Advertisement for orthosearch.org.uk
Results 1 - 20 of 416
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 6_Supple_B | Pages 116 - 122
1 Jun 2019
Whiteside LA Roy ME

Aims. The aims of this study were to assess the exposure and preservation of the abductor mechanism during primary total hip arthroplasty (THA) using the posterior approach, and to evaluate gluteus maximus transfer to restore abductor function of chronically avulsed gluteus medius and minimus. Patients and Methods. A total of 519 patients (525 hips) underwent primary THA using the posterior approach, between 2009 and 2013. The patients were reviewed preoperatively and at two and five years postoperatively. Three patients had mild acute laceration of the gluteus medius caused by retraction. A total of 54 patients had mild chronic damage to the tendon (not caused by exposure), which was repaired with sutures through drill holes in the greater trochanter. A total of 41 patients had severe damage with major avulsion of the gluteus medius and minimus muscles, which was repaired with sutures through bone and a gluteus maximus flap transfer to the greater trochanter. Results. Abductor strength was maintained in the normal hips, but lateral hip pain progressed significantly, five years postoperatively (p < 0.0001). In the 54 patients with mild abductor tendon damage treated with simple repair, lateral hip pain also increased significantly during follow-up (p = 0.002). In the 35 patients with severe avulsion but good muscle repaired using a gluteus maximus flap transfer, abductor function was restored. The six patients with complete avulsion and poor muscle did not regain strong abductor power, but lateral hip pain decreased. Conclusion. The posterior approach offered excellent exposure and preservation of the abductor mechanism during primary THA. Augmentation of the repair with a gluteus maximus flap provided stable reconstruction of the abductor muscles and seemed to restore function in the hips with functioning muscles. Cite this article: Bone Joint J 2019;101-B(6 Supple B):116–122


The Bone & Joint Journal
Vol. 95-B, Issue 3 | Pages 343 - 347
1 Mar 2013
Odak S Ivory J

Deficiency of the abductor mechanism is a well-recognised cause of pain and limping after total hip replacement (THR). This can be found incidentally at the time of surgery, or it may arise as a result of damage to the superior gluteal nerve intra-operatively, or after surgery owing to mechanical failure of the abductor muscle repair or its detachment from the greater trochanter. The incidence of abductor failure has been reported as high as 20% in some studies. The management of this condition remains a dilemma for the treating surgeon. We review the current state of knowledge concerning post-THR abductor deficiency, including the aetiology, diagnosis and management, and the outcomes of surgery for this condition. Cite this article: Bone Joint J 2013;95-B:343–7


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1050 - 1055
1 Aug 2015
Drexler M Abolghasemian M Kuzyk PR Dwyer T Kosashvili Y Backstein D Gross AE Safir O

This study reports the clinical outcome of reconstruction of deficient abductor muscles following revision total hip arthroplasty (THA), using a fresh–frozen allograft of the extensor mechanism of the knee. A retrospective analysis was conducted of 11 consecutive patients with a severe limp because of abductor deficiency which was confirmed on MRI scans. The mean age of the patients (three men and eight women) was 66.7 years (52 to 84), with a mean follow-up of 33 months (24 to 41). . Following surgery, two patients had no limp, seven had a mild limp, and two had a persistent severe limp (p = 0.004). The mean power of the abductors improved on the Medical Research Council scale from 2.15 to 3.8 (p < 0.001). Pre-operatively, all patients required a stick or walking frame; post-operatively, four patients were able to walk without an aid. Overall, nine patients had severe or moderate pain pre-operatively; ten patients had no or mild pain post-operatively. . At final review, the Harris hip score was good in five patients, fair in two and poor in four. . We conclude that using an extensor mechanism allograft is relatively effective in the treatment of chronic abductor deficiency of the hip after THA when techniques such as local tissue transfer are not possible. . Longer-term follow-up is necessary before the technique can be broadly applied. Cite this article: Bone Joint J 2015;97-B:1050–5


