Advertisement for orthosearch.org.uk
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 29 - 29
1 Mar 2021
Dalal S Aminake G Chandratreya A Kotwal R
Full Access

Abstract

Introduction

Long term survivorship in Total Knee Arthroplasty is significantly dependent on prosthesis alignment. The aim of this study was to determine, compare and analyse the coronal alignment of the tibial component of a single implant system using 3 different techniques.

Method

Retrospective study of cases from a prospectively collected database. Radiological assessment included measurement of the coronal alignment of tibial components of total knee arthroplasties, and its deviation from the mechanical axis. A comparison study of intramedullary, extramedullary and tibial crest alignment methods was performed.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 95 - 95
1 Jan 2017
Rivière C Shah H Auvinet E Iranpour F Harris S Cobb J Howell S Aframian A
Full Access

Trochlear geometry of modern femoral implants is designed for mechanical alignment (MA) technique for TKA. The biomechanical goal is to create a proximalised and more valgus trochlea to better capture the patella and optimize tracking. In contrast, Kinematic alignment (KA) technique for TKA respects the integrity of the soft tissue envelope and therefore aims to restore native articular surfaces, either femoro-tibial or femoro-patellar. Consequently, it is possible that current implant designs are not suitable for restoring patient specific trochlea anatomy when they are implanted using the kinematic technique, this could cause patellar complications, either anterior knee pain, instability or accelerated wear or loosening. The aim of our study is therefore to explore the extent to which native trochlear geometry is restored when the Persona®implant (Zimmer, Warsaw, USA) is kinematically aligned.

A retrospective study of a cohort of 15 patients with KA-TKA was performed with the Persona®prosthesis (Zimmer, Warsaw, USA). Preoperative knee MRIs and postoperative knee CTs were segmented to create 3D femoral models. MRI and CT segmentation used Materialise Mimics and Acrobot Modeller software, respectively. Persona®implants were laser scanned to generate 3D implant models. Those implant models have been overlaid on the 3D femoral implant model (generated via segmentation of postoperative CTs) to replicate, in silico, the alignment of the implant on the post-operative bone and to reproduce in the computer models the features of the implant lost due to CT metal artefacts. 3D models generated from post-operative CT and pre-operative MRI were registered to the same coordinate geometry. A custom written planner was used to align the implant, as located on the CT, onto the pre-operative MRI based model. In house software enabled a comparison of trochlea parameters between the native trochlea and the performed prosthetic trochlea. Parameters assessed included 3D trochlear axis and anteroposterior offset from medial facet, central groove, and lateral facet. Sulcus angle at 30% and 40% flexion was also measured. Inter and intra observer measurement variabilities have been assessed.

Varus-valgus rotation between the native and prosthetic trochleae was significantly different (p<0.001), with the prosthetic trochlear groove being on average 7.9 degrees more valgus. Medial and lateral facets and trochlear groove were significantly understuffed (3 to 6mm) postoperatively in the proximal two thirds of the trochlear, with greatest understuffing for the lateral facet (p<0.05). The mean medio-lateral translation and internal-external rotation of the groove and the sulcus angle showed no statistical differences, pre and postoperatively.

Kinematic alignment of Persona®implants poorly restores native trochlear geometry. Its clinical impact remains to be defined.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 129 - 129
1 Nov 2021
Vermue H Tack P Jan V
Full Access

