Introduction. Primary stability is achieved by the press fit technique, where an oversized component is inserted into an undersized reamed cavity. The major geometric design of an
A retrospective single-center review has been performed to gather clinical data on the use of polycarbonate-urethane (PCU) as an articulating bearing material inside a cobalt-chrome (Co-Cr) press-fit
INTRODUCTION. Deformation of modular
Revision total hip replacements are likely to have higher complication rates than primary procedures due to the poor quality of the original bone. This may be constrained to achieve adequate fixation strength to prevent future “aseptic loosening” [1]. A thin, slightly flexible, acetabular component with a three dimensional, titanium foam in-growth surface has been developed to compensate for inferior bone quality and decreased contact area between the host bone and implant by better distributing loads across the remaining acetabulum in a revision situation. This is assumed to result in more uniform bone apposition to the implant by minimizing stress concentrations at the implant/bone contact points that may be associated with a thicker, stiffer acetabular component, resulting in improved implant performance.[2] To assemble the liner to the shell, the use of PMMA bone cement is recommended at the interface between the polyethylene insert and the
Introduction. A majority of the
1) INTRODUCTION. Acetabular fixation in cementless total hip arthroplasty (THA) relies on new technology for stability and survivorship of the implant. A highly porous 3D titanium coating was developed with a biologically inspired pore structure to improve initial friction fixation with mechanical stability and long term biological fixation. Ongoing research is investigating potential radiographic phenomenons these coatings produce, resulting in the presence of lucent lines. The purpose of this study was to evaluate clinical and radiographic outcomes of a 3D highly porous-coated titanium
Background. Instability and dislocation are some of the most important postoperative complications and potential causes of failure that dual mobility total hip arthroplasty (THA) systems continue to address. Studies have shown that increasing the relative head size provides patients implanted with smaller and larger cups increased stability, greater ROM and a lesser incidence of impingement, without compromising clinical results. The purpose of the current study was to review clinical outcomes in three groups of primary THA patients receiving a dual mobility
Introduction:. The management strategy regarding optimally addressing polyethylene wear with a well-fixed
INTRODUCTION. Deformation of modular
BACKGROUND. During revision hip arthroplasty, removal of a well-fixed, ingrown metal acetabular component may not be possible. Therefore, a new polyethylene liner can be cemented into the existing shell via the cement locking mechanism. We report the indications, technique, and results of cementing an acetabular liner into a well-fixed cementless
Total hip arthroplasty (THA) is an effective treatment for symptomatic hip osteoarthritis (OA). Computer-navigation technologies in total knee arthroplasty show evidence-supported survivorship advantages and are used widely. The aim of this study was to determine the revision outcome of hip commercially available navigation technologies. Data from the Australian Orthopaedic Association National Joint Replacement Registry from January 2016 to December 2020 included all primary THA procedures performed for osteoarthritis (OA). Procedures using the Intellijoint HIP® navigation were identified and compared to procedures inserted using ‘other’ computer navigation systems and to all non-navigated procedures. The cumulative percent revision (CPR) was compared between the three groups using Kaplan-Meier estimates of survivorship and hazard ratios (HR) from Cox proportional hazards models, adjusted for age and gender. A prosthesis specific analysis was also performed. There were 1911 procedures that used the Intellijoint® system, 4081 used ‘other’ computer navigation, and 160,661 were non-navigated. The all-cause 2-year CPR rate for the Intellijoint HIP® system was 1.8% (95% CI 1.2, 2.6), compared to 2.2% (95% CI 1.8, 2.8) for other navigated and 2.2% (95% CI 2.1, 2.3) for non-navigated cases. A prosthesis specific analysis identified the Paragon/
Introduction. A variety of porous coatings and substrates have been used to obtain fixation at the bone-implant interface. Clinical studies of porous tantalum, have shown radiographically well-fixed implants with limited cases of loosening. However, there has been limited retrieval analysis of porous tantalum hip implants. The purpose of this study was to investigate factors affecting bone ingrowth into porous tantalum hip implants. Methods. 126 porous tantalum
In revision total hip arthroplasty (THA), acetabular reconstruction while dealing with severe bone loss is a challenge. The porous tantalum revision
Polyimide (MP-1, MMATech, Haifa, Israel), is a high performance aerospace thermoplastic used for its lubricity, stability, inertness and radiation resistance. A wear resistant thin robust bearing is needed for total hip arthroplasty (THR). After independent laboratory testing, in 2006, the author used the material as a bearing in two Reflection (Smith and Nephew, USA) hip surgeries. The first, a revision for polyethylene wear, survives with no evidence of wear, noise, new osteolysis or complications related to the MP-1 bearing after 16 yrs. The second donated his asymptomatic MP-1 hip at 6.5yrs for post-mortem examination. There were no osteoclasts, cellular reaction bland in contrast to that of polyethylene. In 2013 a clinical study with ethical committee approval was started using a Biolox Delta (Ceramtec, Germany) head against a polyimide liner in 97 patients. MMATech sold all liners, irradiated: steam 52:45. Sixteen were re-machined in New Zealand.