Bone & Joint Open
Vol. 3, Issue 10 | Pages 795 - 803
12 Oct 2022
Liechti EF Attinger MC Hecker A Kuonen K Michel A Klenke FM

Aims. Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. Methods. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement. Results. The mean FOs measured on AP hip and pelvis radiographs were 38.0 mm (SD 6.4) and 36.6 mm (SD 6.3) (p < 0.001), respectively. Radiological view had a smaller effect on FO measurement than inaccurate leg positioning. The model showed a non-linear relationship between projected FO and femoral neck orientation; at 30° external neck rotation (with reference to the detector plane), a true FO of 40 mm was underestimated by up to 20% (7.8 mm). With a neutral to mild external neck rotation (≤ 15°), the underestimation was less than 7% (2.7 mm). The effect of abduction and adduction was negligible. Conclusion. For routine THA templating, an AP pelvis radiograph remains the gold standard. Only patients with femoral neck malrotation > 15° on the AP pelvis view, e.g. due to external rotation contracture, should receive further imaging. Options include an additional AP hip view with elevation of the entire affected hip to align the femoral neck more parallel to the detector, or a CT scan in more severe cases. Cite this article: Bone Jt Open 2022;3(10):795–803


The Journal of Bone & Joint Surgery British Volume
Vol. 80-B, Issue 2 | Pages 284 - 287
1 Mar 1998
Giurea A Paternostro T Heinz-Peer G Kaider A Gottsauner-Wolf F

We compared two methods of reconstruction of the abductor mechanism in 15 patients after prosthetic replacement of the upper femur, to assess abductor strength and function. Six patients in group I had direct fixation of the gluteus medius tendon and a segment of the original bone to the prosthesis. Nine patients in group 2 had the abductor tendon fixed to the iliotibial band. We assessed clinical function, isometric muscle strength and muscle cross-sectional area for each patient. The patients in group 1 had better clinical and functional results (p = 0.059), with average peak torques for hip abduction of 92% of that in the non-operated leg in group 1, and of 57% in group 2. Group 1 had a mean muscle cross-sectional area of 69% and a mean value of strength per cross-sectional area of 134% when compared with the control side. The respective values for group 2 were 52% and 91%. Direct fixation of the abductor muscles to the prostheses gave improved function and higher isometric abductor muscle force


Bone & Joint Open
Vol. 2, Issue 12 | Pages 1067 - 1074
1 Dec 2021
El-Bakoury A Khedr W Williams M Eid Y Hammad AS

Aims. After failed acetabular fractures, total hip arthroplasty (THA) is a challenging procedure and considered the gold standard treatment. The complexity of the procedure depends on the fracture pattern and the initial fracture management. This study’s primary aim was to evaluate patient-reported outcome measures (PROMs) for patients who underwent delayed uncemented acetabular THA after acetabular fractures. The secondary aims were to assess the radiological outcome and the incidence of the associated complications in those patients. Methods. A total of 40 patients underwent cementless acetabular THA following failed treatment of acetabular fractures. The postoperative clinical and radiological outcomes were evaluated for all the cohort. Results. The median (interquartile range (IQR)) Oxford Hip Score (OHS) improved significantly from 9.5 (7 to 11.5), (95% confidence interval (CI) (8 to 10.6)) to 40 (39 to 44), (95% CI (40 to 43)) postoperatively at the latest follow-up (p < 0.001). It was worth noting that the initial acetabular fracture type (simple vs complex), previous acetabular treatment (ORIF vs conservative), fracture union, and restoration of anatomical centre of rotation (COR) did not affect the final OHS. The reconstructed centre of rotation (COR) was restored in 29 (72.5%) patients. The mean abduction angle in whom acetabular fractures were managed conservatively was statistically significantly higher than the surgically treated patients 42.6° (SD 7.4) vs 38° (SD 5.6)) (p = 0.032). We did not have any case of acetabular or femoral loosening at the time of the last follow-up. We had two patients with successful two-stage revision for infection with overall eight-year survival rate was 95.2% (95% CI 86.6% to 100%) with revision for any reason at a median (IQR) duration of follow-up 50 months (16 to 87) months following THA. Conclusion. Delayed cementless acetabular THA in patients with previous failed acetabular fracture treatments produces good clinical outcomes (PROMS) with excellent survivorship, despite the technically demanding nature of the procedure. The initial fracture treatment does not influence the outcome of delayed THA. In selected cases of acetabular fractures (either nondisplaced or with secondary congruency), the initial nonoperative treatment neither resulted in large acetabular defects nor required additional acetabular reconstruction at the time of THA. Cite this article: Bone Jt Open 2021;2(12):1067–1074