Introduction and Objective. Total knee arthroplasty (TKA) is a frequently and increasingly performed surgery in the treatment of disabling knee osteoarthritis. The rising number of procedures and related revisions pose an increasing economic burden on health care systems. In an attempt to lower the revision rate due to component malalignment and soft tissue imbalance in TKA, robotic assistance (RA) has been introduced in the operating theatre. The primary objective of this study is to provide the results of a theoretical, preliminary cost-effectiveness analysis of RA TKA. Materials and Methods. A Markov state-transition model was designed to model the health status of sixty-seven-year-old patients in need of TKA due to primary osteoarthritis over a twenty-year period following their knee joint replacement. Transitional probabilities and independent variables were extracted from existing literature. Patients’ state in the transition model was able to change on an annual basis. The main differences between the conventional and RA TKA were the outlier rate in the coronal plane and the cost of the procedure. In RA TKA, it was hypothesized that there were lower revision rates due to a lower outlier rate compared to conventional TKA. Results. The value attributed to the utility both for primary and revision surgery has the biggest impact on the ICER, followed by the rate of successful primary surgery and the cost of RA-technology. Only 2.18–2.34% of the samples yielded from the probabilistic sensitivity analysis proved to be cost-effective (threshold set at $50000/QALY). A calculated surgical volume of at least 191–253 cases per robot per year is needed to prove cost-effective taking the predetermined parameter values into account. Conclusions. Robot-assisted TKA might be a cost-effective procedure compared to conventional TKA if a minimum of 191 cases are performed on a yearly basis, depending on the cost of the robot. The cost-benefit of the robotic TKA surgery is mainly based on a decreased revision rate. This study is based on the assumption that alignment is a predictor of success in total knee arthroplasty. Until there is data confirming the assertion that alignment predicts success robot-assisted surgery cannot be recommended


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 121 - 121
1 Jul 2014
Boonen B Schotanus M Kerens B van der Wegen W Kort N
Full Access

Summary. Alignment results did not differ between PSG and conventional instrumentation. A small reduction in operation time and blood loss was found with the PSG system, but is unlikely of clinical significance. Length of hospital stay was identical for both groups. Introduction. Several techniques for aligning a TKA exist nowadays. Patient-specific guiding (PSG) has relatively recently been introduced to try to resolve the shortcomings of existing techniques while optimising the operative procedure. Still few reports have been published on the clinical outcome and on the peroperative results of this new technique. This prospective, double-blind, randomised controlled trial was designed to address the following research questions: 1. Is there a significant difference in outliers in alignment in the frontal and sagittal plane between PSG TKA and conventional TKA. 2. Is there a significant difference in operation time, blood loss and length of hospital stay between the 2 techniques. Patients & Methods. 180 patients were randomised for PSG TKA (group 1) or conventional TKA (group 2) in 2 centres. Patients were stratified per hospital. Alignment of the mechanical axis of the leg and flexion/extension and varus/valgus of the individual prosthesis components were measured on digital, standing, long-leg and standard lateral radiographs by 2 independent outcome assessors in both centres. Percentages of outliers, > 3°, were determined. We compared blood loss, operation time and length of hospital stay. Results. There was no statistically significant difference in mean mechanical axis or outliers in mechanical axis between groups. No statistically significant difference was found for the alignment of the individual components in the frontal plane, nor for the percentages of outliers. There was a statistically significant difference in outliers for the femoral component in the sagittal plane, with a higher percentage of outliers in the group 1 (p = 0.017). No such significant result was found for the tibial component in that plane. All interclass correlation coefficients were good. Blood loss was 100 mL less in group 1 (p = 0.000). Operation time was 5 minutes shorter in group 1 (p = 0.000). Length of hospital stay was almost identical with a mean of 3.6 days (p = 0.657). Discussion/Conclusions. The results in terms of obtaining a neutral mechanical axis and a correct position of the prosthesis components did not differ between groups. A small reduction in operation time and blood loss was found with the PSG system, but is unlikely of any clinical significance. Future research should especially focus on cost-effectiveness analysis and functional outcome of PSG TKA


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 55 - 55
1 Jul 2014
Meijer M Boerboom A Stevens M Bulstra S Reininga I
Full Access

