This study compared the effect of a computer-assisted and a traditional surgical technique on the kinematics of the glenohumeral joint during passive
Introduction. Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty. Method. In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the
Introduction. Assessment of the humeral head translation with respect to the glenoid joint, termed humeral head migration (HHM), is crucial in total shoulder arthroplasty pre-operative planning. Its assessment informs current classification systems for shoulder osteoarthritis as well as the evaluation of surgical correction. In current clinical practice, HHM assessment relies on computed-tomography (CT) imaging. However, the associated supine position might undermine its functional relevance as it does not reflect the weight-bearing condition with active muscle engagement associated with the upright standing position of most daily activities. Therefore, we assessed to what extent HHM in a supine position is associated with HHM in a range of functional arm positions. Method. 26 shoulder osteoarthritis patients and 12 healthy volunteers were recruited. 3D shapes of the humerus and scapula were reconstructed from their respective CT scans using an image processing software. 3. , and their CT-scan-based HHMs were measured. Furthermore, all subjects underwent low-dose biplanar radiography . 4. in four quasi-static functional arm positions while standing: relaxed standing, followed by 45 degrees of shoulder extension, flexion, and
This study examined pre-operative measures to predict post-operative biomechanical outcomes in total knee arthroplasty (TKA) patients. Twenty-eight patients (female=12/male=16, age=63.6±6.9, BMI=29.9±7.4 kg/m2) with knee osteoarthritis scheduled to undergo TKA were included. All surgeries were performed by the same surgeon (GD) with a subvastus approach. Patients visited the gait lab within one-month prior to surgery and 12 months following surgery. At the gait lab, patients completed the knee injury and osteoarthritis outcome score (KOOS), a timed up and go (TUG), maximum knee flexion and extension strength evaluation, and a walking task. Variables of interest included the five KOOS sub-scores, TUG time, maximum knee flexion and extension strength normalized to body weight, walking speed, and peak knee biomechanics variables (flexion angle,
In an attempt to alleviate symptoms of the disease, patients with knee osteoarthrosis (KOA) frequently alter their gait patterns. Understanding the underlying pathomechanics and identifying KOA phenotypes is essential for improving treatments. We aimed to investigate altered kinematics in patients with KOA to identify subgroups. Sixty-six patients with symptomatic KOA scheduled for total knee arthroplasty and 12 age-matched healthy volunteers with asymptomatic knees were included. We used k-means to separate the patients based on dynamic radiostereometric assessed knee kinematics. Ligament lesions, KOA score, and clinical outcome were assessed by magnetic resonance imaging, radiographs, and patient reported outcome measures, respectively. We identified four clusters that were supported by clinical characteristics. Compared with the healthy group; The flexion group (n=20): revealed increased flexion, greater adduction, and joint narrowing and consisted primarily of patients with medial KOA. The
The periclavicular space is a conduit for the brachial plexus and subclavian-axillary vascular system. Changes in its shape/form generated by alteration in the anatomy of its bounding structures, e.g. clavicle malunion, cause distortion of the containing structures, particularly during arm motion, leading to syndromes of thoracic outlet stenosis etc., or alterations of scapular posture with potential reduction in shoulder function. Aim of this study was developing an in vitro methodology for systematic and repeatable measurements of the clinically poorly characterized periclavicular space during arm motion using CT-imaging and computer-aided 3D-methodologies. A radiolucent frame, mountable to the CT-table, was constructed to fix an upper torso in an upright position with the shoulder joint lying in the isocentre. The centrally osteotomized humerus is fixed to a semi-circular bracket mounted centrally at the end of the frame. All arm movements (ante-/retroversion,
Introduction. Supraspinatus tears comprise most rotator cuff injuries, the leading cause of shoulder pain and an increasing problem with ageing populations. Surgical repair of considerable or persistent damages is customary, although not invariably successful. Tissue engineering presents a promising alternative to generate functional tissue constructs with improved healing capacities. This study explores tendon tissue constructs’ culture in a platform providing physiological mechanical stimulation and reports on the effect of different loading regimes on the viability of human tendon cells. Method. Porcine decellularized tendon scaffolds were fixed into flexible, self-contained bioreactor chambers, seeded with human tenocytes, allocated in triplicates to either static control, low (15±0.8Newtons [N]), medium (26±0.5N), or high (49±2.1N)-force-regime groups, connected to a perfusion system and cultured under standard conditions. A humanoid robotic arm provided 30-minute adduction/
