Advertisement for orthosearch.org.uk
Results 1 - 20 of 439
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 76 - 76
1 May 2016
Kaneyama R Higashi H Shiratsuchi H Oinuma K Miura Y Tamaki T
Full Access

Introduction. The conventional bone resection technique in TKA is recognized as less accurate than computer-assisted surgery (CAS) and patient-matched instrumentation (PMI). However, these systems are not available to all surgeons performing TKAs. Furthermore, it was recently reported that PMI accuracy is not always better than that of the conventional bone resection technique. As such, most surgeons use the conventional technique for distal femur and proximal tibia resection, and efforts to improve bone resection accuracy with conventional technique are necessary. Here, we examined intraoperative X-rays after bone resection of the distal femur and proximal tibia with conventional bone resection technique. If the cutting angle was not good and the difference from preoperative planning was over 3º, we considered re-cutting the bone to correct the angle. Methods. We investigated 117 knees in this study. The cutting angle of the distal femur was preoperatively determined by whole-length femoral X-ray. The conventional technique with an intramedullary guide system was used for distal femoral perpendicular resection to the mechanical axis. Proximal tibial cutting was performed perpendicular to the tibial shaft with an extramedullary guide system. The cutting angles of the distal femur and proximal tibia were estimated by intraoperative X-ray with the lower limb in extension position. When the cutting angle was over 3º different from the preoperatively planned angle, re-cutting of distal femur or proximal tibia was considered. Results. On the intraoperative X-ray, the average femoral cutting angle difference from preoperative planning was 0.1º (SD: 2.6º) and the average tibial cutting angle was 1.1º varus (SD: 1.8º). Over 3º and 5º outlier cases were observed in 15 knees and 5 knees on the femoral side and in 15 knees and 3 knees on the tibial side respectively. Cutting angle correction was performed in 18 knees on the distal femur and 17 knees on the proximal tibia. On the postoperative X-ray, over 3º and 5º outliers were observed in 16 knees and only 1 knee on the femoral side and in 11 knees and no cases on the tibial side respectively. Cases with outliers over 3º were not different between intra- and postoperative estimation; however, the number of over 5º outliers was decreased from 8 knees (6.8%) to 1 knee (0.9%) including both the femoral and tibial sides (p < 0.05, Chi-square test). Discussion. Precise bone cutting technique is important for TKA; however, the bone resection accuracy of the conventional technique is far from satisfactory. CAS, PMI, and portable navigation have been developed for precise bone resection in TKA. However, these new technologies involve additional cost and have not been clearly shown to improve accuracy. Most surgeons currently use the conventional technique, and we think it is possible to improve bone resection accuracy with the conventional technique in TKA. Our method is simple and requires just one intraoperative X-ray. This is cost-effective and can be performed by most surgeons. Our results indicate that a single intraoperative X-ray can reduce the number of excessive bone resection angle outliers in TKA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 15 - 15
1 Feb 2017
Higashi H Kaneyama R Shiratsuchi H Oinuma K Miura Y Tamaki T Jonishi K Yoshii H
Full Access

Objective. In a cruciate retaining total knee arthroplasty (CR-TKA) for patients with flexion contracture, to ensure that an extension gap is of sufficient size to install an implant, the amount of distal femur bone resection needed is frequently larger in a patient with knee flexion contracture than in one without contracture. In this study, we compared the distal femur bone resection amount, the component-secured extension gap margin value, and the range of motion at 6 months after surgery between patients with knee flexion contracture and those without knee flexion contracture. Method. We examined 51 joints including 27 joints in patients with preoperative extension limitation of less than 5 degrees (the F0 group) and 24 joints in patients with limitation of 15 degrees or larger (up to 33 degrees; the FC group) who underwent CR-TKA with LCS RP (DePuy Synthes) between May 2013 and April 2014. In case with an extension gap 3 mm or smaller than the flexion gap after initial bone resection, we released posterior capsule adequately, trying to minimize the distal femur additional bone resection amount as possible. With installation of a femoral trial, the component gaps were measured using spacer blocks. The measured parameters included the intraoperative bone resection length, gap difference (FG − EG, i.e., difference between the flexion gap [FG] and extension gap [EG]), and range of motion 6 months after surgery. Results. No inter-group difference was found in the length of the distal femur bone initially resected in the medial side of distal femur(F0: 6.7 ± 1.3 mm, FC: 6.1 ± 1.4 mm) and total length of bone resection (= first + additional resection) in the lateral proximal tibia (F0: 10.3 ± 1.9 mm, FC: 10.4 ± 2.1 mm). The length of the additional distal femur bone resected was 0.9 ± 1.3 mm in the F0 and 1.5 ± 1.2 mm in the FC (P = 0.06; Mann-Whitney U). The FG-EG (F0: 0.7 ± 0.9 mm, FC: 0.6 ± 0.8 mm) showed no remarkable inter-group difference. The mean range of motion was changed from −2.3° to −0.6° at extension and from 130.4° to 128.7° at flexion in the F0 and from −19.8° to −2.7° at extension and from 113.7° to 122.3° at flexion in the FC. Conclusions. The amount of distal femur bone resected should not be simply increased because this may elevate the joint line, narrow the flexion range, and cause the joint instability in mid-flexion. The results of this study show that, in CR-TKA for patients with flexion contracture up to 30°, the length of distal femoral bone resection of approximately 1 mm larger than that in patients without contracture may ensure an extension gap of necessary and sufficient length to install an implant


