Advertisement for orthosearch.org.uk
Results 1 - 20 of 191
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 63 - 63
14 Nov 2024
Ritter D Bachmaier S Wijdicks C Raiss P
Full Access

Introduction. The increased prevalence of osteoporosis in the patient population undergoing reverse shoulder arthroplasty (RSA) results in significantly increased complication rates. Mainly demographic and clinical predictors are currently taken into the preoperative assessment for risk stratification without quantification of preoperative computed tomography (CT) data (e.g. bone density). It was hypothesized that preoperative CT bone density measures would provide objective quantification with subsequent classification of the patients’ humeral bone quality. Methods. Thirteen bone density parameters from 345 preoperative CT scans of a clinical RSA cohort represented the data set in this study. The data set was divided into testing (30%) and training data (70%), latter included an 8-fold cross validation. Variable selection was performed by choosing the variables with the highest descriptive value for each correlation clustered variables. Machine learning models were used to improve the clustering (Hierarchical Ward) and classification (Support Vector Machine (SVM)) of bone densities at risk for complications and were compared to a conventional statistical model (Logistic Regression (LR)). Results. Clustering partitioned this cohort (training data set) into a high bone density subgroup consisting of 96 patients and a low bone density subgroup consisting of 146 patients. The optimal number of clusters (n = 2) was determined based on optimization metrics. Discrimination of the cross validated classification model showed comparable performance for the training (accuracy=91.2%; AUC=0.967) and testing data (accuracy=90.5 %; AUC=0.958) while outperforming the conventional statistical model (Logistic Regression (LR)). Local interpretable model-agnostic explanations (LIME) were created for each patient to explain how the predicted output was achieved. Conclusion. The trained and tested model provides preoperative information for surgeons treating patients with potentially poor bone quality. The use of machine learning and patient-specific calibration showed that multiple 3D bone density scores improved accuracy for objective preoperative bone quality assessment


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 66 - 66
1 May 2017
Jolles-Haeberli B Meyer V Cavinato A Chakravarty P Omoumi P Favre J
Full Access

Background. Some models of knee osteoarthritis (OA) suggest that the properties of knee tissues are adapted in healthy joints, and that OA development is due to a breakdown in the equilibrium among tissue properties. Cartilage thickness and bone density are particularly important properties in this regard because both are related to the mechanical environment. This study tested the hypothesis that locations of thickest cartilage are associated with locations where bone density is the highest in non-OA tibias. Method. CT-arthrography was performed on six non-OA subjects (2 males; 58± 15 years old). Images were segmented to build 3D models of the bone and cartilage structures. Maps of cartilage thickness were calculated for the medial and lateral subchondral bone areas by measuring the distance between bone and cartilage structures. Bone density maps were calculated based on the intensity of the CT-arthrography signal in the first 3mm of bone. The location of thickest cartilage and most dense bone were measured in the medial and lateral compartments. These locations were then normalised, and paired t-tests and linear regressions were performed to compare the thickness and density locations. Results. In the medial compartment, the location of highest bone density was significantly more medial than the location of thickest cartilage (p=0.03). Additionally, the location of both features were highly correlated along the anterior-posterior direction (R⁁2=0.92). In the lateral compartment, the location of highest bone density was correlated with the location of thickest cartilage along the medial-lateral direction (R⁁2 =0.64). Conclusion. This study showed that the location of highest bone density is correlated with the location of thickest cartilage in non-OA tibias, thus supporting the idea that knee tissues are adapted in healthy knees


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 53 - 53
1 Nov 2018
Karia M Ali A Harris S Abel R Cobb J
Full Access