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 32 - 32
19 Aug 2024
Caplash G Caplash Y Copson D Thewlis D Ehrlich A Solomon LB Ramasamy B
Full Access

Few surgical techniques to reconstruct the abductor mechanism of the hip have been reported, with outcomes reported only from case reports and small case series from the centres that described the techniques. As in many of our revision THA patients the gluteus maximus was affected by previous repeat posterior approaches, we opted to reconstruct the abductor mechanism using a vastus lateralis to gluteus medius transfer. We report the results of such reconstructions in seven patients, mean age 66 (range, 53–77), five females, presenting with severe abductor deficiency (MRC grade 1–2). Five patients had previous revision THA, two with a proximal femoral replacement, one patient had a primary THA after a failed malunited trochanteric fracture, and one patient had a native hip with idiopathic fatty infiltration of glutei of >90%. All patients had instrumented gait analysis, and surface electromyography (EMG) of the glutei, TFL, and vastus muscles simultaneously before surgery and at each post-op follow-up. Postoperatively, patients were allowed to weight bear as tolerated and were requested to wear an abduction brace for the first six weeks after surgery to protect the transfer. All patients improved after surgery and reached an abductor power of 3 or more. All patients walked without support six months after surgery and were satisfied with the result. Abductor function continued to improve beyond one year of follow-up, and some patients reached an abductor power of 5. EMG demonstrated that the transferred vastus lateralis started firing synchronously with gluteus medius after three months post-surgery, suggesting adaptation to its new function. No knee extension weakness was recorded. One patient complained of lateral thigh numbness and was dissatisfied with the cosmetic look of her thigh after surgery. Our preliminary results are encouraging and comparable with those achieved by the originators of the technique


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 24 - 24
23 Jun 2023
Byrd JWT Jones KS Bardowski EA
Full Access

Partial thickness abductor tendon tears are a significant source of recalcitrant laterally based hip pain. For those that fail conservative treatment, the results of endoscopic repair are highly successful with minimal morbidity. The principal burden is the protracted rehabilitation that is necessary as part of the recovery process. There is a wide gap between failed conservative treatment and successful surgical repair. It is hypothesized that a non-repair surgical strategy, such as a bioinducitve patch, could significantly reduce the burden associated recovery from a formal repair. Thus, the purpose of this study is to report the preliminary results of this treatment strategy. Symptomatic partial thickness abductor tendon tears are treated conservatively, including activity modification, supervised physical therapy and ultrasound guided corticosteroid injections. Beginning in January 2022, patients undergoing hip arthroscopy for intraarticular pathology who also had persistently symptomatic partial thickness abductor tendon tears, were treated with adjunct placement of a bioinducitve (Regeneten) patch over the tendon lesion from the peritrochanteric space. The postop rehab protocol is dictated by the intraarticular procedure performed. All patients are prospectively assessed with a modified Harris Hip Score (mHHS) and iHOT and the tendon healing response examined by ultrasound. Early outcomes will be presented on nine consecutive cases. Conclusions - Will be summarized based on the preliminary outcomes to be reported


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 10 - 10
23 Jun 2023
Apinyankul R Hong C Hwang K Koltsov JCB Amanatullah DF Huddleston JI Maloney WJ Goodman SB
Full Access