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 231 - 231
1 May 2009
Lavigne M Nuno N Plamondon D Vendittoli PA Winzenrieth R
Full Access

To compare the volume of acetabular bone resection after primary hip arthroplasty with different cup designs and technique of implantation using a computer model. The factors influencing acetabular bone resection during acetabular cup implantation in THA or hip resurfacing (SRA) include the design of the component and technique of implantation. The impact of these variables on bone resection was simulated with a computer model. A 3-D pelvis was reconstructed from CT scan images. The bony acetabulum circumference was 52.5mm. Implantation of pressfit acetabular component sustaining angles of 165°, 170° and 180° with different wall thicknesses (3.5, 4.0, 5.0mm) at various depths was simulated. Bone loss of 2742mm3 was calculated for the 165°, 4mm thick, 54mm cup, and deepening of reaming by 1 and 2mm would result in bone loss of 3780mm3 (+38%) and 5076mm3 (+85%), respectively. When oversizing to a 56mm 165° component, 4998mm3 (+82%) of bone was removed. For a 54mm, 5 mm thick component sustaining an angle of 180°, the bone loss would reach 12 410mm3 (+450%). Acetabular component design has a significant influence on the amount of acetabular bone resection. The surgical technique (avoiding over deepening and oversised components) should minimise bone loss. This knowledge is of particular importance in hip resurfacing since the acetabular component size depends on the selected femoral component size. The knowledge is is also important in THA to minimise bone loss at primary implantation


Bone & Joint Open
Vol. 5, Issue 8 | Pages 681 - 687
19 Aug 2024
van de Graaf VA Shen TS Wood JA Chen DB MacDessi SJ

Aims. Sagittal plane imbalance (SPI), or asymmetry between extension and flexion gaps, is an important issue in total knee arthroplasty (TKA). The purpose of this study was to compare SPI between kinematic alignment (KA), mechanical alignment (MA), and functional alignment (FA) strategies. Methods. In 137 robotic-assisted TKAs, extension and flexion stressed gap laxities and bone resections were measured. The primary outcome was the proportion and magnitude of medial and lateral SPI (gap differential > 2.0 mm) for KA, MA, and FA. Secondary outcomes were the proportion of knees with severe (> 4.0 mm) SPI, and resection thicknesses for each technique, with KA as reference. Results. FA showed significantly lower rates of medial and lateral SPI (2.9% and 2.2%) compared to KA (45.3%; p < 0.001, and 25.5%; p < 0.001) and compared to MA (52.6%; p < 0.001 and 29.9%; p < 0.001). There was no difference in medial and lateral SPI between KA and MA (p = 0.228 and p = 0.417, respectively). FA showed significantly lower rates of severe medial and lateral SPI (0 and 0%) compared to KA (8.0%; p < 0.001 and 7.3%; p = 0.001) and compared to MA (10.2%; p < 0.001 and 4.4%; p = 0.013). There was no difference in severe medial and lateral SPI between KA and MA (p = 0.527 and p = 0.307, respectively). MA resulted in thinner resections than KA in medial extension (mean difference (MD) 1.4 mm, SD 1.9; p < 0.001), medial flexion (MD 1.5 mm, SD 1.8; p < 0.001), and lateral extension (MD 1.1 mm, SD 1.9; p < 0.001). FA resulted in thinner resections than KA in medial extension (MD 1.6 mm, SD 1.4; p < 0.001) and lateral extension (MD 2.0 mm, SD 1.6; p < 0.001), but in thicker medial flexion resections (MD 0.8 mm, SD 1.4; p < 0.001). Conclusion. Mechanical and kinematic alignment (measured resection techniques) result in high rates of SPI. Pre-resection angular and translational adjustments with functional alignment, with typically smaller distal than posterior femoral resection, address this issue. Cite this article: Bone Jt Open 2024;5(8):681–687


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 143 - 143
1 Apr 2019
Nizam I Batra A
Full Access

BACKGROUND. We conducted this study to determine if the pre-surgical patient specific instrumented planning based on Computed tomography scans can accurately predict each of the femoral and tibial resections. The technique helps in optimization of component positioning and hence overall alignment thereby reducing errors. This makes it less invasive, more efficient and cost effective. The surgical plan in combination with the cutting guides determine the resection thickness, component size, femoral rotation and femoral and tibial component alignment. Several clinical studies have shown that PSI is safe, accurate and reproducible in primary TKA. Accurate preparation of the femoral and tibial surfaces will determine alignment and component positioning and this in turn reflects on function and longevity. METHODS. The study was conducted prospectively between May 2016 and December 2017 in our institution. Patients admitted over a period of these twenty months were included in the study. Patients with primary or secondary osteoarthritis (OA) and inflammatory arthritis who were suitable to undergo patient-specific TKA were included in the study. Patients with conventional instrumented TKR and those with significant deformities requiring constrain including valgus or varus of greater than 20 degrees with incompetent lateral or medial collateral ligaments were excluded from the study along with revisions of partial knee to TKA using PSI blocks. Prophecy® Preoperative Navigation 3D printed Guides were used for the Evolution Medial Pivot knee replacement system (. Microport Orthopaedics (Arlington, TN 38002, USA)). in all cases. The operating surgeon measured all the resections made (4 femoral and 2 tibial) using vernier calipers intraoperatively. These measurements were then compared with the preoperative CT predicted bone resection surgical planning. The senior author (IN) also designed markings on the tibial cutting blocks to improve accurate placement on the tibia and further markings on the femoral cutting blocks to ensure accurate positioning and rotational alignment improving accuracy of the cuts and femoral rotation. Further markings by senior surgeon (IN) on the pre-operative plans included tibial rotational plans in relation to the tibial tubercle. RESULTS. A total of 3618 readings were calculated from 201 knees (105 right and 96 left). There were 112 females and 76 males, and the average age was 67.72 years (44 to 90 years) and average BMI 32.3 (25.1 to 42.3). The surgical time ranged from 46 to 102 minutes with a mean operating time of 62 minutes. All Femoral and Tibial blocks sat accurately on the bony surfaces before being pinned. 94% of all collected resection readings were below the error margin of ≤1.5 mm of which 90% showed resection error of ≤1mm. Mean error of different resections were ≤0.60 mm (P ≤ 0.0001). In 24% of measurements there were no errors or deviations from the templated resection (0.0 mm). CONCLUSION. The 3D printed cutting blocks with slots for jigs accurately predict bone resections in PSI total knee arthroplasty which would directly affect component positioning and hence longevity and function


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 209 - 209
1 Mar 2013
Kaneyama R Shiratsuchi H Oinuma K Miura Y Tamaki T
Full Access

Introduction. Although, the total knee arthroplasty (TKA) procedure is performed to make the same extension gap (EG) and flexion gap (FG) of the knee, it is not clear how the gaps can be created equally. According to earlier reports, the gaps after bone resection (bone gaps) differ from the gaps after the trial component of the femur is set (component gaps), because of the thickness of the posterior condyle of the femoral component and the tension of the posterior capsule. The surgeon can only check the component gaps after completing the bone resection and setting the trial component and it difficult to adjust the gaps even when the acquired component gaps are inadequate. To resolve this problem, we developed a “pre-cut trial component” for use in a pre-cut technique for the femoral posterior condyle (Fig. 1). This specially made trial component allows us to check the component gaps before the final bone resection of the femur. Materials and methods. The pre-cut trial component is composed of an 8-mm-thick usual distal part and a 4-mm-thick posterior part of the femoral component, and lacks an anterior part of the femoral component. With this pre-cut trail component, 152 knees were investigated. The EG was made by standard resection of distal femur and proximal tibia. The FG was made by a 4 mm pre-cut from the posterior condylar line of the femoral posterior condyle (Fig. 2). The rotation of the pre-cut line is initially decided by anatomical landmarks. Once all of the osteophytes are removed and the bone gaps are checked, the pre-cut trial component is attached to the femur and the component gaps are estimated with the patella reduction (Fig. 3). In our experiments, these gaps were the same as the component gaps after the usual trial component was set via the measured resection technique. Finally, the femur is completely resected according to the measurements of the component gaps with the pre-cut trial component. Results. The bone gaps were 18.4±2.4 (mean ± standard deviation) mm in extension and 16.5±2.7 mm in flexion. From these results, the expected component gaps were 10.8±2.7 (bone gap −8) mm in extension and 12.5±2.7 (bone gap −4) mm in flexion. After the pre-cut trial component was set, the measured component gaps were 9.4±2.8 mm in extension and 12.5±2.8 mm in flexion. The EG became 1.5±1.0 mm smaller than expected, and the change of FG was 0.2±0.5 mm. While no large decrease of EG was noted, the variation was not insubstantial (0∼5 mm). Conclusion. The difference between the bone gap and component gap is very important for an adequate EG and FG in the TKA procedure. Yet with the conventional technique, the component gap is impossible to estimate before the final bone resection. If unacceptable results are discovered after the component gaps are estimated, the gaps are difficult to correct. With the technique we present here, the component gaps can be checked before final bone resection and truly precise gap control can be attained


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 77 - 77
1 Aug 2013
Changulani M Deakin A Picard F
Full Access

Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and patellofemoral problems. The aim of this retrospective study was to establish the contribution of soft tissue releases and bony cuts in the change in maximum knee extension in TKA. Data were available for 209 navigated TKAs performed by a single surgeon using a medial approach. All patients had the same cemented implant, either CR or PS, which both required a minimum thickness of 10 mm for the tibial and 9mm for the femoral component. Intra-operatively pre- and post-implant extension angles and the size of bone resection were collected using a commercial navigation system. The thickness of polyethylene insert and the extent of soft tissue release performed (no release, moderate and extensive release) were collected from the patient record. A univariate linear regression model was used to predict change in maximum extension from pre- to post-implant. The mean bone resection was 19mm (15 to 28 mm) (Figure 1).79% of polyethylene inserts were 10mm thick (10 to 16 mm). 71% of knees had no soft tissue release. The mean increase in extension was 5° (11° decrease to 23° increase) (Figure 1). The analysis showed that bone cuts (p<0.001), soft tissue release (p=0.001) and insert thickness (p=0.010) were all significant terms in the model (r. 2. adj. =0.170). This model predicted that carrying out a TKA with 19mm bone cuts, 10mm insert and no soft tissue release would give 4.2° increase in extension. It predicted that a moderate release would give a 2.8° increase in extension compared to no release, with an extensive release giving 3.9° increase over no release. For each mm increase in bone cuts the model predicted a 0.8° increase in extension and for each mm increase in insert size a decrease extension by 1.1°. Preoperative FFC contracture is a frequent condition in TKA that the surgeon has to address either by resecting more bone or by extending soft tissue release to increase the extension gap to fit the knee implant. This analysis of 209 navigated knee arthroplasty showed that both options are suitable to increase the extension gap. The modelling results show that in general to increase maximum extension by the same as an extensive soft tissue release that bone cuts would have to be increased by 4–5mm. However this model only accounted for 17% of the variation in change in extension pre- to post-implant so is poor at predicting outcomes for specific patients. The large variation in actual FFC correction indicates that this relies on factors other than bone cuts and soft tissue releases as quantified in this study


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 602 - 602
1 Oct 2010
Hiz M Dervisoglu S Ozyer F Tenekecioglu Y Unlu M Ustundag S
Full Access

Purpose: Local resection with or without irradiation is the primary treatment modality of soft tissue sarcomas. Adequate surgical margin is required for local tumour control and avoiding local recurrence. Adjacent bone should be included into the resection plan if the tumour is in the close proximity of the bone or cortical and medullary tumour invasion was present. Reconstruction method depends on the location. Methods: 25 patient (10 female, 15 male) with soft tissue sarcomas received local wide excision including adjacent bone between 1995–2007. Histological types were 3 MPNSTM, 3MFH, 10 Synovial sarcoma, 2 liposarcoma, 4 angiosarcoma, 2 fibrosarcoma, 1 Leiomyosarcoma. Localisations were 5 glutea, 9 thigh, 5 cruris, 1 forearm, 5 foot. In 8 patients with proximal bone resection including the joint surface prosthetic reconstruction were aplied. 6 Patients with intercalary resections required allograft reconstruction with I.M nail, 2 patients required autoclaved graft, 1 patient needed tricortical iliac autograft. 8 patients in the gluteal region required iliac and sacral resections without any bony reconstruction. 25 patient received irradiation. 16 of them had neoadjuant chemotherapy also. Results: At mean 64 mo.s follow up (min11–max159). Mean age was 44, 5 (min 18–max 71). Oncologically 17 patients were NED, 1 AWD, 7 DOD (2 with local recurrence). Regarding complications 7 patients developed local recurrence, 2 patient developed infection, 2 patient had developed wound healing. 5 of 7 local recurrences were amputated. 2 of them died of the disease. 2 local recurrences could be re-resected. Delayed wound healing and infection occured in the patients received preoperative chemotherapy and irradiation. Conclusion: If a large soft tissue sarcoma is in the close proximity of an adjacent bone or had cortical or medullary invasion, adjacent bone must be included in the resection plan so that a wide margin could be achieved. Reconstruction of the created bone defect in the weight bearing bone close to a major joint should be prosthetic reconstruction. Allograft reconstruction is recommended in the foot and upper extrimity. A thorough preoperative plan with appropriate imaging should be done and local resection should be performed precisely to achieve satisfactory wide margin which influences the both local and systemic outcome


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 43 - 43
1 Aug 2013
Changulani M Sankar B Deakin A Picard F
Full Access

Distal femur resection for correction of flexion contractures in total knee arthroplasty (TKA) can lead to joint line elevation, abnormal knee kinematics and patellofemoral problems. The aim of this retrospective study was to establish the contribution of soft tissue releases and bony cuts in the change in maximum knee extension in TKA. Data were available for 211 TKAs performed by a single surgeon using a medial approach. Intra-operatively pre- and post-implant extension angles and the size of bone resection were collected using a commercial navigation system. The thickness of polyethylene insert and the extent of soft tissue release performed (no release, moderate and extensive release) were collected from the patient record. A linear model was used to predict change in maximum extension from pre- to post-implant. The analysis showed that bone cuts (p<0.001), soft tissue release (p=0.001) and insert thickness (p=0.010) were all significant terms in the model (r. 2. adj. =0.170). This model predicted that carrying out a TKA with 19 mm bone cuts, 10 mm insert and no soft tissue release would give 4.2° increase in extension. It predicted that a moderate release would give a further 2.8° increase in extension with an extensive release giving 3.9°. For each mm increase in bone cuts the model predicted an 0.8° increase in extension and for each mm increase in insert size a decrease extension by 1.1°. The modelling results show that in general to increase maximum extension by the same as an extensive soft tissue release that bone cuts would have to be increased by 4–5 mm. However this model only accounted for 17% of the variation in change in extension pre- to post-implant so may not be accurate at predicting outcomes for specific patients


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 237 - 237
1 Jul 2008
GAY A LEGRÉ R JOUVE J GLARD Y LAUNAY F BOLLINI G
Full Access

Purpose of the study: Assessment of limb reconstruction results using vascularized fibular grafts after bony resection for malignant tumors in children. Material and methods: Thirty children (9 girls and 21 boys)underwent surgery between 1993 and 2000. Mean age was 11 years. Tumor localizations were: femur (n=17), tibia (n=6), humerus (n=5), radius (n=1) and distal ulna (n=1). Mean length of bone resection was 16 cm (range 10–26 cm). For 22 children, the adjacent epiphysis was preserved. For the eight others, fusion was also performed. Two surgical teams operated sequentially: the first team performed the tumor resection and the second (an orthopedist for the osteosynthesis and a plastician for the vascularized fibular transfer) the limb reconstruction. Radiographic and clinical assessment was completed with bone scintigraphy. The index of graft hypertrophy was determined with the De Boer and Wood method. Functional outcome was assessed with Enneking criteria. Results: Mean follow-up was 51 months (range 2 – 9 years). Early amputation was necessary for two children due to local oncological complications. One patient died of pulmonary metastasis eight months after limb reconstruction. Among the 27 other patients, primary healing was achieved in 22. In the five with primary nonunion, bone scintigraphy showed objective signs of a lack of blood supply to the graft. Secondary union was achieved with a complementary autologous bone graft in four cases. All cases of stress fracture healed with orthopedic treatment. For the 22 patients with primary union, the graft hypetrophy was 22–190% (mean 61%). For the five patients without bone vascularization on the scintigraphy, the fibular graft failed to hypertrophy. Functional outcome was satisfactory. The modified Enneking score (30 point scale) was 26 (range 19–30 points). Discussion: Limb reconstruction results are directly related to good patency of vascular anastomoses. Postoperative bone scintigraphy is useful to determine blood supply to the graft and to establish the final prognosis. In the case of vascular failure, an autologous bone graft can be proposed early to enable union. Close collaboration between the plastic surgery and the orthopedic team is the key to successful limb reconstruction with a vascularized fibular graft


The Bone & Joint Journal
Vol. 106-B, Issue 10 | Pages 1039 - 1043
1 Oct 2024
Luo TD Kayani B Magan A Haddad FS

The subject of noise in the operating theatre was recognized as early as 1972 and has been compared to noise levels on a busy highway. While noise-induced hearing loss in orthopaedic surgery specifically has been recognized as early as the 1990s, it remains poorly studied. As a result, there has been renewed focus in this occupational hazard. Noise level is typically measured in decibels (dB), whereas noise adjusted for human perception uses A-weighted sound levels and is expressed in dBA. Mean operating theatre noise levels range between 51 and 75 dBA, with peak levels between 80 and 119 dBA. The greatest sources of noise emanate from powered surgical instruments, which can exceed levels as high as 140 dBA. Newer technology, such as robotic-assisted systems, contribute a potential new source of noise. This article is a narrative review of the deleterious effects of prolonged noise exposure, including noise-induced hearing loss in the operating theatre team and the patient, intraoperative miscommunication, and increased cognitive load and stress, all of which impact the surgical team’s overall performance. Interventions to mitigate the effects of noise exposure include the use of quieter surgical equipment, the implementation of sound-absorbing personal protective equipment, or changes in communication protocols. Future research endeavours should use advanced research methods and embrace technological innovations to proactively mitigate the effects of operating theatre noise.

Cite this article: Bone Joint J 2024;106-B(10):1039–1043.


Bone & Joint Research
Vol. 11, Issue 4 | Pages 226 - 228
20 Apr 2022
Hiranaka T Suda Y Saitoh A Koide M Tanaka A Arimoto A Fujishiro T Okamoto K


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1642 - 1645
1 Nov 2021
Kayani B Giebaly D Haddad FS


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 2 | Pages 315 - 316
1 Mar 1992
Huber H


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 13 - 13
1 May 2016
Bozkurt M Tahta M Gursoy S Akkaya M
Full Access

Objective

In this study, we aim to compare total bone amount extracted in total knee arthroplasty in implant design and the bone amount extracted through intercondylar femoral notch cut.

Material and Method

In this study, we implemented 10 implants on a total of 50 sawbones from 5 different total knee arthroplasty implant brands namely Nex-Gen Legacy (Zimmer, Warsaw, IN, USA), Genesis 2 PS (Smith&Nephew, Memphis, TN, USA), Vanguard (Biomet Orthopedics Inc., Warsaw, IN, USA), Sigma PS (De Puy, Johnson&Johnson, Warsaw, IN, USA), Scorpio NRG PS (Stryker Co., Kalamazoo, USA). Equal or the closest sizes of each brand on anteroposterior plane were selected, and cuts were made following standard technique(see Fig 1 and 2). Extracted bone pieces were measured in terms of volume and length on three planes, and statistically analysed. The volume of all pieces available after each femoral incision was measured according to Archimedes’ principles. Furthermore, the volume of each intercondylar femoral notch pieces was measured separately from other pieces but with the same method. The measurement of intercondylar femoral notch pieces on 3 planes (medial-lateral, anterior-posterior, superior-inferior) was made using Kanon slide gauge (Ermak Ltd, Istanbul, TR). Femoral notch incision pieces were scanned with CAD/CAM technology using three-dimensional scanner 1 SeriesTM (Dental Wings Inc, Montreal, QC, Canada), and the measurements were confirmed with DWOS CAD 4.0.1 software (Dental Wings Inc, Montreal, QC, Canada)(see figure 3a-e). The volume of 10 intercondylar femoral notch pieces performed through the set of each brand was averaged, and considered as the incision volume of that particular brand.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 29 - 29
1 Jun 2023
McCabe F Wade A Devane Y O'Brien C McMahon L Donnelly T Green C
Full Access

Introduction. Aneurysmal bone cysts commonly found in lower limbs are locally aggressive masses that can lead to bony erosion, instability and fractures. This has major implications in the lower limbs especially in paediatric patients, with potential growth disturbance and deformity. In this case series we describe radical aneurysmal bone cyst resection and lower limb reconstruction using cable transport and syndesmosis preservation. Materials & Methods. Case 1 - A 12-year-old boy presented with a two-week history of atraumatic right ankle pain. An X-ray demonstrated a distal tibia metaphyseal cyst confirmed on biopsy as an aneurysmal bone cyst. The cyst expanded on interval X-rays from 5.5cm to 8.5cm in 9 weeks. A wide-margin en-bloc resection was performed leaving a 13.8cm tibial defect. A cable transport hexapod frame and a proximal tibial osteotomy was performed, with syndesmosis screw fixation. The transport phase lasted 11 months. While in frame, the boy sustained a distal femur fracture from a fall. The femur and the docking site were plated at the same sitting and frame removed. At one-year post-frame removal he is pain-free, with full ankle dorsiflexion but plantarflexion limited to 25 degrees. He has begun graduated return to sport. Results. Case 2 - A 12-year-old girl was referred with a three-month history of lateral left ankle swelling. X-ray demonstrated an aneurysmal bone cyst in the distal fibula metaphysis. The cyst grew from 4.2 × 2.3cm to 5.2 × 3.32cm in 2 months. A distal fibula resection (6.2cm) with syndesmosis fixation and hexapod cable transport frame were undertaken. The frame was in situ for 13 weeks and during this time she required an additional osteotomy for premature consolidation and had one pin site infection. After 13 weeks a second syndesmosis screw was placed, frame removed, and a cast applied. 3 months later she had fibular plating, BMAC and autologous iliac crest bone graft for slow union. At 3 years post-operative she has no evidence of recurrence, is pain-free and has no functional limitation. Conclusions. We describe two cases of ankle syndesmosis preservation using cable transport for juxta-articular aneurysmal bone cysts. This allows wide resection to prevent recurrence while also preserving primary ankle stability and leg length in children. Both children had a minor complication, but both had an excellent final outcome. Cable bone transport and prophylactic syndesmosis stabilization allows treatment of challenging juxta-articular aneurysmal bone cysts about the ankle. These techniques are especially useful in large bone defects


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 147 - 148
1 Mar 2008
Whitehead T Willits K Bryant D Fowler P Giffin R
Full Access

Purpose: To compare lateral closing to medial opening wedge HTO for a similar angle of correction with regard to change in proximal tibial bony anatomy and posterior cruciate ligament tibial attachment integrity following standard tibial arthroplasty resection.

Methods: Ten cadaveric lower limbs were randomized by side to receive a 12° lateral closing or 12.5mm medial opening wedge HTO. Anteroposterior, lateral and long leg AP radiographs were performed before and after each osteotomy. Pre and post osteotomy measurements of the coronal proximal tibial angle (PTA), sagittal tibial slope and anatomical femorotibial angle were completed and change in angles calculated. Prior to osteotomy, the tibial PCL attachment area was calculated. Post osteotomy, a standardized tibial arthroplasty resection was performed and the remaining percentage PCL attachment area recorded.

Results: Initial radiographs demonstrated little variation between matched pairs. Compared to the medial opening wedge group, the lateral closing wedge specimens demonstrated a statistically significant greater mean change in the PTA of 3.5° (95% C.I., 2.0 to 5.1°, p = 0.003) and an overall tendency for posterior tibial slope reduction with a mean change of −3.4 ± 4.9°. The average osteotomy angle in the medial opening wedge specimens was 11.9 ± 0.7°. Following tibial arthroplasty resection, there was a significant difference in the remaining PCL tibial attachment percentage area of 84.6 ±14.9 % for medial opening wedge and 50.8 ± 19.3 % for lateral closing wedge for a statistically significant mean difference of 33.8 % (95% C.I. 5.1 to 62.4, p = 0.031).

Conclusions: Despite similar correction angles of 12° for lateral closing and 11.9° for medial opening, the former specimens demonstrated a greater alteration in proximal tibial bony anatomy compared to the latter. In the lateral closing wedge group, the tendency to reduce posterior tibial slope and produce a greater than anticipated change in PTA had a significant effect on the integrity of the PCL’s tibial attachment following tibial arthroplasty resection.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 93 - 93
1 Mar 2009
Bianchi G Donati D Di Bella C Colangeli M Colangeli S Mercuri M
Full Access

Introduction: The use of allograft prosthetic composite (APC) of the proximal tibia offers advantages over prosthetic replacement or osteoarticular graft with a better functional outcome since the possibility of a careful soft tissue reconstruction;. Materials and Methods: From 1994 to 2002, 62 APC of the proximal tibia were performed in our department after bone tumor resection (56 malignant bone tumors, 4 cases of previously failed knee implant and 2 stage 3 benign tumors). The patients median age was 18 yrs (range: 11–77 yrs) and the mean resected length was 13.2 cm (range: 8.5–28 cm). The median follow up was 59 months (range: 13–137 months). Results: In three patients (4,8%) a recurrence was reported at 22, 33 an 40 months and amputation was performed. Infection was reported in 15 patients (24.2%): 2 early infections (healed with surgical debridment), 1 femoral stem septic loosening (treated with early revision with cemented stem); in 8 cases removal of the infected APC was required followed by implant of a new prosthetic device after cement spacer; two infections did not healed and patient underwent amputation; in two cases a good functional result was achieved removing the infected graft and covering the proximal tibia with cement and no other surgery was required. Non union of the graft was observed in 8 patients (12.9%): in 4 patients autologous bone grafting was necessary to heal the osteotomy line. In other 3 cases non union was associated with graft fracture. In one case non union was associated with tibial stem loosening and revision of the whole implant was done. Polyethylene wear was assessed in 5 patients (8%) and revision of the polyethylene components was always required. Nine patellar tendon rupture (14.5%) were assessed and repaired was performed in seven cases. The functional outcome of 42 patients with more than two years of follow up was excellent in 25 cases, good in 13, fair in 2 and poor in 2. Discussion: APC of the proximal tibia is an effective alternative to osteoarticular graft and modular prosthesis because it allows good to excellent results in most of the patients (90.4%). The major concern is infection rate (24.2%) that usually lead to amputation (80%). Non union does not usually represent a problem because it’s tendency to spontaneous or bone grafting induced healing. Aseptic loosening of the tibial or femoral stem is rare. Patellar tendon rupture rate (14.5%) is similar to modular prosthetis rate and can be lowered using a femoral component with patellar groove