Iliopsoas tendonitis after total hip arthroplasty (THA) can be a considerable cause of pain and patient dissatisfaction. The optimal cup position to avoid iliopsoas tendonitis has not been clearly established. Implant designs have also been developed with an anterior recess to avoid iliopsoas impingement. The purpose of this cadaveric study was to determine the effect of cup position and implant design on iliopsoas impingement. Bilateral THA was performed on three fresh frozen cadavers using oversized (jumbo) offset head center revision acetabular cups with an anterior recess (60, 62 and 66 mm diameter) and tapered wedge primary stems through a posterior approach. A 2mm diameter flexible stainless steel cable was inserted into the psoas tendon sheath between the muscle and the surrounding membrane to identify the location of the psoas muscle radiographically. CT scans of each cadaver were imported in an imaging software. The
In primary total hip replacements there are numerous options available for providing hip stability in difficult situations (i.e. Down's syndrome, Parkinson's disease). We have considered constrained liners in some of these cases. However, in the revision situation in general and in revision for recurrent dislocation situation specifically it is important to have all options available including tripolar constrained liners in order to optimise the potential for hip stability as well as function of the arthroplasty. Even with the newer options available dislocation rates of higher than 10–15% have been reported following revision surgery at institutions where high volumes of revision surgery are performed. Because of the deficient abductors, other soft tissue laxity and the requirement for large diameter cups revision cases will always have more potential for dislocation. In these situations in the lower demand patient, constraint has provided excellent success in terms of preventing dislocation and maintaining implant construct fixation to bone at intermediate- term follow-up. Hence in these situations tripolar constrained liners remains the option we utilise. We are also confident in using this device in cases with instability or laxity where there is a secure well- positioned
In the revision situation in general and for recurrent dislocation specifically, it is important to have all options available including tripolar constrained liners in order to optimise the potential for hip stability as well as function. Even with the newer options available, dislocation rates of higher than 5% have been reported in the first two years following revision surgery at institutions where high volumes of revision surgery are performed (Wera et al). Because of the deficient abductors, other soft tissue laxity and the requirement for large diameter cups, revision cases will always have more potential for dislocation. In these situations, in the lower demand patient, tripolar constrained liners provided excellent success in terms of preventing dislocation and maintaining implant construct fixation to bone at intermediate term follow-up. Hence in these situations, tripolar with constraint remains the option we utilise in many cases. We are also confident in using this device in cases with instability or laxity where there is a secure well positioned
In primary total hip replacements there are numerous options available for providing hip stability in difficult situations (i.e. Down's syndrome, Parkinson's disease). However, in the revision situation in general and in revision for recurrent dislocation specifically, it is important to have all options available including dual mobility constrained liners in order to optimise the potential for hip stability as well as function of the arthroplasty. Even with the newer options, available dislocation rates of higher than 5% have been reported in the first two years following revision surgery at institutions where high volumes of revision surgery are performed. Because of the deficient abductors, other soft tissue laxity and the requirement for large diameter cups, revision cases will always have more potential for dislocation. In these situations in the lower demand patient and where, a complex acetabular reconstruction that requires time for ingrowth before optimal implant bone stability to occur isn't present, dual mobility with constraint has provided excellent success in terms of preventing dislocation and maintaining implant construct fixation to bone at intermediate term follow-up. Hence in these situations dual mobility with constraint remains the option we utilise. We are also confident in using this device in cases with instability or laxity where there is a secure well-positioned
Introduction. Acetabular revision surgery remains a technically demanding procedure with higher failure rates than primary total hip arthroplasty (THA). An acetabular component with three dimensional porous titanium and anatomic screw holes (Figure 1) was designed to allow the cup to be positioned anatomically and provide reliable fixation. Methods. A prospective multicenter study of 193 cases (190 patients) was conducted to assess the midterm clinical outcomes of the revision titanium
In primary total hip replacements there are numerous options available for providing hip stability in difficult situations i.e. Down's syndrome, Parkinson's disease. However, in the revision situation, in general, and in revision for recurrent dislocation situations specifically, it is important to have all options available including dual mobility constrained liners in order to optimise the potential for hip stability as well as function of the arthroplasty. Even with the newer options available dislocation rates of higher than 5% have been reported in the first two years following revision surgery at institutions where high volumes of revision surgery are performed [Della Valle, Sporer, Paprosky unpublished data]. Because of the deficient abductors, other soft tissue laxity and the requirement for large diameter cups, revision cases will always have more potential for dislocation. In these situations in the lower demand patient and where, a complex acetabular reconstruction that requires time for ingrowth before optimal implant bone stability to occur isn't present, dual mobility with constraint has provided excellent success in terms of preventing dislocation and maintaining implant construct fixation to bone at intermediate term follow-up. Hence in these situations dual mobility with constraint remains the option we utilise. We are also confident in using this device in cases with instability or laxity where there is a secure well-positioned