Instability is a common indication for revision total hip arthroplasty (THA). However, even after the initial revision, some patients continue to have recurrent dislocations. This study investigates those at risk for recurrent dislocation after revision THA for instability at a single institution. Between 2009 and 2019, 163 patients underwent revision THA for instability at a single institution. Thirty-three of these patients required re-revision THA due to recurrent dislocation. Cox proportional hazard models with death as a competing event were used to analyze risk factors, including prosthesis sizing and alignment. Paired t-tests or Wilcoxon signed rank tests were used to assess patient outcomes (Veterans RAND 12 (VR-12) physical score, VR-12 mental score, Harris Hip Score, and hip disability and osteoarthritis outcome score for joint replacement). Duration of follow-up until either re-revision or final follow-up was a mean of 45.3 ± 38.2 months. The 1-year cumulative incidence for recurrent dislocation after revision was 8.7%, which increased to 19.6% at 5 years and 32.9% at 10 years postoperatively. In the multivariable analysis, high ASA score [HR 2.71], being underweight (BMI<18 kg/m. 2. ) [HR 36.26] or overweight/obese (BMI>25 kg/m. 2. ) [HR 4.31], use of specialized liners [HR 5.51–10.71], lumbopelvic stiffness [HR 6.29], and postoperative abductor weakness [HR 7.20] were significant risk factors for recurrent dislocation. Increasing the cup size decreased the dislocation risk [HR 0.89]. The dual mobility construct did not affect the risk for recurrent dislocation in univariate or multivariable analyses. VR-12 physical and HHS (pain and function) scores improved postoperatively at midterm. Patients requiring revision THA for instability are at risk for recurrent dislocation. Higher ASA scores, abnormal BMI, use of special liners, lumbopelvic stiffness, and postoperative abductor weakness are significant risk factors for re-dislocation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 44 - 44
23 Jun 2023
Scholz J Perka C Hipfl C
Full Access

Dual-mobility (DM) bearings are effective to mitigate dislocation in revision total hip arthroplasty (THA). However, data on its use for treating dislocation is scarce. Aim of this study was to compare DM bearings, standard bearings and constrained liner (CL) in revision THA for recurrent dislocation and to identify risk factors for re-dislocation. We reviewed 100 consecutive revision THAs performed for dislocation from 2012 and 2019. 45 hips (45%) received a DM construct, while 44 hips (44%) and 11 hips (11%) had a standard bearing and CL, respectively. Rates of re-dislocation, re-revision for dislocation and overall re-revision were compared. Radiographs were assessed for cup positioning, restoration of centre of rotation, leg length and offset. Risk factors for re-dislocation were determined by cox regression analysis. Modified Harris hip scores (mHHS) were calculated. Mean follow-up was 53 months (1 to 103). DM constructs were used more frequently in elderly patients (p=0.011) and hips with abductor deficiency (p< 0.001). The re-dislocation rate was 11.1% for DM bearings compared with 15.9% for standard bearings and 18.2% for CL (p=0.732). Revision-free survival for DM constructs was 83% (95% CI 0.77 – 0.90) compared to 75% (95% CI 0.68 – 0.82) for standard articulations and 71% (95% CI 0.56 – 0.85) for CL (p=0.455). Younger age (HR 0.91; p=0.020), lower comorbidity (HR 0.42; p=0.031), smaller heads (HR 0.80; p=0.041) and cup retention (HR 8.23; p=0.022) were associated with re-dislocation. Radiological analysis did not reveal a relationship between restoration of hip geometry and re-dislocation. mHHS significantly improved from 43.8 points to 65.7 points (p<0.001) with no differences among bearing types. Our findings suggest that DM bearings do not sufficiently prevent dislocation in revision THA for recurrent dislocation. Reconstruction of the abductor complex may play a key role to reduce the burden in these high-risk patients


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 352 - 358
1 Apr 2024
Wilson JM Trousdale RT Bedard NA Lewallen DG Berry DJ Abdel MP

Aims. Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell. The goal of this study was to describe the implant survival, complications, and radiological outcomes of this construct. Methods. We identified 64 patients (65 hips) who had a single-design cemented DM cup cemented into an uncemented acetabular shell during revision THA between 2018 and 2020 at our institution. Cups were cemented into either uncemented cups designed for liner cementing (n = 48; 74%) or retained (n = 17; 26%) acetabular components. Median outer head diameter was 42 mm. Mean age was 69 years (SD 11), mean BMI was 32 kg/m. 2. (SD 8), and 52% (n = 34) were female. Survival was assessed using Kaplan-Meier methods. Mean follow-up was two years (SD 0.97). Results. There were nine cemented DM cup revisions: three for periprosthetic joint infection, three for acetabular aseptic loosening from bone, two for dislocation, and one for a broken cup-cage construct. The two-year survivals free of aseptic DM revision and dislocation were both 92%. There were five postoperative dislocations, all in patients with prior dislocation or abductor deficiency. On radiological review, the DM cup remained well-fixed at the cemented interface in all but one case. Conclusion. While dislocation was not eliminated in this series of complex revision THAs, this technique allowed for maximization of femoral head diameter and optimization of effective acetabular component position during cementing. Of note, there was only one failure at the cemented interface. Cite this article: Bone Joint J 2024;106-B(4):352–358


Bone & Joint Open
Vol. 2, Issue 6 | Pages 365 - 370
1 Jun 2021
Kolodychuk N Su E Alexiades MM Ren R Ojard C Waddell BS

Aims. Traditionally, acetabular component insertion during total hip arthroplasty (THA) is visually assisted in the posterior approach and fluoroscopically assisted in the anterior approach. The present study examined the accuracy of a new surgeon during anterior (NSA) and posterior (NSP) THA using robotic arm-assisted technology compared to two experienced surgeons using traditional methods. Methods. Prospectively collected data was reviewed for 120 patients at two institutions. Data were collected on the first 30 anterior approach and the first 30 posterior approach surgeries performed by a newly graduated arthroplasty surgeon (all using robotic arm-assisted technology) and was compared to standard THA by an experienced anterior (SSA) and posterior surgeon (SSP). Acetabular component inclination, version, and leg length were calculated postoperatively and differences calculated based on postoperative film measurement. Results. Demographic data were similar between groups with the exception of BMI being lower in the NSA group (27.98 vs 25.2; p = 0.005). Operating time and total time in operating room (TTOR) was lower in the SSA (p < 0.001) and TTOR was higher in the NSP group (p = 0.014). Planned versus postoperative leg length discrepancy were similar among both anterior and posterior surgeries (p > 0.104). Planned versus postoperative abduction and anteversion were similar among the NSA and SSA (p > 0.425), whereas planned versus postoperative abduction and anteversion were lower in the NSP (p < 0.001). Outliers > 10 mm from planned leg length were present in one case of the SSP and NSP, with none in the anterior groups. There were no outliers > 10° in anterior or posterior for abduction in all surgeons. The SSP had six outliers > 10° in anteversion while the NSP had none (p = 0.004); the SSA had no outliers for anteversion while the NSA had one (p = 0.500). Conclusion. Robotic arm-assisted technology allowed a newly trained surgeon to produce similarly accurate results and outcomes as experienced surgeons in anterior and posterior hip arthroplasty. Cite this article: Bone Jt Open 2021;2(6):365–370


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1459 - 1463
1 Nov 2019
Enishi T Yagi H Higuchi T Takeuchi M Sato R Yoshioka S Nakamura M Nakano S

Aims. Rotational acetabular osteotomy (RAO) is an effective joint-preserving surgical treatment for acetabular dysplasia. The purpose of this study was to investigate changes in muscle strength, gait speed, and clinical outcome in the operated hip after RAO over a one-year period using a standard protocol for rehabilitation. Patients and Methods. A total of 57 patients underwent RAO for acetabular dysplasia. Changes in muscle strength of the operated hip, 10 m gait speed, Japanese Orthopaedic Association (JOA) hip score, and factors correlated with hip muscle strength after RAO were retrospectively analyzed. Results. Three months postoperatively, the strength of the operated hip in flexion and abduction and gait speed had decreased from their preoperative levels. After six months, the strength of flexion and abduction had recovered to their preoperative level, as had gait speed. At one-year follow-up, significant improvements were seen in the strength of hip abduction and gait speed, but muscle strength in hip flexion remained at the preoperative level. The mean JOA score for hip function was 91.4 (51 to 100)) at one-year follow-up. Body mass index (BMI) showed a negative correlation with both strength of hip flexion (r = -0.4203) and abduction (r = -0.4589) one year after RAO. Although weak negative correlations were detected between strength of hip flexion one year after surgery and age (r = -0.2755) and centre-edge (CE) angle (r = -0.2989), no correlation was found between the strength of abduction and age and radiological evaluations of CE angle and acetabular roof obliquity (ARO). Conclusion. Hip muscle strength and gait speed had recovered to their preoperative levels six months after RAO. The clinical outcome at one year was excellent, although the strength of hip flexion did not improve to the same degree as that of hip abduction and gait speed. A higher BMI may result in poorer recovery of hip muscle strength after RAO. Radiologically, acetabular coverage did not affect the recovery of hip muscle strength at one year’s follow-up. A more intensive rehabilitation programme may improve this. Cite this article: Bone Joint J 2019;101-B:1459–1463


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 31 - 31
1 Oct 2019
Whiteside LA
Full Access

Introduction. The results of repair and reconstruction of lesions found in the abductor muscles and tendons during posterior approach to primary total hip arthroplasty (THA) were reported in 2018. During the course of this series it became apparent that the extent of damage in the abductor tendons and muscles usually was obscured by the hypertrophic greater trochanteric bursa, especially the deep layer adherent to the greater trochanter and abductor muscles. The purpose of this study was to evaluate the surgeon's ability to see these lesions during standard posterior approach, and also to describe the dissection necessary to fully expose them. Patients and Methods. A total of 525 patients (525 hips) underwent primary THA through posterior approach between 2009 and 2013. Fifty-four patients had mild chronic damage to the tendon. Forty-one patients had severe damage with major avulsion of the gluteus medius and minimus muscles. Results. None of the hips with normal abductor muscle structure had a dense trochanteric bursa to obscure the abductor attachment to bone, but in 35 hips (85.3%) with significant abductor tendon avulsion, the lesions in the tendons were hidden from view until the greater trochanteric bursa was dissected. Splitting the deep layer of the trochanteric bursa in line with the fibers of the abductor muscles was necessary to reveal avulsion of the tendons from the edge of the greater trochanter. Only six hips (14.6%) had abductor tendon avulsion from the greater trochanter that could be seen without removing the trochanteric bursa tissue. Conclusion. The posterior approach offered excellent exposure of the abductor mechanism during primary THA, but the avulsion defects in the gluteus medius and minimus muscles remained obscured until the outer layer of the greater trochanteric bursa was completely removed and the deep fibrous layer was dissected adequately to expose the tendon attachment to bone. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 72 - 72
19 Aug 2024
Chen X
Full Access

Sequelae of Legg-Calve -Perthes disease (LCPD) and treatment of developmental dysplasia of the hip (DDH) can present a coxa breva or coxa magna deformity, sometimes associated with coxa vara. This unique deformity decreases the efficiency of the abductor mechanism, causing a Trendelenburg gait and hip pain, leg length discrepancy and leads to intra- and extra-articular impingement, and eventually osteoarthritis. Several surgical techniques have been advocated to treat this kind deformity, such as great trochanter transfer, relative femoral neck lengthening. We evaluated primary results of true femoral neck-lengthening osteotomy (TFNLO) in combination with periacetabular osteotomy (PAO) for treatment of Coxa Breva through surgical hip dislocation (SHD). Fourteen patients with Coxa Breva received true femoral neck lengthening osteotomy in combination of PAO through SHD between March 2020 and October 2023. Ten patients with minimum 1 year followed-up were retrospectively reviewed clinically and radiographically. Eight patients had Perthes disease, 2 had DDH received closed reduction and fixation during childhood. The mean age at surgery was 16 years (range, 12 to 31 years). Clinical findings, radiographic analyses including the change in horizontal femoral offset and the leg length discrepancy as well as complications were assessed. Horizontal femoral offset improved 19.5mm(6–28mm). Limb length increase 16.8mm(11–30mm). Mean HHS increased from 80.6(66–91) to 91.8(88–96). Complication: screw broken in 1(no need operation). Asymptomatic fibrous union of the great trochanter was found in 1. No infection and joint space narrow as well as nerve palsy happened. TFNLO combined with PAO can be effective for the treatment of patients with Coxa breva. But long term follow up is warranted


