asymptomatic control group? (2) Does APP-PT vary between distinct acetabular and femoral pathomorphologies? (3) Does APP-PT differ in symptomatic hips based on demographic factors?. IRB-approved, single-center, retrospective, case-control, comparative study in 388 symptomatic hips (357) patients (mean age 26 ± 2 years [range 23 to 29], 50% females) that presented to our tertiary center for joint preservation over a five year-period. Patients were allocated to 12 different morphologic subgroups. The overall study group was compared to a control group of 20 asymptomatic hips (20 patients). APP-PT was assessed in all patients based on AP pelvis X-rays using the validated HipRecon software. Values between overall and control group were compared using an independent samples t-test. Multiple regression analysis was performed to examine the influences of diagnoses and demographic factors on APP-PT. Minimal clinically important difference (MCID) of APP-PT was defined as >1 standard deviation. No significant differences in APP-PT between the control group and overall group (1.1 ± 3.0° [−4.9 to 5.9] vs 1.8 ± 3.4° [−6.9 to 13.2], p = 0.323) were observed. Acetabular retroversion and overcoverage groups showed higher APP-PT compared to the control group (both p < 0.05) and were the only diagnoses with significant influence on APP-PT in the stepwise multiple regression analysis. However, all observed differences were below the MCID. Demographic factors age, gender, height,
In total hip arthroplasty (THA), cementless cup without screw holes has the putative benefits of maximizing host bone contact and reducing osteolysis by eliminating channels to backside wear particles. However, supplemental trans-acetabular screws cannot be used. 74 hips in 60 patients receiving same model of cementless cup without screw holes (Depuy Duraloc 100 HA cup) from 6/1999 to 3/2003 were prospectively followed up. All patients were allowed to have immediate full
Aims. This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular
Aims. The aim of this study was to evaluate the performance of first-generation annealed highly cross-linked polyethylene (HXLPE) in cementless total hip arthroplasty (THA). Methods. We retrospectively evaluated 29 patients (35 hips) who underwent THA between December 2000 and February 2002. The survival rate was estimated using the Kaplan-Meier method. Hip joint function was evaluated using the Japanese Orthopaedic Association (JOA) score. Two-dimensional polyethylene wear was estimated using Martell’s Hip Analysis Suite. We calculated the wear rates between years 1 and 5, 5 and 10, 10 and 15, and 15 and final follow-up. Results. The mean follow-up period was 19.1 years (SD 0.6; 17.3 to 20.1). The 19-year overall survival rate with the end point of all-cause revision was 97.0% (95% confidence interval (CI) 91 to 100). The mean JOA score improved from 43.2 (SD 10.6; 30 to 76) before surgery to 90.2 (SD 6.4; 76 to 98) at the final follow-up (p < 0.001). There was no osteolysis or loosening of the acetabular or femoral components. The overall steady-state wear rate was 0.013 mm/year (SD 0.012). There was no hip with a steady-state wear rate of > 0.1 mm/year. There was no significant difference in wear rates for each period. We found no significant correlation between the wear rate and age, body
This study reports the ten-year polyethylene liner wear rates, incidence of osteolysis, clinical outcomes and complications of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular