Background: It is common sense that a hemiarthroplasty for the management of a fracture of neck of femur will inevitably lead to the erosion of the natural acetabulum. Therefore it appears appropriate to confine this treatment to patients with a short life expectancy to spare them the experience of this complication and consequent surgery, whereas younger and healthier patients would have to be offered a Total Hip Replacement for that reason. Occasional clinical experience of amazing longevity of hemiar-throplasties cast doubt on this way of thinking. Materials and Methods: A series of 699 hemiarthroplasties done in a Swiss orthopaedic department between 1983 to 2003, were studied with regard to revision surgery because of
Abstract. Introduction. Bipolar hemiarthroplasty(BPHA) for displaced intracapsular neck of femur fractures(DICNOF) is a controversial topic as conflicting evidence exists. The most common reason for revision to total hip arthroplasty(THA) from BPHA is
Nine cases of
The best treatment for a fractured neck of femur in an old person is considered by many to be replacement hemiarthroplasty which allows the patient to walk immediately on a stable, painless hip. The late results can be marred by
Objective: to measure cartilage and bone
Using dried bones which could be tilted and rotated, we assessed the accuracy of published radiographic methods for measuring the migration of prosthetic acetabular components and compared the results with a new method. The new line linking acetabular margins was significantly more accurate for proximal migration than the teardrop, the sacroiliac line or the sacroiliac-symphysis line. For medial migration, a new line tangential to the brim and through the horizontal mid-point of the obturator foramen was more accurate than Kohler's line, the ilio-ischial line or the iliopubic line. In combination, the two new lines can give a more accurate assessment of
We describe a technique to salvage a painful hemiarthroplasty due to erosion of the acetabular cartilage in the absence of loosening of the femoral component. A press-fit metallic acetabular component which matched the femoral component was used as a metal-on-metal articulation. The procedure offered a shorter operation time with less blood loss and no risk of femoral fracture as might have occurred during conventional revision to a total hip replacement. The patient made an unremarkable recovery with a good outcome at follow-up of 15 months.
Hip fractures pose a major global health challenge, leading to high rates of morbidity and mortality, particularly among the elderly. With an ageing population, the incidence of these injuries is rising, exerting significant pressure on healthcare systems worldwide. Despite substantial research aimed at establishing best practice, several key areas remain the subject of ongoing debate. This article examines the latest evidence on the place of arthroplasty in the surgical treatment of hip fractures, with a particular focus on the choice of implant, the use of cemented versus uncemented fixation, and advances in perioperative care. Cite this article:
There is a surge of patients on the waiting-list for primary total hip replacement (THR), due to unprecedented reduction of elective activity caused by COVID-19. A higher incidence of femoral head collapse (FC) and
Aims. Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods. Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results. In total, 1,312 Thompson’s hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4),
A modular hemiarthroplasty has a Metal-on-Metal (MoM) taper-trunnion junction, which may lead to increased wear and Adverse-Reaction-to-Metal-Debris (ARMD). To-date no wear related issues have been described in the elderly and less active that receives a hemiarthroplasty. This study aims to determine in vivo wear (i.e. serum metal ion levels) in hip hemiarthroplasty, and identify factors associated with increased wear. This is a prospective, IRB approved, single-centre, cohort study of patients that received an uncemented, modular hemiarthroplasty of proven design for the treatment of hip fracture between 2013–2015. All, alive, patients at 12-months post-implantation with AMTS≥6 were invited to participate. Of the 125 eligible patients, 50 accepted the invitation and were reviewed, including clinical/radiological assessment, metal-ion ([Chromium (Cr) and Cobalt (Co)]) measurement and Oxford Hip Score (OHS).
Worldwide, it is expected that 6.3 million patients will sustain a hip fracture in 2050. Hemiarthroplasty is commonly practiced for displaced femoral neck fractures. The choice between unipolar (UH) or bipolar (BH) hemiarthroplasty is still controversial. The objective of this study was to assess the effect on hip function of BH compared to UH for a displaced femoral neck fracture in elderly patients. We conducted a systematic review and meta-analysis of randomized controlled trials comparing BH to UH. Data sources were Medline, Embase, Cochrane Library and Web of Science. All data was pooled in Review Manager (RevMan) version 5.3 software. Selection of the studies included, data abstraction, data synthesis, risk of biais and quality of evidence evaluation was done independently by two authors. Our primary outcome was postoperative hip function. Secondary outcomes were health-related quality of life (HRQoL),
Hemiarthroplasty (HA) and total hip arthroplasty (THA) have both been well described as effective methods of management for displaced femoral neck fractures in the elderly. THA has superior functional outcomes and lower long-term revision rates, while HA is associated with lower dislocation rates and faster operative times. While HA remains an appropriate management option in low-demand patients, it is commonly complicated by
Arthroplasty is the most effective management of displaced intracapsular femoral neck fracture. Hemiarthroplasty (HEMI) is associated with
Introduction: Arthroplasty is the most effective management of displaced intracapsular femoral neck fracture. Hemiarthroplasty (HEMI) is associated with
The management of displaced femoral neck fractures in independent, healthy patients remains controversial.