There is still no clear consensus regarding which cup position might provide better functional performance for developmental dysplasia of the hip (DDH). This study aimed to evaluated the feasibility and efficacy of acetabular mirroring reconstruction for DDH in total hip arthroplasty (THA). The study reviewed 96 patients (96 hips) with unilateral Crowe type-II/III DDH undergoing either visualized navigation-assisted mirroring reconstruction with augment according to the rotation center and biomechanical structure of the contralateral normal hips (Mirroring group, 51 hips) or high hip center reconstruction (HHC group, 45 hips) in THA from 2020 to 2023. The functional and radiographic results were analyzed between the groups during a mean follow-up period of 27.5 and 28.9 months (a minimum follow-up of 12 months). The Harris hip score at the last follow-up significantly improved in both groups, while it was significantly higher in the mirroring group (P<0.001). In the HHC group, the rotation center height and greater trochanter height were significantly increased in the affected hip (P<0.001; P<0.001) and the abductor lever arm was significantly decreased in the affected hip compared to that in the contralateral normal hip (P<0.001), whereas in the mirroring group no significant statistical differences were observed between two sides. The limping occurred in 7 patients (13.7%) in the mirroring group and 14 patients (31.1%) in the HHC group (P=0.040). A multiple logistic regression demonstrated mirroring reconstruction could reduce the incidence of postoperative limping (P=0.020). Both mirroring and HHC reconstruction could improve the functional performance of THA, whereas mirroring reconstruction could offer superior biomechanical results and gait improvement as compared with HHC reconstruction, meeting the higher requirements of functional recovery


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 46 - 46
23 Jun 2023
Mallett K Guarin S Sierra RJ
Full Access

Dual mobility (DM) components are increasingly used to prevent and treat dislocation after total hip arthroplasty (THA). Intraprosthetic dissociation (IPD) is a known rare complication of these implants and has reportedly decreased with modern implants. The purpose of this paper is to report the diagnosis and treatment of modern DM IPD. 1453 DM components were implanted between 2010 and 2021. 695 in primary and 758 in revision THA. 49 hips sustained a dislocation of the large head and 5 sustained an IPD at presentation. 6 additional IPD occurred at the time of reduction of large head. The average age was 64, 54% were female and the mean follow-up was three years. Of the 11 IPD, 8 had a history of instability, 5 had abductor insufficiency, 4 had prior lumbar fusion, and 3 were conversions from fracture. The overall IPD incidence was 0.76%. Ten of the 11 DM IPD were missed at initial presentation or at the time of reduction, and all were discharged with presumed reduction. The mean time from IPD to surgical treatment was 3 weeks. One patient died with an IPD at 5 months. A DM head was reimplanted in six, two underwent revision of the acetabular component with exchange of DM head, and four were revised to a constrained liner. The re-revision rate was 55% at a mean 1.8 years. None of the patients who underwent cup revision required subsequent re-revision while half of the constrained liners and exchange of DM heads required re-revision. The overall rate of DM dislocation or IPD is low. It is critical to identify an IPD on radiographs as it was almost universally missed at presentation or when it occurred iatrogenically. For patients presenting with IPD, the surgeon should consider acetabular revision and conversion to a constrained liner or a larger DM, with special attention to removing impinging structures that could increase the risk of re-dislocation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 57 - 57
19 Aug 2024
Jones SA Davies O
Full Access