Introduction. Supraspinatus and infraspinatus tears (Massive Rotator Cuff Tear- MRCT) cause compensatory activation of the teres minor (TM) and subscapularis (SubS) to maintain humeral head alignment. This study measures force changes in TM and SubS using a dynamic shoulder testing setup. We hypothesize that combining superior capsule reconstruction (SCR) and lower trapezius tendon (LTT) transfer will correct rotator cuff forces. Methods. Eight fresh-frozen human shoulder specimens from donors aged 55-75 (mean = 63.75 years), balanced for gender, averaging 219.5 lbs, were used. Rotator cuff and deltoid tendons were connected to force sensors through a pulley system, with the deltoid linked to a servohydraulic motor for dynamic force measurement. The system allowed unrestricted humeral
The risk of falls in patients undergoing orthopedic procedures is particularly significant in terms of health and socioeconomic effects. The literature analyzed closely this risk following procedures performed on the lower limb, but the implications following procedures on the upper limb remain to be investigated. Interestingly, it is not clear whether the increased risk of falling in patients undergoing shoulder surgery is due to preexisting risk factors at surgery or postoperative risk factors, such as anesthesiologic effects, opioid medications used for pain control, or brace use. Only one prospective study examined gait and fall risk in patients using a shoulder
The HIPGEN study funded under EU Horizon 2020 (Grant 7792939) has the aim to investigate the potential of the first regenerative cell therapy for the improvement of recovery after muscle injury in hip fracture patients. For this aim we intramuscularly injected placental derived mesenchymal stromal cells during hip fracture arthroplasty. Despite not having reached the primary endpoint, which was the Short Physical Performance Battery, we could observe an increase in
Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry. 16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement:
Extensor mechanism and
Introduction. The arch of the foot has been described as a truss where the plantar fascia (PF) acts as the tensile element. Its role in maintaining the arch has likely been underestimated because it only rarely torn in patients with progressive collapsing foot deformity (PCFD). We hypothesized that elongation of the plantar fascia would be a necessary and sufficient precursor of arch collapse. Method. We used a validated finite element model of the foot reconstructed from CT scan of a female cadaver. Isolated and combined simulated ligament transection models were created for each combination of the ligaments. A collapsed foot model was created by simulated transection of all the arch supporting ligaments and unloading of the posterior tibial tendon. Foot alignment angles, changes in force and displacement within each of the ligaments were compared between the intact, isolated ligament transection, and complete collapse conditions. Result. Isolated release of the PF did not cause deformity, but lead to increased force in the long (142%) and short plantar (156%), deltoid (45%), and spring ligaments (60%). The PF was the structure most able to prevent arch collapse and played a secondary role in preventing hindfoot valgus and forefoot
A medializing calcaneal osteotomy (MCO) is one of the key inframalleolar osteotomies to correct progressive collapsing foot deformity (PCFD). While many studies were able to determine the hind- and midfoot alignment after PCFD correction, the subtalar joint remained obscured by superposition on plain radiography. Therefore, we aimed to perform a 3D measurement assessment of the hind- and subtalar joint alignment pre- compared to post-operatively using weightbearing CT (WBCT) imaging. Fifteen patients with a mean age of 44,3 years (range 17-65yrs) were retrospectively analyzed in a pre-post study design. Inclusion criteria consisted of PCFD deformity correct by MCO and imaged by WBCT. Exclusion criteria were patients who had concomitant midfoot fusions or hindfoot coalitions. Image data were used to generate 3D models and compute the hindfoot - and talocalcaneal angle as well as distance maps. Pre-operative radiographic parameters of the hindfoot and subtalar joint alignment improved significantly relative to the post-operative position (HA, MA. Sa. , and MA. Co. ). The post-operative talus showed significant inversion,