Background. Extendable proximal femoral replacements(PFR) are used in children with bone tumours in proximity to the proximal femoral physis, previously treated by hip disarticulation. Long-axis growth is preserved, allowing limb salvage. Since 1986, survival outcomes after limb salvage and amputation have been known to be equal. Method. Retrospective review of all patients <16years undergoing extendable PFR at Royal National Orthopaedic Hospital (UK) between 04/1996 and 01/2006, recording complications, failures, procedures undertaken and patient outcomes. Results. 8 patients (mean age 8.9±3 years) underwent extendable PFR for Ewing's Sarcoma(5), Osteosarcoma(1), Chondrosarcoma(1) and rhabdomyosarcoma(1). 2 primary PFRs failed (infection of unknown source & local recurrence, both at 26months); 2 required revision for full extension (1 became infected at revision, requiring 2 stage revision). 3 patients had the original prosthesis in situ at last follow-up (mean 7.2;range 3–10.5years). 1 patient had no implant complications, but died (neutropaenic sepsis) 63 days after implant insertion. 2 were treated for recurrence but disease free at last review. 5 were continuously disease free. 5 patients were lengthened a mean 3.7cm; 2 were not lengthened.1 had incomplete data. 5 patients suffered subluxation/dislocation (mean 15.6months), 3 recurrently. Each underwent a mean 1.6 open & 1.4 closed procedures for the displaced joint. 3 patients had 4 open reductions and acetabuloplasties and 2 patients were converted to THR, with 3 major complications: 2 sciatic nerve palsies and 1 (THR) infection. The 5th patient was due for acetabuloplasty but had hip disarticulation for recurrence.
We reviewed the seven- to ten-year results of our previously reported prospective randomised controlled trial comparing total hip replacement and hemiarthroplasty for the treatment of displaced intracapsular fracture of the femoral neck. Of our original study group of 81 patients, 47 were still alive. After a mean follow up of nine years (7 to 10) overall mortality was 32.5% and 51.2% after total hip replacement and hemiarthroplasty, respectively (p = 0.09). At 100 months postoperatively a significantly greater proportion of hemiarthroplasty patients had died (p = 0.026). Three hips dislocated following total hip replacement and none after hemiarthroplasty. In both the total hip replacement and hemiarthroplasty groups a deterioration had occurred in walking distance (p = 0.02 and p <
0.001, respectively). One total hip replacement required revision compared with four hemiarthroplasties which were revised to total hip replacements. All surviving patients with a total hip replacement demonstrated wear of the cemented polyethylene component and all hemiarthroplasties had produced
The use of endoprosthesis implants is frequent for tumours involving the proximal third of the femur and not amenable to primary arthroplasty or internal fixation. In this population, these implants are preferentially cemented given poor bone quality associated with systemic diseases and treatments. Loosening is a common complication of these implants that have been linked to poor bone quality, type of implants and importantly cementing technique. Thus, these techniques vary between different surgeons and based mainly on previous experience. One of the most successful cementing techniques in the arthroplasty literature is the French paradox. This technique involves removing the cancellous bone of the proximal femoral metaphysis and selects the largest stem to tightly fit the created cavity delineated by cortical bone. Cementing the implant results in a very thin cement layer that fills the inconsistent gaps between the metal and the bone. To our knowledge, no previous report exists in the literature assessing loosening in proximal femur replacement using the French paradox cementing technique. In this study, we sought to examine (1) rates of loosening in proximal femur replacement, and (2) the oncological outcomes including tumour recurrence and implant related complications. A retrospective study of 42 patients underwent proximal femur replacement between 1990 and 2018 at our institution. Of these, 30 patients met our inclusion criteria. Two independent reviewers have evaluated the preoperative and the most recent postoperative radiographs using the International Society of Limb Salvage (ISOLS) radiographic scoring system and Gruen classification for femoral stem loosening. Additionally, the acetabulum was evaluated for erosion according to the criteria of Baker et al. The mean age of this cohort was 60.5 (19–80), with 60% being males. The primary origin was metastatic in 17 (56.7%) patients, bone sarcoma in 10 (33.3%) patients and soft tissue sarcoma in 3 (10%) patients. Pathological fractures were present in 11 (36.7%) patients. Seven (23.3%) patients had prior intramedullary nailing. Preoperative radiotherapy was used in 8 (26.7%) and postoperative radiotherapy in 17 (56.7%) patients. The mean clinical follow-up was 25.2±26.3 months and the mean radiographical follow-up was 24.8±26 months. The mean ISOLS score for both reviewers was found to be 89±6.5% and 86.5±6.1%, respectively. Additionally, the first reviewer found two patients to be possibly loos (6.7%) compared to one (3.3%) patient for the second reviewer. No components scored as probably or definitely loose and non-required revision for either loosening or metal failure. Furthermore, both reviewers showed no
Introduction. Total hip arthroplasty (THA) is the most common surgery performed for complications of bipolar arthroplasty. The present study evaluated the functional results and complications associated with this surgery. Patients and Methods. Forty eight hips (48 patients) who had conversion of bipolar arthroplasty to THA between 1998 June and 2013 June, and who were followed-up for more than one year were evaluated. Twenty one hips had conversion surgery to THA using a Fitmore cup with metal-on-metal articulation (28 mm head). Six hips had surgery using the SecurFit cup and three hips, using the Lima LTO cup with ceramic-on-ceramic articulation (28 mm or 32 mm head). Eighteen hips had surgery using a large head metal-on-metal bearing: –MMC (seven hips), ACCIS (six hips) and Magnum (five hips). The average time of follow-up duration was 3.9 years (range, 1.0–11.3). There were 22 men and 26 women between the ages of 28 and 80 years (average, 68.9 years) at the time of conversion surgery. Conversion arthroplasty was performed for