Dislocation following revision THA remains a leading cause of failure. Integrity of the abductor muscles is a major contributor to stability. Large diameter heads (LDH), Dual Mobility (DM) and Constrained Acetabular Liners (CAL) are enhanced stability options but the indication for these choices remains unclear. We assessed an algorithm based on Gluteus Medius (GM) deficiency to determine bearing selection. Default choice with no GM damage was a LDH. GM deficiency with posterior muscle intact received DM and CAL for GM complete deficiency with loss of posterior muscle. Consecutive revision THA series followed to determine dislocation, all-cause re-revision and Oxford Hip Score (OHS). 311 revision THA with mean age 70 years (32–95). At a mean follow-up of 4.8 years overall dislocation rate 4.1% (95%CI 2.4–7.0) and survivorship free of re-revision 94.2% (95%CI 96.3–91.0). Outcomes:. Group 1 - LDH (36 & 40mm) n=164 / 4 dislocations / 7 re-revisions. Group 2 - DM n=73 / 3 dislocations / 4 re-revisions. Group 3 - CAL n=58 / 5 dislocations / 7 re-revisions. Group 4 - Other (28 & 32mm) n=16 / 1 dislocation / no re-revisions. Mean pre-op OHS: 19.6 (2–47) and mean post-op OHS: 33.9 (4–48). Kaplan-Meier analysis at 60 months dislocation-free survival was 96.1% (95% CI: 93.0–97.8). There was no difference between survival distributions comparing bearing choice (p=0.46). Decision making tools to guide selection are limited and in addition soft tissue deficiency has been poorly defined. The posterior vertical fibres of GM have the greatest lateral stabiliser effect on the hip. The algorithm we have used clearly defined indication & implant selection. We believe our outcomes support the use of an enhanced stability bearing selection algorithm


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 28 - 28
23 Jun 2023
Massè A Giachino M Audisio A Donis A Secco D Turchetto L Limone B Via RG Aprato A
Full Access

Ganz's studies made it possible to address joint deformities on both femoral and acetabular side brought by the Legg-Calvè-Perthes disease (LCPD). Femoral head reduction osteotomy (FHRO) was developed to improve joint congruency along with periacetabular osteotomy (PAO). The purpose of this study is to show the clinical and morphologic outcomes of the technique, and an implemented planning approach. From 2015 to 2023, 13 FHROs were performed on 11 patients for LCPD, in two centers. 11 of 13 hips had an associated PAO. A specific CT and MRI-based protocol for virtual simulation of the corrections was developed. Outcomes were assessed with radiographic parameters (sphericity index, extrusion index, integrity of the Shenton's line, LCE angle, Tonnis angle, CCD angle) and clinical parameters (ROM, VAS, Merle d'Aubigné-Postel score, modified-HHS, EQ5D-5L). Early and late complications were reported. The mean follow-up was 40 months. The mean age at surgery was 11,4 years. No major complications were recorded. One patient required a total hip arthroplasty. Femoral Head Sphericity increased from 45% to 70% (p < 0,001); LCE angle from 18° to 42,8° (p < 0,001); extrusion Index from 36,6 to 8 (p < 0,001); Tonnis Angle from 14,4° to 6,2° (p = 0.1); CCD Angle from 131,7 to 136,5° (p < 0,023). The VAS score improved from 3,25 to 0,75,(p = 0.06); Merle d'Aubigné-Postel score from 14.75 to 16 (p = 0,1); Modified-HHS from 65,6 to 89,05 (p = 0,02). The EQ 5D 5L showed significant improvements. ROM increased especially in abduction and extra-rotation. FHRO associated with periacetabular procedures is a safe technique that showed improved functional, clinical and morphologic outcomes in LCPD. The newly introduced simulation and planning algorithm may help to further refine the technique


Bone & Joint Open
Vol. 4, Issue 11 | Pages 853 - 858
10 Nov 2023
Subbiah Ponniah H Logishetty K Edwards TC Singer GC

Aims. Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods. A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results. A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion. The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence ‘5% at ten years’ threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing. Cite this article: Bone Jt Open 2023;4(11):853–858