Bone & Joint Research
Vol. 12, Issue 1 | Pages 22 - 32
11 Jan 2023
Boschung A Faulhaber S Kiapour A Kim Y Novais EN Steppacher SD Tannast M Lerch TD

Aims. Femoroacetabular impingement (FAI) patients report exacerbation of hip pain in deep flexion. However, the exact impingement location in deep flexion is unknown. The aim was to investigate impingement-free maximal flexion, impingement location, and if cam deformity causes hip impingement in flexion in FAI patients. Methods. A retrospective study involving 24 patients (37 hips) with FAI and femoral retroversion (femoral version (FV) < 5° per Murphy method) was performed. All patients were symptomatic (mean age 28 years (SD 9)) and had anterior hip/groin pain and a positive anterior impingement test. Cam- and pincer-type subgroups were analyzed. Patients were compared to an asymptomatic control group (26 hips). All patients underwent pelvic CT scans to generate personalized CT-based 3D models and validated software for patient-specific impingement simulation (equidistant method). Results. Mean impingement-free flexion of patients with mixed-type FAI (110° (SD 8°)) and patients with pincer-type FAI (112° (SD 8°)) was significantly (p < 0.001) lower compared to the control group (125° (SD 13°)). The frequency of extra-articular subspine impingement was significantly (p < 0.001) increased in patients with pincer-type FAI (57%) compared to cam-type FAI (22%) in 125° flexion. Bony impingement in maximal flexion was located anterior-inferior at femoral four and five o’clock position in patients with cam-type FAI (63% (10 of 16 hips) and 37% (6 of 10 hips)), and did not involve the cam deformity. The cam deformity did not cause impingement in maximal flexion. Conclusion. Femoral impingement in maximal flexion was located anterior-inferior distal to the cam deformity. This differs to previous studies, a finding which could be important for FAI patients in order to avoid exacerbation of hip pain in deep flexion (e.g. during squats) and for hip arthroscopy (hip-preservation surgery) for planning of bone resection. Hip impingement in flexion has implications for daily activities (e.g. putting on shoes), sports, and sex. Cite this article: Bone Joint Res 2023;12(1):22–32


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 63 - 63
22 Nov 2024
Madeira G Mateus RB Catelas D Contente J Rocha M Lucas J Nelas J Oliveira V Cardoso P Sousa R
Full Access

Aim. Megaprosthesis have become a standard option in limb preserving surgery after bone resection in musculoskeletal tumors. Recently they have also been used in complex revision arthroplasty in cases with massive bone loss. The aim of this study was to analyze the incidence of periprosthetic joint infection (PJI) both in primary oncology cases and aseptic revision cases and analyze which are the significant risk factors for PJI with a special interest on the use of prophylactic antibiotic loaded calcium sulfate beads. Method. All patients undergoing surgery with the use of megaprosthesis in our institution between January/2012 and December/2022 were retrospectively reviewed. Data was collected from electronic medical records. We identified 108 procedures involving megaprosthesis in 90 patients with an average follow-up of 37 months. Indications were 79 primary musculoskeletal tumors and 29 aseptic complex revision arthroplasty. Results. Table 1 shows relevant clinical information. No significant risk factor was found either in uni or multivariate analysis. PJI rate was 15% (12/79) for primary musculoskeletal surgery and 31% (9/29) for complex revision surgery. The use of antibiotic loaded calcium sulfate beads did not show an advantage – 22% (9/41) with vs. 18% (12/67) without. Conclusions. In this relatively small series it was not possible to show a significal association between PJI and certain known risk factors such as gender, ASA score, site of surgery (knee) and revision surgery. The use of antibiotic loaded calcium sulfate beads as prophylaxis was not beneficial in reducing PJI rates in our cohort. We acknowledge the limitations of our study: a small sample group, in a single institution with heterogeneity in terms of diagnosis and surgical site. We recognize the need for a multicentric study with a larger cohort to validate these findings. For any tables or figures, please contact the authors directly