Tibial bone density may affect implant stability and functional outcomes following total knee replacement (TKR). Our aim was to characterise the bone density profile at the implant-tibia interface following TKR in mechanical versus kinematic alignment. Pre-operative computed tomography scans for 10 patients were obtained. Using surgical planning software, tibial cuts were made for TKR either neutral (mechanical) or 3 degrees varus (kinematic) alignment. Signal intensity, in Hounsfield Units (HU), was measured at 25,600 points throughout an axial slice at the implant-tibia interface and density profiles compared along defined radial axes from the centre of the tibia towards the cortices. From the tibial centre towards the lateral cortex, trabecular bone density for kinematic and mechanical TKR are similar in the inner 50% but differ significantly beyond this (p= 0.012). There were two distinct density peaks, with peak trabecular bone density being higher in kinematic TKR (p<0.001) and peak cortical bone density being higher in mechanical TKR (p<0.01). The difference in peak cortical to peak trabecular signal was 43 HU and 185 HU respectively (p<0.001). On the medial side there was no significant difference in density profile and a linear increase from centre to cortex. In the lateral proximal tibia, peak cortical and peak trabecular bone densities differ between kinematic TKR and mechanical TKR. Laterally, mechanical TKR may be more dependent upon cortical bone for support compared to kinematic TKR, where trabecular bone density is higher. This may have implications for surgical planning and implant design


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 31 - 31
1 May 2012
Findlay C Jameson S Marshall S Walker B Walker C Meek R Nicol A
Full Access

Background. Following an anterior cruciate ligament (ACL) injury, the affected knee is known to experience bone loss and is at significant risk of becoming osteoporotic. Surgical reconstruction is performed to attempt to restore the function of the knee and theoretically restore this bone density loss. Cross-sectional analysis of the proximal tibia using peripheral quantitative computed tomography (pQCT) enables localised analysis of bone mineral density (BMD) changes. The aim of this study was to establish the pattern of bone density changes in the tibia pre- and post- ACL reconstruction using pQCT image analysis. Methods. Eight patients who underwent ACL reconstruction were included. A cross sectional analysis of the proximal tibia was performed using a pQCT scanner pre-operatively and one to two years post-operatively on both the injured and contralateral (control) knee. The proximal two and three percent slices [S2 and S3] along the tibia were acquired. These were exported to Matlab(tm) and automated segmentation was performed to remove the tibia from its surrounding structures. Cross correlation was applied to co-register pairs of images and patterns of change in BMD were mapped using a t-test (p<0.05). Connected components of pixels with significant change in BMD were created and used to assess the impact of ACL injury & reconstruction on the proximal tibial BMD. Results. Prior to surgical ACL reconstruction, the BMD in the injured leg was significantly reduced relative to the control leg [S2: p=0.002, S3: p=0.002]. Post surgery, the proximal tibial BMD did not change in either leg [Control S2: p=0.102, S3: p=0.181; Injured S2: p=0.093, S3: p=0.439]. The post surgical images demonstrated patterns of increasing BMD surrounding the tunnel in the form of compact bone. Discussion. A significant reduction in proximal tibial BMD was observed in the ACL injured legs relative to control legs. The pattern of pre-operative bone loss was generally observed to be global across the entire slice. No change in BMD was observed following ACL reconstruction, in either injured or control leg. These results indicate that proximal tibial BMD is reduced and does not change after ACL reconstruction


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 49 - 49
11 Apr 2023
Speirs A Melkus G Rakhra K Beaule P
Full Access

Femoroacetabular impingement (FAI) results from a morphological deformity of the hip and is associated with osteoarthritis (OA). Increased bone mineral density (BMD) is observed in the antero-superior acetabulum rim where impingement occurs. It is hypothesized that the repeated abnormal contact leads to damage of the cartilage layer, but could also cause a bone remodelling response according to Wolff's Law. Thus the goal of this study was to assess the relationship between bone metabolic activity measured by PET and BMD measured in CT scans. Five participants with asymptomatic cam deformity, three patients with uni-lateral symptomatic cam FAI and three healthy controls were scanned in a 3T PET-MRI scanner following injection with [18F]NaF. Bone remodelling activity was quantified with Standard Uptake Values (SUVs). SUVmax was analyzed in the antero-superior acetabular rim, femoral head and head-neck junction. In these same regions, BMD was calculated from CT scans using the calibration phantom included in the scan. The relationship between SUVmax and BMD from corresponding regions was assessed using the coefficient of determination (R. 2. ) from linear regression. High bone activity was seen in the cam deformity and acetabular rim. SUVmax was negatively correlated with BMD in the antero-superior region of the acetabulum (R. 2. =0.30, p=0.08). SUVmax was positively correlated with BMD in the antero-superior head-neck junction of the femur (R. 2. =0.359, p=0.067). Correlations were weak in other regions. Elevated bone turnover was seen in patients with a cam deformity but the relationship to BMD was moderate. This study demonstrates a pathomechanism of hip degeneration associated with FAI deformities, consistent with Wolff's law and the proposed mechanical cause of hip degeneration in FAI. [18F]-NaF PET SUV may be a biomarker of degeneration, especially in early stages of degeneration, when joint preservation surgery is likely to be the most successful