Summary. Computer assisted surgery (CAS) during total knee arthroplasty (TKA) is known to improve prosthetic alignment in coronal and sagittal plane. In this systematic review, no evidence is found that CAS also improves axial component orientation when used during TKA. Introduction. Primary total knee arthroplasty (TKA) is a safe and cost-effective treatment for end-stage knee osteoarthritis. Correct prosthesis alignment is essential, since malpositioning of the prosthesis leads to worse functional outcome and increased wear, which compromises survival of the prosthesis. Computer assisted surgery (CAS) has been developed to enhance prosthesis alignment during TKA. CAS significantly improves postoperative coronal and sagittal alignment compared to conventional TKA. However, the influence of CAS on rotational alignment is a matter of debate. Therefore purpose of this review is to assess published evidence on the influence of CAS during TKA on postoperative rotational alignment. Patients and Methods. This review was performed according to the PRISMA Statement. An electronic literature search was performed in Pubmed, Medline and Embase on studies published between 1991 and April 2013. Studies were included when rotational alignment following imageless CAS-TKA was compared to rotational alignment following conventional TKA. At least one of the following outcome measures had to be assessed: 1) rotational alignment of the femoral component, 2) rotational alignment of the tibial component, 3) tibiofemoral mismatch, 4) the amount of rotational outliers of the femoral component, 5) the amount of rotational outliers of the tibial component. Study selection was performed in two stages and data extraction and methodological quality assessment was conducted independently by two reviewers. Standardized mean difference (SMD) with 95% confidence interval (95% CI) was calculated for continuous variables. The SMDs were interpreted according to Cohen: an SMD of 0.2–0.4 was considered a small effect; 0.5–0.7 was considered moderate; and ≥ 0.8 was considered a large effect. For the comparison of the amount of outliers for femoral and tibial component rotation, the Odds ratio (OR) and 95% CI was calculated. The OR represents the odds of outliers occurring in the CAS group compared with the conventional group. An OR of < 1 favors the CAS group. The OR is considered statistically significant when the 95% CI does not include the value of 1. Results. Seventeen studies met the inclusion criteria. One study was considered of high, 15 studies of medium and one study of low methodological quality. SMD for rotation of the femoral component was −0.07 (−0.19–0.04). For rotation of the tibial component, the SMD was 0.11 (−0.01–0.24). Regarding tibiofemoral mismatch, the SMD was −0.27 (−0.57–0.02). For femoral outliers, the OR was 1.05 (0.78–1.43) and for tibial outliers the OR was 1.12 (0.86–1.47). Discussion / Conclusion. Results of this review show no evidence that CAS-TKA leads to better rotational alignment of the femoral or tibial component or tibiofemoral mismatch. Also no evidence was found that CAS results in a decrease of the amount of outliers regarding femoral or tibial component orientation. However, these conclusions have to be interpreted with caution. The number of included studies was low and strong heterogeneity existed between the studies. Of the 17 included studies, only one study was considered of high methodological quality. Moreover, different methods for assessing tibial component rotation have been used in the studies included


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 57 - 57
1 Jan 2017
Harris S Dhaif F Iranpour F Aframian A Cobb J Auvinet E Howell S Rivière C
Full Access

