Aims. Endoprosthetic reconstruction following distal femur tumour resection has been widely advocated. In this paper, we present the design of an uncemented endoprosthesis system featuring a short, curved stem, with the goal of enhancing long-term survivorship and functional outcomes. Methods. This study involved patients who underwent implantation of an uncemented
Following resection of tumours in the distal femur, reconstruction with joint-sparing prostheses have shown good short-term functional outcomes. There is however limited literature on the affect of knee-sparing prostheses on function of the
Debate surrounds the optimum operative treatment of periprosthetic distal femoral fractures (PDFFs) at the level of well fixed femoral components; lateral locking plate fixation (LLP-ORIF) or distal femoral replacement (DFR). To determine which attributed the least peri-operative morbidity and mortality we performed a retrospective cohort study of 60 consecutive unilateral PDFFs of Su types II (40/60) and III (20/60) in patients ≥60 years; 33 underwent LLP-ORIF and 27 underwent DFR. The primary outcome measure was reoperation. Secondary outcomes included perioperative complications and functional mobility status. Kaplan Meier survival analysis was performed. Cox multivariable regression analysis identified risk factors for reoperation after LLP-ORIF. Mean length of follow-up was 3.8 years (range 1.0–10.4). One-year mortality was 13% (8/60). Reoperation rate was significantly higher following LLP-ORIF: 7/33 vs 0/27, p=0.008. For the endpoint reoperation, five-year survival was better following DFR: 100% compared to 70.8% (51.8 to 89.8 95%CI) (p=0.006). For the endpoint mechanical failure (including radiographic loosening) there was no difference at 5 years: ORIF 74.5% (56.3 to 92.7); DFR 78.2% (52.3 to 100), p=0.182). Reoperation following LLP-ORIF was independently associated with medial comminution: HR 10.7 (1.45 to 79.5, p=0.020). Anatomic reduction was protective against reoperation: HR 0.11(0.013 to 0.96, p=0.046). When inadequately fixed fractures were excluded differences in survival were no longer significant: reoperation (p=0.156); mechanical failure (p=0.453). Reoperation rates are higher following LLP-ORIF of low PDFFs compared to DFR. Where adequate reduction, proximal fixation and augmentation of medial comminution is used there is no difference in survival between LLP-ORIF and DFR.
Introduction. Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture to restore range of motion and knee function. However, the effect of joint line elevation on the resulting TKA kinematics including frontal plane laxity is unclear. Thus, our goal was to quantify the effect of additional
Introduction. Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture. However, the effect of joint line proximalization on TKA kinematics is unclear. Thus, our goal was to quantify the effect of additional
Total Knee Joint Replacement is mostly commonly performed using a measured resection technique. When the PCL is retained 9mm of bone is resected off the distal femur. If the PCL is excised 11m of bone is resected. Computer assisted total knee joint replacement will guide the surgeon to perform the optimal
Abstract. Introduction.
Aims. Surgeons commonly resect additional distal femur during primary total knee arthroplasty (TKA) to correct a flexion contracture, which leads to femoral joint line elevation. There is a paucity of data describing the effect of joint line elevation on mid-flexion stability and knee kinematics. Thus, the goal of this study was to quantify the effect of joint line elevation on mid-flexion laxity. Methods. Six computational knee models with cadaver-specific capsular and collateral ligament properties were implanted with a posterior-stabilized (PS) TKA. A 10° flexion contracture was created in each model to simulate a capsular contracture.
Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the deformities. However,
Introduction. Previous anthropometric studies have reported gender differences in
Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however
Fixed flexion contracture is often present in association with osteoarthritis of the knee and correction is one of the key surgical goals in total knee replacement. Surgical strategies to correct flexion contracture include removal of posterior osteophytes, posterior capsular release and additional
Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however
Purpose; To show that
Introduction. Optimal alignment and position of implants is an important goal In TKA. Conventional mechanical instruments use the anatomic axis and “average” anatomy to position the femoral component to achieve acceptable mechanical limb alignment. Numerous studies have documented the frequency of TKA outliers (+/− 3 degrees) to be 30% or more. The purpose of this study was to determine the “true”
The routine use of a fixed
Lower limb mal-alignment due to deformity is a significant cause of early degenerative change and limb dysfunction. Standard techniques are available to determine the centre of rotation of angulation (CORA) and extent of the majority of deformities, however
Purpose. Many TKA instruments were developed in these days.