Background and aim. Total hip replacement (THR) in
Guidelines for the use of preoperative blood tests for elective surgery were established. However, there is less evidence and no guidelines regarding using these tests when a
Shoulder arthritis in the
Introduction. Patient-specific instruments (PSI) and surgical-guiding templates are gaining popularity as a tool for enhancing surgical accuracy in the correction of oblique bone deformities Three-dimensional virtual surgical planning technology has advanced applications in the correction of deformities of long bones and enables the production of 3D stereolithographic models and PSI based upon a patient's specific deformity. We describe the implementation of this technology in
Total hip arthroplasty (THA) is effective, reproducible, and durable in the treatment of hip joint arthritis. While improvements in polyethylene materials have significantly reduced wear rates and osteolysis, aseptic loosening of implants remains one of the leading causes of revision THA. Additionally, fears of dislocation and instability have driven the increase in the utilization of larger diameter femoral heads in primary THA which can lead to increased wear when coupled with a polyethylene articulation. Finally, the increasing number of younger and active patients undergoing THA raises questions with regards to the ability of modern conventional bearings to provide durability and longevity beyond second and third decades following joint implantation. Ceramic-on-ceramic articulations are ideally suited for today's
Management of the
Background. Because of the long life expectancy of
90% of
Introduction. Total hip arthroplasty (THA) is becoming a common procedure because it dramatically relieves the patient's pain. Accordingly,
Acetabular fractures, particularly in the geriatric population are on the rise. A recent study indicated a 2.4-fold increase in the incidence of acetabular fractures, with the fastest rising age group, those older than the age of 55. Controversy exists as to the role and indications for total hip arthroplasty (THA), particularly in the acute setting. Three common scenarios require further evaluation and will be addressed. 1.) What is the role of THA in the acute setting for
Introduction:. Hard-on-hard bearings and surface replacement (SR) have been used in
Traditionally, arthritis is a disease which generally affects the elderly population. However, the incidence in
Introduction. Osteoarthritis (OA) represents a leading cause of disability and a growing burden on healthcare budgets. OA is particularly vexing for
The most appropriate bearings in
Cemented total hip arthroplasty (THA) in the younger patient has historically been associated with higher wear and revision rates. We carried out a retrospective study of a prospectively collected database of patients at Wrightington hospital undergoing cemented THA under 55 years of age to determine acetabular wear and revision rates. Between August 2005 and December 2021 a cohort of 110 patients, 56 males and 54 females, underwent Cemented Total Hip Replacement through a posterior approach. Mean age at operation was 50yrs (35–55). The mean follow up was 6 years 9 months (0–16 years). 3 patients were lost to follow-up. Of the remaining 107 patients, Conventional and cross lined polyethylene were used in 54 and 53 patients respectively. Ceramic heads were used in 102 patients. 22.225mm and 28mm heads were used in 60 and 47 patients respectively. Clinical outcomes were assessed by Merle d'Aubigne and Postel scores which showed significant functional improvement. Linear wear was measured on plain radiographs using TRAUMA CAD and cup loosening was assessed by classification of Hodgkinson et al. No cases were revised during the observed follow up period. The mean wear rate in conventional and crosslinked polyethylene cups were 2.31mm (0.1–4.6) and 1.02mm (0.1–2.6) respectively. Cemented THA with both conventional and crosslinked polyethylene provides excellent survival rates in adults under the age of 55 years and crosslinked polyethylene may further improve these results due to improved wear rates.Abstract
Treatment of the femoral head necrosis with severe extensive collapse in
Purpose. Unicompartmental Knee Arthroplasty (UKA) has been indicated for inactive elderly patients over 60, but for
Introduction:. Total hip arthroplasty has became one of the most successful standard procedures in the orthopaedic surgery. With a more frequent use in
The surgical treatment of
Ceramic-on-ceramic (COC) bearing surfaces have consistently demonstrated reliable clinical results with when coupled with appropriated designed femoral stems and acetabular shells. Ceramic bearing surfaces are highly wettable and display both boundary and hydrodynamic fluid-film lubrication modes, which lead to extremely low wear rates. Furthermore, COC bearing couples have been shown to exhibit virtually no risk of adverse biologic reaction and have not been associated with corrosion-induced adverse tissue reactions that occur with metal taper junctions, particularly head-neck taper junctions. The relative brittleness of ceramics initially was thought to be a major disadvantage; however, four decades of improvement in the manufacture of ceramics and rigorous proof testing has led an extremely low risk of fracture, perhaps lower than that for cross-linked polyethylene. More recently it has become increasing appreciated that nearly all revisions for squeaking have been restricted to specific designs and materials, including the use of a titanium elevated metal rim on the acetabular side, and more flexible femoral components made of a beta-titanium alloy (TMZF) which had thin necks and relative small tapers. Multiple clinical studies document excellent long-term survival of COC bearing couples in