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 74 - 74
1 Apr 2018
Chevalier Y Chamseddine M Santos I Müller P Pietschmann M
Full Access

Introduction. Glenoid loosening, still a main complication for shoulder arthroplasty, was suggested to be related implant design, surgical aspects, and also bone quality. However, typical studies of fixation do not account for heterogeneity in bone morphology and density which were suggested to affect fixation failure. In this study, a combination of cyclic rocking horse tests on cadaver specimens and microCT-based finite element (microFE) analysis of specimens of a wide range of bone density were used to evaluate the effects of periprosthetic bone quality on the risks of loosening of anatomical keeled or pegged glenoid implants. Methods. Six pairs of cadaveric scapulae, scanned with a quantitative computer tomography (QCT) scanner to calculate bone mineral density (BMD), were implanted with either cemented anatomical pegged or keeled glenoid components and tested under constant glenohumeral load while a humeral head component was moved cyclically in the inferior and superior directions. Edge displacements were measured after 1000, 4000 and 23000 test cycles, and tested for statistical differences with regards to changes or implant design. Relationships were established between edge displacements and QCT-based BMD below the implant. Four other specimens were scanned with high-resolution peripheral QCT (82µm) and implanted with the same 2 implants to generate virtual models. These were loaded with constant glenohumeral force, varying glenohumeral conformity and superior or inferior load shifts while internal stresses at the cement-bone and implant-cement interfaces were calculated and related to apparent bone density in the periprosthetic zone. Results. Mean displacements at the inferior and superior edges showed no statistical difference between keeled and pegged designs (p>0.05). Compression and distraction were however statistically different from the initial reference measurement at even 1000 and 4000 cycles for both implant designs (p<0.05). For both implant designs, superior and inferior distractions were generally highest at each measurement time in specimens where BMD below the lifting edge was lower, showing a trend of increased distraction with decreased BMD. Moreover, the microFE models predicted higher bone and cement stresses for specimens of lower apparent bone density. Finally, highest peak stresses were located at the cement-bone interface, which seemed the weaker part of the fixation. Discussion. With this combined experimental and numerical study, it was shown that implant distraction and stresses in the cement layer are greater in glenoids of lower bone density for both implant designs. This indicates that fixation failure will most likely occur in bone of lower density, and that fixation design itself may play a secondary role. These results have important impact for understanding the mechanisms of glenoid component failure, a common complication of total shoulder arthroplasty


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 22 - 22
11 Apr 2023
Sun Y
Full Access

To analyze the effect of tooth extraction site preservation on bone mineral density 6 months after surgery. From 2020 to 2021, two adjacent teeth (37, 38) of the same patient were extracted at the same time, and then 37 were selected for site preservation, implanted with Bio-oss bone powder, covered with double Bio-gide membrane, reduce tension and sutured. After 6 months of self-healing, 38 was taken CBCT, and the gray value measurement tool in the software was used to measure the bone mineral density of 37 bone graft areas and 38 extraction sockets. Bone density was high in the center of the bone graft area after the extraction site, and the density decreased in the adjacent alveolar socket, but the gray value was still higher than 38 for natural healing. Extraction site surgery can improve bone mass and quality at the extraction site. It is good for implanting


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 71 - 71
1 May 2017
Formoy E Ekpo E Thomas T Kocialkowski C Pillai A
Full Access

Background. Reduced bone mineral density is recognised as a risk factor for hip fractures and fragility fractures in general. Vitamin D is important in maintaining healthy bone mineral levels and can therefore affect risk of hip fracture. We investigated the correlation between vitamin D levels and bone mineral density, as well as fracture type, in neck of femur fractures and also assessed the relationship of vitamin D and social deprivation. Method. We included all patients admitted to our department, with a neck of femur fracture over one year (October 2013 to October 2014). We analysed vitamin D levels for all patients during admission and compared these to bone mineral density scores, based on DEXA scan results; hip fracture type & comminution, based on admission radiographs; and levels of social deprivation, based on the patient's address. Results. In total 360 patients were admitted over the study period, with a neck of femur fracture, of which 298 had vitamin D assessed and 76 had DEXA scans. Of these cohorts, 71% were found to be vitamin D deficient and 7% had osteoporosis. No significant correlation was found between vitamin D scores and bone density, or with level of vitamin D deficiency and fracture type or comminution. A significant correlation was however identified, between low vitamin D levels and decreasing levels of social deprivation (R=0.11, p=0.04). Conclusion. No relationship was identified between vitamin D levels and hip fracture type, suggesting that vitamin D cannot be used to predict patients at risk of more comminuted fractures. Although no relationship was also identified for bone mineral density and vitamin D, this may be because the sample size of DEXA scans was relatively small. Interestingly the relationship between vitamin D and social deprivation was the reverse of what was expected and suggests that affluent individuals may be at greater risk of low vitamin D


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD. Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system. BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension. ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered. For any figures or tables, please contact the authors directly


Bone & Joint Research
Vol. 3, Issue 1 | Pages 14 - 19
1 Jan 2014
James SJ Mirza SB Culliford DJ Taylor PA Carr AJ Arden NK

Aims. Osteoporosis and abnormal bone metabolism may prove to be significant factors influencing the outcome of arthroplasty surgery, predisposing to complications of aseptic loosening and peri-prosthetic fracture. We aimed to investigate baseline bone mineral density (BMD) and bone turnover in patients about to undergo arthroplasty of the hip and knee. Methods. We prospectively measured bone mineral density of the hip and lumbar spine using dual-energy X-ray absorptiometry (DEXA) scans in a cohort of 194 patients awaiting hip or knee arthroplasty. We also assessed bone turnover using urinary deoxypyridinoline (DPD), a type I collagen crosslink, normalised to creatinine. Results. The prevalence of DEXA proven hip osteoporosis (T-score ≤ -2.5) among hip and knee arthroplasty patients was found to be low at 2.8% (4 of 143). Spinal osteoporosis prevalence was higher at 6.9% (12 of 175). Sixty patients (42% (60 of 143)) had osteopenia or osteoporosis of either the hip or spine. The mean T-score for the hip was -0.34 (. sd. 1.23), which is within normal limits, and the mean hip Z-score was positive at 0.87 (. sd. 1.17), signifying higher-than-average BMD for age. The median urinary DPD/creatinine was raised in both female patients at 8.1 (interquartile range (IQR) 6.6 to 9.9) and male patients at 6.2 (IQR 4.8 to 7.5). Conclusions. Our results indicate hip and knee arthroplasty patients have higher BMD of the hip and spine compared with an age-matched general population, and a lower prevalence of osteoporosis. However, untreated osteoporotic patients are undergoing arthroplasty, which may negatively impact their outcome. Raised DPD levels suggest abnormal bone turnover, requiring further investigation. Cite this article: Bone Joint Res 2014;3:14–19


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 99 - 99
1 Nov 2018
Mizrak S Turan V Inan S Uysal A Yilmaz C Gürdal M Ercan G
Full Access

To prevent bone loss, OPG/RANK/RANKL signalling pathway is a key in keeping the balance between the action of osteoblasts and osteoclasts. Aim of this study is to assess the influence of long-term nicotine exposure on bone mineral density (BMD) scores, RANKL and OPG levels of plasma and RANKL and OPG immunoreactivities of tissue in rats. In this study, totally 36 Swiss Albino rats (70±10 g) were used in three groups. Whereas normal drinking water was given for the control group (n:12), 0.4 mg/kg/day and 6.0 mg/kg/day nicotine was added to drinking water for low-dose nicotine (LDN) group (n:12) and high-dose nicotine (HDN) group (n:12), respectively for 12 months. At the end of 12. th. month, BMD scores were measured via X-ray absorptiometry and then bone turnover was assessed via measuring both RANKL, OPG levels in plasma and RANKL, OPG immunoreactivities in tail vertebrae of all rats. Lumbar spine and femoral regions BMD scores of the control group and the nicotine groups were not significantly difference. In HDN group, OPG levels of plasma were found significantly higher when compared with the control and LDN groups (p=0.001) unlike RANKL levels of plasma. RANKL and OPG immunoreactivities of tissue were found significantly lower in both LDN and HDN groups (p<0.001, p=0.004, respectively) in comparison to control group. No correlation was found between plasma levels and tissue immunoreactivities of RANKL and OPG. As a result, this study indicates that nicotine is not primarily responsible for the decline of BMD frequently seen in smokers


Bone & Joint Research
Vol. 6, Issue 10 | Pages 572 - 576
1 Oct 2017
Wang W Huang S Hou W Liu Y Fan Q He A Wen Y Hao J Guo X Zhang F

Objectives. Several genome-wide association studies (GWAS) of bone mineral density (BMD) have successfully identified multiple susceptibility genes, yet isolated susceptibility genes are often difficult to interpret biologically. The aim of this study was to unravel the genetic background of BMD at pathway level, by integrating BMD GWAS data with genome-wide expression quantitative trait loci (eQTLs) and methylation quantitative trait loci (meQTLs) data. Method. We employed the GWAS datasets of BMD from the Genetic Factors for Osteoporosis Consortium (GEFOS), analysing patients’ BMD. The areas studied included 32 735 femoral necks, 28 498 lumbar spines, and 8143 forearms. Genome-wide eQTLs (containing 923 021 eQTLs) and meQTLs (containing 683 152 unique methylation sites with local meQTLs) data sets were collected from recently published studies. Gene scores were first calculated by summary data-based Mendelian randomisation (SMR) software and meQTL-aligned GWAS results. Gene set enrichment analysis (GSEA) was then applied to identify BMD-associated gene sets with a predefined significance level of 0.05. Results. We identified multiple gene sets associated with BMD in one or more regions, including relevant known biological gene sets such as the Reactome Circadian Clock (GSEA p-value = 1.0 × 10. -4. for LS and 2.7 × 10. -2. for femoral necks BMD in eQTLs-based GSEA) and insulin-like growth factor receptor binding (GSEA p-value = 5.0 × 10. -4. for femoral necks and 2.6 × 10. -2. for lumbar spines BMD in meQTLs-based GSEA). Conclusion. Our results provided novel clues for subsequent functional analysis of bone metabolism, and illustrated the benefit of integrating eQTLs and meQTLs data into pathway association analysis for genetic studies of complex human diseases. Cite this article: W. Wang, S. Huang, W. Hou, Y. Liu, Q. Fan, A. He, Y. Wen, J. Hao, X. Guo, F. Zhang. Integrative analysis of GWAS, eQTLs and meQTLs data suggests that multiple gene sets are associated with bone mineral density. Bone Joint Res 2017;6:572–576


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_2 | Pages 111 - 111
1 Jan 2017
Menichetti A Gargiulo P Gislason M Edmunds K Hermannsson T Jonsson H Esposito L Bifulco P Cesarelli M Fraldi M Cristofolini L
Full Access