Introduction. This study aimed to evaluate the effectiveness of a novel intraoperative navigation platform for total knee arthroplasty (TKA) in restoring native knee joint kinematics and strains in the medial collateral ligament (MCL) and lateral collateral ligament (LCL) during squatting motions. Method. Six cadaver lower limbs underwent computed tomography scans to design patient-specific guides. Using these scans, bony landmarks and virtual single-line collateral ligaments were identified to provide intraoperative real-time feedback, aided in bone resection, implant alignment, tibiofemoral kinematics, and collateral ligament elongations, using the navigation platform. The specimens were subjected to squatting (35°-100°) motions on a physiological ex vivo knee simulator, maintaining a constant 110N vertical ankle load regulated by active quadriceps and bilateral hamstring actuators. Subsequently, each knee underwent a medially-stabilized TKA using the mechanical alignment technique, followed by a retest under the same conditions used preoperatively. Using a dedicated wand, MCL and LCL insertions—anterior, middle, and posterior bundles—were identified in relation to bone-pin markers. The knee kinematics and collateral ligament strains were analyzed from 3D marker trajectories captured by a six-camera optical system. Result. Both native and TKA conditions demonstrated similar patterns in tibial valgus orientation (Root Mean Square Error (RMSE=1.7°), patellar flexion (RMSE=1.2°),
Pelvic tilt can vary over time due to aging and the possible appearance of sagittal spine disorders. Cup position in total hip arthroplasty (THA) can be influenced due to these changes. We assessed the evolution of pelvic tilt and cup position after THA and the possible appearance of complications for a minimum follow-up of ten years. 343 patients received a THA between 2006 and 2009. All were diagnosed with primary osteoarthritis and their mean age was 63.3 years (range, 56 to 80). 168 were women and 175 men. 250 had no significant lumbar pathology, 76 had significant lumbar pathology and 16 had lumbar fusion. Radiological analysis included sacro-femoral-pubic (SFP), acetabular
Purpose. Ultrasound of the neonatal and infantile hip is a useful tool in diagnosis and treatment of the developmental dysplasia of the hip (DDH), especially given the fact that numerous cases of DDH do not present any findings in the clinical examination. Methods. Between January 2014 and May 2020, 10536 (5273 neonates and infants, 53% girls, 47% boys) consecutive neonatal and infantile hip joints were studied using the Graf Hip Ultrasound method. Results. 607 hips were diagnosed as abnormal. 523 (5%) hip joints were type IIA, 18 (0.17%) were type ΙΙΒ, 19 (0.18%) were type ΙΙC, 33 (0.31%) were type ΙΙΙ and 14 (0.13%) were type IV. 72% of patients were girls, 55% of patients were firstborns, 35,7% presented breech, 8,2% had a positive family history of DDH, 6% were part of a multiple pregnancy, while 27,2% had no predisposing factor for the disease. Type ΙΙΑ hips were treated with follow- up only and had all matured (turned to normal- type I hips) within a trimester. Type ΙΙΒ και ΙΙC hips were treated using an
In the congenital hip dysplasia, patients treated with total hip replacement (THR) often report persistent disability and pain, with unsatisfactory function and quality of life. A major challenge is to restore the center of rotation of the hip and a satisfactory
Keywords. Complete Abductor Detachament, Direct Lateral Approach, Abductor Insuffenciency, Hip Arthroplasty. Backgroung. Approach of Total hip replacement (THR) is a very important part of the surgery, the approach dictates the postoperative complications. Lateral approach is one of the most commonly used approaches. The initial lateral approach relied on bony (trochanteric) osteotomy which was later modified to tendon detachment, there are many versions of the lateral approach but the main goal is to detach the hip abductors mechanism to gain access to the underlying joint. One of the modifications is to completely detach the
Abstract. Background. The influence of diagnosis on outcomes after reverse shoulder arthroplasty (RSA) is not completely understood. The purpose of this study was to compare clinical outcomes of different pathologies. Methods. A total of 78 RSAs were performed for the following diagnoses: (1) rotator cuff tear arthropathy(RCA), (2) massive cuff tear(MCT) with osteoarthritis(OA), (3) MCT without OA, (4) arthritis, (5) acute proximal humerus fracture. Mean follow up 36 months (upto 5 years) Range of motion, Oxford Shoulder Score were obtained preoperatively and postoperatively. Results. Mean OSS was 30. The RCA, MCT-with-OA, MCT-without-OA, and arthritis groups all exhibited significant improvements in all outcome scores and in all planes of motion. After adjustment for age and compared with RCA, those with OA had significantly better