Conventional TKA surgery attempts to restore patients to a neutral alignment, and devices are designed with this in mind. Neutral alignment may not be natural for many patients, and may cause dissatisfaction. To solve this, kinematical alignment (KA) attempts to restore the native pre-arthritic joint-line of the knee, with the goal of improving knee kinematics and therefore patient's function and satisfaction. Proper prosthetic trochlea alignment is important to prevent patella complications such as instability or loosening. However, available TKA components have been designed for mechanical implantation, and concerns remain relating the orientation of the prosthetic trochlea when implants are kinematically positioned. The goal of this study is to investigate how a currently available femoral component restores the native trochlear geometry of healthy knees when virtually placed in kinematic alignment. The healthy knee OAI (Osteoarthritis Initiative) MRI dataset was used. 36 MRI scans of healthy knees were segmented to produce models of the bone and cartilage surfaces of the distal femur. A set of commercially available femoral components was laser scanned. Custom 3D planning software aligned these components with the anatomical models: distal and posterior condyle surfaces of implants were coincident with distal and posterior condyle surfaces of the cartilage; the anterior flange of the implant sat on the anterior cortex; the largest implant that fitted with minimal overhang was used, performing ‘virtual surgery’ on healthy subjects. Software developed in-house fitted circles to the deepest points in the trochlear grooves of the implant and the cartilage. The centre of the cartilage trochlear circle was found and planes, rotated from horizontal (0%, approximately cutting through the proximal trochlea) through to vertical (100%, cutting through the distal trochlea) rotated around this, with the axis of rotation parallel to the flexion facet axis. These planes cut through the trochlea allowing comparison of cartilage and implant surfaces at 1 degree increments. Trochlear groove geometry was quantified with (1) groove radial distance from centre of rotation cylinder (2) medial facet radial distance (3) lateral facet radial distance and (4) sulcus angle, along the length of the trochlea. Data were normalised to the mean trochlear radius. The orientation of the groove was measured in the coronal and axial plane relative to the flexion facet axis. Inter- and intra-observer reliability was measured. In the coronal plane, the implant trochlear groove was oriented a mean of 8.7° more valgus (p<0.001) than the normal trochlea. The lateral facet was understuffed most at the proximal groove between 0–60% by a mean of 5.3 mm (p<0.001). The medial facet was understuffed by a mean of 4.4 mm between 0–60% (p<0.001). Despite attempts to design femoral components with a more anatomical trochlea, there is significant understuffing of the trochlea, which could lead to reduced extensor moment of the quadriceps and contribute to patient dissatisfaction


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 42 - 42
1 Jun 2012
McKenna R Latif A McLeery M Chambers M Rooney B Leach W
Full Access

We aim to compare post-operative length of stay and cardiopulmonary morbidity in patients randomised to either navigated or conventional total knee arthroplasty (TKA). Patients undergoing primary TKA for osteoarthritis were prospectively assigned randomly to either navigation-guided or control groups and blinded to this. All patients received a PFC implant (DePuy, Warsaw, IN). In the control group the standard femoral intramedullary and tibial extramedullary alignment rod was used. In the navigation group, the BrainLab (Munich, Germany) navigation system was used. All operations were carried out by one of two consultant orthopaedic knee surgeons. Length of post operative hospital stay and the development of cardiopulmonary complication were recorded and groups compared. 100 patients were recruited (55 control vs 45 navigated). Patient demographics were similar in both groups. Mean length of stay was 7 days in the control group (range 3-101), 5 days in the navigation group (range 3-10). The mode was 4 days in both groups. 7 patients (13%) stayed for >7 days in the control group, 3 patients (7%) stayed >7 days in the navigation group(p=0.339). 4 patients(7%) required >10 days inpatient stay in the control group, 0 patients required to stay in hospital for longer than 10 days in the navigation group(p=0.069). The causes for the length of stay exceeding 10 days were pulmonary embolus in 3 patients, and chest infection in 1 patient. Patients undergoing navigation-guided TKA required shorter post-operative inpatient stays than those undergoing arthroplasty using conventional techniques. Fewer patients in the navigation group required stays longer than 7 or 10 days. The difference in post-operative stay was associated with fewer respiratory complications in the navigated group


Objectives

Preservation of both anterior and posterior cruciate ligaments in total knee arthroplasty (TKA) can lead to near-normal post-operative joint mechanics and improved knee function. We hypothesised that a patient-specific bicruciate-retaining prosthesis preserves near-normal kinematics better than standard off-the-shelf posterior cruciate-retaining and bicruciate-retaining prostheses in TKA.

Methods

We developed the validated models to evaluate the post-operative kinematics in patient-specific bicruciate-retaining, standard off-the-shelf bicruciate-retaining and posterior cruciate-retaining TKA under gait and deep knee bend loading conditions using numerical simulation.