Total Hip Replacement (THR) is one of the most successful operations in all of medicine, however surgeons just rely on their experience and expertise when choosing between cemented or cementless stem, without having any quantitative guidelines. The aim of this project is to provide clinicians with some tools to support in their decision making. A novel method based on bone mineral density (BMD) measurements and assessments was developed 1) to estimate the periprosthetic fracture risk (FR) while press-fitting cementless stem; 2) to evaluate post-operative bone remodeling in terms of BMD changes after primary THR. Data for 5 out of over 70 patients (already involved in a previous study. 1. ) that underwent primary THA in Iceland were selected for developing novel methods to assess intra-operative FR and bone mineral density (BMD) changes after the operation. For each patient three CT images were acquired (Philips Brilliance 64 Spiral-CT, 120 kVp, slice thickness: 1 mm, slice increment: 0.5 mm): pre-op, 24 hours and 1 year post-operative. Pre-op CT scan was used to create 3D finite element model (Materialise Mimics) of the proximal femur. The material properties were assigned based on Hounsfield Units. Different strategies were analyzed for simulating the press-fitting operation, developing what has already been done in prior study. 1. In the finite element simulation (Ansys Workbench), a pressure (related to the implant hammering force of 9.25 kN. 2. ) was applied around the femur's hollow for the stem and the distribution of maximum principal elastic strain over the bone was calculated. Assuming a critical failure value. 3. of 7300 με, the percentage of fractured elements was calculated (i.e. FR). Post 24 hours and Post 1 year CT images were co-registrated and compared (Materialise Mimics) in order to assess BMD changes. Successively, volumes of bone lost and bone gained were calculated and represented in a 3D model. Age and gender should not be taken as unique indicators to choose between implants typologies, since also three dimensional BMD distribution along with volume of cortical bone influence the risk of periprosthetic fractures. Highest FR values were experienced in the calcar-femorale zone and in similar location on the posterior side. BMD loss volume fractions after 1 year were usually higher than BMD gain ones. Consistently with prior studies. 4. , BMD loss was mainly concentrated around the proximal end (lesser trochanter area, outer bone). If present, BMD gain occurred at the distal end (below stem's tip) or proximally (lesser trochanter area, interface contact with the stem). The use of clinical data for BMD assessments serves as an important tool to develop a quantitative method which will support surgeons in their decisions, guiding them to the optimal implant for the patient. Knowing the risk of fracture if choosing a cementless stem and being aware of how the bone will remodel around the stem in one year's time can eventually lead to reduction in revisions and increased quality of life for the patient. Further work will target analysis of a larger cohort of patients and validate FE models


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 57 - 57
1 Mar 2013
Boyne S Chan B Morgan H Webb S Knapp K Meakin J
Full Access

The shape of the vertebral bodies from L1 to L4 was assessed from lateral dual-energy x-ray absorptiometry (DXA) images using an active shape model. The output from the model was compared to measurements of areal bone mineral density in L1 to L4 (aBMD) using a stepwise linear regression model. A significant relationship was found between aBMD and vertebral shape that suggests that the method may be useful for correcting artefacts such as osteophytes


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 34 - 34
1 Jun 2012
Spencer S Blyth M Lovell F Holt G
Full Access

Fragility fractures are an increasing cause of morbidity and mortality in the elderly population. Their association with reduced bone mineral density (BMD) is well documented. It is a reasonable assumption that hip fracture severity is linked to the magnitude of bone loss, (the lower the BMD, the more severe the fracture), however it is not known whether this correlation exists. Our aim therefore was to investigate the relationship between BMD and hip fracture severity. We reviewed 142 patients, 96 females and 46 males, mean age 74 years (49-92), who had sustained a hip fracture following a simple ground level fall. All had subsequently undergone DEXA bone scanning of the contralateral hip and lumbar spine. Fractures were classified as intra-capsular, extra-capsular or subtrochanteric, then sub-classified using the Garden, Jensen and Seinsheimer classifications respectively. They were grouped into simple (stable) or comminuted (unstable) fracture patterns. Risk factors for osteoporosis were recorded. A low hip BMD (<2.5) was associated with an increased risk of extra-capsular fracture (p=0.025). However, no association with fracture type (extra vs. intra-capsular, p>0.05) was identified with the following variables; age, gender, BMI <25, smoking, and excess alcohol intake. We did not find any statistically significant associations between fracture severity and the nine principle variables tested for: age; gender; smoking; BMI < 25; alcohol excess and low hip or lumbar BMD T or Z score <-2.5. Although the association between BMD and risk of fragility fractures is well documented, the results of this study would suggest that severity of hip fractures does not follow this correlation. Therefore, no assumption can be made about BMD of the proximal femur based on the severity of fracture observed on plain radiographs alone


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 7 | Pages 984 - 988
1 Jul 2007
Omi H Kusumi T Kijima H Toh S

We investigated the effect of locally administered bisphosphonate on distraction osteogenesis in a rabbit model and evaluated its systemic effect. An osteotomy on the right tibia followed by distraction for four weeks was performed on 47 immature rabbits. They were divided into seven equal groups, with each group receiving a different treatment regime. Saline and three types of dosage of alendronate (low, 0.75 μg/kg; mid, 7.5 μg/kg and high 75 μg/kg) were given by systemic injection in four groups, and saline and two dosages (low and mild) were delivered by local injection to the distraction gap in the remaining three groups. The injections were performed five times weekly during the period of distraction. After nine weeks the animals were killed and image analysis and mechanical testing were performed on the distracted right tibiae and the left tibiae which served as a control group. The local low-dose alendronate group showed a mean increase in bone mineral density of 124.3 mg/cm. 3. over the local saline group (analysis of variance, p < 0.05) without any adverse effect on the left control tibiae. The findings indicate that the administration of local low-dose alendronate could be an effective pharmacological means of improving bone formation in distraction osteogenesis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XI | Pages 33 - 33
1 Apr 2012
Fraser-Moodie J Mccaul J Brooksbank A
Full Access

Locking plate fixation in proximal humeral fractures has demonstrated good results tempered by a significant rate of loss of fixation. Reported rates of failure are typically around 10% of cases but can be 20% or higher. In addition large series are often made up of a diverse patient population, so we have chosen to focus solely on patients confirmed to have significantly reduced BMD who can be considered a subset at high risk of fixation failure. Twenty-three patients (5 male, 18 female) with a proximal humeral fracture treated by locking plate fixation were confirmed on DEXA scanning to be osteopaenic (17), osteoporotic (4) or severely osteoporotic (2). Patients early in the series were reviewed retrospectively and recalled for an updated assessment where appropriate, and the remainder were followed prospectively. The average age was 66 years (range 49 to 82). Follow up was for an average of nine months following surgery (range 2 and a half to 28 months). 17 patients underwent surgery for acute injuries and 6 for established surgical neck non-unions. Seven injuries were 2-part fractures, 12 3-part, 3 were 4-part and one a 2-part surgical neck non-union.1 plate failed due to complete loss of fixation within 2 months in a patient with severe osteoporosis and was treated with removal of metalwork. This was the only injury that failed to unite. Avascular necrosis occurred in three patients with two revised to a hemiarthroplasty. 1 patient had ongoing pain and underwent removal of the plate. Our series demonstrated that locking plate fixation of proximal humeral fractures is associated with a low rate of fixation failure and satisfactory outcomes in patients with significantly reduced bone mineral density


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 18 - 18
1 Mar 2021
Babel H Omoumi P Jolles B Favre J
Full Access

While knee osteoarthritis (OA) is now recognized as a complex disease affecting the whole joint, not just the cartilages, there remains a paucity of data regarding the interactions between knee components. One relationship of particular interest is between the spatial variations in cartilage thickness (CTh) and subchondral bone mineral density (BMD). Indeed, bone and cartilage are two mechanosensitive tissues that interact as a functional unit and there is evidence of a biomechanical coupling between both tissues. Particularly, a recent in vivo study has shown a positive relationship in non-OA knees with thicker cartilage where bone is denser, and an alteration of this relationship in OA knees. These observations support the concept of an osteochondral unit and warrant additional research to assess the influence of bone depth. Therefore, this study aimed to characterize the relationship between spatial variations in CTh and BMD measured at various depths below the bone surface.

CT-arthrography of 20 non-OA tibias and 20 severe medial-compartment OA tibias were segmented to build 3D mesh models of the bones and cartilages. Each individual tibia model was registered to a reference tibia, allowing to calculate BMD maps at 1, 3, 5 and 10mm below the bone-cartilage interface in the medial compartment. Pearson correlations between CTh maps and the four BMD maps were then calculated for each knee. Lastly, differences in correlation coefficients between successive bone layers were assessed using Wilcoxon signed-rank tests.

In both OA and non-OA tibias, the correlation coefficients were higher with the BMD measured in the 1mm layer, and followed a pattern of statistically significant decrease with bone layers of increasing depth (p < 0.021). In non-OA tibias, the median relationship was positive with a strong effect size in the 1, 3 and 5mm layers, while in OA tibias the median relationship was positive only in the 1mm layer and with a medium effect size. In the OA tibias, the median relationship was negative with a weak effect size in the 3 and 5mm layers, and it was negative with a medium effect size in the 10mm layer.

In conclusion, the results of the present study support the value of considering bone and cartilage as a unit, and more generally support OA pathophysiology models based on relationships among knee properties.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 2 | Pages 283 - 288
1 Mar 2001
Wilkinson JM Peel NFA Elson RA Stockley I Eastell R

We aimed to evaluate the precision and longitudinal sensitivity of measurement of bone mineral density (BMD) in the pelvis and to determine the effect of bone cement on the measurement of BMD in femoral regions of interest (ROI) after total hip arthroplasty (THA). A series of 29 patients had duplicate dual-energy x-ray absorptiometry (DXA) scans of the hip within 13 months of THA. Pelvic analyses using 3- and 4-ROI models gave a coefficient of variation (CV) of 2.5% to 3.6% and of 2.5% to 4.8%, respectively. Repeat scans in 17 subjects one year later showed a significant change in BMD in three regions using the 4-ROI model, compared with change in only one region with the 3-ROI model (p < 0.05). Manual exclusion of cement from femoral ROIs increased the net CV from 1.6% to 3.6% (p = 0.001), and decreased the measured BMD by 20% (t = 12.1, p < 0.001). Studies of two cement phantoms in vitro showed a small downward drift in bone cement BMD giving a measurement error of less than 0.03 g/cm. 2. /year associated with inclusion of cement in femoral ROIs. Changes in pelvic periprosthetic BMD are best detected using a 4-ROI model. Analysis of femoral ROI is more precise without exclusion of cement although an awareness of its effect on the measurement of the BMD is needed


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 7 | Pages 1065 - 1071
1 Sep 2000
Martini F Lebherz C Mayer F Leichtle U Kremling E Sell S

Our aim was to determine the precision of the measurements of bone mineral density (BMD) by dual-energy x-ray absorptiometry in the proximal femur before and after implantation of an uncemented implant, with particular regard to the significance of retro- and prospective studies. We examined 60 patients to determine the difference in preoperative BMD between osteoarthritic and healthy hips. The results showed a preoperative BMD of the affected hip which was lower by a mean of 4% and by a maximum of 9% compared with the opposite side. In addition, measurements were made in the operated hip before and at ten days after operation to determine the effect of the implantation of an uncemented custom-made femoral stem. The mean increase in the BMD was 8% and the maximum was 24%. Previous retrospective studies have reported a marked loss of BMD on the operated side. The precision of double measurements using a special foot jig showed a modified coefficient of variation of 0.6% for the non-operated side in 15 patients and of 0.6% for the operated femur in 20 patients. The effect of rotation on the precision of the measurements after implantation of an uncemented femoral stem was determined in ten explanted femora and for the operated side in ten patients at 10° rotation and in 20 patients at 30° rotation. Rotation within 30° influenced the precision in studies in vivo and in vitro by a mean of 3% and in single cases in up to 60%. Precise prediction of the degree of loss of BMD is thus only possible in prospective cross-sectional measurements, since the effect of the difference in preoperative BMD, as well as the apparent increase in BMD after implantation of an uncemented stem, is not known from retrospective studies. The DEXA method is a reliable procedure for determining periprosthetic BMD when positioning and rotation are strictly controlled